About Art s Way. Company History

Size: px
Start display at page:

Download "About Art s Way. Company History"

Transcription

1

2 About Art s Way Company History Iowa farmer Arthur Luscombe founded Art's Way Manufacturing in 1956, to produce and sell a PTO powered grinder mixer he developed on his farm near Dolliver, Iowa. His first product was a great success that marked the beginning of his amazing career as an inventor and entrepreneur. In 1959, Luscombe moved the company from his original plant in downtown Armstrong to its present location, and the grinder mixer line was expanded to include OEM work for companies such as Massey Ferguson, Owatonna and Case or as it was known then, International Harvester. Today, Art's Way has approximately 200 employees and operates its 3 business units in multiple facilities across Iowa and more recently South Dakota. Arthur Luscombe's dedication to innovation, quality and durability remains the central focus of our products and business practices. In 2002, Art s Way diversifies its business by creating the new Art s Way Scientific division in Monona, Iowa. This division manufactures modular agricultural buildings and modular laboratories for research. Over the past 20 years, this division has put nearly 2,000 agricultural units into operation

3 Why Choose Modular Building? Speedy Delivery Durable Construction Factory Assembled Completely Fiberglass Sealed Interior Easy to Clean and Disinfect Effective Ventilated Environment Low Maintenance High Resale Value Can Relocate

4 Site Preparations Building Comes Ready To Set On 12 Dia. Piers 4 High Above The Ground. Piers Shall Be Leveled With A Transit. Pour Piers Below Local Frost Line. Typical Frame Anchor System Building Set on Piers

5 Modular Wall Construction Structural Insulated Panels (SIPs) are expanded polystyrene (EPS) foam between one piece of Oriented Strand Board (OSB) and one piece of ½ plywood; glued together under pressure with a structural adhesive. A 4 ½ panel will give you a R19 value with no air leaks

6 Typical Building Cross Section

7 Reinforced Fiberglass Walls and Pit Completely Water Tight Interior Walls Have 1 Layer Of 50 Fiberglass Matting With A Gelcoat Finish Over Entire Surface. Ceilings Have 1 Layer Of 4 Fiberglass Matting At Plywood Seams With A Gelcoat Finish Over Entire Surface. Pit Has Been Designed For A100% Leak Free System. All Seams Are Overlapped For Double Protection Corners Have 45 Degree Cove Trim For Easy Cleanup

8 Scraper System Durable Stainless Steel Scraper System Plastic Blades Provide Clean Scraping And Floor Protection Heavy Duty Power Unit W/ 1 Hp Motor. Drive Unit With Forward And Reverse Switch. Blades Roll Up On Runners When Reversed

9 Plumbing System Medicator System And Hose Bibs Presoak System Water Entrance Water Heater (Optional) Water Connection For Waters Sweep Drains Pressure Reducer Gauge Plumbing Stubbed Through Floor Pull Plug

10 Electrical System Electrical Panel is water tight exterior style panel. Building is supplied with a surge protection system, located in panel box. All electrical wires are installed in pvc conduit, sealed, and caulked. All plugs and switches are water tight style and surfaced mounted. All fluorescent lighting fixtures are waterproof w/ T-8 energy efficient lights. Buildings to be grounded on site. Electrical System meets National Electrical Codes.

11 Ventilation Chart Animal Type MWPS VENTILATION CHART Recommended Ventilation for Heat Produced (CFM/Head) Animals Btu/Hr/Hd Cold Mild Hot Required BTU Farrowing 0 1, ,000 Nursery Finishing B/G Sows ,000 Boars ,000 Veal Calves Free Stall 0 1, Broilers Chart Based meets ISO 9001 standards

12 Farrowing Building - Ventilation System Cool Cell Interior TJW Vent Inlets Varifan Control Heat/Humidity Probe Fan w/ Fan Gate Open Vent C2000 Ceiling Inlet LB White Heater Multifan Fan w/ Hood Air Flow In Bldg. Air Flow In Attic. Air Flow Leaving

13 Cast Iron Flooring System Cast Iron Flooring With Interlocking System 5 Fiberglass Reinforced Support Beam

14 Diagonal Farrowing Crate More usable creep space for the piglets Heat zone farther away from sows for better sow comfort Easy access to crate at birthing Reduces crushing with anti-crush bars Simple crate length adjustments One water pan serves 2 crates

15 Standard 16 Wide Diagonal Crate Building Standard 16 Wide Diagonal Crate Farrowing Building Stainless Steel Diagonal Crates, Sow Trough, and Water Pan Interlocking Cast Iron Slats on 5 Fiberglass Support Beams. 10 Gallon Electric Water Heater. Outlets For Heat Lamps 24 Fiberglass Wash Tub Complete Ventilation Package Pre-Soak System Self Contained Pit Scraper System 12 Steel I-beam Frame

16 Farrowing Building - Diagonal Crate

17 Farrowing Building Rear Load Crate

18 Standard Nursery / Grower Building Self Contained Pit Stainless Steel Feeders And Solid Shaft Nursery Gating Stainless Steel Cup Waterers L.B. White Heaters Pre-soak System Scraper System 12 Steel I-beam Frame Complete Ventilation Package

19 hd Nursery / Grower Building

20 hd Nursery / Grower Building

21 Gestation Building

22 Boar Building

23 Boar Stud Building w/ Laboratory

24 Head Split Calf Building

25 Various Project History Arkansas State University - 2 Ag Southern Illinois University - 1 Ag Oklahoma State University - 14 Ag University of Michigan - 12 Research Duke University - 3 Research University of Illinois - 7 Ag University of California - 1 Research University of Florida - 3 Research IUPUI - 3 Ag Ohio State University - 4 Research Cal Poly University - 1 Ag University of Missouri - 3 Ag Florida Atlantic - 1 Research USDA - 4 Research Kansas State University - 1 Ag Mississippi State University - 2 Ag University of Minnesota - 8 Ag Iowa State University - 7 Ag University of North Dakota - 1 Ag University of Nebraska - 1 Ag University of North Carolina - 1 Ag Virginia Tech - 5 Ag California State University-1 Ag Northeast Iowa Community College-1 Ag Hawkeye Community College-2 Ag Colorado State University-2 Ag University of Georgia-1 Ag ADM-9 Ag Nearly 2,000 buildings constructed since

26 Leasing Options Allison Leasing Co. 503 West A St., Ste. B P.O. Box Lincoln, NE Phone: (402) LEASE FAX: (402) Midwest Leasing, Inc. 37 Kubler Court PO Box 1214 Crested Butte, CO (800)

27 We Stand Behind Our Products WARRANTY Art s-way Scientific warrants to the Owner that materials and equipment furnished under the Contract will be of good quality and new, unless otherwise required or permitted by the Contract Documents, that the Work will be free from defects not inherent in the quality required or permitted, and that the Work will conform to the requirements of the Contract Documents. Work not conforming to these requirements, including substitutions not properly approved or authorized, may be considered defective. Art s-way Scientific warranty excludes remedy for damage or defect caused by abuse or modifications not executed by Art s-way Scientific, improper or insufficient maintenance, improper operation, or normal wear and tear and normal usage. If, within one (1) year after the date of Final Acceptance, or the date of Beneficial Occupancy, if the Owner occupies the facility prior to Final Acceptance and any of the Work is found to not be in accordance with the requirements of the Contract Documents, Art s-way Scientific shall correct it promptly after receipt of a written notice from the Owner to do so unless the Owner has previously given Art s-way Scientific a written acceptance of such condition. All materials and equipment not manufactured by Art s-way Scientific will carry the manufacturer s standard warranty. All such warranty documents are provided with the Final Project Submittals at the completion of installation. Using a combination of locally sourced trades and our own installers, the building is installed, seamed and sealed, then finish work completed. We are confident that we can meet or exceed your requirements

28 Contact Information