Anchorfix 294 DANA LIM A/S. Product Information: Reactive resin mortar; Vinylester-based, styrene free. Productdescription & use:

Size: px
Start display at page:

Download "Anchorfix 294 DANA LIM A/S. Product Information: Reactive resin mortar; Vinylester-based, styrene free. Productdescription & use:"

Transcription

1 DK Product Information: Anchorfix 294 Reactive resin mortar; Vinylester-based, styrene free. Productdescription & use: Anchorfix 294 is a styrene free mortar of high quality for chemical mounting of treaded rods in various building materials. Anchorfix 294 secures a high load. The special cartridge secures an easy and fast mixture of the product. Anchorfix 294 can be used in building materials of concrete, light concrete, massive bricks, cell bricks a.s.o. The product is approved according to: Anchorfix 294 is a styrene free mortar of high quality for chemical mounting of treaded rods in various building materials. Physical / chemical data: Adhesive: Type: Chemical curing, 2-component, styrene free Consistency Paste Durability: 18 month in an unopened package when stored dry and cool. Packaging: Item. Size Colour ml Grey Cured adhesive: Resistance: Temperature: up to +80 C, short term up to +120 C Climatic ageing: good Chemical resistance: high Anchorfix Revideret Side 1/6 DANA PU Vinterskum Revideret Side 1/2

2 Instructions for concrete & solid stone: Use: Heavy load-carrying attachments in solid stone, concrete, porous concrete and light concrete Suitable for attachment points close to the edge, since anchoring is free of expansion forces Also suitable as repair mortar or adhesive mortar for concrete components. Attachment of anchor rods, threaded collars, reinforcement bars, profiles etc. Benefits: Can be used in various solid stones Galvanised steel, stainless steel, high-corrosionresistant steel. Cartridge can be used up to the end of the validity date by replacing the static mixer or resealing cartridge with the sealing cap. Water-impermeable joint, i.e. no water can penetrate into the hole at the side of the adhesive compound. Accurate dosage of the compound by means of scaling. Temperature: Application: Can be applied when the temperature of the cartridge is +20 C. 1. Drill hole with percussion drill 2. Clean drill hole (blow out: 4x, brush out: 4x, blow out: 4x) 3. Screw mixer to cartridge 4. Squeeze out and discard approx. 10 cm of compound before use 5. Starting from the back end, fill hole completely with mortar 6. Push anchor up to base of hole whilst turning it slightly 7. Visual check of mortar 8. Observe curing time 9. Install component, apply torque Anchorfix Revideret Side 2/6

3 Performance data / standard application in concrete: Design values Resin Temperature Anchor M 8 M 10 M 12 M 16 M 20 M 24 M 27 M C / 40 C N Rk [kn] 20,1 33,9 49,8 75,4 128,2 174,2 203,6 237,5 Tension load N Rd [kn] 11,2 18,8 27,6 41,9 71,2 96,8 113,1 131,9 50 C / 80 C N Rk [kn] 15,1 25,4 37,3 56,5 96,1 134,6 152,7 171,5 N Rd [kn] 8,4 14,1 20,7 31,4 53,4 74,8 84,8 95,3 Safety factor for tension loads 1.8 acc. to ETAG V Rk [kn] 9,8 16,0 22,9 43,2 67,5 97,2 128,1 155,7 Steel quality V Shear load 5.8 Rd [kn] 7,9 12,8 18,3 34,6 54,0 77,8 102,5 124,6 Rec. Torque 12,7 25,6 45,1 117,1 229,0 394,8 597,4 800,5 (rek. Moment?) V Rk [kn] 13,8 22,4 32,0 60,5 94,5 136,1 179,3 218,0 Steel quality V Rd [kn] 8,8 14,4 20,5 38,8 60,6 87,2 115,0 139,7 A4 Rec. Torque 14,3 28,7 50,5 177,3 256,3 442,9 670,1 898,0 Safety factor for share loads 1.25 for 5.8 & 1.56 for A4 acc. to ETAG Recommended loads Resin Concrete M 8 M 10 M 12 M 16 M 20 M 24 M 27 M 30 Tension load Shear load Installation parameters 24 C / 40 C N rec. [kn] 8,0 13,5 19,7 29,9 50,9 69,1 80,8 94,2 50 C / 80 C N rec [kn] 6,0 10,1 14,8 22,4 38,1 53,4 60,6 68,1 Steel quality V rec [kn] 5,6 9,1 13,1 24,7 38,6 55,5 73,2 89,0 5.8 Steel quality V rec [kn] 6,3 10,3 14,7 27,7 43,3 62,3 82,1 99,8 A4 Edge distance C cr,n [mm] , Min. edge distance C min [mm] Aksial distance S cr,n [mm] Min. aksial distance S min [mm] Anchor depth h ef [mm] Min. partthickness h min [mm] Tread diameter D [mm] Drill diameter d B [mm] Hole diameter in part d Bau [mm] ,5 17, Tightening torgue T inst. [Nm] Anchorfix Revideret Side 3/6

4 Instructions for hollow brick: Use: Used for medium-load applications. The injection plug can be used in hollow brick Hlz 4 to DIN 105, sand-lime hollow brick KSL 4 to DIN 106, hollow light concrete brick Hbl 2 to DIN and hollow concrete brick Hbn 4 to DIN Suitable for attachment of façades, projecting roofs, wooden constructions, metal constructions, metal profiles, consoles, railings, grills, sanitary fittings, pipe connections, cable runs etc. Benefits: Temperature: Application: Secure anchoring in hollow brick; high load-bearing capacity. No expansion effect, allowing attachment points to be placed close to edges etc. Cartridge can be used up to the end of the validity date by replacing the static mixer or resealing cartridge with the sealing cap Can be used when the temperature of the cartridge is +20 C. 1. Drill hole without percussion drill 2. Clean drill hole (blow out: 2x, brush: 2x, blow out: 2x) 3. Screw mixer to cartridge 4. Squeeze out and discard approx. 10 cm of compound before use 5. Insert perforated sleeve 6. Starting from the back end, fill perforated sleeve with mortar 7. Push anchor up to base of sleeve whilst turning it slightly 8. Observe curing time 9. Install component, apply torque Anchorfix Revideret Side 4/6

5 Performance data / standard application for hollow brick: Recommended loads Standard sleeve Approved sleeve Stone Hollow brick Sand-line hollow brick Styrke klasse M 6 M 8 M 10 M 12 M 8 M 10 Hlz 4 0,3 0,3 0,3 0,3 0,3 0,3 Hlz 6 F rec [kn] 0,4 0,4 0,4 0,4 0,4 0,4 Hlz 12 0,7 0,8 0,8 0,8 0,8 0,8 KSL 4 0,3 0,3 0,3 0,3 0,3 0,3 KSL 6 F rec [kn] 0,4 0,4 0,4 0,4 0,4 0,4 KSL 12 0,7 0,8 0,8 0,8 0,8 0,8 Sand-line solid brick KSL 12 F rec [kn] 0,5 1,7 1,7 1,7 1,7 1,7 Solid brick Mz 12 F rec [kn] 0,5 1,7 1,7 1,7 1,7 1,7 Light concrete hollow brick Hbl 2 F rec [kn] 0,3 0,3 0,30 0,3 Hbl4 0,5 0,6 0,6 0,6 Concrete hollow brick Hbn 4 F rec [kn] 0,5 0,6 0,6 0,6 Standard sleeve 9x50 X 13x85 [mm] x x X 13x130 x X Approved sleeve SH 13x100 [mm] x SH 15x100 X Installation parameters Standard sleeve Approved sleeve Aksial distance plug S cr,n [mm] Hlz, KSL, Mz, KS = group Hbl, Hbn = 200 Min. aksial distance Min S [mm] Hlz, KSL, Mz, KS = plug group Hbl, Hbn = 100 Aksial distance S singl. [mm] between single plugs Dge distance C cr,n [mm] In. Edge distance Min. C [mm] Drilling depth h ef [mm] Drilling depth without h ef [mm] sleeve Min. partthickness h min [mm] Drill diameter d b [mm] Hole diameter in part d bau [mm] Tightening torgue T Inst. [Nm] Curing process Temperature Curing starte Curing end dry Curing end wet underground underground -5 C 90 min. 840 min min. 0 C 45 min. 420 min. 840 min. +5 C 25 min. 120 min. 240 min. +10 C 15 min. 80 min. 160 min. +20 C 6 min. 45 min. 90 min. +30 C 4 min. 25 min. 50 min. +35 C 2 min. 20 min. 40 min. Anchorfix Revideret Side 5/6

6 Characteristic properties: Bending tensile strength and compression strength: Sample preparation and testing carried out in accordance with EN 196 Part 1; strength determination Bending tensile strength and compression strength were tested on three samples, size 40 x 40 x 160 mm. Load increase to test bending tensile strength: (50 ± 10) N/s Load increase to test compression strength: (2400 ± 200) N/s Table 1. Bending tensile strength and compression strength Sample no. Age of sample on day of Raw density Bending tensile strength Compression strength testing [Kg/dm 3 ] [N/mm 2 ] [N/mm 2 ] 1 24 timer 1, timer 1, timer 1, Mean value 1, Dynamic elasticity module: The dynamic elasticity module was determined on the basis of the resin proportion over the sound duration. The results are shown in Table 2 below: Table 2. Dynamic elasticity module of samples 40x40x160 mm Sample no. Raw density Edyn after 24 hours [Kg/dm 3 ] [N/mm 2 ] 1 1, , , Mean value 1, Energy at break: Sample preparation and testing carried out in accordance with EN 196 Part 1; strength determination. Bending tensile strength and compression strength were tested on five samples, while at the same time determining the energy at break at the relevant maximum load. Sample size 40 x 40 x 160 mm. Test speed, in variance to DIN EN 196: 1 mm/min. Table 3. Bending tensile strength and compression strength, energy at break Age of sample at testing Properties Extreme values Average valuet Variation co-efficient % Bending strength 15,90 20,50 18,7 9,13 Energy at break at 1,17 2,15 1,81 20,40 maximum force in bending trial Nm Compression 89,50 97,60 93,40 3,63 Energy at break at maximum force in compression trial Nm 199,8 283,5 239,60 14,10 Cleaning: Safety: Labelling: Tools should be cleaned adhesive removed either by Wipes 915 or turpentin. Cured anchorfix can only be removed mechanically. Hands and skin is washed with water and soap. Xi, irritant For further information please see the safety datasheet for the product. The information and data contained in this Product Information sheet are based on extensive laboratory testing and our practical experiences, and are meant for helping the user to find optimum working methods. As the conditions at the user are beyond our control, we make no warranties concerning the results, achieved by the products. The information s in this Product Information sheet are typical values, intended as a guideline. They should not be regarded as product specifications. Please also refer to our standard sales conditions and terms of delivery. DANA LIM A/S - KØBENHAVNSVEJ DK-4600 KØGE DENMARK INFO@DANALIM.DK PH. (+45) TELEFAX (+45) TECHNICAL SERVICE PH. (+45) Anchorfix Revideret Side 6/6