URBAN REGENERATION OF A COMMUNITY IN MADRID MULTI-COMFORT HOUSE STUDENT CONTEST EDITION 2017 MARIANN KRUUSE ALLAR ESKO

Size: px
Start display at page:

Download "URBAN REGENERATION OF A COMMUNITY IN MADRID MULTI-COMFORT HOUSE STUDENT CONTEST EDITION 2017 MARIANN KRUUSE ALLAR ESKO"

Transcription

1 URBAN REGENERATION OF A COMMUNITY IN MADRID MULTI-COMFORT HOUSE STUDENT CONTEST EDITION 2017 MARIANN KRUUSE ALLAR ESKO I ESTONIA

2 SITUATION PLAN

3 PUBLIC PARK NEW COMMERCIAL AREAS PRIVATE INNER COURTYARD

4

5

6 EXISTING BUILDINGS

7 STEEL SKIN

8 NEW BALCONIES AND WALKWAYS

9 ADJUSTABLE AND FIXED SHADING

10 ADDITIONAL APARTMENTS

11 FINAL DESIGN

12

13 FINAL DESIGN WOODEN BEAMS WITH GREENERY NEW STORAGE UNITS GREENERY EXISTING GROUND

14

15 FIRST FLOOR NEW EXTERNAL STAIRCASES ELEVATORS

16 SECOND FLOOR

17 STANDARD APARTMENT PLAN 70m2 + TERRACE 19m2 NEW SUPPORTING GLUELAM BEAM ADDED TERRACE

18 THIRD FLOOR

19 FOURTH FLOOR

20 ADDITIONAL APARTMENT PLAN 83m2 + TERRACE 29m2

21

22 SECTION I-I AND DETAILS A B D A C E F A Outside wall Weber.pas 471 decorative plaster Weber.Therm basecoat with Weber 397 fiberglass mesh 10 mm Isover FS 30 insulation 200 mm (ʎD = 0,037 W/mK) existing brick construction 290 mm weber.vetonit AH plaster 2 mm Lden = 23 Db U = 0,141 W/m2K B - Roof Rolled metal roof wooden frame 32x100 wooden frame 50x32 Isover Tyvek underlay wooden frame 32x50 wooden rafters 50x200 Isover InsulSafe blowing wool 400 mm (ʎD = 0,040 W/mK) existing concrete slab 160 mm U = 0,101 W/m2K C Slab floor finish 15 mm flooring underlay concrete slab 80 mm Isover Vario xtra vapour barrier Isover FLO insulation 2x40 mm (ʎD = 0,035 W/mK) existing concrete slab 160 mm Isover FS 5+ insulation 100 mm (ʎD = 0,031W/mK) Weber Therm 310 plaster 5 mm U = 0,173 W/m2K D Wall against ground Weber topcoat render 10 mm XPS Styrofoam 250 SL-A-N 150 mm (ʎD = 0,036 W/mK) Isover Vario xtra vapour barrier existing concrete slab 160 mm Weber Therm 310 plaster 5 mm E Interior wall Gyproc GN13 gypsum board 2x13 mm Isover KL-AKU insulation 95 mm / metal frame (ʎD = 0,040 W/mK) Gyproc GN13 gypsum board 2x13 mm D'nT,w = 46 db F Wall against neighbour Gyproc GN13 gypsum board 3x13 mm Isover KL-AKU insulation 66 mm / metal frame (ʎD = 0,040 W/mK) air gap 20mm Metal frame Isover KL-AKU insulation 66 mm / metal frame Gyproc GN13 gypsum board 3x13 mm

23 SECTION II-II AND DETAILS J H I A G G Slab between floors floor finish 15 mm flooring underlay concrete slab 80 mm Isover Vario xtra vapour barrierisover FLO insulation 2x40 mm (ʎD = 0,035 W/mK) existing concrete slab 160 mm L'nT,w = 40 db H Additional apartment wall Weber.pas 471 decorative plaster Weber.Therm basecoat with Weber 397 fiberglass mesh 10 mm Isover FS 30 insulation 50 mm (ʎD = 0,037 W/mK) Gyproc glasroc storm GHS9 9mm Isover KL 32 insulation / wooden frame 150 mm (ʎD = 0,032 W/mK) Isover Vario xtra vapour barrier Isover KL 32 insulation / wooden frame 50 mm Gyproc GN13 gypsum board 13 mm U = 0,147 W/m2K I Additional apartment slab floor finish 15 mm flooring underlay OSB board 25 mm Isover Vario xtra vapour barrier Isover KL 32 insulation / gluelam timber frame 200 mm (ʎD = 0,032 W/mK) Gyproc glasroc storm GHS9 9mm Isover FS 30 insulation 50 mm (ʎD = 0,037 W/mK) Weber Therm basecoat with Weber 397 fiberglass mesh 10 mm Weber.pas 471 decorative plaster U = 0,147 W/m2K J Additional apartment roof PVC roofing membraane OSB board 22 mm Isover Tyvek underlay wooden frame / ventilated air gap 80 mm Isover RKL 31 Facade EJ wind barrier 50 mm (ʎD = 0,031 W/mK) Isover KL 32 insulation 150 mm / wooden frame (ʎD = 0,032 W/mK) Isover Vario xtra vapour barrier Isover KL 32 insulation 50 mm / wooden frame (ʎD = 0,032 W/mK) Gyproc GN13 gypsum board 13 mm All materials are EPD approved

24 SHADING SYSTEM AND SUN ANALYSIS SUMMER SUN WINTER SUN DECEMBER BALCONIES PROTECT THE APARTMENTS FROM THE DIRECT SUNLIGHT THAT COMES FROM THE HIGH SUMMER SUN ADJUSTABLE SHADING PROTECTS THE APARTMENTS FROM THE LOWER WINTER SUN AND IT CAN ALSO BE USED TO BLOCK DIRECT SUNLIGHT FROM THE MORNING AND EVENING SUN JULY

25 NORTH ELEVATION

26 EAST ELEVATION

27 ENERGY PLAN Ventilation system with heat recovery

28 USAGE Building type: Residential Usage: For living Design temperatuure: 20 AREA INPUT Heated space area: m2 Heated space volume: m3 QUALITY Thermal bridge: Free Airtightness rate: 0.60 AVERAGE U-VALUES Pitched roof: 0.10 W/(m2K) Wall against air: 0.14 W/(m2K) Wall against ground: 0.17 W/(m2K) Slab against unheated cellar: 0.17 W/(m2K) Windows: 0.73 W/(m2K) Doors: 0.80 W/(m2K) HVAC Heat recovery system: 95.00% OVERHEATING Exterior Thermal Transmittance: W/K Ground Thermal Transmittance: W/K Ventilation Transmittion Ambient: W/K Ventilation Transmission Ground: 0.00 W/K Solar Aperture: m2 Frequency of Overheating: 4.91 %

29 THANK YOU!