Table of Contents. 3. Exposed Fastener Panels

Size: px
Start display at page:

Download "Table of Contents. 3. Exposed Fastener Panels"

Transcription

1 Table of Contents 895 North Parkway 3. Exposed Fastener Panels Exposed Fastener Panels Table of Contents... PE1-2 PBR... PE3-4 PBA... PE5-6 AVP... PE7-8 PBU... PE9-10 PBC... PE11-12 PBD... PE PE15-16 Stormproof... PE17-18 Corrugated... PE19 Retro R... PE20 Jan 2017 PE1

2 Table of Contents 895 North Parkway 3. Exposed Fastener Panels Exposed Fastener Panels This page has been intentionally left blank. PE2 Jan 2017

3 PBR Panel GENERAL DESCRIPTION Coverage width - 36" Minimum slope - 1/2:12 Panel substrate - Galvalume Gauge - 26 standard - 22, 24 and 29 also available in limited colors and min. qty. requirements. Coatings - Acrylic coated Galvalume, Siliconized Polyester and KYNAR 500 PBR panel may be reverse rolled putting the paint finish on the bottom side of the panel for installation as a semi-concealed fastener panel. ARCHITECT / ENGINEER INFORMATION PBR panel is a structural roof and wall panel. Several different UL90 construction numbers are available for this panel. PBR panel is recommended for 1/2:12 or greater roof slopes. Field applied tape sealant is required at panel sidelaps and endlaps for roof applications. PBR is a through fastened panel. Galvalume material must not come in contact with concrete or treated lumber. October 2014 PE3

4 PBR Panel ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT PE4 October 2014

5 PBA Panel GENERAL DESCRIPTION Coverage width - 36" Panel substrate - Galvalume Gauge - 26 standard - 22, 24 and 29 also available in limited colors and min. qty. requirements. Coatings - Acrylic coated Galvalume, Siliconized Polyester and KYNAR 500 PBA is a through fastened architectural wall panel that produces a decorative smooth shadow line effect with semi-concealed fasteners. Striations are standard. PBA panel is also available without striations upon request. ARCHITECT / ENGINEER INFORMATION Use of PBA panel over blanket insulation thicker than 3" usually results in one or more of the following: 1.) Panels will not hold 36" module. 2.) Uniform panel sidelaps will be extremely difficult to maintain. 3.) Panels are prone to exhibit oil canning. Galvalume material must not come in contact with concrete or treated lumber. October 2014 PE5

6 PBA Panel ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT PE6 October 2014

7 AVP Panel GENERAL DESCRIPTION Coverage width - 36" Panel substrate - Galvalume Gauge - 26 standard - 22, 24 and 29 also available in limited colors and min. qty. requirements. Coatings - Acrylic coated Galvalume, Siliconized Polyester and KYNAR 500 AVP is a through fastened architectural wall panel that produces a decorative shadow line effect with semi-concealed fasteners. Pencil ribs and smooth finish are standard with the AVP panel. Embossing is optional. ARCHITECT / ENGINEER INFORMATION The AVP panel can be used for wall application and features pencil ribs, providing improved aesthetics to the building design. The AVP panel allows for more insulation to be added behind the panel, providing greater insulating values that meet the energy codes and R-Value requirements. Galvalume material must not come in contact with concrete or treated lumber. October 2014 PE7

8 AVP Panel ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT PE8 October 2014

9 PBU Panel GENERAL DESCRIPTION Coverage width - 36" Minimum slope - 1:12 Panel substrate - Galvalume Gauge - 26 standard - 29, 24 and 22 also available in limited colors and min. qty. requirements. Coatings - Acrylic coated Galvalume, Siliconized Polyester and KYNAR 500 PBU panel may be reverse rolled putting the paint finish on the bottom side of the panel for installation as a semi-concealed fastener panel. ARCHITECT / ENGINEER INFORMATION PBU panel is a through fastened structural roof and wall panel. Its utility nature also makes it useful for liners, partitions, soffits, facades, etc. PBU panel is UL rated per construction number 39. PBU panel is recommended for 1:12 or greater roof slopes. Field applied tape sealant is required at panel sidelaps and endlaps for roof applications. Galvalume material must not come in contact with concrete or treated lumber. October 2014 PE9

10 PBU Panel ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT PE10 October 2014

11 PBC Panel GENERAL DESCRIPTION Coverage width - 32" Minimum slope - 3:12 Panel substrate - Galvalume Gauge - 26 standard - 29, 24 and 22 also available in limited colors and min. qty. requirements. Coatings - Acrylic coated Galvalume, Siliconized Polyester and KYNAR 500 ARCHITECT / ENGINEER INFORMATION PBC panel is a through fastened structural roof and wall panel. It is designed to be utilized over open structural framing, but can easily be used with a solid substrate. For solid substrate applications we recommend 5/8" minimum plywood with a 30# felt moisture barrier. PBC panel is recommended for 3:12 or greater roof slopes. An additional rib lap is recommended for roof applications decreasing the std. 32" coverage. Field applied tape sealant is required at panel sidelaps for roof applications. PBC endlaps are not recommended. Galvalume material must not come in contact with concrete or treated lumber. October 2014 PE11

12 PBC Panel ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT PE12 October 2014

13 PBD Panel GENERAL DESCRIPTION Coverage width - 32" Panel substrate - Galvalume Gauge - 26 standard - 29, 24 and 22 also available in limited colors and min. qty. requirements. Coatings - Acrylic coated Galvalume, Siliconized Polyester and KYNAR 500 ARCHITECT / ENGINEER INFORMATION PBD panel is a through fastened structural wall panel. It can be used for liner and floor underlayment applications. Galvalume material must not come in contact with concrete or treated lumber. October 2014 PE13

14 PBD Panel ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT PE14 October 2014

15 7.2 Panel GENERAL DESCRIPTION Coverage width - 36" Minimum slope - 1/2:12 Panel substrate - Galvalume Gauge - 24 standard - 29, 26 and 22 also available in limited colors and min. qty. requirements. Coatings - Acrylic coated Galvalume, Siliconized Polyester and KYNAR 500 ARCHITECT / ENGINEER INFORMATION 7.2 panel is a through fastened structural roof and wall panel. The symmetrical ribs make it an ideal panel for roofs, walls, equipment screens and carports. This rugged panel also offers excellent spanning and cantilever qualities. 7.2 panel can be used for horizontal wall applications. Welded corners are also available. 7.2 panel is UL rated per construction number panel is recommended for 1/2:12 or greater roof slopes. Field applied tape sealant is required at panel sidelaps and endlaps for roof applications. Galvalume material must not come in contact with concrete or treated lumber. October 2014 PE15

16 7.2 Panel ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT PE16 October 2014

17 Stormproof Panel GENERAL DESCRIPTION Coverage width - 36" Minimum slope - 3:12 Panel substrate - Galvalume Gauge - 29 standard - 26 and also available in limited colors and min. qty. requirements. Coatings - Acrylic coated Galvalume, Siliconized Polyester and KYNAR 500 ARCHITECT / ENGINEER INFORMATION Stormproof is a through fastened structural roof and wall panel. It also works well for liner, partitions, soffits, facades and agricultural applications. It is designed to be used over open structural framing, but can easily be used with a solid substrate. For solid substrate applications we recommend 5/8" minimum plywood with a 30# felt moisture barrier. For roof applications, field applied tape sealant is required at panel sidelaps and endlaps. Galvalume material must not come in contact with concrete or treated lumber. October 2014 PE17

18 Stormproof Panel ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT PE18 October 2014

19 Corrugated Panel GENERAL DESCRIPTION Coverage width 24 Panel substrate - Galvalume Gauge - 29 standard 26 available in limited colors and min. qty. requirements. Coatings - Acrylic coated Galvalume and Siliconized Polyester Corrugated is a thru fastened wall panel ideal for use with residential, light commercial, farm and ranch buildings, canopies and storage buildings. Galvalume material must not come in contact with concrete or treated lumber. October 2014 PE19

20 Retro-R Panel GENERAL DESCRIPTION Coverage width - 36" Minimum roof slope - 1:12 Panel substrate - Galvalume Gauge - 29 Coatings - Acrylic coated Galvalume and Siliconized Polyester ARCHITECT / ENGINEER INFORMATION Retro-R panel is designed to seat directly over an existing "R" panel and requires no tear off, no additional framing and re-uses many of the existing flashings. Field applied tape sealant is required at panel sidelaps and endlaps for roof applications. Retro-R is a through fastened panel with a factory attached vapor barrier for ease of installation. Galvalume material must not come in contact with concrete or treated lumber. PANEL PROPERTIES PANEL TOP IN COMPRESSION PANEL BOTTOM IN COMPRESSION Wt. Fy GA. 1x Sx Ma 1x Sx Ma psf Ksi in 4 /ft in 3 /ft in-kip/ft in 4 /ft in 3 /ft in-kip/ft ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT SPAN IN FEET 2 SPAN 3 SPAN LIVE LOAD WIND UPLIFT LIVE LOAD WIND UPLIFT * * 20 22* * 13* 13* NOTES: 1. The panel section properties have been calculated in accordance with the 1986 edition of the AISI specifications with 1989 addendum. 2. 1x is for deflection determination. 3. Sx is for bending 4. Ma is allowable bending moment. 5. The panel weight has been deducted from the allowable loads. 6. The wind load stress values have been increased by 33.3% 7. * Deflection loads for a maximum deflection ratio of L/180. PE20 October 2014