1 A9 Green / Total Green Energy Solution Lexington, MA Building Science and Efficiency for Residential Buildings Bijan KHosraviani, Ph.D. November 21, 2017 BSA Space
2 Agenda I. Our Background II. HERS Rating III. Energy Code Overview i. Stretch Code ii IECC Code iii IECC Code IV. Looking to the Energy Code Future V. Incentives & Benefits of Utility Program VI. Questions 2
3 A9 Green Background Established in 2009 Energy Efficiency Consultation & Services Energy Modeling, HERS Ratings Building Diagnostics, Inspection, Testing 3D Rendering & Animation 3D Printing 3
4 Building Analysis & Testing 4
5 3D Rendering & Animation 5
6 3D Printing 6
7 Overall Operate as an extension of the project team Get involved early in the process Guide energy efficiency planning toward an optimal end product Achieve savings on construction costs, on future utility costs, and through rebates programs Total Green Energy Solution, LLC 7
8 HERS Rating HERS: Home Energy Rating System Our 3 Phase Process: Phase I: Plans Review & Energy Modeling Phase II: Midpoint Inspection Phase III: Final Inspection & Testing 8
9 Energy Modeling 9
10 Midpoint Inspection 10
11 Final Inspection & Testing Blower Door Testing Duct Blaster Testing Ventilation Testing 11
12 Final Certificate 12
13 Thermal Bypass Checklist (TBC) Examples: 1.4 Slab Edge insulation 2.1 Walls Behind Shower/Tub 2.2 Walls Behind Fireplace 4.4 Excessive Framing 13
14 TBC Slab Edge Insulation 14
15 TBC Slab Edge Insulation 15
16 TBC Walls Behind Bath Tub / Shower 16
17 TBC Walls Behind Fireplace 17
18 TBC Excessive Framing 18
19 Whole House Infiltration 19
20 Whole House Infiltration 20
21 Insulation 21
22 Basement Insulation 22
23 Energy Code Overview Stretch Energy Code (July 1, 2010) IECC-2012 Code (July 1, 2014) IECC-2015 Code (Jan 2, 107) 23
24 Stretch Code The Stretch Code' is an optional appendix to the Massachusetts building energy code that allows cities and towns to choose a more energy- efficient option. Stretch Energy Code was added to the building code on July 24, 2009 Every 6 months new cities and town are adopting it. 24
25 Stretch Code 25
26 Stretch Code / HERS Index IECC-2009 New Homes: Below 3000 Sqft HERS Index of 70 or Less Above 3000 Sqft HERS Index of 65 or Less Addition/Renovation Below 2000 Sqft HERS Index of 85 or Less Above 2000 Sqft HERS Index of 80 or Less IECC-2015 New Homes: All Size HERS Index of 55 or Less Addition/Renovation All Size HERS Index of 65 or Less 26
27 Zone Map 27
28 2015-IECC Prescriptive 28
29 Foundation Wall ( ) 29
30 Fenestration ( ) 30
31 IECC-2015 Mandatory Blower Door Test 31
32 IECC-2015 Mandatory Duct Leakage Test Total Duct Leakage 4CFM per 100 sqft of Living Space 32
33 2015-IECC Summary 33
34 MA 2015 IECC Not much different than 2012 IECC Except introduction of: Advantages ERI (Energy Rating Index) Compliance Path 1. Flexibility Avg $1700 lower construction cost 2. Marketability Quantified Efficiency Benefits 3. Savings Utility Bill Savings: 1. $300/year comparing to 2012 IECC 2. $850/year comparing to 2006 IECC 34