1 C E I L I N G S U S P E N S I O N S Y S T E M S Fast. Easy. Customer Focused. General applications 200 Snap-Grid (Hook) /16) 250 Fire-Front Snap-Grid (Hook) /16) Seismic 1200 & 1200 (Stab) /16) 1250 Fire-Front (Stab) /16) 4000 Tempra (Stab or Hook) 9/16) 4050 Tempra (Stab) 9/16) Fire-Rated 4500 Ultraline (Stab) 9/16) Bolt Slot 1/4) Reveal 4600 Ultraline (Stab) 9/16) Bolt Slot 1/8) Reveal PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 1

2 General Applications Contents /16) Exposed 9/16) Exposed 9/16) Bolt Slot Exposed Tee Systems Snap-Grid (Hook) /16) 250 Fire-Front Snap-Grid (Hook) /16) Seismic 1200 (Stab) /16) 1200 (Stab) /16) 1250 Fire-Front (Stab) /16) Tempra (Stab / Hook) 9/16) 4050 Tempra 9/16) (Stab) Fire-Rated Accessories Specifications Snap-Grid / 250 Fire-Front Snap-Grid Seismic 1200 & 1200 / 1250 Seismic Fire Rated Tempra / 4050 Tempra Fire Rated Bolt Slot / Reveal Systems Ultraline (Stab) 9/16) Bolt Slot 1/4) Reveal 4600 Ultraline (Stab) 9/16) Bolt Slot 1/8) Reveal Accessories - Ultraline Bolt Slot Specifications Ultraline Ultraline Product Cross Reference Guide Service Notes General Conditions of Sale Product Updates chicagometallic.com PRODUCT UPDATES Up-to-date product information for General Applications products is available at chicagometallic.com in the Literature Section of each applicable system. Other Chicago Metallic Suspension Systems Refer to the Special Applications product guide for suspension systems for harsh and controlled environments. Refer to the Drywall Applications product guide for suspension systems for flat and curved drywall as well as SpanFast time saving system for corridors and smaller spaces. see us at.com 2 General Applications Ceiling Suspension Systems

3 200 / 250 (Hook) /16) Exposed Tee Systems 200 Snap-Grid /16) 250 Fire-Front Snap-Grid /16) 200 Snap-Grid (Hook) 1 1 / 2 Non-Fire Rated / Fire Rated Double Web Direct Hung Exposed / 16 Exposed 200 Snap-Grid and 250 Fire-Front Snap-Grid tee systems are designed for use with lay-in acoustical panels. These systems, with a /16) face, are extremely versatile and offer a wide range of creative ceiling options. Applications Can be used with standard lay-in panels, revealed edge, concealed and routed geometric panels. Economical, but quality systems. 250 Fire-Front Snap-Grid (Hook) 1 1 / 2 Features / Benefits Designed for a wide variety of lay-in panels / Provides full ceiling accessibility. Available in a wide range of painted and reflective colors / Many design possibilities as panel can be matched or contrasted. Complete interior concept. Versatility in modular configurations / Offers additional design possibilities. Sustainability / Minimum 25% recycled content, 100% locally recyclable. Flame Spread Rating / Chicago Metallic suspension systems meet a Class-A flame spread rating. / 16 Installation Features / Benefits Hook cross tees / Allow instant access to plenums overhead. Butt cut cross tees / Butt cut cross tees allow ceiling panels to lay flat in suspension system, providing a better appearance. Available in a fire rated system / Expansion reliefs are built into each main tee to compensate for elongation of the materials during fire. Double web construction / Increased strength for greater versatility and durability. Accommodates standard NEMA Type-G lights and air diffusers / Allows for integration of lighting and air supply without creating additional labor. IMPORTANT! A Metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 3

4 200 / 250 (Hook) /16) Exposed Tee Systems Component Slotting and Hanger Hole Placement All overall lengths shown are nominal dimensions. Hanger Holes: MAIN TEES 3 /4) each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots. CROSS TEES 3 /4) each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots, in all cross tees having slots. 200 Snap-Grid /16) 200 & 211 Main Tees: 24 cross tee slots 6) O.C. 207 Cross Tee: 9 cross tee slots 6) O. C. 216 Main Tee: 20 cross tee slots 6) O. C. 278 Cross Tee: 8 cross tee slots, 12) O.C. 229, 251, 257 & 258 Cross Tees: No cross tee slots. 816 & 817 Variable Placement Cross Tees: No cross tee slots. 288 Grid Adapter: No cross tee slots. 209 Cross Tee: 3 cross tee slots 12) O. C. 207 Cross Tee: 5 cross tee slots, 1 at midpoint, one 10) each side of midpoint and one 6) from each end. 250 Fire-Front Snap-Grid /16) 250 & 270 Main Tees: 24 cross tee slots 6) O.C. 253 Cross Tee: 2 cross tee slots 12) O.C. 299 Main Tee: 12 cross tee slots 10) O.C. 254 Cross Tee: 3 cross tee slots 12) O. C. 251, 252, 257 & 258 Cross Tees: No cross tee slots. 4 General Applications Ceiling Suspension Systems

5 200 / 250 (Hook) /16) Exposed Tee Systems Components 200 Snap-Grid /16) Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level Main Tees H 12( 1 1 / 2) / 16) ID H 12( 1 1 / 2) / 16) HD H 10( 1 1 / 2) / 16) ID H* 10( 1 1 / 2) / 16) ID * Used in 20) and 30) modules. Cross Tees - Hook - Butt Cut No slots H 2( 1 1 / 2) / 16) H 4( 1 1 / 2) / 16) H 5( 1 1 / 2) / 16) H 8( 1 1 / 2) / 16) Variable Placement Cross Tees To support acoustical material only H 2( 1 1 / 8) / 16) H 4( 1 1 / 8) / 16) Grid Adapter To change main tee direction H 9) 1 1 / 2) / 16) Wall Angles ( x / 16) x / 16) ( x 7 / 8) x 7 / 8) ( x / 16) x / 16) ( x 2) x 2) ( x 1) x 2) Wall Moldings ( x 3 / 4) x 3 / 8) x 3 / 8) x 3 / 4) ( x 3 / 4) x 3 / 4) x 3 / 4) x 3 / 4) ( x 1 3 / 4) x 3 / 4) x 1 / 4) x 1 1 / 4) ( x 9 / 16) x 3 / 8) x 3 / 8) x / 16) Hanger Wire 96CTL144 12( - straight bundled PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 5

6 200 / 250 (Hook) /16) Exposed Tee Systems Components 250 Fire Front Snap-Grid /16) No slots Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level Main Tees H 12( 1 1 / 2) / 16) ID H 12( 1 1 / 2) / 16) HD Cross Tees - Hook - Butt Cut H 1( 1 1 / 2) / 16) H 2( 1 1 / 2) / 16) H 3( 1 1 / 2) / 16) H 4( 1 1 / 2) / 16) H 20) 1 1 / 2) / 16) H 30) 1 1 / 2) / 16) Wall Angles ( x / 16) x / 16) ( x 7 / 8) x 7 / 8) ( x / 16) x / 16) ( x 2) x 2) ( x 1) x 2) Wall Moldings ( x 3 / 4) x 3 / 8) x 3 / 8) x 3 / 4) ( x 3 / 4) x 3 / 4) x 3 / 4) x 3 / 4) ( x 1 3 / 4) x 3 / 4) x 1 / 4) x 1 1 / 4) ( x 9 / 16) x 3 / 8) x 3 / 8) x / 16) Hanger Wire 96CTL144 12( - straight bundled General Applications Ceiling Suspension Systems

7 200 / 250 (Hook) /16) Exposed Tee Systems Component Performance Data 200 Snap-Grid ALLOWABLE LOAD per ASTM C 635 K Hanger Spacing Main Tee Length 4( 5( 6( ( ID ( ID ( ID ( HD Cross Tee Length 1( 20) 2( 30) 3( 4( 5( 6( 8( 229 2( 32.5 G 209 4( ( ( 1.8 K To convert data into lb/ft 2, divide on center spacing of component into lb/ft. G Limited by safety factor of 2. * Hanger wire required at midpoint of tee. Component Load Test Data (based on 1 / 360 span deflection) Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures. 250 Fire-Front Snap-Grid ALLOWABLE LOAD per ASTM C 635 K Hanger Spacing Main Tee Length 4( 5( 6( ( ID ( HD Cross Tee Length 1( 20) 2( 30) 3( 4( 5( 6( 8( 252 2( 41.0 G 251 * 12) 257 * 20) 90.0 G 258* 30) ( ( 14.1 K To convert data into lb/ft 2, divide on center spacing of component into lb/ft. G Limited by safety factor of 2. UL Fire Rated Assemblies floor-ceiling type 250 A202, A210, A211, A212, D203, D205, D209, D2, D216, D218, G007, G008, G022, G036, G201, G202, G204, G208, G209, G210, G211, G213, G214, G2, G216, G217, G218, G222, G227, G228, G229, G231, G234, G236, G241, G242, G243, G244, G248, G250, G255, G256, G258, G259, J201, L005, L006, L201, L202, L206, L208, L209, L210, L211, L212 roof-ceiling type 250 P201, P202, P203, P204, P206, P207, P210, P211, P213, P214, P2, P216, P217, P219, P225, P227, P228, P229, P230, P231, P235, P237, P238, P239, P241, P242, P244, P245, P246, P250, P251, P253, P255, P257, P259, P260, P261, P262, P264 Hanger Positions for Fire Rated Situations Fixture weight based on single fixtures only and are covered in the table. Refer to specific design numbers for allowable number of fixtures per square footage of ceiling area. Light Fixture Load Test Data (based on 1 / 360 span deflection) LIGHT FIXTURES MAIN & CROSS TEES - ALLOWABLE FIXTURE WT. LBS. 200 Snap-Grid 250 Fire-Front Snap-Grid Dimensions ( x 4( ( x 2( ( x 4( G 76.0 G 2( x 5( ( x 3( 63.0 G 20) x 48) ) x 60) 37.6 G Limited by safety factor of 2. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 7

8 200 / 250 (Hook) /16) Exposed Tee Systems Specification Data suspension type Snap-Grid Fire-Front Snap-Grid material body HD Galvanized cap galvanized galvanized size width /16) /16) height 1 1/2) 1 1/2) fire fire rated 1 performance heavy duty per ASTM C 635 intermediate duty per ASTM C 635 demountable seismic zones / categories 1, 2 / A, B, C 1, 2 / A, B, C warranty 40 year limited sustainability Minimum 25% recycled content, 100% locally recyclable, global/regional manufacture Palletization Product Cartons Weight LF Number Per Pallet Per Pallet Per Pallet Main Tees H 28 2,492 8, H 28 2,6 8, H 28 1,736 7, H 28 2,6 8, H 28 2,604 8, H 28 1,820 7,000 8 Ft. Cross Tee H 28 1,372 5,600 5 Ft. Cross Tee H 30 2,310 7,500 4 Ft. Cross Tees H 40 1,960 8, H 40 1,880 6,400 3 Ft. Cross Tee H Packaged To Order 2 Ft. Cross Tees H 50 1,400 7, H 50 1,750 7,500 Product Product Cartons Weight LF Number Length Per Pallet Per Pallet Per Pallet 1 Ft. Cross Tee H 50 1,200 5, In. Cross Tee H Packaged To Order 20 In. Cross Tee H Packaged To Order Wall Angles / Moldings Angles ,070, ,460 7, ,620 7, ,960 14, ,230 9,000 Shadow Moldings ,048 12, ,880 12, ,220 4, Packaged To Order 8 General Applications Ceiling Suspension Systems

9 Seismic 1200 / 1200 / 1250 (Stab) /16) Exposed Tee Systems Seismic 1200, 1200 and 1250 Fire-Front /16) Seismic 1200 (Stab) 1 1 / / 16 Non-Fire Rated / Fire Rated Double Web Direct Hung Exposed 1496 Seismic Perimeter Clip / 16 / 16 These systems are designed for use with lay-in acoustical panels. These systems, with a /16) face, are extremely versatile and offer a wide range of creative ceiling options. Applications Use with standard lay-in panels, revealed edge, concealed and routed geometric panels. Economical yet quality systems which can also be used in seismic installations. Features / Benefits Designed for a wide variety of lay-in panels / Provides full ceiling accessibility. Available in a wide range of painted and reflective colors / Many design possibilities as panel can be matched or contrasted. Total interior concept. Versatility in modular configurations / Offers additional design possibilities. Sustainability / Minimum 25% recycled content, 100% locally recyclable. Flame Spread Rating / Chicago Metallic suspension systems meet a Class-A flame spread rating. Installation Features / Benefits Stab-in cross tees / Tees cantilever during installation and will not fall out, making for an easier installation. Protects against lateral pull-out. Cross tees feature a stepped end design / Stepped end cross tees provide additional support. Cross tees fully integrate with all 200 System main and cross tees / This compatibility allows for choice of either hook or stab cross tees. Meets seismic requirements / Stab cross tees protect against lateral pull out. Compliant with worldwide seismic requirements, including IBC. QuickClick end clips / Quick, easy tee installation with an audible click signalling firm engagement. Available in a fire rated system / Expansion reliefs are built into each main tee to compensate for elongation of the materials during fire. Double web construction / Increased strength for greater versatility and durability. Seismic Perimeter Clip (1200 System Only) / Allows for a visually appealing ceiling with the use of a /16) angle in seismic zones D, E and F. Accomodates standard NEMA Type-G lights and air diffusers / Allows for integration of lighting and air supply without creating additional labor (Stab) 1250 Fire-Front (Stab) SST (Seismic Separation Tee) International Building Code (IBC) Seismic Category C, D, E & F Alternative Perimeter Treatment using 1496 Perimeter Clip / / 2 / 16 / / / 2 IMPORTANT! A Metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 9

10 Seismic 1200 / 1200 / 1250 (Stab) /16) Exposed Tee Systems Component Slotting and Hanger Hole Placement All overall lengths shown are nominal dimensions. Hanger Holes: MAIN TEES 3 /4) each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots. CROSS TEES 3 /4) each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots, in all cross tees having slots. Seismic 1200 & 1200 /16) 200 & 211 Main Tees: 24 cross tee slots 6) O.C Cross Tee: 3 cross tee slots, 6) O.C. 216 Main Tee: 20 cross tee slots 6) O. C Cross Tee: 3 cross tee slots, 12) O.C. 1210, 1214 & 1274 Cross Tees: 3 cross tee slots 12) O. C Cross Tee: 8 cross tee slots, 12) O.C. 1214SST Cross Tee: 3 cross tee slots 12) O. C Cross Tee: No cross tee slots. 816 & 817 Variable Placement Cross Tees: No cross tee slots Cross Tee: 3 cross tee slots 12) O. C Fire-Front /16) 250 & 270 Main Tees: 24 cross tee slots 6) O.C Cross Tee: 3 cross tee slots 12) O. C. 299 Main Tee: 12 cross tee slots 10) O.C Cross Tee: 5 cross tee slots, 1 at midpoint, 2 spaced 10) each side of midpoint and 2 spaced 24) each side of midpoint Cross Tee: 3 cross tee slots 12) O.C. 1251, 1252, 1257 & 1258 Cross Tees: No cross tee slots. 10 General Applications Ceiling Suspension Systems

11 Seismic 1200 / 1200 / 1250 (Stab) /16) Exposed Tee Systems Components Seismic 1200 & 1200 /16) Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level No slots SST Main Tees H 12( 1 1 / 2) / 16) ID H 12( 1 1 / 2) / 16) HD H 10( 1 1 / 2) / 16) ID Cross Tees - Stab - Overide H 2( 1 5 / 16) / 16) H 4( 1 1 / 2) / 16) H 4( 1 1 / 2) / 16) SST 4( 1 1 / 2) / 16) H* 4( 1 1 / 2) / 16) H 4( 1 1 / 2) / 16) H 5( 1 1 / 2) / 16) H 6( 1 1 / 2) / 16) H 8( 1 1 / 2) / 16) * Used to support NEMA Type G light fixture. Variable Placement Cross Tees To support acoustical material only H 2( 1 1 / 8) / 16) H 4( 1 1 / 8) / 16) Grid Adapter To change main tee direction H 9) 1 1 / 2) / 16) Wall Angles ( x / 16) x / 16) ( x 7 / 8) x 7 / 8) ( x / 16) x / 16) ( x 2) x 2) ( x 1) x 2) Wall Moldings ( x 3 / 4) x 3 / 8) x 3 / 8) x 3 / 4) ( x 3 / 4) x 3 / 4) x 3 / 4) x 3 / 4) ( x 1 3 / 4) x 3 / 4) x 1 / 4) x 1 1 / 4) ( x 9 / 16) x 3 / 8) x 3 / 8) x / 16) Seismic Perimeter Clip - For use with 1280 System in Category C, D, E and F installations Hanger Wire 96CTL144 12( - straight bundled 50 0 Push Rivets Fasteners** For use with SST 4( Cross Tees ** Included with SST. Part No is for additional fasteners that may be ordered separately if required. PRODUCT chicagometallic.com UPDATES 1496 USA and Canada: / fax: / chicagometallic.com 11

12 Seismic 1200 / 1200 / 1250 (Stab) /16) Exposed Tee Systems Components 1250 Fire-Front /16) Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level No slots Main Tees H 12( 1 1 / 2) / 16) ID H 12( 1 1 / 2) / 16) HD H* 10( 1 1 / 2) / 16) ID * Used in 20) and 30) modules. Cross Tees - Stab - Overide H 20) 1 1 / 2) / 16) H 30) 1 1 / 2) / 16) H 1( 1 1 / 2) / 16) H 2( 1 1 / 2) / 16) H 3( 1 1 / 2) / 16) H 4( 1 1 / 2) / 16) H 5( 1 1 / 2) / 16) Grid Adapter To change main tee direction H 9) 1 1 / 2) / 16) Wall Angles ( x / 16) x / 16) ( x 7 / 8 ) x 7 / 8) ( x / 16) x / 16) ( x 2) x 2) ( x 1) x 2) Wall Moldings ( x 3 / 4) x 3 / 8) x 3 / 8) x 3 / 4) ( x 3 / 4) x 3 / 4) x 3 / 4) x 3 / 4) ( x 1 3 / 4) x 3 / 4) x 1 / 4) x 1 1 / 4) ( x 9 / 16) x 3 / 8) x 3 / 8) x / 16) Hanger Wire 96CTL144 12( - straight bundled General Applications Ceiling Suspension Systems

13 Seismic 1200 / 1200 / 1250 (Stab) /16) Exposed Tee Systems Component Performance Data Seismic 1200 & 1200 ALLOWABLE LOAD per ASTM C 635 K Hanger Spacing Main Tee Length 4( 5( 6( ( ID ( ID ( HD Component Load Test Data (based on 1 / 360 span deflection) Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Cross Tee Length 1( 2( 3( 4( 5( 6( 8( ( 22.8 G ( ( SST 4( ( ( ( ( ( 1.8 Provide extra hangers for tandem fixtures. K To convert data into lb/ft 2, divide on center spacing of component into lb/ft. G Limited by safety factor of Fire-Front ALLOWABLE LOAD per ASTM C 635 K Hanger Spacing Main Tee Length 4( 5( 6( ( ID ( ID ( HD Cross Tee Length 1( 2( 3( 4( 5( 6( 8( ) ( 40.5 G ( ( ( 7.0 K To convert data into lb/ft 2, divide on center spacing of component into lb/ft. G Limited by safety factor of 2. UL Fire Rated Assemblies floor-ceiling type 1250 A202, A210, A211, A212, D203, D205, D209, D2, D216, D218, G007, G008, G022, G036, G201, G202, G204, G208, G209, G210, G211, G213, G214, G2, G216, G217, G218, G222, G227, G228, G229, G231, G234, G236, G241, G242, G243, G244, G248, G250, G255, G256, G258, G259, J201, L005, L006, L201, L202, L206, L208, L209, L210, L211, L212 roof-ceiling type 1250 P201, P202, P203, P204, P206, P207, P210, P211, P213, P214, P2, P216, P217, P219, P225, P227, P228, P229, P230, P231, P235, P237, P238, P239, P241, P242, P244, P245, P246, P250, P251, P253, P255, P257, P259, P260, P261, P262, P264 Hanger Positions for Fire Rated Situations Light Fixture Load Test Data (based on 1 / 360 span deflection) Fixture weight based on single fixtures only and are covered in the table. Refer to specific design numbers for allowable number of fixtures per square footage of ceiling area. LIGHT FIXTURES MAIN & CROSS TEES - ALLOWABLE FIXTURE WT. LBS Seismic 1250 Fire-Front Seismic Dimensions ( x 4( ( x 2( ( x 4( G 76.0 G 88.8 G Limited by safety factor of 2. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 13

14 Seismic 1200 / 1200 / 1250 (Stab) /16) Exposed Tee Systems Specification Data suspension type Seismic 1200 & Fire-Front material body HD Galvanized cap galvanized galvanized size width /16) /16) height 1 1/2) / 1 5/16) 1 1/2) fire fire rated 1 performance heavy duty per ASTM C 635 intermediate duty per ASTM C 635 demountable seismic zones / categories 3, 4 / D, E, F 3, 4 / D, E, F warranty 40 year limited sustainability Minimum 25% recycled content, 100% locally recyclable, global/regional manufacture 1 - Traditional grid products have a Class A approved, factory painted, baked-on finish. Palletization Product Cartons Weight LF Number Per Pallet Per Pallet Per Pallet Main Tees H 28 2,492 8, H 28 2,6 8, H 28 1,736 7, H 28 2,128 8, H 28 2,548 8, H 28 1,820 7,000 8 Ft. Cross Tee H 28 1,288 5,600 6 Ft. Cross Tee H 28 1,036 4,200 5 Ft. Cross Tee H 30 2,175 7, H 30 1,710 7,500 4 Ft. Cross Tees H 40 1,360 8, H 40 1,800 8, SST 40 1,840 8, H 40 2,440 8, H 40 1,320 8, H 40 1,760 8, H 40 1,760 8,000 3 Ft. Cross Tee H Packaged To Order Product Cartons Weight LF Number Per Pallet Per Pallet Per Pallet 2 Ft. Cross Tee H 50 1,200 7, H 50 1,750 7,500 1 Ft. Cross Tee H 50 1,0 5,000 Misc Cross Tees H 50 1,500 6, H 40 1,160 5,000 Product Cartons Weight LF Number Length Per Pallet Per Pallet Per Pallet Wall Angles / Moldings Angles ,070, ,460 7, ,620 7, ,960 14, ,230 9,000 Shadow Moldings ,048 12, ,880 12, ,220 4, Packaged To Order 14 General Applications Ceiling Suspension Systems

15 4000 / 4050 Tempra (Stab or Hook) 9/16) Exposed Tee Systems 4000 Tempra 9/16) 4050 Tempra 9/16) Fire Rated 4000 Tempra (Stab or Hook) 1 1 / 2 Non-Fire Rated / Fire Rated Double Web Direct Hung Exposed 9 / Tempra and fire rated 4050 Tempra systems are exposed with a narrow face that accentuates a ceiling design with its subtle, crisp, clean lines. These sytems minimize the appearance of the ceiling grid, while emphasizing the aesthetic qualities of the ceiling design. Applications Can be used as an alternative to standard lay-in systems, revealed systems or concealed systems. Tempra works exceptionally well with the geometric shapes and patterns of routed panels. Features / Benefits 9/16) narrow capped face / Allows for more of the ceiling panel and less of the ceiling grid to be visible, providing a monolithic look. Designed for standard lay-in and reveal-edge panels / Provides full ceiling accessibility. Panels are readily available, economical and easy to install. Wide range of possible modular configurations / Offers additional design possibilities. Available in a wide range of painted and reflective colors / Many design possibilities as panel can be matched or contrasted. Total interior concept. Sustainability / Minimum 25% recycled content, 100% locally recyclable. Flame Spread Rating / Chicago Metallic suspension systems meet a Class-A flame spread rating. Installation Features / Benefits Panel self-centering mechanisms / The built-in self-centering device keeps lay-in panels perfectly aligned to hide panel edges. Stab-in cross tees / Tees cantilever during installation and will not fall out, making for an easier installation. Protects against lateral pull-out. Butt cut cross tees (4000 system only) / Butt cut cross tees allow ceiling panels to lay flat in suspension system, providing a better appearance. QuickClick end clips / Quick, easy tee installation with an audible click signalling firm engagement. Standard inverted T, suspended ceiling system / Installs easily, like standard exposed systems. Double web construction / Increased strength for better durability. Seismic Perimeter Clip (4000 System Only) / Allows for a visually appealing ceiling with the use of a /16) angle in seismic zones C, D, E and F. Accomodates standard NEMA Type-G lights and air diffusers / Allows for integration of lighting and air supply without creating additional labor Fire Rated Tempra (Stab) Hook-type Stab-type International Building Code (IBC) Seismic Category C, D, E & F Alternative Perimeter Treatment using 1496 Perimeter Clip IMPORTANT! A Metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed. 9 / / 2 PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com

16 4000 / 4050 Tempra (Stab or Hook) 9/16) Exposed Tee Systems Component Slotting and Hanger Hole Placement All overall lengths shown are nominal dimensions. Hanger Holes: MAIN TEES 3 /4) each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots. CROSS TEES 3 /4) each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots, in all cross tees having slots. 4000Tempra 9/16) 4000CH Main Tee: 24 cross tee slots 6) O.C. starting 3) from each end. 40CH Cross Tee: 5 cross tee slots 10) O.C. 4040CH Main Tee: 24 cross tee slots 6) O.C. starting 3) from each end. 4034CH Cross Tee: 1 cross tee slot at midpoint. 4020CH, 4022CH and 4032CH Cross Tees: No cross tee slots. 4001CH Main Tee: 11 cross tee slots 10) O.C. starting 5) from each end. Panel self-centering spacers are embossed into all components 24) O.C. 4014CH Cross Tee: 3 cross tee slots 12) O.C. 4050Tempra 9/16) Fire-Rated 4050CH Main Tee: 24 cross tee slots 6) O.C. starting 3) from each end. 4054CH Cross Tee: 3 cross tee slots 12) O.C. Panel self-centering spacers are embossed into all components 24) O.C. 4052CH Cross Tee: No cross tee slots. 16 General Applications Ceiling Suspension Systems

17 4000 / 4050 Tempra (Stab or Hook) 9/16) Exposed Tee Systems Components 4000Tempra 9/16) 4000CH-4001CH 4040CH 4020CH-4022CH (No slots) 4014CH-40CH 4032CH-4034CH Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level 01 White Finish Main Tees CH 12( 1 1 / 2) 9 / 16 ) ID CH 12( 1 5 / 8) 9 / 16) HD CH 10( 1 1 / 2) 9 / 16 ) ID Cross Tees - Stab - Overide CH 20) 1 1 / 2) 9 / 16 ) CH 2( 1 1 / 2) 9 / 16 ) CH 4( 1 1 / 2) 9 / 16 ) CH 5( 1 1 / 2) 9 / 16 ) Cross Tees - Hook - Butt Cut CH 2( 1 1 / 2) 9 / 16 ) CH 4( 1 1 / 2) 9 / 16 ) Wall Angles ( x / 16) x 9 / 16) ( x / 16) x / 16) ( x / 16) x 9 / 16) Wall Moldings ( x 3 / 4) x 3 / 8) x 3 / 8) x 3 / 4) ( x 3 / 4) x 3 / 4) x 3 / 4) x 3 / 4) ( x 1 3 / 4) x 3 / 4) x 1 / 4) x 1 1 / 4) ( x 9 / 16) x 3 / 8) x 3 / 8) x / 16) Hanger Wire 96CTL144 12( straight bundled PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 17

18 4000 / 4050 Tempra (Stab or Hook) 9/16) Exposed Tee Systems Components 4050Tempra 9/16) Fire-Rated 4050CH 4052CH 4054CH Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level Main Tees CH 12( 1 1 / 2) 9 / 16) ID Cross Tees - Stab - Overide CH 2( 1 1 / 2) 9 / 16) CH 4( 1 1 / 2) 9 / 16) Wall Angles ( x / 16) x 9 / 16) ( x / 16) x / 16) ( x / 16) x / 16) Wall Moldings ( x 3 / 4) x 3 / 8) x 3 / 8) x 3 / 4) ( x 3 / 4) x 3 / 4) x 3 / 4) x 3 / 4) ( x 1 3 / 4) x 3 / 4) x 1 / 4) x 1 1 / 4) ( x 9 / 16) x 3 / 8) x 3 / 8) x / 16) Hanger Wire 96CTL144 12( straight bundled General Applications Ceiling Suspension Systems

19 4000 / 4050 Tempra (Stab or Hook) 9/16) Exposed Tee Systems Component Performance Data Tempra 4000 ALLOWABLE LOAD per ASTM C635 K Hanger Spacing Main Tee Length 4( 5( 6( 4000CH 12( ID CH 12( HD CH 10( ID Cross Tee Length 2( 3( 4( 5( 8( 4022CH 2( 24.5 G 4032CH 2( 24.5 G 4014CH 4( CH 4( CH 5( 6.5 K To convert data into lb/ft 2, divide on center spacing of component into lb/ft. G Weight limited by a safety factor of 2. Component Load Test Data (based on 1 / 360 span deflection) Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures. Tempra 4050 Fire Rated ALLOWABLE LOAD per ASTM C635 K Hanger Spacing Main Tee Length 4( 4050CH 12( ID Cross Tee Length 2( 4( 4052CH 2( 45.0 G 4054CH 4( 12.9 K To convert data into lb/ft 2, divide on center spacing of component into lb/ft. G Weight limited by a safety factor of 2. Fire Rated Assemblies Hanger Positions for Fire Rated Situations This illustrates hanger positions for single fixtures in a field and are covered in the table. Refer to specific design numbers for allowable number of fixtures per square footage of ceiling area. Light Fixture Load Test Data (based on 1 / 360 span deflection) LIGHT FIXTURES MAIN & CROSS TEES - ALLOWABLE FIXTURE WT. LBS CH 4000CH 4001CH CH Dimensions 4014CH 40CH 40CH CH 1( x 4( ( x 2( ( x 4( G ) x 48) ) x 60) PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 19

20 4000 / 4050 Tempra (Stab or Hook) 9/16) Exposed Tee Systems Specification Data suspension type Tempra Tempra Fire Rated material body HD Galvanized cap HD Galvanized or Aluminum size width 9/16) 9/16) height 1 1/2) 1 1/2) fire fire rated 1 performance heavy duty per ASTM C 635 intermediate duty per ASTM C 635 demountable seismic zones / categories - main tees - 1, 2, 3, 4 / A, B, C, D, E, F zones / categories - stab cross tees - 1, 2, 3, 4 / A, B, C, D, E, F zones / categories - hook cross tees - 1, 2 / A, B, C warranty 40 year limited sustainability Minimum 25% recycled content, 100% locally recyclable, global/regional manufacture 1 - Tempra grid products have a Class A approved, factory painted, baked-on finish. Palletization Product Cartons Weight LF Number Per Pallet Per Pallet Per Pallet Main Tees CH 28 2,310 10, CH 28 2,058 8, CH 30 2,520 7, CH 28 2,590 10,080 5 Ft. Cross Tee 40.01CH 30 2,040 9,000 4 Ft. Cross Tees CH 40 2,160 9, CH 40 2,200 8, CH 40 2,340 8,000 2 Ft. Cross Tees CH 50 1,750 10, CH 50 1,750 10, CH 50 2,550 10, In. Cross Tee CH Packaged To Order Product Product Cartons Weight LF Number Length Per Pallet Per Pallet Per Pallet Wall Angles / Moldings Angles ,070, ,170 9, ,230 9,000 Shadow Moldings ,048 12, ,880 12, ,220 4, Packaged To Order 20 General Applications Ceiling Suspension Systems

21 Accessories Exposed Tee Systems Accessories Exposed Tee Systems Product Dimensions Per Carton Service Number Length Recess Flanges Ft Pcs Wt Levels Grid Adapter To change Main Tee direction H 9) 1 1 / 2 ) / 16 ) H 9) 1 1 / 2 ) / 16 ) One end has main Tee coupling and the other end has a cross tee tab. Variable Placement Cross Tees To support acoustical material only H 2( 1 1 / 2 ) / 16 ) H 4( 1 1 / 2 ) / 16 ) Hanger Wire 96CTL144 12( straight bundled 50 0 Product Per Carton Service Number Description Ft Pcs Wt Levels Hold Down Clips For 5 / 8 ) board - 250/1200 Systems For 5 / 8 ) board - 250/1250 Systems For various board heights for rectangular bulb grid systems Intersection Clip 4.00 Locks Spacer Clips to components For hook-type cross tee components Expansion Coupling Cover Covers expansion joints Cross Tee Slotter For T type Systems Retention Clips For 1) thick panels For 1) to 2) thick panels 0 0 Cross Tee Removal Tool Wire Tie Tool Seismic Perimeter Clip For T type Systems Spacer Bars H 2( For rectangular bulb components H 4( For rectangular bulb components H 4( notched 2( For rectangular bulb components PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 21

22 Specifications 200 / 250 Exposed Tee Systems 200 Snap-Grid PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for lay-in acoustical panel ceiling Related Sections A. Section Suspension Systems B. Section Specialty Ceilings C. Section Integrated Ceiling Assemblies D. Section Sound, Vibration, and Seismic Control E. Section Central Heating Equipment F. Section Lighting 1.03 References A. American Society for Testing and Materials (ASTM) 1. C635 - Standard Specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels Submittals A. Product data sheets listing dimensions, load carrying capacity and standards compliance. B. 12 inch long samples of Main Tees and Cross Tees with integral couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area receiving suspension system prior to installation. 2. Wet trades work to be thoroughly dry and complete prior to installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic double web (Intermediate) (Heavy) duty non-fire rated ceiling suspension system Suspension System Components A. Main Tees: 1. Manufactured from commercial quality steel /16 inch wide by 1 1 /2 inches high with factory punched cross tee slots, hanger holes, and integral bayonet-style end couplings. 2. Capped with steel capping affixed to /16 inch wide flange. 3. Coated with factory applied baked-on enamel paint from manufacturer s standard selection. B. Cross Tees: 1. Manufactured from commercial quality steel /16 inch wide by 1 1 /2 inch high with factory punched cross tee slots, hanger holes, and integral snap-grid end couplings. 2. Capped identical to main tees. 3. Finish identical to main tees. C. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from commercial quality steel with hemmed edges finished identical to main tees and cross tees. 2. Channel Moldings: Manufactured from commercial quality steel with factory applied standard white baked-on enamel paint finish. 3. Shadow Line Moldings: a. Manufactured from commercial quality steel with 3 /4 inch flanges and 3 /4 inch steps with exposed hemmed edge. Finished with factory applied standard baked-on enamel paint finish. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Main Tees: Installed (36) (48) (60) (96) inches on center, by direct suspension from existing structure, with not less than 12 gage steel hanger wires, wrapped tightly 3 full turns, spaced (48) (60) inches on center along component length. B. Cross Tees: 1. Installed perpendicular to main tees (12) (20) (24) (30) (48) (60) (72) (96) (120) inches on center to form by modules. 2. Installed perpendicular to module forming cross tees (12) (20) (24) (30) inches on center to form by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. C. (Angle) (Channel) (Shadow Line) Moldings: Installed on vertical surfaces, intersecting suspension components by appropriate method in accordance with industry accepted practice. D. Additional Hanger Wires: Wrapped tightly 3 full turns to structure and components at locations where imposed loads could cause deflection exceeding 1 /360 span Repair A. Remove damaged components, replace with undamaged components. Clean with non-solvent based nonabrasive commercial cleaning solution. 250 Fire-Front Snap-Grid PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for lay-in acoustical panel ceiling Related Sections A. Section Suspension Systems B. Section Specialty Ceilings C. Section Integrated Ceiling Assemblies D. Section Sound, Vibration, and Seismic Control E. Section Central Heating Equipment F. Section Lighting 1.03 References A. American Society for Testing and Materials (ASTM) 1. C635 - Standard Specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels. B. Underwriters Laboratories (UL) Fire Resistance Directory (latest edition) 1.04 Submittals A. Product data sheets listing dimensions, load carrying capacity and standards compliance. B. 12 inch long samples of Main Tees and Cross Tees with integral couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area receiving suspension system prior to installation. 2. Wet trades work to be thoroughly dry and complete prior to installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic double web (Intermediate) (Heavy) duty fire rated ceiling suspension system Suspension System Components A. Main Tees: 1. Manufactured from commercial quality galvanized steel /16 inch wide by 1 1 /2 inches high by 144 inches long with factory punched cross tee slots, hanger holes, and integral bayonet-style end couplings. 2. Capped with steel capping affixed to /16 inch wide flange. 3. Coated with factory applied color selected from manufacturer s standard offering. 4. Manufactured with fire expansion reliefs. B. Cross Tees: 1. Manufactured from commercial quality galvanized steel /16 inch wide by 1 1 /2 inch high by (24) (36) (48) (60) inches long with factory punched cross tee slots, hanger holes, and integral snap-grid end couplings. 2. Capped identical to main tees. 3. Finish identical to main tees. 4. Manufactured with fire expansion reliefs. C. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from commercial quality galvanized steel /16 inch wide by /16 inch high by (120) (144) inches long with hemmed edges finished identical to main tees and cross tees. 2. Channel Moldings: Manufactured from commercial quality galvanized steel with factory applied standard white baked-on enamel paint finish. Note: Specifier to select from channels offered by Chicago Metallic. 3. Shadow Moldings: a. Manufactured from commercial quality galvanized steel with 3 /4 inch flanges, 3 /4 inch recess and exposed hemmed edge. Finished with factory applied standard baked-on enamel paint finish. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Suspension System Components: Installed in accordance with U.L design number guidelines. B. Main Tees: Installed (36) (48) (60) (96) inches on center, by direct suspension from existing structure, with not less than 12 gage steel hanger wires, wrapped tightly 3 full turns, spaced (48) (60) inches on center along component length. C. Cross Tees: 1. Installed perpendicular to main tees (12) (20) (24) (30) (48) (60) inches on center to form by modules. 2. Installed perpendicular to module forming cross tees (12) (20) (24) (30) inches on center to form by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. D. (Angle) (Channel) (Shadow) Moldings: Installed on vertical surfaces, intersecting suspension components by appropriate method in accordance with industry accepted practice. E. Additional Hanger Wires: Wrapped tightly 3 full turns to structure and components at locations where imposed loads could cause deflection exceeding 1 /360 span Repair A. Remove damaged components, replace with undamaged components. Clean with non-solvent based nonabrasive commercial cleaning solution. 22 General Applications Ceiling Suspension Systems

23 1200 / 1250 Specifications Exposed Tee Systems Seismic 1200 & 1200 PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for lay-in acoustical panel ceiling Related Sections A. Section Suspension Systems B. Section Specialty Ceilings C. Section Integrated Ceiling Assemblies D. Section Sound, Vibration, and Seismic Control E. Section Central Heating Equipment F. Section Lighting 1.03 References A. American Society for Testing and Materials (ASTM) 1. C635 - Standard Specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels. 3. IBC-2006 Section 1613, ASCE7-05 Section and CISCA Recommendations For Direct Hung Acoustical Tile And Lay-In Panel Ceilings - Seismic Zones 0-2 May IBC-2006 Section 1613, ASCE7-05 Section and CISCA Guidelines For Seismic Restraint For Direct Hung Suspended Ceiling Assemblies - Seismic Zones 3 & 4 May Submittals A. Product data sheets listing dimensions, load carrying capacity and standards compliance. B. Samples: 12 inch long samples of main tee and cross tee with couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area to receive suspension system prior to installation. 2. Wet trades work to be thoroughly dry and complete prior to suspension system installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic (Intermediate)(Heavy) duty non-rated double web suspension system Suspension System Components A. Main Tees: 1. Manufactured from commercial quality steel /16 inch wide by 1 1 /2 inches high by (120)(144) inches long with factory punched cross tee slots, hanger holes, and integral bayonet-style end couplings. 2. Capped with steel capping affixed to /16 inch flange. 3. Coated with factory applied (standard [architect select color] baked-on enamel paint). B. Cross Tees: 1. Manufactured from commercial quality steel /16 inch wide by 1 1 /2 inches high by(12)(20)(24)(30)(36)(48)(60) (72)(96)(120) inches long with factory punched cross tee slots and hanger holes. 2. Capped identical to main tees. 3. Coated identical to main tees. 4. Manufactured with factory attached stainless steel stab-in end couplings on component ends)(stab-in cupling on one end, integral separation joint on other end). C. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from inch thick steel ( 3 /4)( /16)( 7 /8)(2) inch wide by ( /16)( 7 /8)(1)(2) inch high by (120)(144) inches long, finished identical to main tees and cross tees. 2. Channel Moldings: Manufactured from inch thick steel with factory applied standard white baked-on enamel paint finish. Note: Specifier to select from channels offered by Chicago Metallic. 3. Shadow Line Moldings: Manufactured from inch thick steel with 3 /4 inch and 3 /8 inch hemmed edge. Finished with factory applied standard baked-on enamel paint finish. 4. Seismic Perimeter Clips: Manufactured from commercial quality steel with gold finish sized to fit 1 1 /2 inch high ceiling grid components and clip to minimum ( 7 /8)( /16)(2) inch wide wall angle support with minimum ( 3 /8) ( 3 /4) inch clearance at perimeter walls and ceiling penetrations per IBC 2006 Seismic Design Category (C) (D, E, F). PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Main Tees: Installed (24)(36)(48)(60)(96) inches on center, by direct suspension from existing structure, with not less than 12 gage steel hanger wires spaced (36)(48)(60) inches on center along main tee length. Wrap hanger wires tightly 3 full turns at each end. B. Cross Tees: 1. Manufactured from commercial quality steel /16 inch wide by [1 1 /2 inches high by (12)(20)(24)(30)(36)(48)(60) (72)(96)(120) inches long][1 5 / 16 inches high by (24)(48) inches long] with factory punched cross tee slots and hanger holes. 2. Installed perpendicular to module forming cross tees to form by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. C. SST Cross Tees: 1. Installed aligning two seismic separation ends perpendicular to main tees and connecting them together using two plastic push rivets (12)(20)(24)(30)(36)(48)(60)(72)(120) inches on center to form by modules. 2. Installed perpendicular to module forming cross tees to form by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. D. (Angle)(Channel)(Shadow Line) moldings: Installed on vertical surfaces, intersecting suspension components, by appropriate method in accordance with industry accepted practice. E. Additional Hanger Wires: Wrapped tightly 3 full turns to structure and component at locations where imposed loads could cause deflection exceeding 1 /360 span Repair A. Remove damaged components, replace with undamaged components. Clean with non-solvent based nonabrasive commercial cleaning solution Fire-Front PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for lay-in acoustical panel ceiling Related Sections A. Section Suspension Systems B. Section Specialty Ceilings C. Section Integrated Ceiling Assemblies D. Section Sound, Vibration, and Seismic Control E. Section Central Heating Equipment F. Section Lighting 1.03 References A. American Society for Testing and Materials (ASTM) 1. C635 - Standard Specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels. B. Underwriters laboratories (UL) Fire Resistance Directory (latest edition) 1.04 Submittals A. Product data sheets listing dimensions, load carrying capacity and standards compliance. B. 12 inch long samples of Main Tees and Cross Tees with integral couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area to receive suspension system prior to installation. 2. Wet trades work to be thoroughly dry and complete prior to suspension system installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic (Intermediate) (Heavy) duty fire rated double web suspension system Suspension System Components A. Main Tees: 1. Manufactured from commercial quality galvanized steel /16 inch wide by 1 1 /2 inches high by 144 inches long with factory punched cross tee slots, hanger holes, and integral bayonet-style end couplings. 2. Capped with steel capping affixed to /16 inch flange. 3. Coated with factory applied color selected from manufacturer s standard offering. B. Cross Tees: 1. Manufactured from commercial quality galvanized steel /16 inch wide by 1 1 /2 inches high by (24)(36)(48)(60) inches long with factory punched cross tee slots and hanger holes. 2. Capped identical to main tees. 3. Coated identical to main tees. 4. Manufactured with factory attached stainless steel couplings on component ends. C. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from commercial quality galvanized steel /16 inch wide by /16 inch high by (120) (144) inches long with hemmed edges finished identical to main tees and cross tees. 2. Channel Moldings: Manufactured from commercial quality galvanized steel with factory applied standard white baked-on enamel paint finish. Note: Specifier to select from channels offered by Chicago Metallic. 3. Shadow Moldings: a. Manufactured from commercial quality galvanized steel with 3 /4 inch flanges, 3 /4 inch recess and exposed hemmed edge. Finished with factory applied standard baked-on enamel paint finish. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Suspension System Components: Installed in accordance with UL design number guidelines. B. Main Tees: Installed (36)(48)(60) inches on center, by direct suspension from existing structure, with not less than 12 gage steel hanger wires spaced (48)(60) inches on center along main tee length. Wrap hanger wires tightly 3 full turns at each end. C. Cross Tees: 1. Installed perpendicular to main tees (12)(20)(24)(30)(36)(48)(60) inches on center to form by modules. 2. Installed perpendicular to module forming cross tees to form by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. D. (Angle)(Channel)(Shadow) moldings: Installed on vertical surfaces, intersecting suspension components, by appropriate method in accordance with industry accepted practice. E. Additional Hanger Wires: Wrapped tightly 3 full turns to structure and component at locations where imposed loads could cause deflection exceeding 1 /360 span Repair A. Remove damaged components, replace with undamaged components. Clean with non-solvent based nonabrasive commercial cleaning solution. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 23

24 Specifications 4000 / 4050 Exposed Tee Systems 4000 Tempra PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for acoustical lay-in panel ceiling Related Sections A. Section Suspension Systems B. Section Specialty Ceilings C. Section Gypsum Board D. Section Integrated Ceiling Assemblies E. Section Sound, Vibration, and Seismic Control F. Section Central Heating Equipment G. Section Lighting 1.03 References A. American Society for Testing and Materials (ASTM) 1. C635 - Standard Specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels Submittals A. Product data sheets listing dimensions, load carrying capacity and standards compliance. B. Samples: 12 inch long samples of main tee and cross tee with end couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area to receive suspension system prior to installation. 2. Wet trades work shall be dry and complete prior to installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic Tempra 4000 (Intermediate)(Heavy) duty suspension system Suspension System Components A. Main Tees: 1. Manufactured from commercial quality galvanized steel 9 /16 inch wide by 1 1 /2 inches by (120) (144) inches long with factory punched cross tee slots, hanger holes, and integral end couplings. 2. Capped with (steel)(aluminum) with standard factory applied baked-on enamel paint. 3. Manufactured with ceiling panel centering tabs. B. Cross Tees: 1. Manufactured from commercial quality galvanized steel 9 /16 inch wide by 1 1 /2 inches high by (12) (20) (24) (30) (48) (60) inches long with factory punched cross tee slots, hanger holes, and either snap-in or stab-in end tab. 2. Capped identical to main tees. 3. Manufactured with ceiling panel centering tabs. C. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from commercial quality galvanized steel ( 9 /16)( /16) inch wide by /16 inch high by 144 inches long, finished identical to main tees and cross tees. 2. Shadow Moldings: Manufactured from commercial quality galvanized steel with 3 /4 inch flanges and 3 /8 inch steps coated with factory applied baked-on enamel paint finish identical to main tees and cross tees. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Main Tees: Installed (48) (60) inches on center, by direct suspension from existing structure, with not less than 12 gage hanger wires, wrapped tightly 3 full turns, spaced 48 inches on center along component length. B. Cross Tees: 1. Installed perpendicular to main tees (20) (24) (30) (48) (60) inches on center to form by modules. 2. Installed perpendicular to module forming cross tees (20)(24)(30) inches on center forming by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. C. (Angle) (Shadow) moldings: Installed on vertical surfaces, intersecting main runners and cross tees, by appropriate method in accordance with industry accepted practice Repair A. Remove damaged components, replace with undamaged components. Clean with non-solvent based non-abrasive commercial cleaning solution Tempra Fire Rated PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for acoustical lay-in panel ceiling Related Sections A. Section Suspension Systems B. Section Specialty Ceilings C. Section Gypsum Board D. Section Integrated Ceiling Assemblies E. Section Sound, Vibration, and Seismic Control F. Section Central Heating Equipment G. Section Lighting 1.03 References A. American Society for Testing and Materials (ASTM) 1. C635 - Standard Specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels. B. Underwriters Laboratories (UL) Fire Resistance Directory (Latest edition) 1.04 Submittals A. Product data sheets listing dimensions, load carrying capacity and standards compliance. B. Samples: 12 inch long samples of main tee and cross tee with end couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area to receive suspension system prior to installation. 2. Wet trades work shall be dry and complete prior to installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic Fire Front Tempra 4050 Intermediate duty suspension system 2.02 Suspension System Components A. Main Tee: 1. Manufactured from commercial quality galvanized steel 9/16 inch wide by 1-1/2 inches by (120) (144) inches long with factory punched cross tee slots, hanger holes, and integral bayonet-style end couplings. 2. Capped with (steel)(aluminum) with standard factory applied baked-on enamel paint. 3. Manufactured with ceiling panel centering tabs. 4. Manufactured with fire expansion reliefs on fire rated components. B. Cross Tees: 1. Manufactured from commercial quality galvanized steel 9 /16 inch wide by 1 1 /2 inches high by (24) (48) inches long with factory punched cross tee slots, hanger holes, and stab-in end tab. 2. Capped identical to main tees. 3. Manufactured with ceiling panel centering tabs. C. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from commercial quality galvanized steel ( 9 /16)( /16) inch wide by /16 inch high by 144 inches long, finished identical to main tees and cross tees. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Suspension System Components: Installed in accordance with UL design number guidelines. B. Main Tee: Installed (48) (60) inches on center, by direct suspension from existing structure, with not less than 12 gage hanger wires, wrapped tightly 3 full turns, spaced 48 inches on center along component length. C. Cross Tees: 1. Installed perpendicular to main tees (20) (24) (30) (48) (60) inches on center to form by modules. 2. Installed perpendicular to module forming cross tees (20)(24)(30) inches on center forming by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. D. (Angle) (Shadow Line) moldings: Installed on vertical surfaces, intersecting main tees and cross tees, by appropriate method in accordance with industry accepted practice Repair A. Remove damaged components, replace with undamaged components. Clean with non-solvent based non-abrasive commercial cleaning solution. 24 General Applications Ceiling Suspension Systems

25 4500 / 4600 Ultraline (Stab) Bolt Slot / Reveal Systems 4500 Ultraline 9/16), 1/4) Reveal Bolt Slot and 4600 Ultraline 9/16), 1/8) Reveal Bolt Slot 4500 (Stab) 9 / 16 1 / / 8 Non-Fire Rated Double Web Direct Hung Exposed Ultraline 4500 narrow face significantly diminishes the distinction between grid and panel creating a monolithic ceiling. The slender center regress and crisply mitered intersections result in flawless and continuous lines. Ultraline 4600 more subtly accents the shadow of the center regress. Applications Can be used as a more workable alternate to concealed ceilings or as an upgrade to standard lay-in ceilings. Black or white center regress available. Features / Benefits 9/16) narrow face / Minimizes the appearance of the grid creating a monolithic look. Grid and panel on same plane, panel does not lay on top of grid. Designed for reveal-edge panels / Complete plenum access from any point in the ceiling. Mitered intersections / Provide crisp continuous lines that create a uniform ceiling plane. Versatility in modular configurations / Offers additional design possibilities s extremely narrow 1/8) regress / Accents the shadow while enhancing the monolithic ceiling look. Sustainability / Minimum 25% recycled content, 100% locally recyclable. Flame Spread Rating / Chicago Metallic suspension systems meet a Class-A flame spread rating. Installation Features / Benefits Stab-in cross tees / Tees cantilever during installation and will not fall out, making for an easier installation. Protects against lateral pull-out. Notch covers / Conceals unused cross tee notches. Available cut-off notcher / Saves time in cutting main and cross tees, providing a finished appearance. Double web construction / Increased strength for better durability. Accomodates standard NEMA Type-SS lights and air diffusers / Allows for integration of lighting and air supply without creating additional labor (Stab) 9 / 16 1 / / 8 IMPORTANT! A Metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 25

26 4500 / 4600 Ultraline (Stab) Bolt Slot / Reveal Systems Component Slotting and Hanger Hole Placement All overall lengths shown are nominal dimensions. Hanger Holes: MAIN TEES 3 /4) each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots. CROSS TEES 3 /4) each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots, in all cross tees having slots. 4500Ultraline 9/16), 1/4) Reveal Bolt Slot Main Tee: 11 cross tee slots with notches, 24 O.C Cross Tee: 1 cross tee slot with notch, 24 O.C Cross Tee: 1 cross tee slot with notch one side only, 24 O.C Main Tee: 11 cross tee slots with notches, 48 O.C Cross Tee: 1 cross tee slot with notch, 30 O.C Cross Tee: 1 cross tee slot with notch one side only, 30 O.C Main Tee: 9 cross tee slots with notches, 24 O. C Cross Tee: 2 cross tee slots, no notches Main Tee: 7 cross tee slots with notches, 30 O. C Cross Tee: 3 cross tee slots, no notches Main Tee: 11 cross tee slots with notches, 20 O. C Cross Tee: No cross tee slots Cross Tee: No cross tee slots. 4511, 4520, 4512 and 4513: No slots, holes or notches. 26 General Applications Ceiling Suspension Systems

27 4500 / 4600 Ultraline (Stab) Bolt Slot / Reveal Systems Components 4500Ultraline 9/16), 1/4) Reveal Bolt Slot Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level 01 White with 1 / 4 01 White Reveal Main Tees /4 9 /16 ID /4 9 /16 ID /4 9 /16 ID /4 9 /16 ID /4 9 /16 ID Cross Tees - Stab - Mitered /4 9 / /4 9 / /4 9 / /4 9 / /4 9 / /4 9 / /4 9 / /4 9 / /4 9 / /4 9 / /4 9 / /4 9 / Wall Angles x 9 /16 x / x /16 x / x /16 x / * 12 x /16 x 1 3 / Wall Molding x 3 /4 x 3 /8 x 3 /8 x 3 / x 3 /4 x 3 /4 x 3 /4 x 3 / ( x 1 3 / 4) x 3 / 4) x 1 / 4) x 1 1 / 4) * 10 x 3 /4 x 3 /8 x 3 /8 x / ( x 9 / 16) x 3 / 8) x 3 / 8) x / 16) Hanger Wire 96CTL straight bundled 50 0 * To allow for use of Bolt Slot Grid with 1496 Clip 1466 PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 27

28 4500 / 4600 Ultraline (Stab) Bolt Slot / Reveal Systems Component Slotting and Hanger Hole Placement All overall lengths shown are nominal dimensions. Hanger Holes: MAIN TEES 3 /4) each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots. CROSS TEES 3 /4) each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots, in all cross tees having slots. 4600Ultraline 9/16), 1/8) Reveal Bolt Slot Main Tee: 11 cross tee slots with notches, 24 O.C Cross Tee: 1 cross tee slot with notch, 24 O.C Cross Tee: 1 cross tee slot with notch one side only, 24 O.C Main Tee: 11 cross tee slots with notches, 48 O.C Cross Tee: 1 cross tee slot with notch, 30 O.C Main Tee: 7 cross tee slots with notches, 30 O. C Cross Tee: 2 cross tee slots, no notches Main Tee: 11 cross tee slots with notches, 20 O. C Cross Tee: 3 cross tee slots, no notches. 4611, 4620, 4612, 4613, 4624, 4621 Cross Tee: No cross tee slots or notches. 28 General Applications Ceiling Suspension Systems

29 4500 / 4600 Ultraline (Stab) Bolt Slot / Reveal Systems Components 4600Ultraline 9/16), 1/8) Reveal Bolt Slot Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level 01 White with 1/8) 01 White Reveal Main Tees ( 1 5 / 8) 9 / 16) ID ( 1 5 / 8) 9 / 16) ID ( 1 5 / 8) 9 / 16) ID ( 1 5 / 8) 9 / 16) ID Cross Tees - Stab - Mitered ( 1 5 / 8) 9 / 16) ) 1 5 / 8) 9 / 16) ( 1 5 / 8) 9 / 16) ) 1 5 / 8) 9 / 16) ( 1 5 / 8) 9 / 16) ( 1 5 / 8) 9 / 16) ( 1 5 / 8) 9 / 16) ( 1 5 / 8) 9 / 16) ( 1 5 / 8) 9 / 16) ( 1 5 / 8) 9 / 16) ( 1 5 / 8) 9 / 16) Wall Angles ( x / 16) x 9 / 16) ( x / 16) x / 16) ( x / 16) x / 16) * 12 x /16 x 1 3 / Wall Molding ( x 3 / 4) x 3 / 8) x 3 / 8) x 3 / 4) ( x 3 / 4) x 3 / 4) x 3 / 4) x 3 / 4) ( x 1 3 / 4) x 3 / 4) x 1 / 4) x 1 1 / 4) * 10 x 3 /4 x 3 /8 x 3 /8 x / ( x 9 / 16) x 3 / 8) x 3 / 8) x / 16) Hanger Wire 96CTL144 12( straight bundled 50 0 * To allow for use of Bolt Slot Grid with 1496 Clip 1466 PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 29

30 4500 / 4600 Ultraline (Stab) Bolt Slot / Reveal Systems Accessories Ultraline Bolt Slot / Reveal Systems Product Per Carton Service Number Description Ft Pcs Wt Levels Outside/Square Corner Caps Outside/Radius Corner Caps Inside Corner Caps Corner Caps Outside/ Square For 3 / 4) angle For / 16) angle For 9 / 16) angle For 2) angle Corner Caps Outside/Radius For 3 / 4) angle, 3 / 4) radius For / 16 ) angle, 3 / 4) radius For 3 / 4) angle, 1) radius For / 16 ) angle, 1) radius For 7 / 8) angle, 1 / 8 ) radius For 7 / 8) angle, 3 / 4) radius Corner Caps Inside For 3 / 4) angle For 9 / 16) angle For / 16) angle For 2) angle For 7 / 8) angle Blank Square Notch Covers / 8) L System Only / 8) L System Only Lay-in Air Diffuser ( x 2( Single Slot Diffuser with 8) collar Hold Down Clip Adjust to different height board Perimeter Clip For 1 1 / 2) components Cut-Off/End Notcher For 4500 and 4600 Systems Cross Tee Slotter For 4500 and 4600 Systems Hanger Wire 96CTL144 12( straight bundled General Applications Ceiling Suspension Systems

31 4500 / 4600 Ultraline (Stab) Bolt Slot / Reveal Systems Component Performance Data Ultraline / 16) Exposed with 1 / 4) Reveal ALLOWABLE LOAD per ASTM C635 K Hanger Spacing Main Tee Length 4( 5( 6( ( ID ( ID ( ID ( ID ( ID Cross Tee Length 2( 4( 5( ( 55.0 G ( ( ( ( ( ( ( ( K To convert data into lb/ft 2, divide on center spacing of component into lb/ft. G Weight limited by a safety factor of 2. Component Load Test Data (based on 1 / 360 span deflection) Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures. Ultraline / 16) Exposed with 1 / 8) Reveal ALLOWABLE LOAD per ASTM C635 K Hanger Spacing Main Tee Length 4( 5( 6( ( ID ( ID ( ID ( ID Cross Tee Length 2( 4( 5( ( 55.0 G ( ( ( ( ( ( ( K To convert data into lb/ft 2, divide on center spacing of component into lb/ft. G Weight limited by a safety factor of 2. Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 31

32 4500 / 4600 Ultraline (Stab) Bolt Slot / Reveal Systems Component Performance Data Light Fixture Load Test Data (based on 1 / 360 span deflection) LIGHT FIXTURES MAIN & CROSS TEES - ALLOWABLE FIXTURE WT. LBS Dimensions ( x 2( ( x 4( ) x 48) Specification Data suspension type material body galvanized cap N/A size width 9/16) 9/16) fire fire rated 1 height 1 5/8) 1 5/8) performance heavy duty per ASTM C 635 intermediate duty per ASTM C 635 demountable seismic zones / categories 3,4 / D, E, F 3,4 / D, E, F warranty 40 year limited sustainability Minimum 25% recycled content, 100% locally recyclable, global/regional manufacture 32 General Applications Ceiling Suspension Systems

33 4500 / 4600 Ultraline (Stab) Bolt Slot / Reveal Systems Palletization Product Cartons Weight LF Number Per Pallet Per Pallet Per Pallet Main Tees ,440 5, ,440 5, ,224 4, ,224 4, ,224 4, ,416 5, ,416 5, ,608 4, ,608 4,800 8 Ft. Cross Tee PTO PTO PTO PTO PTO PTO 6 Ft. Cross Tee PTO PTO PTO PTO PTO PTO 5 Ft. Cross Tee ,560 6, ,560 6, ,560 6, ,560 6, PTO PTO PTO PTO PTO PTO 4 Ft. Cross Tees ,722 6, ,722 6, ,722 6, ,722 6, ,722 6, ,722 6, ,722 6, ,722 6,720 Product Cartons Weight LF Number Per Pallet Per Pallet Per Pallet 30 In. Cross Tees PTO PTO PTO 2 Ft. Cross Tees ,750 7, ,750 7, ,800 7, In. Cross Tees ,450 5, PTO PTO PTO 1 Ft. Cross Tees ,000 4, PTO PTO PTO Product Product Cartons Weight LF Number Length Per Pallet Per Pallet Per Pallet Wall Angles / Moldings Angles ,070, ,170 9, ,230 9, ,170 9,000 Shadow Moldings ,048 12, ,880 12, ,220 4, ,464 12, Packaged To Order PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 33

34 4500 / 4600 Ultraline Specifications Bolt Slot / Reveal Systems 4500 Ultraline PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for acoustical lay-in panel ceiling Related Sections A. Section Suspension Systems B. Section Specialty Ceilings C. Section Gypsum Board D. Section Integrated Ceiling Assemblies E. Section Sound, Vibration, and Seismic Control F. Section Central Heating Equipment G. Section Lighting 1.03 References A. American Society for Testing and Materials (ASTM) 1. C635 - Standard Specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical tile and Lay-in Panel Ceilings. 2. C636 - Standard Practice for installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels Submittals A. Product data sheets listing dimensions, load carrying capacity and standards compliance. B. 12 inch long samples of main tee and cross tee with end couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area to receive suspension system prior to installation. 2. Wet trades work shall be dry and complete prior to installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area Ultraline PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for acoustical lay-in panel ceiling Related Sections A. Section Suspension Systems B. Section Specialty Ceilings C. Section Gypsum Board D. Section Integrated Ceiling Assemblies E. Section Sound, Vibration, and Seismic Control F. Section Central Heating Equipment G. Section Lighting 1.03 References A. American Society for Testing and Materials (ASTM) 1. C635 - Standard Specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical tile and Lay-in Panel Ceilings. 2. C636 - Standard Practice for installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels Submittals A. Product data sheets listing dimensions, load carrying capacity and standards compliance. B. 12 inch long samples of main tee and cross tee with end couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area to receive suspension system prior to installation. 2. Wet trades work shall be dry and complete prior to installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic Ultraline 4500 Intermediate duty suspension system Suspension System Components A. Main Tees: 1. Manufactured from commercial quality galvanized steel 9 /16 inch wide with 1 /4 inch center regress by 1 5 /8 inches high by (120) (144) inches long with factory punched cross tee slots, hanger holes, miters and integral couplings. 2. Coated with factory applied color baked-on enamel finish. B. Cross Tees: 1. Manufactured from commercial quality galvanized steel 9 /16 inch wide with 1 /4 inch center regress by 1 5 /8 inches high by (24) (48) (60) inches long with factory punched cross tee slots, hanger holes, miters and integral couplings. 2. Finish and regress identical to main tees. C. Angle Moldings: Manufactured from commercial quality galvanized steel 9 /16 inch wide by /16 inch high by 144 inches long with hemmed edges, finished identical to main tees and cross tees. D. Shadow Moldings: Manufactured from commercial quality galvanized steel with 3 /4 inch flanges and 3 /8 inch steps coated with factory applied baked-on enamel paint finish identical to main tees and cross tees. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Main Tees: Installed (48) (60) inches on center, by direct suspension from existing structure, with not less than 12 gage hanger wires, wrapped tightly 3 full turns, spaced 48 inches on center along component length. B. Cross Tees: 1. Installed perpendicular to main tees (24) (48) (60) inches on center to form by modules. 2. Installed perpendicular to module forming cross tees 24 inches on center forming by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. C. (Angle) (Shadow) moldings: Installed on vertical surfaces, intersecting main tees and cross tees, by appropriate method in accordance with industry accepted practice Repair A. Remove damaged components, replace with undamaged components. Clean with non-solvent based non-abrasive commercial cleaning solution. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic Ultraline 4600 Intermediate duty suspension system Suspension System Components A. Main Tees: 1. Manufactured from commercial quality galvanized steel 9 /16 inch wide with 1 /8 inch center regress by 1 5 /8 inches high with factory punched cross tee slots, hanger holes, miters and integral couplings. 2. Coated with factory applied baked-on enamel finish. B. Cross Tees: 1. Manufactured from commercial quality galvanized steel 9 /16 inch wide with 1 /8 inch center regress by 1 5 /8 inches high with factory punched cross tee slots, hanger holes, miters and integral couplings. 2. Finish and regress identical to main tees. C. Angle Moldings: Manufactured from commercial quality galvanized steel 9 /16 inch wide by /16 inch high by 144 inches long with hemmed edges, finished identical to main tees and cross tees. D. Shadow Moldings: Manufactured from commercial quality galvanized steel with 3 /4 inch flanges and 3 /8 inch steps coated with factory applied baked-on enamel paint finish identical to main tees and cross tees. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Main Tees: Installed (20), (30), (48), (60) inches on center, by direct suspension from existing structure, with not less than 12 gage hanger wires, wrapped tightly 3 full turns, spaced 48 inches on center along component length. B. Cross Tees: 1. Installed perpendicular to main tees (20), (24), (30), (48), (60) inches on center to form by modules. 2. Installed perpendicular to the module forming cross tees (20), (24), (30) inches on center forming by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. C. (Angle), (Shadow Line) Moldings: Installed on vertical surfaces, intersecting main runners and cross tees, by appropriate method in accordance with industry accepted practice. 34 General Applications Ceiling Suspension Systems

35 Product Cross Reference Product Cross Reference Guide Chicago Metallic AWI USG General Application Grid 200 Snap-Grid Prelude ML 250 Fire-Front Snap-Grid 1200 Seismic Prelude XL DX 1250 Fire-Front Seismic Prelude XL Fire Guard DXL Fire Rated 4000 Tempra Suprafine XL DXT Centricitee 4050 Tempra Fire Rated Suprafine XL Fire Guard DXLT Centricitee 4500 Ultraline Silhouette XL 1/4 Reveal DXF Fineline 1/ Ultraline Silhouette XL 1/8 Reveal DXF Fineline 1/8 Special Application Grid BarrierGrid Standard Clean Room Controlled Environment BarrierGrid Premium Clean Room Controlled Environment 260/280 Aluminum Cap 1260/1280 Aluminum Cap Prelude XL DXLA Aluminum Cap / 8 Wide Face DXW 730 Stainless SS Prelude Plus XL DXSS 830 Aluminum AL Prelude Plus XL AX All Aluminum 1830 HDG-60 Prelude XL Exterior ZXLA Hot Dipped Drywall Grid 640/660 Drywall Grid 650/670 Fire Rated Drywall Grid Fire Guard Drywall Suspension SpanFast ShortSpan Wall-to-Wall PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 35

36 Service Levels, Support & Samples Service Service Levels Service Levels represents the approximate time in weeks for an order to be ready to ship from the manufacturing plant. Add 2 weeks to all Service Levels for CMC transfer truck to Baltimore or Los Angeles Service Centers. Service Level begins when the following criteria are met Receipt of acceptable Purchase Order, Credit Approval, Drawing Approval, Color Approval. Service Levels Production Lead Time 0 Stock item available for immediate shipment 1 Available to ship within 1 week of order acceptance 2 Available to ship within 2 weeks of order acceptance 3 Available to ship within 3 weeks of order acceptance 4 Available to ship within 4 weeks of order acceptance 5 Available to ship within 5 weeks of order acceptance 6 Available to ship within 6 weeks of order acceptance?? Contact Chicago Metallic for current lead time Color Samples 1. Custom color matching requires customer color sample or paint manufacturer and color number. 2. CMC will provide color sample for approval upon request. 3. Service Level begins after receipt of color approval. Order Placement and General Customer Service Support Phone: / option 1 Fax: cmc-customerservice@chicagometallic.com Standard Samples and Literature Standard literature, product samples and color samples are available from the CMC Sample and Literature department at no charge. Phone: / option 1 Fax: cmc-customerservice@chicagometallic.com Technical Support Requests for technical information on CMC Metal Ceilings may be placed with the Technical Services Department. Phone: option 3 Fax: techservices@chicagometallic.com Mockups and Custom Samples When CMC has agreed to provide custom samples or mockups, the cost for them will be billed to the account. CMC will be glad to issue credit upon request for all mockups and custom sample invoices when valid orders for these products are placed with our Customer Service Department. Phone: Fax: cmc-customerservice@chicagometallic.com 36 General Applications Ceiling Suspension Systems

37 General Conditions of Sale General Conditions of Sale Order Acceptance Whenever used herein, Seller shall refer to Chicago Metallic Corporation and Purchaser shall refer to the party ordering or purchasing products ( Products ) from Seller. Seller s price list does not constitute an offer to sell Products listed therein, but is simply provided as a convenience to prospective Purchasers. Purchaser s order to Seller shall constitute an offer to Seller to purchase Products which offer Seller may accept at its sole discretion. Acceptance shall be by a writing containing these General Conditions of Sale ( Conditions ). Acceptance of Purchaser s order or any part of it by Seller is expressly made conditional on Purchaser s assent to these Conditions. Purchaser may vary these Conditions only with the written consent of Seller. Acceptance of Products by Purchaser or failure of Purchaser to object in writing to these Conditions within ten (10) days following delivery of Products to Purchaser shall constitute Purchaser s assent to these Conditions. Shipment and Delivery Seller shall deliver Product F.O.B. place of shipment. Risk of loss to Product shall pass to Purchaser upon delivery to carrier at such place of shipment. Carrier acts as Purchaser s agent. Products shall be shipped as soon as practical, or as requested by Purchaser after order acceptance by Seller. However, delivery dates shall not be of the essence, but shall be regarded as Seller s best approximation of such delivery dates. Seller may arrange freight at the request of and on behalf of Purchaser. If applicable, freight will be charged according to the Seller s freight policy in effect at time of shipment. Such policy will be provided to Purchaser via its preferred communication method and is also available in Seller s price book or upon request. All taxes, tariffs, duties or similar charges paid by Seller imposed or levied by any governmental authority in connection with the purchase, shipment, import or export of Products purchased or in connection with the procuring of materials used therein may at Seller s sole option be added to the price of Products so affected. Additional shipping charges for Products paid by Seller such as destination, storage, labor and redelivery and special or extra expenses for handling air freight, bus or other shipments may also, at Seller s sole option, be added to the price of such Products. Payment Payment for all Products shall be net cash due and payable in U.S. dollars within thirty (30) days following receipt by Purchaser of shipping documents for such Products by check or bank transfer to a bank account to be designated by Seller. If accounts are paid within ten (10) days following receipt by Purchaser of the corresponding shipping documents, Purchaser shall been entitled to a one percent (1%) discount from the price of Products only. If, in Seller s sole opinion, the financial condition of the Purchaser so warrants, Seller may require advance payments or satisfactory security. In the event that the Purchaser fails to make such advance payments or furnish such security upon Seller s request, delivery of Products may be suspended without further Seller obligation. Seller may, at Seller s sole option, require payment by means of an irrevocable letter of credit opened and confirmed by a bank or banks acceptable to Seller and upon terms and conditions acceptable to Seller. Limited Warranty Seller warrants to Purchaser that Products will substantially conform in quantity and quality to Purchaser s order, as accepted by Seller, provided, however, that (1) Products are inspected by Purchaser upon arrival at place of destination and any and all nonconformities are noted on the bill of lading and all other delivery documents and are attested to in writing by carrier s representative (2) Purchaser furnishes Seller with written notice of such non-conformities within fifteen () days following arrival of non-conforming Products at the place of destination, (3) Purchaser holds nonconforming Products for Seller s inspection (4) non-conformities occurred prior to delivery by Seller of Products F.O.B. place of shipment, and (5) Purchaser does not alter, repair, use or attempt to alter or repair any non-conforming Products. This limited warranty is Seller s only and exclusive express warranty to Purchaser. Seller disclaims any and all implied warranties including without limitation any implied warranty of merchantability or fitness for a particular purpose. Purchaser s sole and exclusive remedy against Seller shall be the replacement F.O.B. its plant or site, at Seller s option, of any Products which do not conform to Seller s limited warranty hereunder. No other remedy (including, without limitation, incidental or consequential damages for lost profits, lost sales, injury to persons or property or any other incidental or consequential loss) shall be available to Purchaser. Purchaser agrees to include in all contracts between Purchaser and subsequent owners or users of Products, and to bring to the attention of all Purchaser s customers of Products, the following warranty disclaimer: Chicago Metallic Corporation disclaims any and all warranties expressed or implied, including, without limitation, any implied warranty of merchantability or fitness for a particular purpose. Purchaser shall be excluded on behalf of Seller all remedies for damage or injury to Products persons or property. In the event that Purchaser fails to comply with the foregoing obligations, Purchaser shall indemnify Seller for any liability resulting from such non-compliance and shall otherwise hold Seller harmless. Returns In order to return any Products to Seller, Purchaser must first obtain prior authorization for products eligible for return, and receive a Return Goods Authorization number from Seller s home office. All authorized returns are subject to a 20% restocking charge. Seller will only issue credit for Service Level 0 material received at the designated company facility with the Return Goods Authorization appearing on the material, and after being inspected and determined by Seller to be in resalable condition. Purchaser is solely responsible for arranging and prepaying for all return freight. Seller will not be responsible for any damage in transit on material returned at customer s request, and will not file freight claims on such damaged material. When these terms are met, seller will issue appropriate material credit less the restocking charge. Default, Termination and Suspension of Delivery Seller reserves the right, among other remedies, either to cancel Purchaser s order or suspend further deliveries of Products thereunder in the event that (1) Purchaser fails to pay for any one shipment of Products when payment for such shipment becomes due; (2) Purchaser fails to make any advance payments or satisfactory security demanded by Seller pursuant to paragraph two of PAYMENTS section above; or (3) Purchaser fails or refuses to accept any delivery of Products ordered from Seller. Delivery of Products may be suspended in whole or in part in case of any event beyond Seller s control, including, but not limited to, explosion, fire, shortage of fuel, power or raw materials flood strike lockout, injunction, riot, insurrection, war, national emergency, government act, or act of God. Miscellaneous No failure or delay on the part of Seller in exercising any right, power or privilege hereunder shall operate as a waiver thereof or of any other right, power or privilege hereunder nor shall any single or partial exercise of any such right power or privilege preclude any other right, power or privilege. The rights or remedies of Seller hereunder are cumulative and not exclusive of any rights or remedies which it may otherwise have. The parties hereto may correct stenographic and clerical errors without liability. Purchaser may not assign the order without the express written consent of Seller. All notices to be given hereunder by either party to the other party shall be dispatched by certified or registered mail return receipt requested addressed to the last known post office address of such other party. Any such notice shall be deemed received within five (5) days following any such dispatch if mailed from within the United States of America and ten (10) days if mailed from outside the United States of America. Either party may change its address by notice to the other party. These Conditions shall be governed by and interpreted in accordance with the laws of the State of Illinois, United States of America, and all disputes hereunder that cannot be amicably resolved by the parties thereto must be settled in a court of competent jurisdiction within the State of Illinois, United States of America. The provisions of these Conditions shall be severable one from the other so that should any provision be held legally unenforceable by a court of competent jurisdiction, the remaining provisions shall remain in effect. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 37

38 38 General Applications Ceiling Suspension Systems

39 chicagometallic.com PRODUCT UPDATES USA and Canada: / fax: / chicagometallic.com 39

40 Chicago Metallic Ceiling Products Metal Perimeter Trim/ Curvilinear / Flat Metal Panel / Embossed Metal Panel / Linear / Open Plenum / Security Panel Premium / Utility / Controlled Environment Grid General Applications / Special Applications / Drywall Applications Ceiling Systems and Specialty Products - USA and Canada: / Fax: / chicagometallic.com belgium / denmark / uk / germany / france / hong kong / prc / malaysia / united arab emirates / mexico Chicago Metallic, its logo, Fast.Easy.Customer Focused., SpanFast and QuickClick are Registered Trademarks of Chicago Metallic Corporation. Snap-Grid, Tempra and Ultraline are trademarks of Chicago Metallic Corporation Chicago Metallic Corporation All Rights Reserved Printed in USA SNL0028B2111 Literature Disclaimer: Presentations in this brochure or any other Chicago Metallic Corporation publication are correct to the best of our knowledge at time of preparation. We provide this information in an advisory capacity only. Any advisory recommendations given in our publications must be modified to conform with local codes, conditions and specifications. We reserve all rights to amend any information published in our literature without additional notice. Chicago Metallic can not be held responsible or liable for the selection nor application of our products.

41 Better. Faster. Easier. Reliable. Efficient. Compliant. SEISMIC CEILING SUSPENSION Fast. Easy. Customer Focused.

42 Seismic Codes: Development and Adoption Purpose of Installation Requirements for Suspended Ceilings Suspension systems strong enough to resist lateral force imposed upon it without failing. Prevent border panels from falling from the ceiling plane. Federal Emergency Management Agency (FEMA) Seismic performance during recent large California earthquakes prompted FEMA to address several concerns including suspended ceiling performance during a seismic event. Research and tests demonstrated that current industry seismic standards (UBC Standard 25-2) were not adequate. FEMA determined that the key to good seismic performance was support of individual panels at walls and expansion joints and interaction with sprinkler systems. Source: FEMA 368 NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures New Seismic Categories According to the International Building Code, a Seismic Design Category must be established for each construction project based on: 1. Anticipated ground motion 2. Type of soil in a specific geographic area 3. Occupancy category The Code Official is the Only Authority to Enforce Code Compliance The building code was established to set minimum requirements for life safety and preservation of property. It is important to know that while the building code establishes the requirements, it is the code official that has the power to enforce its provisions. The code official also has the latitude to allow materials and methods of construction that are not addressed in the code. In this case, an official can perform their own analysis of evidence presented or can rely on independent, qualified sources such as ICC-ES to do the analysis and provide their findings. The resulting report is specific, technical evidence on which the code official can base approval of a particular design without delaying construction. Earthquakes Are Coming! California 62% probability of at least one magnitude 6.7 or greater quake in the San Francisco Bay region before All 50 states and the Virgin Islands use the International Building Code (IBC) at a local or state wide level. East Coast & Midwest 90% probability of a magnitude 6 to 7 event occuring within the next 50 years. p2 I I chicagometallic.com

43 Industry Standard Construction ASCE 7-05 Section Seismic Design Category C Reference CISCA Recommendations for Seismic Zones 0-2 The ceiling must be a free-floating system, not attached at any walls. Main and Cross Tees need a minimum of 3/8) clearance from the walls. All perimeter grid components must be tied together to prevent spreading using Spacer Bars, or other means. Must use Safety Wires on light fixtures. Perimeter Support Wires required if Wall Angle support ledge is less than 7/8). Intermediate Duty system, 60 lb. minimum connection strength. Use of hook Cross Tee connection is acceptable. Refer to IBC 2006, ASCE 7-05 and CISCA Seismic Zones 0 & 2 for complete details. ASCE 7-05 Section Seismic Design Categories D thru F Reference CISCA Recommendations for Seismic Zones 3 & 4 Ceiling areas less than 144 ft 2 are exempt of standard construction requirements. Heavy Duty suspension system must be used. All system connections need to withstand a minimum connection strength of 180 lbs. A Wall Angle with a 2) ledge support must be used at the perimeter. Ceiling must be attached on two adjacent walls. The opposing walls must be unattached, with a 3/4) clearance from the wall for the Main or Cross Tees. Spacer Bars, or other means, must be used to tie perimeter components together on unattached walls to prevent spreading. Perimeter Wires must be used within 8) from the wall on all four walls. Safety Wires must be attached to the light fixtures. Light Fixtures must be positively attached to the grid system. Ceiling penetrations, like sprinklers, must provide clearance for movement. Ceiling areas larger than 1,000 ft 2 require horizontal restraint every 144 ft 2 consisting of four diagonal Splay Wires or rigid braces in combination with a Compression Post. Ceiling areas larger than 2,500 ft 2 require a Seismic Separation Joint. Ceilings subject to special inspection per ASCE 7-05 Section (h). Refer to IBC 2006, ASCE 7-05 and CISCA Seismic Zones 3 & 4 for complete details. chicagometallic.com I I p3

44 Seismic Ceiling Installation: FAQ Can I use any CMC grid in seismic applications? Because ceiling panel performance and non-tee bar suspension systems are not well defined in the IBC requirements, CMC is working with an independent, internationally renowned structural engineering firm to test both standard and non-standard ceiling systems for seismic performance. The results of our full-scale seismic tests offer proven safety and performance support for standard and non-standard ceilings, flexible design options, and more efficient installation designs. The following CMC grid systems are acceptable for use in International Building Code Seismic Design Categories: 200 Snap-Grid / 640, 650, 660 & 670 Drywall / 660 Wide Face / 730 All Stainless Steel / 830 All Aluminum / 1200 Seismic / 1260 Aluminum Cap / 4500 & 4600 Bolt Slot / 4000 Tempra Contact Chicago Metallic for specific components and corresponding Seismic Design Categories. Note: Check local code for installation requirements. Where can I find the information I need to install ceilings to meet seismic requirements? You will first need to verify the seismic design category for the building in which you will be installing your ceiling. This information will be determined by the architect or designer on record, and can be found in the general information section of the specifications or in the general notes on the structural drawings. You will then want to refer to the building code and installation standards that are currently being used or accepted in your jurisdiction, and are available from your local code official. What is a seismic design category? A Seismic Design Category (SDC) is a classification assigned to a structure based on its occupancy or use (Occupancy Category) and on the level of expected soil modified seismic ground motion. This can be expressed schematically as follows: [Occupancy Category] + [Soil modified seismic ground motion] SDC Seismic Design Category (SDC) A B C D E and F What does it mean? Very small seismic vulnerability Low to moderate seismic vulnerability Moderate seismic vulnerability High seismic vulnerability Very high seismic vulnerability and near a major fault Where can I find instructions detailing each step needed to install ceilings that meet seismic design categories? Generally accepted installation standards are based on current versions of the IBC, ASCE-7, the CISCA Seismic documents, and the ASTM E 580, and are straightforward. If you need additional assistance, please feel free to contact our Technical Services team at , option 3. How can I verify what codes my local or state officials require us to follow? Each local or state government office has a department that manages building permits and construction requirements. You should contact them to see what installation standards they will require. p4 I I chicagometallic.com

45 Seismic Ceiling Installation: FAQ My building owner does not like the 2) wall molding that is required in IBC seismic design categories D, E and F. Is there an alternative? How can local code officials be sure that the use of the Chicago Metallic perimeter clip is compliant with the IBC? Chicago Metallic has designed a seismic perimeter clip, item # , which provides for the use of a /16) wall angle while eliminating the need for perimeter spacer bars. This clip has been recognized by ICC-ES as an alternative installation that is compliant with the IBC. Official approval of this alternative remains the purview of the Authority Having Jurisdiction (AHJ). See ICC-ES ESR-2282 at Chicago Metallic s seismic grid system, including the perimeter clip, was rigorously tested at the Structural Engineering Earthquake Simulation Laboratory (SEESL) at the State University of New York at Buffalo. The evaluation process, including room size testing on shake tables at the University were monitored by engineers from Chicago Metallic and the State University of New York at Buffalo, as well as by engineers from an independent structural engineering group, to insure accurate data was properly collected and summarized. This report was then submitted to ICC-ES, where our suspended ceiling grid and perimeter clip has been recognized by ICC-ES to perform as required by the current IBC. Where can the local code officials or I find verification of the testing, or recognition by ICC-ES? Our evaluation report (ICC-ESR 2282) from ICC-ES can be found on their website at The evaluation report can be found under the search function on the website, by entering either our manufacturers name (Chicago Metallic), or our ICC-ES report number (2282). The report will provide in detail the evaluation of our product and proper installation requirements. There is also a link to the report directly from the Chicago Metallic web site. Has an alternative method for seismic separation joints been developed yet? Chicago Metallic has designed what we believe is the only seismic separation joint alternative that has been both tested at the State University of New York at Buffalo and evaluated by an independent, internationally-renowned structural engineering group. The Seismic Separation Tee (SST) from Chicago Metallic has been designed to provide movement due to seismic activity along the separation joint. Seismic activity causes the SST tees to move linearly, thus eliminating the need for a conventional separation joint. Other benefits over competitive products or standard recommended installations include: a one-step installation process Just insert the tees and install push rivets to create the expansion joint, and you are done. There is no going back to cut main or cross tees or to add additional channels, angles or clips. Is there written documentation for the SST too? Our independent structural engineering group has written a summary report that shows that our SST performs in such a way that meets the requirements outlined by the IBC. This report can be delivered directly to the code official by contacting Chicago Metallic and providing us with the code officials contact information (name, address) along with the project name and location. chicagometallic.com I I p5

46 Seismic Ceiling System Details Though suspended ceilings are considered non-structural, recommendations for seismic stabilization do exist. However, traditional seismic ceiling construction is costly. Additional joint clips, wires, stabilizer bars, and seismic separation joints increase the cost of materials, while attaching separator clips and field cutting cross tees significantly impact labor costs. In addition to its Seismic 1200 Intermediate and Heavy Duty grid, Chicago Metallic now introduces the Seismic Separation Cross Tee (SST ) and Perimeter Clip, both of which can save up to 75% in material and labor costs compared to traditional installation methods. Seismic 1200 Exposed Grid /16) Wall Angle Chicago Metallic s Exposed Tee grid includes seismic and fire-rated seismic constructions. The 1200 System is offered for Intermediate Duty and Heavy Duty performance per ASTM C 635 to satisfy the requirements of all Seismic code constructions. The exposed tee construction permits direct upward access to mechanical systems and is a cost-effective solution to seismic requirements. Stab-in cross tees cantilever during installation and will not fall out, making for an easier installation and protecting against lateral pull-out. When used with the Seismic Separation Tee, the /16) wide face creates a sleek ceiling design in all seismic installations Seismic Perimeter Clip Stab-in cross tees with QuickClick end clips. SST Cross Tees SST Cross Tee eliminates the three-step process of competitive alternatives. The 1496 Seismic Perimeter Clip exceeds the IBC requirement for 2 ledge support Seismic Perimeter Clip Back Plate 3/8) and 3/4) dimension markers The following CMC systems grid are acceptable for use in International Building Code Seismic Design Categories: 1200 Seismic 1260 Aluminum Cap 660 Wide Face 4000 Tempra 4500 Ultraline 4600 Ultraline Contact Chicago Metallic for specific components and corresponding Seismic Design Categories. Note: Check local code for installation requirements. p6 I I chicagometallic.com Tee Attachment Screw Holes Each seismic design category has specific requirements regarding perimeter components, and our 1496 Seismic Perimeter Clip has been engineered to meet them. Current code requirements include a 2) wide perimeter wall molding, and stabilizer bars to provide support, and prevent the ceiling grid from spreading apart along the molding. Chicago Metallic s Seismic Perimeter Clip meets seismic criteria set forth by the International Building Code (IBC) to stabilize main and cross tees at the ceiling s perimeter, as detailed in ICC-ES Report # This clip ties together perimeter components and has been tested and recognized as an alternate method of stabilizing tees at the perimeter. Its robust construction allows contractors to use a sleek /16) angle in lieu of the less desirable 2) angle and eliminates costly stabilizer bars. The Perimeter Clip is easy to install. Clearly visible dimension markers on the clip show the required 3/8) or 3/4) clearance of the grid to the wall. An integral back plate accommodates the additional attachment of the clip to the wall and/or wall angle if desired, and screw holes provide easy attachment to the tee when necessary. The clip is a bright brass color, making it easily identifiable during on-site inspections. The commercial quality steel clip fits common grid components and can be used with lay-in panel ceilings.

47 Seismic Ceiling System Details SST (Seismic Separation Tee) elongated integral end tab designated seismic joint main tee staked-on stab-in end tab The Chicago Metallic SST is the only product available in the market today that has been both tested at the State University of Buffalo and reviewed by an independent, internationally renowned structural engineering group to be a viable solution for creating seismic separation joints in IBC seismic design categories D, E and F installations. Chicago Metallic s SST Seismic Separation Tee offers a ONEstep process to meeting IBC requirements. Each tee has one staked-on stab-in end tab and an opposing elongated integral end. The elongated ends of two SSTs are installed on both sides of the Main Tee that has been designated as the Seismic Joint, then locked in place with two (2) push rivets. In a seismic event, seismic forces cause the tees to move linearly, thus eliminating the need for a conventional separation joint (see photos below). In addition to the labor saved by going from the THREE-step process of returning to the assembled grid, cutting off tee clips, and installing two-piece brackets, the ONE-step SST process eliminates the need for more channels, wall angles, and additional hanger wires; does not interfere with struts, wires, push rivets lock each SST in place or ceiling panels; helps keep the grid system square, and preserves the appearance of the gridwork. The extended integral tab of the SST allows it to push towards and pull away from the designated seismic joint main tee and maintain a strong connection. The push rivets enable the joint to withstand a pullout force in excess of 180 pounds. The internal friction in the joint also provides a measure of damping. > > > > PUSH TOWARDS < < < < < < < < PULL AWAY > > > > Conventional Seismic Separation Joint To install suspended ceilings that exceed 2,500 sq. ft. in seismic zones, the IBC requires separation joints that allow cross tees to move laterally during a seismic event. Traditionally, contractors create their own seismic solutions by assembling the grid and then revisiting the assembly to cut the grid and build up conventional separation joints with tees, channels, and angles. The grid is then stabilized with additional hanger wires. In addition to increased material costs and time on the job, this multi-step process risks incurring delays while the construction method is inspected and approved. Competitive alternatives to this method include installing a two-piece bracket at main/cross tee intersections. This solution requires the contractor to install the grid, then return to the grid, cut off the cross tee tabs, and attach the bracket with screws. While the system may meet IBC requirements, it is a THREE-step component and labor intensive process. chicagometallic.com I I p7

48 IBC Seismic Catagory C Conventional IBC Installation UNATTACHED WALL CMC 1496 Clip Installation (ESR-2282) UNATTACHED WALL A-1 > < A-2 B-1 > < B-2 UNATTACHED WALL UNATTACHED WALL UNATTACHED WALL UNATTACHED WALL UNATTACHED WALL UNATTACHED WALL A-1 B-1 3/8) Min. 3/8) 1496 Clip /16) Angle 7/8) Min. Spacer Bar A-2 B-2 3/8) 3/8) Min. Spacer Bar 7/8) Min Clip /16) Angle * LEGEND 12 ga. hanger wire Horizontal Restraint (Refer to illustration on page 11) Spacer Bar p8 I I chicagometallic.com

49 IBC Seismic Catagories D, E and F Conventional IBC Installation ATTACHED WALL CMC 1496 Clip Installation (ESR-2282) ATTACHED WALL D-1 or C-1 > < C-2 D-2 > < D-3 ATTACHED WALL 12( O.C. UNATTACHED WALL ATTACHED WALL 12( O.C. UNATTACHED WALL 12( O.C. 6( max. 12( O.C. 6( max. 6( max. 6( max. UNATTACHED WALL UNATTACHED WALL C-1 Perimeter Wire (use this option or D-2 below) ± 10 from vertical Perimeter Wire ± 10 from vertical 8) Max. D-1 8) Max. 2) Min. C-2 Perimeter Wire ± 10 from vertical Pop Rivet D-2 Pop Rivet (use this option or D-1 above) Pop Rivet Perimeter Wire ± 10 from vertical /16) Angle 8) Max. 3/4) 8) Max Clip Spacer Bar 2) Min. Screw Screw /16) Angle D-3 Perimeter Wire ± 10 from vertical 3/4) from grid to inside of angle * LEGEND 12 ga. hanger wire Horizontal Restraint (Refer to illustration on page 11) Spacer Bar 1496 Clip 8) Max. /16) Angle chicagometallic.com I I p9

50 Seismic Separation Joint IBC Seismic Catagories D, E and F Conventional IBC Installation CMC SST Installation 12( O.C. E > 12( O.C. < F 12( O.C. 12( O.C. 6( O.C. max 6( O.C. max 12( O.C. 12( O.C. 12( O.C. 12( O.C. 12( O.C. 12( O.C. Seismic Joint SST rows to either side of designated seismic joint E F 1428 Angle Designated Seismic Separation Push Rivets 1-1/2) 1448 Channel 1448 Channel SST Elongated Integral Ends IMPORTANT! Do not place horizontal restraint over separation joint. * LEGEND 12 ga. hanger wire Horizontal Restraint (Refer to illustration on page 11) SST p10 I I chicagometallic.com

51 Seismic Horizontal Restraint 12 ga. hanger wire typical 4( O.C. Vertical Post 12 ga. brace wires connected to Main Tee 45 max 45 max 45 max 45 max These horizontal restraint points shall be placed 12( O.C. in both directions with the first point within 6( of each wall. Brace Wires shall be attached to Main Tees within 2) of Cross Tee intersection, at a maximum angle of 45 relative to ceiling plane. Wires shall be tied with a minimum of three tight wraps (see ASTM C 636 for examples). For complete details, please refer to the current version of ASCE 7. Vertical Struts Allowable Lengths Maximum Recommended Length for Vertical Struts 1 EMT Conduit 1/2) EMT...up to 5(10) 3/4) EMT...up to 7(8) 1) EMT...up to 9(9) Metal Studs Single 1-5/8) metal stud (20 gauge)... up to 12(0) Single 2-1/2) metal stud (20 gauge)... up to 13(6) Back-to-back 1-5/8) metal stud (20 gauge)... up to (0) Back-to-back 2-1/2) metal stud (25 gauge)... up to (0) Note: Plenum areas greater than (0) will require engineering calculations. 1 Source: Northwest Wall & Ceiling Bureau Rev. 4/07 chicagometallic.com I I p11

52 Chicago Metallic Ceiling Products Metal Perimeter Trim/ Curvilinear / Flat Metal Panel / Embossed Metal Panel / Linear / Open Plenum / Security Panel Premium / Utility / Controlled Environment Grid General Applications / Special Applications / Drywall Applications Ceiling Systems and Specialty Products - USA and Canada: / Fax: / chicagometallic.com b e lg i u m / d e n m a r k / u k / g e r m a n y / f r a n c e / h o n g ko n g / p r c / m a l ay s i a / u n i t e d a r a b e m i r at e s / m e x i c o Chicago Metallic and its logo are Registered Trademarks of Chicago Metallic Corporation. Ultraline, Tempra, QuickClick and SST are trademarks of Chicago Metallic Corporation Chicago Metallic Corporation All Rights Reserved Printed in USA SNL0027A1411 Literature Disclaimer: Presentations in this brochure or any other Chicago Metallic Corporation publication are correct to the best of our knowledge at time of preparation. We provide this information in an advisory capacity only. Any advisory recommendations given in our publications must be modified to conform with local codes, conditions and specifications. We reserve all rights to amend any information published in our literature without additional notice. Chicago Metallic can not be held responsible or liable for the selection nor application of our products.

53 CEILING SUSPENSION SYSTEMS Fast. Easy. Customer Focused. Special a p p l i c at i o n s BarrierGrid Controlled Environment 260/280 (Hook) / 1260/1280 (Stab) /16 Aluminum Cap 660 Wide Face (Stab) Aluminum Cap 1-3/8 730 All Stainless Steel (Hook) / All Aluminum (Hook) / HDG G 60 Steel/Aluminum Cap (Stab) /16 PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 1

54 Special Applications Contents 1-3/8 BarrierGrid /16 BarrierGrid /16 1-3/8 /16 Premium Standard Aluminum Cap Steel (Alum Cap option) Stainless Steel BarrierGrid BarrierGrid Premium (Stab) 1-3/8 BarrierGrid Standard (Hook) /16 Environmental Systems /280 (Hook) / 1260/1280 (Stab) Aluminum Cap /16 /16 /16 1-3/8 DynaGlass All Aluminum HDG G 60 Steel/Alum Cap FRP Wide Face (Stab) Steel (optional Aluminum Cap) 1-3/ All Stainless Steel (Hook) / All Aluminum (Hook) / HDG G 60 Steel/Aluminum Cap (Stab) / Product Cross Reference Guide Service Notes General Conditions of Sale Product Updates chicagometallic.com PRODUCT UPDATES Up-to-date product information for Special Applications products is available at chicagometallic.com in the Literature Section of each applicable system. Other Chicago Metallic Suspension Systems Refer to the General Applications product guide for fire-rated and non-rated suspension systems that are designed for general use areas. Refer to the Drywall Applications product guide for suspension systems for flat and curved drywall as well as SpanFast time saving system for corridors and smaller spaces. 2 Special Applications Ceiling Suspension Systems

55 BarrierGrid (Hook/Stab) Controlled Environment Systems BarrierGrid Controlled Environment System Non-Fire Rated Double Web Direct Hung Exposed Premium (Stab) Gasketed Wall Channel 1 3 / / 2 BarrierGrid components and assemblies are created for clean process areas requiring isolation from the ceiling plenum. Whether selecting a standard or premium system, precision placement of factory-applied gaskets ensures integrity. Applications Components and assemblies designed for use in ISO controlled environment facilities (previously Fed Standard 209E). Features / Benefits Double gasketed aluminum wall angle and channel / Provide tight closures at perimeters and minimize the need for caulking. Aluminum capped / Inhibits corrosion, giving longer product life and better appearance over time. Flame Spread Rating / Chicago Metallic suspension systems meet a Class-A flame spread rating in accordance with ASTM standard E Installation Features / Benefits Factory-applied gaskets / Precision placement of gaskets on grid flanges eliminates voids at panel modules and speeds up installation. Stab-in cross tees / Tees cantilever during installation and will not fall out, making for an easier installation. Protects against lateral pull-out. Hook cross tees / Tees snap into place and insure quick, positive installation at both ends. Butt cut cross tees / Butt cut cross tees allow ceiling panels to lay flat in suspension system, providing a better appearance and sealing. Double web construction / Increased strength for better durability. Demountable / Hook cross tees (standard system) allow large areas of ceiling to be opened easily. Gasketed Main Tee Standard (Hook) Gasketed Wall Channel Gasketed Main Tee Gasketed Cross Tee (stab) 1 1 / 2 / 16 Gasketed Cross Tee (hook) IMPORTANT! A Metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed. 14 USA and Canada: / fax: / chicagometallic.com 3

56 BarrierGrid (Hook/Stab) Controlled Environment Systems Component Slotting and Hanger Hole Placement All overall lengths shown are nominal dimensions. Hanger Holes: MAIN TEES 3 /4 each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots. CROSS TEES 3 /4 each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots, in all cross tees having slots AG Main Tee: 24 slots 6 O.C AG Main Tee: 12 slots 12 O.C AG Cross Tee (hook-type): Three slots, one at midpoint and two spaced 12 each side of midpoint AG (stab-type) Tee: Three slots, one at midpoint and two spaced 12 each side of midpoint AG Cross Tee (hook-type): No cross tee slots AG and AG (stab-type) Tees: No cross tee slots AG (stab-type) Tee: One slot at midpoint. 4 Special Applications Ceiling Suspension Systems

57 BarrierGrid (Hook/Stab) Controlled Environment Systems Components 200 Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level /16 Standard BarrierGrid Main Tee AG / 2 / 16 HD Cross Tees - Hook AG / 2 / AG / 2 / Cross Tees - Stab AG / 2 / AG / 2 / Wall Molding AG / Wall Channel AG / /8 Premium BarrierGrid* Main Tee AG / / 8 HD Cross Tee - Stab AG / / AG / / Wall Molding AG / Wall Channel AG / * Cleanroom-type light fixtures must be used with this 1 3 /8 system PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 5

58 BarrierGrid (Hook/Stab) Controlled Environment Systems Component Performance Data Component Load Test Data (based on 1 / 360 span deflection) Component Load Test Data (based on 1 / 360 span deflection) /16 Standard BarrierGrid Exposed Gasketed ALLOWABLE LOAD per ASTM C 635 Hanger Spacing Main Tee Length HD Cross Tee Length To convert data into lb/ft 2, divide on center spacing of component into lb/ft. Limited by safety factor of 2. Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures. 1-3/8 Premium BarrierGrid Exposed Gasketed ALLOWABLE LOAD per ASTM C 635 Hanger Spacing Main Tee Length HD Cross Tee Length To convert data into lb/ft 2, divide on center spacing of component into lb/ft. Limited by safety factor of 2. Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures. 6 Special Applications Ceiling Suspension Systems

59 BarrierGrid (Hook/Stab) Controlled Environment Systems Specification Data BarrierGrid Premium Standard suspension type 1-3/8 /16 material body HD Galvanized hot dipped galv hot dipped galv cap aluminum aluminum size width 1-3/8 /16 height 1 1/2 1 1/2 fire fire rated 1 performance heavy duty per ASTM C 635 demountable seismic zones / categories 3, 4 / D, E, F 2 3, 4 / D, E, F 2 warranty 40 year limited sustainability Minimum 25% recycled content, 100% locally recyclable, global/regional manufacture 1 - Traditional grid products have a Class A approved, factory painted, baked-on finish. 2 - Applies to Stab-in component systems only. Contact CMC for specific requirements. Palletization Product Cartons Weight LF Number Per Pallet Per Pallet Per Pallet Main Tees AG 20 2,250 6, AG 20 1,600 4,800 4 Ft. Cross Tees AG 30 1,470 6, AG 30 1,296 4, AG 30 1,470 6,000 2 Ft. Cross Tees AG , AG 40 1,040 3, AG ,000 Wall Angle AG ,760 Wall Channel AG ,360 PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 7

60 Specifications BarrierGrid (Hook/Stab) Controlled Environment Systems /16 Standard BarrierGrid PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for lay-in acoustical panel ceiling Related Sections A. Section Suspension Systems B. Section Specialty Ceilings C. Section Integrated Ceiling Assemblies D. Section Sound, Vibration, and Seismic Control E. Section Central Heating Equipment F. Section Lighting 1.03 References A. American Society for Testing and Materials (ASTM) 1. C635 - Standard Specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels Submittals A. Product data sheets listing dimensions, load carrying capacity and standards compliance. B. 12 inch long samples of Main Tees and Cross Tees with integral couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area receiving suspension system prior to installation. 2. Wet trades work to be thoroughly dry and complete prior to installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic double web Heavy duty non-fire rated ceiling suspension system Suspension System Components A. Main Tees: 1. Manufactured from commercial quality inch thick HDG-30 steel, hot-dip galvanized steel, /16 inch wide by 1 1 /2 inches high with factory punched cross tee slots, hanger holes, and integral bayonet-style end couplings. 2. Capped with aluminum capping affixed to /16 inch wide flange. 3. Coated with factory applied baked-on enamel paint from manufacturer s standard selection. B. Cross Tees: 1. Manufactured from commercial quality (0.010) (0.0) steel /16 inch wide by 1 1 /2 inch high by (24)(48) inches long with factory punched cross tee slots, hanger holes, and (Stab-in)(demountable hook) couplings. 2. Capped identical to main tees. 3. Finish identical to main tees. C. Gasket Material: 1. Gasket must be machine applied within (.050) of the edge of the tee. Gasket must have a 1/8 overhang on all cross tees. 2. Gasket material is a closed cell PVC foam and is conformable to both smooth and irregular surfaces, sealing against water, moisture, dirt and air-infiltration when compressed 30%. PVC foam gasket resists UV oxidation, mildew and fungus. 3. Gasket properties include elastomeric construction, PVC foams adjust to thermal movement of mating structural elements without leaking and remain flexible. 4. Gasketing is dimensionally stable and will not drip, ooze, or run when under compression. Gasket remains flexible at low temperatures, has excellent chemical resistance and forms an acoustic seal. 5. Gasketing has an average density of 8 lb./cu. ft. and a compression deflection of 2 psi (per ASTM D-1667). D. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from commercial quality steel with aluminum capped hemmed edges finished identical to main tees and cross tees. 2. Channel Molding: Manufactured from commercial quality steel with aluminum capped hemmed edges finished identical to main tees and cross tees. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Main Tees: Installed (36) (48) (60) (96) inches on center, by direct suspension from existing structure, with not less than 12 gage steel hanger wires, wrapped tightly 3 full turns, spaced (48) (60) inches on center along component length. B. Cross Tees: 1. Installed perpendicular to main tees (12)(20)(24)(30)(48)(60)(72)(96)(120) inches on center to form by modules. 2. Installed perpendicular to module forming cross tees (12)(20)(24)(30) inches on center to form by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. C. (Angle) (Channel) Moldings: Installed on vertical surfaces, intersecting suspension components by appropriate method in accordance with industry accepted practice. D. Additional Hanger Wires: Wrapped tightly 3 full turns to structure and components at locations where imposed loads could cause deflection exceeding 1 /360 span Repair A. Remove damaged components, replace with undamaged components. Clean with non-solvent based nonabrasive commercial cleaning solution. 1-3/8 Premium BarrierGrid 8 Special Applications Ceiling Suspension Systems PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for lay-in acoustical panel ceiling Related Sections A. Section Suspension Systems B. Section Specialty Ceilings C. Section Integrated Ceiling Assemblies D. Section Sound, Vibration, and Seismic Control E. Section Central Heating Equipment F. Section Lighting 1.03 References A. American Society for Testing and Materials (ASTM) 1. C635 - Standard Specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels Submittals A. Product data sheets listing dimensions, load carrying capacity and standards compliance. B. 12 inch long samples of Main Tees and Cross Tees with integral couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area receiving suspension system prior to installation. 2. Wet trades work to be thoroughly dry and complete prior to installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic double web Heavy duty non-fire rated ceiling suspension system Suspension System Components A. Main Tees: 1. Manufactured from commercial quality inch thick HDG-30 steel, hot-dip galvanized steel, 1 3 /8 inch wide by 1 1 /2 inches high with factory punched cross tee slots, hanger holes, and integral bayonet-style end couplings. 2. Capped with aluminum capping affixed to 1 3 /8 inch wide flange. 3. Coated with factory applied baked-on enamel paint from manufacturer s standard selection. B. Cross Tees: 1. Manufactured from commercial quality (0.010) (0.0) steel 1 3 /8 inch wide by 1 1 /2 inch high by (24)(48) inches long with factory punched cross tee slots, hanger holes, and Stab-in couplings. 2. Capped identical to main tees. 3. Finish identical to main tees. C. Gasket Material: 1. Gasket must be machine applied within (.050) of the edge of the tee. Gasket must have a 1/8 overhang on all cross tees. 2. Gasket material is a closed cell PVC foam and is conformable to both smooth and irregular surfaces, sealing against water, moisture, dirt and air-infiltration when compressed 30%. PVC foam gasket resists UV oxidation, mildew and fungus. 3. Gasket properties include elastomeric construction, PVC foams adjust to thermal movement of mating structural elements without leaking and remain flexible. 4. Gasketing is dimensionally stable and will not drip, ooze, or run when under compression. Gasket remains flexible at low temperatures, has excellent chemical resistance and forms an acoustic seal. 5. Gasketing has an average density of 8 lb./cu. ft. and a compression deflection of 2 psi (per ASTM D-1667). D. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from commercial quality steel with aluminum capped hemmed edges finished identical to main tees and cross tees. 2. Channel Molding: Manufactured from commercial quality steel with aluminum capped hemmed edges finished identical to main tees and cross tees. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Main Tees: Installed (36) (48) (60) (96) inches on center, by direct suspension from existing structure, with not less than 12 gage steel hanger wires, wrapped tightly 3 full turns, spaced (48) (60) inches on center along component length. B. Cross Tees: 1. Installed perpendicular to main tees (12)(20)(24)(30)(48)(60)(72)(96)(120) inches on center to form by modules. 2. Installed perpendicular to module forming cross tees (12)(20)(24)(30) inches on center to form by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. C. (Angle) (Channel) Moldings: Installed on vertical surfaces, intersecting suspension components by appropriate method in accordance with industry accepted practice. D. Additional Hanger Wires: Wrapped tightly 3 full turns to structure and components at locations where imposed loads could cause deflection exceeding 1 /360 span. E. HEPA Filters and light fixtures must be supported by 4 hanger wires. One on each corner of the fixture Repair A. Remove damaged components, replace with undamaged components. Clean with non-solvent based nonabrasive commercial cleaning solution.

61 Aluminum Cap 260/280 (Hook) /1260 /1280 (Stab) Environmental Systems Aluminum Cap Systems 260 / / 1280 Aluminum Cap 260/280 (Hook) 1 1 / 2 Non-Fire Rated / Fire Rated Double Web Direct Hung Exposed / 16 Exposed aluminum cap 260/280 hook and 1260/1280 stab are designed for use with lay-in acoustical panels. These /16 face systems are extremely versatile and offer appropriate corrosion resistance for interior environments. Applications Can be used with standard lay-in panels, revealed edge, concealed and routed geometric panels. Economical, but a quality system. Features / Benefits Aluminum capped / Inhibits corrosion, giving longer product life and better appearance over time. Designed for a wide variety of lay-in panels / Provides full ceiling accessibility. Wide range of possible modular configurations / Offers additional design possibilities. Available in a select range of painted and reflective colors / Many design possibilities as panel can be matched or contrasted. Total interior concept. Sustainability / Minimum 25% post consumer recycled content, 100% locally recyclable. Flame Spread Rating / Chicago Metallic suspension systems meet a Class-A flame spread rating in accordance with ASTM standard E Installation Features / Benefits Stab-in cross tees / Tees cantilever during installation and will not fall out, making for an easier installation. Protects against lateral pull-out. Hook cross tees / Tees snap into place and insure quick, positive installation with instant access to the plenum. Butt cut cross tees (260/280, reflective systems only) / Butt cut cross tees allow ceiling panels to lay flat in suspension system, providing a better appearance, especially with metal panels. QuickClick end clips / Quick, easy tee installation with an audible click signalling firm engagement. Double web construction / Increased strength for better durability. Seismic Perimeter Clip (1280 System Only) / Allows for a visually appealing ceiling with the use of a /16 angle in seismic zones C, D, E and F. Accommodates standard NEMA Type-G lights and air diffusers / Allows for integration of lighting and air supply without creating additional labor. Aluminum Cap 1260/1280 (Stab) International Building Code (IBC) Seismic Category C, D, E & F Alternative Perimeter Treatment using 1496 Perimeter Clip IMPORTANT! A Metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed. / / 2 20 USA and Canada: / fax: / chicagometallic.com 9

62 Aluminum Cap 260/280 (Hook)/1260 /1280 (Stab) Environmental Systems Component Slotting and Hanger Hole Placement All overall lengths shown are nominal dimensions. Hanger Holes: MAIN TEES 3 /4 each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots. CROSS TEES 3 /4 each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots, in all cross tees having slots. 260/280 /16 Aluminum Cap 260 & 280 Main Tees: 24 cross tee slots 6 O.C. 264 Cross Tee: 3 cross tee slots 12 O. C. 262 Cross Tee: No cross tee slots. 1260/1280 /16 Aluminum Cap 260 & 280 Main Tees: 24 cross tee slots 6 O.C Cross Tee: 3 cross tee slots 12 O. C Cross Tee: No cross tee slots. Reflective Finish /16 Aluminum Cap 200 Main Tee: 24 cross tee slots 6 O.C Cross Tee: 3 cross tee slots 12 O.C Cross Tee: No cross tee slots. 10 Special Applications Ceiling Suspension Systems

63 Aluminum Cap 260/280 (Hook) /1260 /1280 (Stab) Environmental Systems Components Non-Reflective Aluminum Cap Fire Rated Systems Available Non-Reflective Aluminum Cap Colors (01) White (08) Black (44) Satin Silver Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level 260/280 System Main Tees AH / 2 / 16 ID AH / 2 / 16 HD Cross Tees - Hook - Butt Cut AH / 2 / AH / 2 / Wall Angle 262 No slots No slots AH 12 x 3 / 4 x / Hanger Wire 96CTL straight bundled /1280 System Main Tees AH / 2 / 16 ID AH / 2 / 16 HD Cross Tees - Stab - Overide AH / 2 / AH / 2 / Seismic Perimeter Clip - For use with 1280 System in Category C, D, E and F installations Wall Angle AH 12 x 3 / 4 x / Reflective Aluminum Cap Non-Fire Rated System No slots PRODUCT chicagometallic.com UPDATES Available Reflective Aluminum Cap Colors Reflective System Only: (14) Chromecoat (16) Brasscoat Main Tee 200.( )AH / 2 / 16 ID Cross Tee - Stab - Butt Cut 1229.( )AH / 2 / ( )AH / 2 / Wall Angle 1409.( )AH 12 x 3 / 4 x / Hanger Wire 96CTL straight bundled 50 0 USA and Canada: / fax: / chicagometallic.com 11

64 Aluminum Cap 260/280 (Hook)/1260 /1280 (Stab) Environmental Systems Component Performance Data Component Load Test Data (based on 1 / 360 span deflection) 260/280 Aluminum Cap / 16 Exposed Fire Rated Assemblies ALLOWABLE LOAD per ASTM C 635 Hanger Spacing Main Tee Length ID HD Cross Tee Length To convert data into lb/ft 2, divide on center spacing of component into lb/ft. Limited by safety factor of 2. Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Fixture weight based on single fixtures only and are covered in the table. Refer to specific design numbers for allowable number of fixtures per square footage of ceiling area. 1260/1280 Aluminum Cap / 16 Exposed ALLOWABLE LOAD per ASTM C 635 Hanger Spacing Main Tee Length ID HD Cross Tee Length To convert data into lb/ft 2, divide on center spacing of component into lb/ft. Limited by safety factor of 2. Light Fixture Load Test Data (based on 1 / 360 span deflection) LIGHT FIXTURES MAIN & CROSS TEES - ALLOWABLE FIXTURE WT. LBS. 260/ / Dimensions x x x Limited by safety factor of Special Applications Ceiling Suspension Systems

65 Aluminum Cap 260/280 (Hook)/1260 /1280 (Stab) Environmental Systems Specification Data suspension type Aluminum Cap Aluminum Cap Aluminum Cap Aluminum Cap material body HD Galvanized cap aluminum aluminum aluminum aluminum size width /16 /16 /16 /16 height 1 1/2 1 1/2 1 1/2 1 1/2 fire fire rated 1 performance heavy duty per ASTM C 635 intermediate duty per ASTM C 635 demountable seismic zones / categories 1, 2 / A, B, C 1, 2 / A, B, C 3, 4 / D, E, F 3, 4 / C, D, E, F warranty 40 year limited sustainability Minimum 25% recycled content, 100% locally recyclable, global/regional manufacture 1 - Traditional grid products have a Class A approved, factory painted, baked-on finish. Reflective finishes are not fire rated. Palletization Product Cartons Weight LF Number Per Pallet Per Pallet Per Pallet Main Tees AH 28 1,988 8, AH 28 2,324 8, H 28 2,044 8,400 4 Ft. Cross Tees AH 40 1,700 8, H 40 1,806 6, AH 2 Ft. Cross Tees Packaged To Order AH 50 1,600 7, AH 50 1,600 7,500 PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 13

66 Specifications 260/280 (Hook)/1260 /1280 (Stab) Environmental Systems 260/280 Aluminum Cap / 16 Exposed PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for lay-in acoustical panel ceiling Related Sections A. Section Suspension Systems B. Section Specialty Ceilings C. Section Integrated Ceiling Assemblies D. Section Sound, Vibration, and Seismic Control E. Section Central Heating Equipment F. Section Lighting 1.03 References A. American Society for Testing and Materials (ASTM) 1. C635 - Standard Specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels Submittals A. Product data sheets listing dimensions, load carrying capacity and standards compliance. B. 12 inch long samples of Main Tees and Cross Tees with integral couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area receiving suspension system prior to installation. 2. Wet trades work to be thoroughly dry and complete prior to installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic double web (Intermediate) (Heavy) duty rated ceiling suspension system Suspension System Components A. Main Tees: 1. Manufactured from commercial quality steel / 16 inch wide by 1 1 / 2 inches high by 144 inches long with factory punched cross tee slots, hanger holes, and integral bayonet-style end couplings. 2. Capped with aluminum capping affixed to / 16 inch wide flange. 3. Coated with factory applied standard (architect select color) baked-on enamel paint. B. Cross Tees: 1. Manufactured from commercial quality steel / 16 inch wide by 1 1 / 2 inch high with factory punched cross tee slots, hanger holes, and integral hook-type grid end couplings. 2. Capped identical to main tees. 3. Finish identical to main tees. C. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from inch thick steel with aluminum capped hemmed edges, finished identical to main tees and cross tees. 1260/1280 Aluminum Cap / 16 Exposed PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for lay-in acoustical panel ceiling Related Sections A. Section Suspension Systems B. Section Specialty Ceilings C. Section Integrated Ceiling Assemblies D. Section Sound, Vibration, and Seismic Control E. Section Central Heating Equipment F. Section Lighting 1.03 References A. American Society for Testing and Materials (ASTM) 1. C635 - Standard Specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels Submittals A. Product data sheets listing dimensions, load carrying capacity and standards compliance. B. 12 inch long samples of Main Tees and Cross Tees with integral couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area receiving suspension system prior to installation. 2. Wet trades work to be thoroughly dry and complete prior to installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic double web (Intermediate) (Heavy) duty rated ceiling suspension system Suspension System Components A. Main Tees: 1. Manufactured from commercial quality steel / 16 inch wide by 1 1 / 2 inches high by 144 inches long with factory punched cross tee slots, hanger holes, and integral bayonet-style end couplings. 2. Capped with aluminum capping affixed to / 16 inch wide flange. 3. Coated with factory applied standard (architect select color) baked-on enamel paint. B. Cross Tees: 1. Manufactured from commercial quality steel / 16 inch wide by 1 1 / 2 inch high with factory punched cross tee slots, hanger holes, and integral stab-in grid end couplings. 2. Capped identical to main tees. 3. Finish identical to main tees. C. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from inch thick steel with aluminum capped hemmed edges, finished identical to main tees and cross tees. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Main Tees: Installed 48 inches on center, by direct suspension from existing structure, with not less than 12 gage steel hanger wires, wrapped tightly 3 full turns, spaced 48 inches on center along component length. B. Cross Tees: 1. Installed perpendicular to main tees 48 inches on center to form 24 inch by 48 inch modules. 2. Installed adjacent to each unsupported side of recessed fixtures. C. Angle Moldings: Installed on vertical surfaces, intersecting suspension components by appropriate method in accordance with industry accepted practice. D. Additional Hanger Wires: Wrapped tightly 3 full turns to structure and components at locations where imposed loads could cause deflection exceeding 1 / 360 span Repair A. Remove damaged components, replace with undamaged components. Clean with non-solvent based nonabrasive commercial cleaning solution. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Main Tees: Installed 48 inches on center, by direct suspension from existing structure, with not less than 12 gage steel hanger wires, wrapped tightly 3 full turns, spaced 48 inches on center along component length. B. Cross Tees: 1. Installed perpendicular to main tees 48 inches on center to form 24 inch by 48 inch modules. 2. Installed adjacent to each unsupported side of recessed fixtures. C. Angle Moldings: Installed on vertical surfaces, intersecting suspension components by appropriate method in accordance with industry accepted practice. D. Additional Hanger Wires: Wrapped tightly 3 full turns to structure and components at locations where imposed loads could cause deflection exceeding 1 / 360 span Repair A. Remove damaged components, replace with undamaged components. Clean with non-solvent based non-abrasive commercial cleaning solution. 14 Special Applications Ceiling Suspension Systems

67 660 Wide Face (Stab) Environmental Systems 660 Wide Face 660 (Stab) Non-Fire Rated Double Web Direct Hung Exposed 1 3 / / 2 Aluminum capping provides corrosion resistance and added protection in harsh environments. Applications Wide face allows expression of the grid modules at high elevations. Features / Benefits Extra wide 1-3/8 flange / Eliminates potential for unsightly gaps and conceals chipped or imperfect ceiling panel edges reducing waste. Available in a wide range of painted colors / Many design possibilities as panels can be matched or contrasted. Total interior concept. Sustainability / Minimum 25% post consumer recycled content, 100% locally recyclable. Flame Spread Rating / Chicago Metallic suspension systems meet a Class-A flame spread rating in accordance with ASTM standard E International Building Code (IBC) Seismic Category C, D, E & F Alternative Perimeter Treatment using 1496 Perimeter Clip Installation Features / Benefits Stab-in cross tees / Tees cantilever during installation and will not fall out, making for an easier installation. Protects against lateral pull-out. Double web construction / Increased strength for better durability. Seismic Perimeter Clip / Allows for a visually appealing ceiling with the use of a /16 angle in seismic zones C, D, E and F. Accommodates standard NEMA Type-G lights and air diffusers / Allows for integration of lighting and air supply without creating additional labor. IMPORTANT! A Metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed. 26 USA and Canada: / fax: / chicagometallic.com

68 660 Wide Face (Stab) Environmental Systems Components Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level Steel with 01 White Aluminum Cap Main Tees A / / 8 HD Cross Tees - Stab - Overide A / / A / / Wall Channel x 1 9 / 16 x / Wall Angle AH 12 x 3 / 4 x / Note: Other Colors are available for this system. Contact CMC Customer Service for additional information Accessories Hold Down Clip Adjusts to ceiling board height Perimeter Clip For 1 1 / 2 height components Seismic Perimeter Clip - For use in Category C, D, E and F installations Hanger Wire 96CTL144 12, straight bundled 50 0 Touch-Up Paint 940.xx 12 oz. spray can 01 White Special Applications Ceiling Suspension Systems

69 660 Wide Face (Stab) Environmental Systems Component Slotting and Hanger Hole Placement All overall lengths shown are nominal dimensions. Hanger Holes: MAIN TEES 3 /4 each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots. CROSS TEES 3 /4 each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots, in all cross tees having slots. 664 Cross Tee: 1 cross tee slot at midpoint. 640 Main Tee: 18 cross tee slots 8 O.C. 662 Cross Tee: No cross tee slots. Component Performance Data Component Load Test Data (based on 1 / 360 span deflection) / 8 Exposed Non-Fire Rated Assemblies ALLOWABLE LOAD per ASTM C635 Hanger Spacing Main Tee Length HD Cross Tee Length To convert data into lb/ft 2, divide on center spacing of component into lb/ft. Weight limited by a safety factor of 2. Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures. Specification Data suspension type 660 Wide Face material body HD Galvanized cap Aluminum size width 1 3/8 fire fire rated 1 height 1 1/2 performance heavy duty per ASTM C 635 intermediate duty per ASTM C 635 demountable seismic zones / categories 3, 4 / C, D, E, F warranty 40 year limited sustainability Minimum 25% recycled content, 100% locally recyclable, global/regional manufacture Palletization Product Cartons Weight LF Number Per Pallet Per Pallet Per Pallet Main Tee A 28 2,184 6,720 4 Ft. Cross Tee A 40 1,680 8,000 2 Ft. Cross Tee A 50 1,100 4,000 Wall Angles ,220, Palletized To Order 1 - Tempra grid products have a Class A approved, factory painted, baked-on finish. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 17

70 Specifications 660 Wide Face (Stab) Environmental Systems 660 Wide Face 1 3 / 8 Exposed PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for lay-in acoustical panel ceiling Related Sections A. Section Ceiling Suspension Systems B. Section Special Ceiling Surfaces C. Section Integrated Ceilings D. Section Sound, Vibration, and Seismic Control E. Section Heating, Ventilating, and Air Conditioning F. Section Lighting 1.03 Reference A. American Society for Testing and Materials (ASTM) 1. C635 - Standard specification for the manufacture, performance, and testing of metal suspension systems for acoustical tile and lay-in panel ceilings. 2. C636 - Standard practice for installation of metal ceiling suspension systems for acoustical tile and lay-in panels Submittals A. Product data sheets: listing dimensions, load carrying capacity and standard compliance. B. Samples: 12 inch long samples of main runner and cross tee with couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area to receive suspension system prior to installation. 2. Wet trades work to be thoroughly dry and complete prior to installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and air conditioning systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic 660 Exposed Heavy Duty double web suspension system Suspension System Components A. Main Tees: 1. Manufactured from inch thick Hot Dipped Galvanized steel 1-3/8 inch wide by 1-1/2 inches high by 144 inches long with factory punched cross tee slots, hanger holes, and integral bayonet-style end couplings. 2. Capped with aluminum capping affixed to 1-3/8 inch flange. 3. Coated with factory applied standard white baked-on enamel paint finish. B. Cross Tees: 1. Manufactured from inch thick steel (/16) (1-3/8) wide by 1-1/2 inches high by (24) (48) (60) inches long with factory punched cross tee slots and hanger holes. 2. Capped with aluminum capping affixed to (/16) (1-3/8) inch flange. 3. Coated identical to main runners. C. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from (0.020) (0.024) inch thick steel (3/4) (/16) (1-1/2) inch wide by (/16) (1-1/2) inch high by 144 inches long with (hemmed edges) (straight edges) finished identical to main and cross tees. 2. Channel Molding: Manufactured from inch thick steel /16 inch wide by 1-9/16 inch high by 120 inches long with hemmed edge finished identical to main and cross tees. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Main Tees: Installed (48) (60) inches on center, by direct suspension from existing structure, with not less than 12 gage hanger wires spaced 48 inches on center along main runner length. Wrap hanger wires tightly 3 full turns at each end. B. Cross Tees: 1. Installed perpendicular to main tees (24) (48) inches on center to form by modules. 2. Installed perpendicular to module forming cross tees to form by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. C. (Angle) (Channel) moldings: Installed on vertical surfaces, intersecting suspension components, by appropriate method in accordance with industry accepted practice. D. Additional Hanger Wires: Wrapped tightly 3 full turns to structure and component at locations where imposed loads, could cause deflection exceeding 1/360 span Repair A. Remove damaged components, replace with undamaged components. 18 Special Applications Ceiling Suspension Systems

71 730 All Stainless Steel (Hook) Environmental Systems 730 All Stainless Steel Non-Fire Rated Double Web Direct Hung Exposed 730 (Hook) / / 2 Performance systems are designed for areas that have high moisture levels or corrosive elements in the environment. The 730 System is roll formed entirely from stainless steel and is the most resistant to corrosion. Chicago Metallic s 730 All Stainless Steel Ceiling System components are manufactured to meet performance criteria of severe environmental conditions. Due to the inherent qualities of raw materials and manufacturing processes, slight imperfections or variations may occur on the exposed surface of this product. These variations will not affect the functional performance capabilities of the suspension components. Applications Can be used with standard lay-in or revealed edge panels. Features / Benefits Corrosion resistant 304 stainless steel / No paint or coating to peel, corrode, stain or pit for longer product life and better appearance over time. Demountable / Allows for quick access to large work areas above the ceiling. Matching stainless steel panels / Specify 2B Finish for grid and panels. Flame Spread Rating / Chicago Metallic suspension systems meet a Class-A flame spread rating in accordance with ASTM standard E Installation Features / Benefits Hook cross tees / Tees snap into place and insure quick, positive installation at both ends with instant access to plenum. Butt cut cross tees / Butt cut cross tees allow ceiling panels to lay flat in suspension system, providing a better appearance. Meets seismic requirements / Complete seismic zone and category coverage when used with available stainless steel clip. Double web construction / Increased strength for greater versatility and durability. Components shipped with strippable plastic film / Film protects face and ensures clean installation. Removed after installation. IMPORTANT! A Metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed. 30 Special Applications Ceiling Suspension Systems 19

72 730 All Stainless Steel (Hook) Environmental Systems Component Slotting and Hanger Hole Placement All overall lengths shown are nominal dimensions. Hanger Holes: MAIN TEES 3 /4 each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots. CROSS TEES 3 /4 each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots, in all cross tees having slots. 730 Main Tee: 12 cross tee slots 12 O.C. 734 Cross Tee: 3 cross tee slots, 1 at midpoint, one 12 each side of midpoint. 732 Cross Tee: No cross tee slots. Components Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level Main Tee SB / 2 / 16 ID Cross Tees - Hook - Butt Cut SB / 2 / SB / 2 / Intersection Clip For installation in areas requiring seismic restraint 732 No slots Locks cross tees to main tees Wall Angle SB 12 x 7 / 8 x 7 / Hanger Wire CTL straight bundled Special Applications Ceiling Suspension Systems

73 730 Stainless Steel (Hook) Environmental Systems Component Performance Data 730 Stainless Steel ALLOWABLE LOAD per ASTM C 635 Hanger Spacing Main Tee Length ID Cross Tee Length To convert data into lb/ft 2, divide on center spacing of component into lb/ft. Limited by safety factor of 2. Component Load Test Data (based on 1 / 360 span deflection) Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures. Light Fixture Load Test Data (based on 1 / 360 span deflection) LIGHT FIXTURES MAIN & CROSS TEES - ALLOWABLE FIXTURE WT. LBS. 730 Dimensions x x x Limited by safety factor of 2. Specification Data suspension type 730 All Stainless Steel Palletization Product Cartons Weight LF Number Per Pallet Per Pallet Per Pallet material body stainless cap stainless size width /16 height 1 1/2 performance intermediate per ASTM C 635 light duty per ASTM C 635 demountable seismic zones / categories 3, 4 / D, E, F 1 warranty 40 year limited Main Tee SB 28 2,170 8,400 4 Ft. Cross Tee SB 40 2,000 8,000 2 Ft. Cross Tee SB 50 1,900 7,500 Wall Angle S 40 1,760 12, Contact CMC for specific requirements. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 21

74 Specifications 730 (Hook) Environmental Systems 730 All Stainless Steel PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for lay-in acoustical panel ceiling Related Sections A. Section Ceiling Suspension Systems B. Section Special Ceiling Surfaces C. Section Integrated Ceilings D. Section Sound, Vibration, and Seismic Control E. Section Heating, Ventilating, and Air Conditioning F. Section Lighting 1.03 Reference A. American Society for Testing and Materials (ASTM) 1. C635 - Standard specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard practice for installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels Submittals A. Product data sheets listing dimensions, load carrying capacity and standard compliance. B. Samples: 12 inch long samples of main tee and cross tee Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area to receive suspension system prior to installation. 2. Wet trades work to be thoroughly dry and complete prior to suspension system installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and Air Conditioning Systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. B. Cross Tees: 1. Manufactured from 0.0 inch thick 304 Stainless Steel alloy /16 inch wide by 1 1 /2 inches high by (24) (48) inches long with integral snap-grid end couplings, factory punched cross tee slots, and hanger holes. 2. Capped identical to main tees. C. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from inch thick Stainless Steel alloy /16 inch wide by 3 /4 inch high by 144 inches long with hemmed edges finished identical to main tees and cross tees. PART 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied. To assure a clean installation and save time in the cleaning process, manufacturer recommends the use of clean, protective hand coverings to eliminate any excessive residue appearing on the surface of the product during the installation procedure Installation A. Main Tees: Installed 48 inches on center, by direct suspension from existing structure, with not less than 12 gage electrogalvanized hanger wires spaced 48 inches on center along main runner length. Wrap hanger wires tightly 3 full turns at each end. B. Cross Tees: 1. Installed perpendicular to main tees 24 inches on center to form 24 inch by 48 inch modules. 2. Installed perpendicular to cross tees to form by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. C. Angle Moldings: Installed on vertical surfaces, intersecting suspension components, by appropriate method in accordance with industry accepted practice. D. Additional Hanger Wires: Wrapped tightly 3 full turns to structure and component at locations where imposed loads could cause deflection exceeding 1 / 360 span Repair A. Remove damaged components, replace with undamaged components. Clean with mild soap and water. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic 730 Stainless Steel, Intermediate Duty Double Web Suspension System Suspension System Components A. Main Tees: 1. Manufactured from 0.0 inch thick 304 Stainless Steel alloy /16 inch wide by 1 1 /2 inches high by 144 inches long with factory punched cross tee slots, hanger holes, and capped with base 304-2D Stainless Steel. 22 Special Applications Ceiling Suspension Systems

75 830 All Aluminum (Hook) Environmental Systems All Aluminum 830 (Hook) 830 (Hook) 1 1 / 2 Non-Fire Rated Double Web Direct Hung Exposed / 16 Performance systems are designed for areas that have high moisture levels or corrosive elements in the environment. The 830 System is manufactured completely from aluminum. It has a Light Duty ASTM classification and is best suited for high moisture areas. Applications Can be used with standard lay-in or revealed edge panels. Features / Benefits Corrosion resistant aluminum / Provides a longer product life and better appearance over time. Demountable / Allows for quick access to large work areas above the ceiling. Sustainability / 100% post consumer recycled content, 100% locally recyclable. Flame Spread Rating / Chicago Metallic suspension systems meet a Class-A flame spread rating in accordance with ASTM standard E Installation Features / Benefits Hook cross tees / Tees snap into place and insure quick, positive installation at both ends. Butt cut cross tees / Butt cut cross tees allow ceiling panels to lay flat in suspension system, providing a better appearance. Meets seismic requirements / Complete seismic zone and category coverage when used with available stainless steel clip. Double web construction / Increased strength for greater versatility and durability. IMPORTANT! A Metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed. 34 USA and Canada: / fax: / chicagometallic.com 23

76 830 All Aluminum (Hook) Environmental Systems Component Slotting and Hanger Hole Placement All overall lengths shown are nominal dimensions. Hanger Holes: MAIN TEES 3 /4 each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots. CROSS TEES 3 /4 each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots, in all cross tees having slots. 830 Main Tee: 12 cross tee slots 12 O.C. 834 Cross Tee: 1 cross tee slot at midpoint. 832 Cross Tee: No cross tee slots. Components Available Aluminum Cap Colors (01) White (08) Black (44) Satin Silver 830 Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level Main Tee A / 2 / 16 LD Cross Tees - Hook - Butt Cut A / 2 / No slots A / 2 / Intersection Clip For installation in areas requiring seismic restraint 416. Locks cross tees to main tees Hold Down Clip Adjusts to different height ceiling boards Wall Angle A 12 x 3 / 4 x / Hanger Wire CTL straight bundled Special Applications Ceiling Suspension Systems

77 830 All Aluminum (Hook) Environmental Systems Component Performance Data 830 All Aluminum ALLOWABLE LOAD per ASTM C 635 Hanger Spacing Main Tee Length ID Cross Tee Length To convert data into lb/ft 2, divide on center spacing of component into lb/ft. Component Load Test Data (based on 1 / 360 span deflection) Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures. Light Fixture Load Test Data (based on 1 / 360 span deflection) LIGHT FIXTURES MAIN & CROSS TEES - ALLOWABLE FIXTURE WT. LBS. 730 Dimensions x x x Limited by safety factor of 2. Specification Data suspension type 830 All Stainless Steel Palletization Product Cartons Weight LF Number Per Pallet Per Pallet Per Pallet material body aluminum cap aluminum size width /16 height 1 1/2 performance intermediate per ASTM C 635 light duty per ASTM C 635 demountable seismic zones / categories 3, 4 / D, E, F 1 warranty 40 year limited sustainability Aluminum: 100% recycled content, 100% locally recyclable, global manufacture Main Tee A 28 1,190 8,400 4 Ft. Cross Tee A 40 1,080 8,000 2 Ft. Cross Tee A 50 1,000 7,500 Wall Angle A , Contact CMC for specific requirements. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 25

78 Specifications 830 (Hook) Environmental Systems 830 All Aluminum PART 1 - GENERAL 1.01 Section Includes Provide metal suspension system for lay-in acoustical panel ceiling Related Sections A. Section Ceiling Suspension Systems B. Section Special Ceiling Surfaces C. Section Integrated Ceilings D. Section Sound, Vibration, and Seismic Control E. Section Heating, Ventilating, and Air Conditioning F. Section Lighting 1.03 Reference A. American Society for Testing and Materials (ASTM) 1. C635 - Standard specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard practice for installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels Submittals A. Product data sheets listing dimensions, load carrying capacity and standard compliance. B. Samples: 12 inch long samples of main tee and cross tee with couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area to receive suspension system prior to installation. 2. Wet trades work to be thoroughly dry and complete prior to suspension system installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and Air Conditioning Systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic 830 Aluminum Light Duty Double Web Suspension System Suspension System Components A. Main Tees: 1. Manufactured from inch thick Aluminum /16 inch wide by 1 1 /2 inches high by 144 inches long with factory punched cross tee slots, hanger holes, and integral end couplings. 2. Capped with (white aluminum) (satin silver aluminum) (black aluminum) capping affixed to /16 inch flange. B. Cross Tees: 1. Manufactured from inch thick Aluminum /16 inch wide by 1 1 /2 inches high by (24)(48) inches long with integral snap-grid end couplings, factory punched cross tee slots, and hanger holes. 2. Capped identical to main tees. C. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from inch thick Aluminum /16 inch wide by 3 /4 inch high by 144 inches long with hemmed edges finished identical to main tees and cross tees. 26 Special Applications Ceiling Suspension Systems

79 Aluminum Cap HDG Steel 1830 (Stab) Environmental Systems Hot Dipped Galvanized Steel with Aluminum Cap 1830 (Stab) 1830 (Stab) 1 1 / 2 Fire Rated Double Web Direct Hung Exposed / 16 Performance systems are designed for areas that have high moisture levels or corrosive elements in the environment. The 1830 System is similar to the 830 System but the body is made from G-60 hot dipped galvanized steel with an aluminum capped face. The 1830 System offers corrosion resistance similar to the 830 System - but with the advantage of being Intermediate Duty and Fire Rated. Ideal for parking garages. Applications Can be used with standard lay-in or revealed edge panels. Features / Benefits Corrosion resistant HDG (G-60) steel / Provides a longer product life and better appearance over time. Sustainability / Steel: 25% minimum, aluminum: 100% post consumer recycled content, 100% locally recyclable. Flame Spread Rating / Chicago Metallic suspension systems meet a Class-A flame spread rating in accordance with ASTM standard E Installation Features / Benefits Stab-in cross tees / Tees cantilever during installation and will not fall out, making for an easier installation. Protects against lateral pull-out. Meets seismic requirements / Complete seismic zone and category coverage. Fire rated system / Expansion reliefs are built into each main tee to compensate for elongation of the materials during fire. Double web construction / Increased strength for greater versatility and durability. IMPORTANT! A Metallurgist should be consulted regarding the suitability of this product for the environmental conditions in which it is being installed. 38 USA and Canada: / fax: / chicagometallic.com 27

80 Aluminum Cap HDG Steel 1830 (Stab) Environmental Systems Component Slotting and Hanger Hole Placement All overall lengths shown are nominal dimensions. Hanger Holes: MAIN TEES 3 /4 each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots. CROSS TEES 3 /4 each side of cross tee slot, and 2 additional holes equally spaced between cross tee slots, in all cross tees having slots Main Tee: 24 cross tee slots 6 O.C Cross Tee: 3 cross tee slots, 1 at midpoint, one 12 each side of midpoint Cross Tee: No cross tee slots. Components Available Aluminum Cap Colors (01) White (08) Black (44) Satin Silver Product Dimensions ASTM Per Carton Service Number Length Height Face Duty Feet Pieces Weight Level No slots Main Tee AH / 2 / 16 ID Cross Tees - Hook - Butt Cut AH / 2 / AH / 2 / Intersection Clip For installation in areas requiring seismic restraint 416. Locks cross tees to main tees Hold Down Clip Adjusts to different height ceiling boards Wall Angle A 12 x 3 / 4 x / Hanger Wire 96CTL straight bundled Special Applications Ceiling Suspension Systems

81 Aluminum Cap HDG Steel 1830 (Stab) Environmental Systems Component Performance Data Component Load Test Data (based on 1 / 360 span deflection) 1830 Aluminum Cap HDG G 60 Steel ALLOWABLE LOAD per ASTM C 635 Hanger Spacing Main Tee Length ID Cross Tee Length To convert data into lb/ft 2, divide on center spacing of component into lb/ft. Limited by safety factor of 2. U.L. Fire Rated Assemblies floor-ceiling type 1830 A202, A210, D203, D205, D209, D2, D216, G022, G201, G208, G209, G210, G211, G213, G214, G2, G216, G217, G218, G222, G228, G234, G241, G242, G244, G248, G250, G255, G256, G258, G259, J201, L201, L202, L206, L208, L209, L210, L211, L212 roof-ceiling type 1830 P201, P202, P203, P204, P206, P207, P210, P211, P214, P2, P216, P217, P219, P225, P227, P228, P229, P230, P231, P235, P237, P238, P239, P241, P244, P245, P246, P251, P253, P255, P257, P259, P260, P261, P262, P264 Non-Fire Rated Assemblies Hanger Positions for Non-Fire Rated Situations This illustrates hanger positions for single fixtures in a field. Provide extra hangers for tandem fixtures. Fire Rated Assemblies Hanger Positions for Fire Rated Situations This illustrates hanger positions for single fixtures in a field and are covered in the table. Refer to specific design numbers for allowable number of fixtures per square footage of ceiling area. Specification Data suspension type 1830 Aluminum Cap HDG Steel material body HDG G 60 cap aluminum size width /16 height 1 1/2 fire fire rated 1 performance intermediate per ASTM C 635 light duty per ASTM C 635 demountable seismic zones / categories 3, 4 / D, E, F 2 warranty 40 year limited sustainability Aluminum: 100%; steel-minimum 25% recycled content, 100% locally recyclable, global manufacture Palletization Product Cartons Weight LF Number Per Pallet Per Pallet Per Pallet Main Tee AH 28 2,268 8,400 4 Ft. Cross Tee AH 40 2,080 8,000 2 Ft. Cross Tee AH 50 1,950 7,500 Wall Angle A , Traditional grid products have a Class A approved, factory painted, baked-on finish. 2 - Contact CMC for specific requirements. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 29

82 Specifications Environmental Systems 1830 (Stab) 1830 Aluminum Cap HDG Steel PART 1 - GENERAL 1.01 Section Includes Provide Metal Suspension System for Lay-in Acoustical Panel Ceiling Related Sections A. Section Ceiling Suspension Systems B. Section Special Ceiling Surfaces C. Section Integrated Ceilings D. Section Sound, Vibration, and Seismic Control E. Section Heating, Ventilating, and Air Conditioning F. Section Lighting 1.03 Reference A. American Society for Testing and Materials (ASTM). 1. C635 - Standard specification for the manufacture, performance, and testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings. 2. C636 - Standard practice for installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in panels. B. Underwriters Laboratories (U.L.) Fire Resistance Directory (latest edition) Submittals A. Product Data Sheets listing dimensions, load carrying capacity and standards compliance. B. Samples: 12 inch long samples of main tee and cross tee with couplings Project Conditions A. Environmental Requirements: 1. Verify weather tightness of area to receive suspension system prior to installation. 2. Wet trades work to be thoroughly dry and complete prior to suspension system installation. 3. Installation to begin only when temperature and humidity conditions closely approximate interior conditions which will exist when area is complete and occupied. 4. Heating and Air Conditioning Systems to be operating prior to, during, and after installation Maintenance Furnish additional material equal to percent of ceiling area. PART 2 - PRODUCTS 2.01 Manufacturers Chicago Metallic Fire Front 1830 Intermediate Duty Fire Rated Double Web Suspension System Suspension System Components A. Main Tees: 1. Manufactured from 0.0 inch thick hot dipped galvanized steel /16 inch wide by 1 1 /2 inches high by 144 inches long with factory punched cross tee slots, hanger holes and integral end couplings. 2. Capped with (white aluminum) (satin silver aluminum) (black aluminum) capping affixed to /16 inch flange. 3. Manufactured with fire expansion reliefs on fire rated components in accordance with Chicago Metallic illustrated details. B. Cross Tee: 1. Manufactured from 0.0 inch thick hot dipped galvanized steel /16 inch wide by 1 1 / 2 inches high by (24) (48) inches long with factory punched cross tee slots, hanger holes, and integral stab-in end couplings. 2. Capped identical to main tees. 3. Manufactured with fire expansion reliefs on fire rated components. C. Perimeter Treatment Components: 1. Angle Moldings: Manufactured from inch thick hot dipped galvanized steel /16 inch wide by 3 /4 inch high by 144 inches long with hemmed edges finished identical to main tees and cross tees. Part 3 - EXECUTION 3.01 Examination Examine area receiving suspension system to identify conditions which will adversely affect installation. Do not begin installation until adverse conditions have been remedied Installation A. Suspension System Components: Installed in accordance with U.L. design number guidelines. B. Main Tees: Installed 48 inches on center, by direct suspension from existing structure, with not less than 12 gage electrogalvanized hanger wires spaced 48 inches on center along main tee length. Wrap hanger wires tightly 3 full turns at each end. C. Cross Tees: 1. Installed perpendicular to main tees 24 inches on center to form 24 inch by 48 inch modules. 2. Installed perpendicular to module forming cross tees to form by modules. 3. Installed adjacent to each unsupported side of recessed fixtures. D. Angle Moldings: Installed on vertical surfaces, intersecting suspension components, by appropriate method in accordance with industry accepted practice. E. Additional Hanger Wires: Wrapped tightly 3 full turns to structure and component at locations where imposed loads could cause deflection exceeding 1 /360 span Repair Remove damaged components, replace with undamaged components. Clean with non-solvent based nonabrasive commercial cleaning solution. 30 Special Applications Ceiling Suspension Systems

83 Product Cross Reference Guide Product Cross Reference Guide Chicago Metallic AWI USG General Application Grid 200 Snap-Grid Prelude ML 250 Fire-Front Snap-Grid 1200 Seismic Prelude XL DX 1250 Fire-Front Seismic Prelude XL Fire Guard DXL Fire Rated 4000 Tempra Suprafine XL DXT Centricitee 4050 Tempra Fire Rated Suprafine XL Fire Guard DXLT Centricitee 3500 Ultraline Silhouette XL 1/4 Reveal DXF Fineline 1/ Ultraline Fire Rated Silhouette XL Fire Guard 1/4 DXF Fineline 1/ Ultraline Silhouette XL 1/8 Reveal DXF Fineline 1/8 Special Application Grid BarrierGrid Standard Clean Room Controlled Environment BarrierGrid Premium Clean Room Controlled Environment 260/280 Aluminum Cap 1260/1280 Aluminum Cap Prelude XL DXLA Aluminum Cap / 8 Wide Face DXW 730 Stainless SS Prelude Plus XL DXSS 830 Aluminum AL Prelude Plus XL AX All Aluminum 1830 HDG-60 Prelude XL Exterior ZXLA Hot Dipped Drywall Grid 640/660 Drywall Grid 650/670 Fire Rated Drywall Grid Fire Guard Drywall Suspension SpanFast ShortSpan Wall-to-Wall PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 31

84 32 Special Applications Ceiling Suspension Systems

85 Service Levels, Support & Samples Service Service Levels Service Levels represents the approximate time in weeks for an order to be ready to ship from the manufacturing plant. Add 2 weeks to all Service Levels for CMC transfer truck to Baltimore or Los Angeles Service Centers. Service Level begins when the following criteria are met Receipt of acceptable Purchase Order, Credit Approval, Drawing Approval, Color Approval. Service Levels Production Lead Time 0 Stock item available for immediate shipment 1 Available to ship within 1 week of order acceptance 2 Available to ship within 2 weeks of order acceptance 3 Available to ship within 3 weeks of order acceptance 4 Available to ship within 4 weeks of order acceptance 5 Available to ship within 5 weeks of order acceptance 6 Available to ship within 6 weeks of order acceptance?? Contact Chicago Metallic for current lead time Color Samples 1. Custom color matching requires customer color sample or paint manufacturer and color number. 2. CMC will provide color sample for approval upon request. 3. Service Level begins after receipt of color approval. Order Placement and General Customer Service Support Phone: / option 1 Fax: cmc-customerservice@chicagometallic.com Standard Samples and Literature Standard literature, product samples and color samples are available from the CMC Sample and Literature department at no charge. Phone: / option 2 Fax: samples@chicagometallic.com Technical Support Requests for technical information on CMC Metal Ceilings may be placed with the Technical Services Department. Phone: option 3 Fax: cmc-customerservice@chicagometallic.com Mockups and Custom Samples When CMC has agreed to provide custom samples or mockups, the cost for them will be billed to the account. CMC will be glad to issue credit upon request for all mockups and custom sample invoices when valid orders for these products are placed with our Customer Service Department. Phone: Fax: cmc-customerservice@chicagometallic.com PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 33

86 34 Special Applications Ceiling Suspension Systems

87 General Conditions of Sale General Conditions of Sale Order Acceptance Whenever used herein, Seller shall refer to Chicago Metallic Corporation and Purchaser shall refer to the party ordering or purchasing products ( Products ) from Seller. Seller s price list does not constitute an offer to sell Products listed therein, but is simply provided as a convenience to prospective Purchasers. Purchaser s order to Seller shall constitute an offer to Seller to purchase Products which offer Seller may accept at its sole discretion. Acceptance shall be by a writing containing these General Conditions of Sale ( Conditions ). Acceptance of Purchaser s order or any part of it by Seller is expressly made conditional on Purchaser s assent to these Conditions. Purchaser may vary these Conditions only with the written consent of Seller. Acceptance of Products by Purchaser or failure of Purchaser to object in writing to these Conditions within ten (10) days following delivery of Products to Purchaser shall constitute Purchaser s assent to these Conditions. Shipment and Delivery Seller shall deliver Product F.O.B. place of shipment. Risk of loss to Product shall pass to Purchaser upon delivery to carrier at such place of shipment. Carrier acts as Purchaser s agent. Products shall be shipped as soon as practical, or as requested by Purchaser after order acceptance by Seller. However, delivery dates shall not be of the essence, but shall be regarded as Seller s best approximation of such delivery dates. Seller may arrange freight at the request of and on behalf of Purchaser. If applicable, freight will be charged according to the Seller s freight policy in effect at time of shipment. Such policy will be provided to Purchaser via its preferred communication method and is also available in Seller s price book or upon request. All taxes, tariffs, duties or similar charges paid by Seller imposed or levied by any governmental authority in connection with the purchase, shipment, import or export of Products purchased or in connection with the procuring of materials used therein may at Seller s sole option be added to the price of Products so affected. Additional shipping charges for Products paid by Seller such as destination, storage, labor and redelivery and special or extra expenses for handling air freight, bus or other shipments may also, at Seller s sole option, be added to the price of such Products. Payment Payment for all Products shall be net cash due and payable in U.S. dollars within thirty (30) days following receipt by Purchaser of shipping documents for such Products by check or bank transfer to a bank account to be designated by Seller. If accounts are paid within ten (10) days following receipt by Purchaser of the corresponding shipping documents, Purchaser shall been entitled to a one percent (1%) discount from the price of Products only. If, in Seller s sole opinion, the financial condition of the Purchaser so warrants, Seller may require advance payments or satisfactory security. In the event that the Purchaser fails to make such advance payments or furnish such security upon Seller s request, delivery of Products may be suspended without further Seller obligation. Seller may, at Seller s sole option, require payment by means of an irrevocable letter of credit opened and confirmed by a bank or banks acceptable to Seller and upon terms and conditions acceptable to Seller. Limited Warranty Seller warrants to Purchaser that Products will substantially conform in quantity and quality to Purchaser s order, as accepted by Seller, provided, however, that (1) Products are inspected by Purchaser upon arrival at place of destination and any and all nonconformities are noted on the bill of lading and all other delivery documents and are attested to in writing by carrier s representative (2) Purchaser furnishes Seller with written notice of such non-conformities within fifteen () days following arrival of non-conforming Products at the place of destination, (3) Purchaser holds nonconforming Products for Seller s inspection (4) non-conformities occurred prior to delivery by Seller of Products F.O.B. place of shipment, and (5) Purchaser does not alter, repair, use or attempt to alter or repair any non-conforming Products. This limited warranty is Seller s only and exclusive express warranty to Purchaser. Seller disclaims any and all implied warranties including without limitation any implied warranty of merchantability or fitness for a particular purpose. Purchaser s sole and exclusive remedy against Seller shall be the replacement F.O.B. its plant or site, at Seller s option, of any Products which do not conform to Seller s limited warranty hereunder. No other remedy (including, without limitation, incidental or consequential damages for lost profits, lost sales, injury to persons or property or any other incidental or consequential loss) shall be available to Purchaser. Purchaser agrees to include in all contracts between Purchaser and subsequent owners or users of Products, and to bring to the attention of all Purchaser s customers of Products, the following warranty disclaimer: Chicago Metallic Corporation disclaims any and all warranties expressed or implied, including, without limitation, any implied warranty of merchantability or fitness for a particular purpose. Purchaser shall be excluded on behalf of Seller all remedies for damage or injury to Products persons or property. In the event that Purchaser fails to comply with the foregoing obligations, Purchaser shall indemnify Seller for any liability resulting from such non-compliance and shall otherwise hold Seller harmless. Returns In order to return any Products to Seller, Purchaser must first obtain prior authorization for products eligible for return, and receive a Return Goods Authorization number from Seller s home office. All authorized returns are subject to a 20% restocking charge. Seller will only issue credit for Service Level 0 material received at the designated company facility with the Return Goods Authorization appearing on the material, and after being inspected and determined by Seller to be in resalable condition. Purchaser is solely responsible for arranging and prepaying for all return freight. Seller will not be responsible for any damage in transit on material returned at customer s request, and will not file freight claims on such damaged material. When these terms are met, seller will issue appropriate material credit less the restocking charge. Default, Termination and Suspension of Delivery Seller reserves the right, among other remedies, either to cancel Purchaser s order or suspend further deliveries of Products thereunder in the event that (1) Purchaser fails to pay for any one shipment of Products when payment for such shipment becomes due; (2) Purchaser fails to make any advance payments or satisfactory security demanded by Seller pursuant to paragraph two of PAYMENTS section above; or (3) Purchaser fails or refuses to accept any delivery of Products ordered from Seller. Delivery of Products may be suspended in whole or in part in case of any event beyond Seller s control, including, but not limited to, explosion, fire, shortage of fuel, power or raw materials flood strike lockout, injunction, riot, insurrection, war, national emergency, government act, or act of God. Miscellaneous No failure or delay on the part of Seller in exercising any right, power or privilege hereunder shall operate as a waiver thereof or of any other right, power or privilege hereunder nor shall any single or partial exercise of any such right power or privilege preclude any other right, power or privilege. The rights or remedies of Seller hereunder are cumulative and not exclusive of any rights or remedies which it may otherwise have. The parties hereto may correct stenographic and clerical errors without liability. Purchaser may not assign the order without the express written consent of Seller. All notices to be given hereunder by either party to the other party shall be dispatched by certified or registered mail return receipt requested addressed to the last known post office address of such other party. Any such notice shall be deemed received within five (5) days following any such dispatch if mailed from within the United States of America and ten (10) days if mailed from outside the United States of America. Either party may change its address by notice to the other party. These Conditions shall be governed by and interpreted in accordance with the laws of the State of Illinois, United States of America, and all disputes hereunder that cannot be amicably resolved by the parties thereto must be settled in a court of competent jurisdiction within the State of Illinois, United States of America. The provisions of these Conditions shall be severable one from the other so that should any provision be held legally unenforceable by a court of competent jurisdiction, the remaining provisions shall remain in effect. PRODUCT chicagometallic.com UPDATES USA and Canada: / fax: / chicagometallic.com 35

88 Chicago Metallic Ceiling Products Metal Perimeter Trim/ Curvilinear / Flat Metal Panel / Embossed Metal Panel / Linear / Open Plenum / Security Panel Premium / Utility / Controlled Environment Grid General Applications / Special Applications / Drywall Applications Ceiling Systems and Specialty Products - USA and Canada: / Fax: / chicagometallic.com b e l g i u m / d e n m a r k / u k / g e r m a n y / f r a n c e / h o n g ko n g / p r c / m a l ay s i a / u n i t e d a r a b e m i r at e s / m e x i c o Chicago Metallic, its logo, Fast. Easy. Customer Focused. and QuickClick are Registered Trademarks of Chicago Metallic Corporation Chicago Metallic Corporation All Rights Reserved Printed in USA SNL0030B2111 Literature Disclaimer: Presentations in this brochure or any other Chicago Metallic Corporation publication are correct to the best of our knowledge at time of preparation. We provide this information in an advisory capacity only. Any advisory recommendations given in our publications must be modified to conform with local codes, conditions and specifications. We reserve all rights to amend any information published in our literature without additional notice. Chicago Metallic can not be held responsible or liable for the selection nor application of our products.

89 Sistema de Suspensión para Cielos Acústicos El Sistema de Suspensión Económico Ideal por su Resistencia y Estabilidad! Todos los componentes están construidos con acero logrando una mayor fuerza del sistema así como una mejor estabilidad dimensional. Todos los componentes son de Acero Galvanizado por Inmersion en Caliente. Los conectores son de acople positivo para lograr conecciones ajustadas... sin necesidad de usar herramientas El sistema de suspension ideal para usar cielo falso ligero. Se ofrece con ancho de cara estandart en /16" o diseñador angosto en 9/16". Ventas internacionales: / Fax: / chicagometallic.com

90 Sistema de Suspensión para Cielos Acústicos USO LIGERO No Clasificado como Inflamable Perfiles secundarios apoyados sobre los principales para evitar la rotación. Doble Alma 1421 /1432 Perfil Angular 1823/1825-S3221/S3231 Perfil Secundario 1812 /S3212 Perfil Principal Perfil Principal 1812 Perfil secundario 1823/1825 Perfil Principal 3212 Perfil secundario 3221/ /2 (38 mm) 1 1 /8 (28.6mm) 1 5 /16 (32 mm) 1 5 /16 (32 mm) 3 /4 (19mm) /16 (24mm) /16 (24mm) /16 (24mm) 9 /16 (14mm) 9 /16 (14mm) 7 /8 (22mm) /16 (24mm) Medidas Imperiales (Equivalentes Métricos) Código Longitud Espesor Por Caja de Producto Pies (mm) Pulgadas (mm) Pies (Metros) Piezas Pies Cúbicos Peso por Caja - Libras (Kg.) Sistema 1812 Perfil Principal Altura: 1 1 /2 (38mm) / Cara: /16 (24mm) * 1812.( ) 12 (3657.6).010 (0.25) 300 (90) (24.57) NOTA: Medidas especiales disponibles a solicitud. Perfiles Secundarios Altura: 1 1 /8 (28.6mm) / Cara: /16 (24mm) 1823.( ) 2 (609.6).010 (0.25) 0 (45) (10.49) 1825.( ) 4 (1219.2).010 (0.25) 200 (60) (13.91) Sistema S3212 Perfil Principal Altura: 1 5 /16 (32mm) / Cara: 9 /16 (14mm) * S (3048.0).012 (0.30) 350 (105) (24.40) NOTA: Medidas especiales disponibles a solicitud. Perfiles Secundarios Use (.01H) (.08H) como sufijo numéricocuando ordene. (.01H) - Blanco Acabado (.08H) - Negro Acabado Altura: 1 5 /16 (32mm) / Cara: 9 /16 (14mm) S (609.6).012 (0.30) 210 (63) (14.55) S (1219.2).012 (0.30) 280 (84) (18.62) Perfiles Angulares (Pintado: HDG) Altura: 3 /4 (19mm) / Cara: 7 /8 (22mm), Altura: /16 (24mm) / Cara: /16 (24mm) H 10 (3048.0).0 (0.38) 420 (126) (17.60) H 10 (3048.0).0 (0.38) 420 (126) (23.00) *CLASIFICACION: Uso ligero. HDG = Hot Dip Galvanized (Galvanizado en Sumersión Caliente). Perfil Angular Pintado HDG. Todos los componentes aquí descritos están disponibles en modulación métrica de 625mm con sus correspondientes ranuras a 312.5mm. Ventas internacionales: / Fax: / chicagometallic.com Oficinas para Centroamerica y Colombia, Costa Rica, Venezuela: Tel: / Fax: / alpizarj@chicagometallic.com Oficinas en México: Prolongacion Avenida Uniones, S/N, Fraccionamiento Industrial del Norte, Matamoros, Tamaulipas, Mexico / Tel: Fax: Chicago Metallic Corporation. Todos los Derechos Reservados El nombre Chicago Metallic y su logotipo son marcas registradas de Chicago Metallic Corporation. Impreso en E.E.U.U. PI sp-0107 Reserva de derechos sobre la literatura: Las presentaciones de este folleto, así como las de todas las publicaciones de Chicago Metallic Corporation, son correctas según nuestro mejor conocimiento al momento de su preparación. Proporcionamos esta información solamente en carácter de asesoramiento. Todas las recomendaciones dadas en nuestras publicaciones deberán modificarse según las necesidades, condiciones y especificaciones locales. Nos reservamos el derecho de modificar cualquier información publicada en nuestra literatura sin previo aviso. Chicago Metallic no reconocerá ninguna responsabilidad u obligación ni por la selección ni por la aplicación de nuestros productos.

91 1920 Sistema de Suspensión para Cielos Acústicos El Sistema de Suspensión Económico Ideal por su Resistencia y Estabilidad! 1920 Todos los componentes están construidos con acero logrando una mayor fuerza del sistema así como una mejor estabilidad dimensional. Todos los componentes son de Acero Galvanizado por Inmersion en Caliente. Los conectores son de acople positivo para lograr conecciones ajustadas... sin necesidad de usar herramientas El sistema de suspension ideal para usar cielo falso ligero. Ventas internacionales: / Fax: / chicagometallic.com