1 Data Sheet atena baffle DESCRIPTION Baffles system is made up of vertical box-shaped elements (B30/B40/B50), plain or perforated along the long sides, hooked on variable distance carriers (minimum gap 70 mm). System can be suspended using standard hangers and double spring or threated bars. For special arrangements Baffles can be installed using T-grid and its own Tilt-spin system to allow 360 rotation and vertical inclination. T-grid bearing structure can be suspended using AtenaTwister hangers. Baffles are opened on one side, while the foreheads can be closed with proper closing caps. * TS CARRIER H30 PASSO E FUGA VARIABILI * 3700 MAIN T PROFILE B24 H * 1200 CROSS T PROFILE B24 H CROSS T PROFILE B24 H32 TECHNICAL DATA: ELEMENTS DIMENSION 30x100 / 30x150 / 30x200 / 40x100 / 40x140 / 40x180 / 50x100 / 50x200 / 50x300 mm. Maximum lenght 4000 mm. *More heights on request up to 400 mm. MATERIALS White - silver pre-painted aluminum White pre-painted steel from 5/10 to 8/10* from 5/10 to 8/10* *check with the size of the chosen baffle STRUCTURE TS Carrier made up of black pre-painted or post-painted with RAL color on request 8/10 steel. T24 Structure with Tilt-spin system hooks. Antiseismic Kit on request. HANGERS Double hanger with adjustable spring or threaded bar, Atena Twister for T24. COLORS FINISHING PERFORATIONS CERTIFICATIONS: White pre-painted steel. White, silver or any RAL color post-painted aluminum. Plain or perforated surface. Sublimation of any image and texture. Perforation to chose among Atena perforations models performed on the long side of the stave. 10 mm smooth edge along the perimeter of the long side. Smooth base, smooth end caps on request. FLEXION RESISTANCE Maximum span mm Classe 1 DURABILITY OF PRE-PAINTED ITEMS DANGEROUS SUBSTANCES EMISSION REACTION TO FIRE C Class No release of any dangerous substance according to the European law EN13964:2014. According to UNI EN : plain or perforated staves with Viledon Plus Class A1 perforated with Standard Viledon A2s1d0. Structure: Class A1. Atena s.p.a. atena-it.com Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 1 of 17

2 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 2 of 17 AXONOMETRY AND SECTIONS OF TS CARRIER SYSTEM SECTION DETAIL 1200 mm LOCKING SYSTEM bend the locking wing AVAILABLE HANGERS double hanger with spring threated bar

3 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 3 of 17 CONCAVE AND CONVEX ARRANGEMENT WITH THE SHAPEABLE CARRIER. A SOLUTION At ena s.p.a. atena-it.com B SOLUTION

4 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 4 of 17 AXONOMETRY AND SECTIONS OF SHAPED CARRIER SYSTEM FOR A DISPOSAL AT DIFFERENT HEIGHTS TO OBTAIN A WAVE EFFECT SECTION DETAIL JOINT DETAIL END CAPS DETAIL

5 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 5 of 17 CORRECT THREATED BAR BRACKET INSTALLATION MODE 1 Hook the threated bar bracket on U profile. 2 2 Slide the bracket toward threated bar to hook on it. Max 8 Nm 3 Fix the threated bar bracket with its screw. 3 1 Correct fixing Wrong fixing AVAILABLE HANGERS threated bar

6 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 6 of 17 AXONOMETRY AND SECTIONS OF T24 STRUCTURE SYSTEM SPIN SYSTEM DETAIL ROTAZIONE DI 360 N AVAILABLE HANGERS atena twister

7 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 7 of 17 AXONOMETRY AND SECTIONS OF INCLINED PROFILE SYSTEM TILT-SPIN SYSTEM DETAIL VERTICAL INCLINATION N ROTATION OF 360 WING FOR HANGING THE PROFILE SUITABLE FOR T24 PROFILES

8 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 8 of 17 ANTISEISMIC SAFETY All Atena false ceilings can be reinforced with Atena ANTISEISMIC KIT, conceived to assure stability to the false ceiling in all high seismic risk areas. Atena S.p.A offers a specialized customer service in antiseismic matters to provide information and solutions for the application of the antiseismic systems. 1. TS Carrier 2. Holed bar 2 1 For seismic areas Baffle false ceilings can be equipped with Atena Atiseismic kit. The application of antiseismic systems must comply with project requirements and it has to be verified with Atena technical department. 1. Crossing joint 2. Holed bar 3. T24 structure 3 2 1

9 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 9 of 17 LIGHTING BAFFLE To create a lighting false ceiling without any interruption between luminous element and baffle body, Atena S.p.A. has developed the Lighting Baffle ; this special element is properly shaped to lodge LED bars, with opal or microprismatic screen, for an effect of diffuse or punctual light. The Lighting Baffle are available with base of 50 mm only. 50mm 1 1. Baffle 2. Street/P2 by Atenalux 2

10 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 10 of 17 ACOUSTIC PERFORMANCE Baffles are widely used to improve the acoustic comfort. They can be used alone or in addition to the existent false ceiling. As well as for the acoustic function Baffles help to preserve the natural lighting and the air flow coming from windows and roof. From the acoustic point of view, Baffles can be used as absorbers or deflectors of the sound wave. According to project requirements, vertical elements may be totally plain to promote sound reflection or perforated and filled with acoustic pad to absorb noises. The perforation is on the long sides only, while the lower one and the two short sides are plain. To choose the right vertical elements to apply, the acoustic material, the number of Baffles and their disposition, it is necessary to carry out a preliminary analysis of the environment and its functions. To do this, Atena S.p.A. cooperates with specialized companies to provide a specific service for acoustic treatment. AVAILABLE PERFORATIONS AP 1/5% P Ø1 AP 1,5/11% P Ø 1,5 4 4 AP 1/10% D Ø1 4 Ø 1, ,66 5 5,66 AP 1,5/22% D Ø 1, ,8 AP 1,8/9,5%P 2 2,8 5 Ø2 7,07 5 AP 1,8/19% D Ø 1,8 2,5 3,54 At ena s.p.a. atena-it.com AP 1,8/9,5% P, AP 1,5/22% D, AP 2/25% D 0,6-0,7 mm. thick. 5 7,07 AP 2/25%D Ø2 5 AP 1/5% P e AP 1/10% D steel - aluminum 0,6 mm. thick. AP 1,5/11% P, AP 2/12,5% P, AP 1,8/19% D, steel - aluminum AP 2/12,5%P 2,5 5 3,54

11 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 11 of 17 TS CARRIER SYSTEM INSTALLATION STEPS Baffles can be installed in few quick steps. 1/ Draw the lines of the perimeter frame. 2 Determine the height of the ceiling with a level and mark it with a string Install the hangers and hook the carriers according to the project requirements interaxe. LOCKING WING 4 Hook the Baffle on the carriers reed. 5 Bend down the carrier locking wings to ensure the system Install the joints to ensure the right alignement of the carriers. 7 Install the Baffle joints to guarantee the continuity of the elements. 6 If required, install the caps to close the Baffle heads. CLOSING CAP, CARRIER JOINT AND BAFFLE JOINT DETAILS TIGHTEN CLIPS: verify with Atena technical department the needs of tighten clips between joints and Baffle or to be positioned according to project requirements. TIGHTEN CLIPS CARRIER JOINT CLOSING CAP BAFFLE JOINT

12 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 12 of 17 T24 STRUCTURE INSTALLATION STEPS Baffles can be installed in few quick steps. 1 Draw the lines of the perimeter frame. 1/2 2 Determine the height of the ceiling with a level and mark it with a string. 3 Proceed with the installation of structure. Install the wall angles with nails, screws and/or plugs suitable to the wall material. 4 Fix the hangers according to the type of ceiling to be installed. 5 Install the main runners with an interaxe of 1200* mm. 6 Proceed with the installation of 1200 mm cross T profiles in to the mail carrier. 7 Install 600 mm Cross T in to 1200 mm Cross T profiles. * Verify the interaxe according to the load at m 2 and particular conditions. 4 MAX ~ ~ BAFFLE CLOSING CAP AND JOINT DETAIL CLOSING CAP BAFFLE JOINT

13 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 13 of 17 Tilt-spin hooks and Baffle installing steps. 1 Complete the installation of the structure. 1 2 Install the tilt-spin system hooks according to the projet requirements and orientate their position. 3 Proceed with the Baffle installation hooking them on the tilt-spin hooks. 2 3 BENDING DOWN

14 Atena S.p.A. Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 14 of 17 SYSTEM ELEMENTS ID CODE DESCRIPTION MATERIAL mm DBA3100L6BIC x 100 h DBA3150L6BIC000 BAFFLE BASE 30 ALL / ACC 30 x 150 h DBA3200L6BIC x 200 h DBA4100L7BIC x 100 h 1 DBA4140L7BIC000 BAFFLE BASE 40 ALL / ACC 40 x 140 h DBA4180L7BIC x 180 h DBA5100L7BIC x 100 h DBA5200L7BIC000 BAFFLE BASE 50 ALL / ACC 50 x 200 h DBA5300L7BIC x 300 h ADGIDBA31OOC06BRT BAFFLE BASE 30 JOINT ALL / ACC 30 x h 2 ADGIDBA414OC06BRT BAFFLE BASE 40 JOINT ALL / ACC 40 x h ADGIDBA51OOC06BRT BAFFLE BASE 50 JOINT ALL / ACC 50 x h BAFFLE BASE 30 CLOSING CAP 30 x h 3 VTAPPOBAFFLE BAFFLE BASE 40 CLOSING CAP ACZ POST 6/10 40 x h BAFFLE BASE 50 CLOSING CAP 50 x h 4 TTS000CO8BRT TS CARRIER ACC 8/10 L x 30 h 5 ADGITTCC08ZIN TS CARRIER JOINT ACC 8/ x 26 h 6 - BAFFLE BASE 50 FOR LED APPLICATION AOMODOPPD4 Ø4 mm DOUBLE SPRING AC AR - 7 AOPEOCCHO250D4 Ø4 mm HANGER WITH EYE ACZ - AOPEGANCO250D4 Ø4 mm HANGER WITH HOOK ACZ mm T24 MAIN PROFILE** ACZ 24 x 38 h 8 - T mm CROSS PROFILE** ACZ 24 x 38 h - T mm CROSS PROFILE** ACZ 24 x 38 h 9 AOSOTWIST10 TWISTER AC TM 10/10 30,5 x 30 x 19,5 cm 10 - SPIN SYSTEM HOOK ACZ TILT-SPIN SYSTEM HOOK ACZ - * The grey part of the code changes according to the chosen product s features. ** To choose T24 model see Atena Steel Strong catalogue. AC = s t e e l - ACZ = g a l v a n i s e d s t e e l - AC TM = s p r i n g s t e e l AC AR = s p r i n g s t e e l ALL = a l u m i n u m - = a s c h o o s e n p r o f i l e

15 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 15 of 17 BAFFLE WEIGHTS AND PACKAGING range model materials Kg/Lm code* 5/10 all 0,326 DBA3100L5GRS000 6/10 all 0,391 DBA3100L6GRS000 7/10 all 0,456 DBA3100L7GRS000 BAFFLE 30x100 30x200 30x200 40x100 40x140 40x180 50x100 50x200 50X300 8/10 all 0,522 DBA3100L8GRS000 5/10 acc 0,930 DBA3100C5GRS000 6/10 acc 1,116 DBA3100C6GRS000 7/10 acc 1,302 DBA3100C7GRS000 8/10 acc 1,488 DBA3100C8GRS000 6/10 all 0,721 DBA3150L6GRS000 7/10 all 0,841 DBA3150L7GRS000 6/10 acc 2,058 DBA3150C6GRS000 7/10 acc 2,401 DBA3150C7GRS000 6/10 all 0,721 DBA3200L6GRS000 7/10 all 0,841 DBA3200L7GRS000 6/10 acc 2,058 DBA3200C6GRS000 7/10 acc 2,401 DBA3200C7GRS000 5/10 all 0,342 DBA4100L5GRS000 6/10 all 0,411 DBA4100L6GRS000 7/10 all 0,479 DBA4100L7GRS000 8/10 all 0,548 DBA4100L8GRS000 5/10 acc 0,977 DBA4100C5GRS000 6/10 acc 1,173 DBA4100C6GRS000 7/10 acc 1,368 DBA4100C7GRS000 8/10 acc 1,564 DBA4100C8GRS000 6/10 all 0,540 DBA4140L6GRS000 7/10 all 0,629 DBA4140L7GRS000 6/10 acc 1,540 DBA4140C6GRS000 7/10 acc 1,797 DBA4140C7GRS000 5/10 all 0,561 DBA4180L5GRS000 6/10 all 0,673 DBA4180L6GRS000 7/10 all 0,785 DBA4180L7GRS000 5/10 acc 1,602 DBA4180C5GRS000 6/10 acc 1,922 DBA4180C6GRS000 7/10 acc 2,242 DBA4180C7GRS000 5/10 all 0,353 DBA5100L5GRS000 6/10 all 0,424 DBA5100L6GRS000 7/10 all 0,495 DBA5100L7GRS000 8/10 all 0,566 DBA5100L8GRS000 5/10 acc 1,009 DBA5100C5GRS000 6/10 acc 1,211 DBA5100C6GRS000 7/10 acc 1,412 DBA5100C7GRS000 8/10 acc 1,614 DBA5100C8GRS000 5/10 all 0,628 DBA5200L5GRS000 6/10 all 0,754 DBA5200L6GRS000 7/10 all 0,880 DBA5200L7GRS000 5/10 acc 1,794 DBA5200C5GRS000 6/10 acc 2,153 DBA5200C6GRS000 7/10 acc 2,511 DBA5200C7GRS000 6/10 all 1,084 DBA5300L6GRS000 7/10 all 1,265 DBA5300L7GRS000 6/10 acc 3,095 DBA5300C6GRS000 7/10 acc 3,610 DBA5300C7GRS000 * The grey part of the code changes according to the baffle features baffle packaging: baffle are supplied in bundles.quantity per bundle according to the project.

16 Atena S.p.A. Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 16 of 17 CLEANING, MAINTENANCE AND REMOVAL Cleaning and maintenance require some attention and care even though are easy to make and don t take much time. It is necessary to use neutral and not aggressive soaps. In case of any damage, staves can be repainted or replaced. False ceilings maintenance usually refers to: placing, alignment or replacement of damaged or broken staves. Baffles can be also removed for restoration or maintenence of the system below. The maintenance work shall be appointed to specialised workers trained with technical data sheets about setting, removal and maintenance of the false ceilings, in order to ensure excellent results. Using inadequate tools can damage the structure, causing adherence loss or even accidental Baffle fall. All the maintenance intervention must follow the technical data sheet indication and every noted diversity has to be promptly reported. Each worker assigned with maintenance operation must carefully remove the Baffle, perform the intervention and do not alter the false ceiling structure, the hanging system and the connection between these elements. When the maintenance is over, install again the Baffle, verifying that the staves are properly hooked to the carriers and the planarity is guaranteed. Any difference in staves level is caused by wrong installation and, for this reason, they must be quickly controlled. TS CARRIER SYSTEM DISMOUNTLING DETAIL Lift-up locking wing Unhook the stave extending it outwards T24 STRUCTURE SYSTEM DISMOUNTLING DETAIL Remove the stave from the hooks Lift up the locking wing of the tilt-spin system hook

17 Data sheet ATENA BAFFLE - rev 2 of 08/03/ pag. 17 of 17 STORAGE MODE Materials supplied by Atena S.p.A. shall be maintained in good condition from purchase to installation. Materials must be stored in a closed, clean and dry site. Atena S.p.A. protects its products with resistant packaging under normal handling. Please handle packages with care to avoid shocks and inappropriate handling that might damage what is provided. Baffles are delivered on pallets secured with stripes and cellophane. The manual handling must be carried out with caution and in compliance with safety regulations at work. For carriage of packaged products on pallets, provide a mechanical transport to avoid damages or risks resulting from inadequate transport. RIFERIMENTI NORMATIVI E GARANZIE Each Atena false ceiling is produced for internal use according to the technical rules for construction EUROCODICE and the specific regulations UNI EN 13964, 14195:2005. Each Atena S.p.A. product has its own DOP (Declaration Of Performance) CE according to the European Law 305/2011. False ceilings and claddings for internal and external use have to be dimensioned on environment features, to list some of the possible examples: earthquakes, wind, thermal expansion, place of installation, use destination of the building and project requests. Indipendently by information, suggestions, advices and technical opinions exchanged between the parts, Atena S.p.A. will produce its products only according to the orders received and the technical drawings/ projects attached, having no responsibility on what is not indicated in the order, in the technical drawings or in the project. Atena S.p.A., as producer, is responsible for manufacturing defects. Complaints have to be presented according to the selling conditions. Materials used for Atena false ceilings have been produced just with this purpose, every other use is considered improper.