1750 PLEASANT RIDGE DRIVE LEXINGTON, KY 40509

Size: px
Start display at page:

Download "1750 PLEASANT RIDGE DRIVE LEXINGTON, KY 40509"

Transcription

1 1750 PLEASANT RIDGE DRIVE LEXINGTON, KY Kentucky811 C0.0 Lexington Fayette County C1.0 C2.0 C3.0 C4.0 C5.0 C6.0 - C6.3 C7.0 VICINITY MAP COVER SHEET MAN O' WAR DEVELOPMENT, UNIT 2A 2024 BRYANT RD. & C0.0

2

3 INSTALL ADS FLEX STORM PC+ 62LHDPCP BRYANT ROAD INSTALL ADS FLEX STORM PC+ 62LHDCBEXTPCP LEGEND CONSTRUCTION PLAN C2.0

4 LEGEND BRYANT ROAD PAVEMENT PLAN C1.0

5 WATERLINE NOTES: GENERAL UTILITY NOTES W1 W2 W3 W4 W5 W6 W7 CONSTRUCT xx"x8" TAPPING SLEEVE AND VALVE. WORK SHALL BE PERFORMED BY KENTUCKY AMERICAN WATER AT OWNER'S EXPENSE. CONSTRUCT APPROX. 65 L.F. OF 8" WATER MAIN UNDER PLEASANT RIDGE DRIVE. WORK SHALL BE PERFORMED BY KENTUCKY AMERICAN WATER AT OWENR'S EXPENSE. CONSTRUCT 4" DOMESTIC WATER SERVICE LINE. WORK SHALL BE PERFORMED BY KENTUCKY AMERICAN WATER AT OWNER'S EXPENSE. CONSTRUCT 2-2" WATER METER FOR DOMESTIC WATER SERVICE. WORK SHALL BE PERFORMED BY KENTUCKY AMERICAN WATER AT OWNER'S EXPENSE. CONSTRUCT POST INDICATOR VALVE FOR FIRE DEPARTMENT CONNECTION PER DIVISION OF FIRE, WATER CONTROL OFFICE REQUIREMENTS. WORK SHALL BE PERFORMED BY KENTUCKY AMERICAN WATER AT OWNER'S EXPENSE. CONSTRUCT APPROX. 226 L.F. OF 3" DOMESTIC WATER SERVICE LINE FROM METER TO BUILDING. WORK SHALL BE PERFORMED BY SITE CONTRACTOR. CONSTRUCT APPROX. 215 L.F. OF 6" FIRE PROTECTION WATER LINE FROM PIV TO BUILDING. WORK SHALL BE PERFORMED BY SITE CONTRACTOR. PT3 W8 W9 W10 W11 CONSTRUCT BACK FLOW PREVENTER ( DCDA WITH A "THEFT METER" ) AND VAULT AS PER KENTUCKY AMERICAN WATER REQUIREMENTS. WORK SHALL BE PERFORMED BY SITE CONTRACTOR. CONSTRUCT PRIVATE FIRE HYDRANT ASSEMBLY. WORK SHALL BE PERFORMED BY SITE CONTRACTOR. CONSTRUCT PRIVATE POST INDICATOR VALVE FOR FIRE DEPARTMENT CONNECTION PER DIVISION OF FIRE, WATER CONTROL OFFICE REQUIREMENTS. WORK SHALL BE PERFORMED BY SITE CONTRACTOR. CONSTRUCT APPROX. 35 L.F. OF 6" FIRE PROTECTION WATER LINE TO FIRE DEPARTMENT CONNECTION. WORK SHALL BE PERFORMED BY SITE CONTRACTOR. PT2 E1 E3 S2 S1 W5 W3 W2 W1 W12 CONSTRUCT FIRE DEPARTMENT CONNECTION PER DIVISION OF FIRE, WATER CONTROL OFFICE REQUIREMENTS. WORK SHALL BE PERFORMED BY SITE CONTRACTOR. E2 W4 NATURAL GAS NOTES: G1 PROPOSED GAS SERVICE CONNECTION. CONTACT COLUMBIA GAS FOR CONSTRUCTION OF GAS MAIN CONNECTION. W8 W7 W6 G1 G2 PROPOSED 2" GAS SERVICE LINES. W11 W12 G2 G3 PROPOSED GAS METER. G3 W7 SANITARY SEWER NOTES: S1 REMOVE EXISTING 6" SANITARY SEWER SERVICE LATERAL, (APPROXIMATE LOCATION). CONTRACTOR SHALL TIE-IN NEW 8" SEWER FROM BUILDING TO EXISTING MANHOLE. EXISTING MANHOLE INV. ELEV (APPROX.) G2 W6 W9 W10 S2 CONSTRUCT 8" SEWER SERVICE LINE E2 E2 ELECTRIC NOTES: E1 E2 E3 CONSTRUCT CONCRETE TRANSFORMER PAD. PAD TO BE A MINIMUM OF 15' FROM THE BUILDING. PAD TO BE CONSTRUCTED BY SITE CONTRACTOR CONSTRUCT PRIMARY ELECTRIC LINE. LINE TO BE INSTALLED BY KU. CONDUIT TO BE INSTALLED BY SITE CONTRACTOR. (SEE NOTE BELOW) CONSTRUCT SECONDARY ELECTRIC LINE WORK SHALL BE PERFORMED BY SITE CONTRACTOR PT1 KU TO INSTALL 360' OF 3#1/OAL UNDERGROUND 12KV PRIMARY FROM PT 1 TO PT 2, 310' OF 3#1/OAL UNDERGROUND 12KV PRIMARY FROM PT 1 TO PT 3, AND KVA 12KV VOLT PMT AT PT 2. SITE CONTRACTOR IS TO PROVIDE AND INSTALL 2-4" DIA. SCH 40 PVC CONDUITS FROM PT 1 TO PT 2, 1-4" DIA. SCH 40 PVC CONDUIT FROM PT 1 TO PT 3, A MIN OF 42" DEEP AND BACKFILL LBS. NYLON PULL STRING IN EACH CONDUIT, WITH 3' RADIUS SCH 40 ELBOWS AT PMT AND FEED THRU BOXES, PROVIDE AND INSTALL SERVICE CONDUITS AND CONDUCTOR FROM PMT TO BUILDING A MIN. OF 30" DEEP, PROVIDE AND INSTALL CONCRETE PAD AND METER PEDESTAL TO KU SPECS. INSTALL BOLLARDS BETWEEN PARKING SPACE AND PMT TO KU SPECS. KU PRIMARY LINE TO BE A MIN. OF 6' HORIZONTALLY FROM SEWER LINES. PMT IS TO BE A MIN. OF 15' FROM THE BUILDING OR OWNER WILL BE REQUIRED TO INSTALL A FIRE WALL TO KU SPECS. UTILITY CONTACT INFORMATION TELEPHONE GAS CABLE TV WATER ELECTRIC SANITARY SEWER SITE UTILITY PLAN C4.0

6 E.P.S.C. NOTES: LEGEND EROSION PREVENTION & SEDIMENT CONTROL PLAN C5.0

7 GUARD POST DETAIL DUMPSTER PAD/ENCLOSURE DETAIL MAN O' WAR DEVELOPMENT, UNIT 2A DETAILS C6.0

8 DETAILS C6.1

9

10

11 JUSTICE DRIVE BRYANT ROAD TREE LEGEND SITE STATISTICS LANDSCAPE PLAN C7.0