STOTHERM INSULATED FACADE SYSTEM

Size: px
Start display at page:

Download "STOTHERM INSULATED FACADE SYSTEM"

Transcription

1 RENDER PANEL PANEL FIXING 20mm VH CAVITY BATTEN STO upvc END CAP/MS SEALANT 50mm STO upvc 6mm FINISHING EDGE E2/AS1 COMPLIANT METAL FLASHING 10mm 100mm PROFILED FOAM CLOSURE STRIP UNDER CLADDING HORIZONTAL PROFILED METAL WALL CLADDING INSULATED FACADE EXT.CORNER - HORIZ.PROFILED METAL/ ST 850

2 PANEL 20mm VH CAVITY BATTEN 50mm RENDER WITH 6mm STO PREMESHED FINISHING EDGE & STO upvc END CAP MS SEALANT ON STO JOINT SEAL TAPE OR PEF ROD 6mm MIN.GAP HORIZONTAL PROFILED METAL WALL CLADDING (SPECIFY TYPE, THICKNESS & COATING) 6mm GAP 5 10 FIXINGS IN ACCORDANCE WITH E2/AS1 PROFILED FOAM CLOSURE STRIP UNDER CLADDING DOUBLE STUD REQUIRED REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY INSULATED FACADE INT.CORNER - HORIZ.PROFILED METAL/ ST 851

3 50mm MIN. 50mm MIN. FIXINGS IN ACCORDANCE PROFILED FOAM CLOSURE STRIP UNDER CLADDING WALL UNDERLAY HORIZONTAL PROFILED METAL WALL CLADDING (SPECIFY TYPE, THICKNESS & COATING) 20mm VH CAVITY BATTEN PANEL RENDER WITH 6mm FINISHING EDGE & STO upvc END CAP MS SEALANT ON STO JOINT SEAL TAPE OR PEF ROAD 6mm MIN.GAP 5 A 10 NOTE: A = CHECK WITH SHEET METAL FOLDER. A NARROW NECK MAY REQUIRE A WELDED JOINT OR TOP HAT REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY INSULATED FACADE VERT.JUNCTION - HORIZ.PROFILED METAL/ ST 852

4 HORIZONTAL PROFILED METAL WALL CLADDING (SPECIFY TYPE, THICKNESS & COATING) FIXINGS IN ACCORDANCE 15 35mm MIN. 5mm GAP CONTINUOUS CAVITY DRAINAGE CLOSURE STRIP STO upvc END CAP 35mm MIN. E2/AS1 COMPLIANT METAL FLASHING MS SEALANT RENDER PANEL 1. REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS 2. HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY 3. VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY 4. IN EXTRA HIGH WIND ZONES INCREASE FLASHING TO 60mm MIN.AND USE A RIGID UNDERLAY INSULATED FACADE HORIZ.JUNCTION - HORIZ.PROFILED METAL/ ST 853

5 WALL UNDERLAY CONTINUOUS AROUND CORNERS RENDER PANEL PANEL FIXING 20mm VH CAVITY BATTEN STO upvc 6mm FINISHING EDGE STO upvc END CAP/MS SEALANT E2/AS1 COMPLIANT METAL FLASHING TWO CRESTS VERTICAL PROFILED METAL WALL CLADDING (SPECIFY TYPE, THICKNESS & COATING) FIXINGS IN ACCORDANCE SCALE 1:5 INSULATED FACADE EXT.CORNER - VERTICAL PROFILED METAL/ ST 854

6 PANEL 20mm VH CAVITY BATTEN RENDER WITH 6mm STO PREMESHED FINISHING EDGE & STO upvc END CAP MS SEALANT ON STO JOINT SEAL TAPE OR PEF ROD 6mm MIN.GAP 50mm (SPECIFY COATING) VERTICAL PROFILED METAL WALL CLADDING (SPECIFY TYPE, THICKNESS & COATING) 6mm GAP FIXINGS IN ACCORDANCE DOUBLE STUD REQUIRED REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY INSULATED FACADE INT.CORNER - VERTICAL PROFILED METAL/ ST 855

7 50mm MIN. 10mm GAP ROOF UNDERLAY TO LAP OVER WALL UNDERLAY BY 75mm MIN. FLASHING TAPE OVER VERTICAL PROFILED METAL WALL CLADDING (SPECIFY TYPE, THICKNESS & COATING) 3.5mm VENTILATION GAP, NON VENTED CLOSER FLASHING STO upvc END CAP TO PANEL 35mm MIN. MS SEALANT PANEL OVER 20mm DRAINED CAVITY PANEL FIXING RENDER 1. REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS 2. HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY 3. VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY. FIXING IN ACCORDANCE 4. IN EXTRA HIGH WIND ZONES INCREASE FLASHING TO 60mm MIN.AND USE A RIGID UNDERLAY INSULATED FACADE HORIZ.JUNCTION - VERT.PROFILED METAL/ ST 856