Waiver# 187-R0. Requirements to be Waived.

Size: px
Start display at page:

Download "Waiver# 187-R0. Requirements to be Waived."

Transcription

1 Waiver# 187-R0 Requirements to be Waived. City of Gainesville Chief Building Officer has cited Florida Building Code 5th Edition (2014) Accessibility, Chapter 2, section Vertical accessibility, stating that the art studio spaces on the second floor of this project do not meet any of the vertical accessibility exceptions provided. Further, Multi- Story Buildings and Facilities states that, "At least one accessible route shall connect each story and mezzanine in multi-story buildings and facilities." In this section, all exemptions have been deleted. Advisory Multi-Story Buildings and Facilities Exceptions, refers back to the exceptions 1 7 in section , and states that, "Florida requirements may be waived down to the ADA Standards requirements." ADA Title III Regulation 28 CFR Part 36, Sec New construction, (d) Elevator exemption, contains an exception to the general rule requiring elevators. Elevators are not required in facilities under three stories or with fewer than 3000 square feet per floor, unless the building is a shopping center or mall; professional office of a health care provider; public transit station; or airport passenger terminal. If the elevator exemption if granted, it is a "vertical access" exemption. This means that no accessible element need be provided to a second or third floor. This does not mean that if an entity wishes to provide access by ramp or a lift, it is, of course, free to do so. We request exemption from the requirement for vertical accessibility through this waiver process as described in Advisory Multi-Story Buildings and Facilities Exception 1. However, we recognize the importance of the shared experience of architecture, design and art. Therefore, we propose the inclusion of an unenclosed platform lift, fitted with unassisted entry, operation, and exit, in the phase 1 portion of this project. Since non-disabled access to the upper space will be gained using an uncovered exterior stair, this platform lift will provide equivalent access to people with disabilities, guest or tenant. Phase 2 of our project is smaller and is likely to be occupied by a single tenant, the owner.

2 40'-0" 7'-6" 47'-6" B C A SWITCH SWITCH (3 WAY) GFI 42" 24" O.C. U.N.O. 16'-0" F E D C B A 7'-6" 20'-0" 12'-6" 2'-9" 2'-6" 16'-0" 2'-9" 2'-9" attic (unfinished) 8'-0" 8'-0" attic (unfinished) 47'-6" 40'-0" 7'-6" 8'-0" 8'-0" unit sf studio (A/C) closet covered exterior 67 sf covered exterior 593 sf (642 sf paved) studio (no A/C) unit sf women's (no A/C) men's (no A/C) unit sf covered exterior 570 sf (249 sf paved) unit sf studio (A/C) 2'-6" 2'-9" lounge (A/C) unisex (A/C) 4'-1" 3'-0" 1' " 6'-0" 6' " 6'-0" 13'-51 2 " 8'-0" 4'-2" 2'-8" 3'-10" 2'-8" 6'-8" 6'-0" 14'-0" 3'-9" 13'-6" 43'-9" deck 225 sf 0'-6" 4'-4" 2'-6" 3'-10" 2'-6" 8'-0" 23'-6" 8'-0" 5'-0" 2'-0" 8'-0" 2'-0" 8'-0" 30'-0" 49'-1" 12'-6" 20'-0" 7'-6" 8'-0" 9'-1" 3'-9" 13' " 6'-0" 6'-31 2 " 6'-0" 8'-31 2 " 7'-5" 16'-0" 51'-2" 8'-0" 8'-0" 16'-0" ROOF PLANS - PHASE /16" = 1'-0" 1/16" = 1'-0" N N ROOF PLANS - PHASE 2 1 BUILDING PLANS - PHASE 1 1/8" = 1'-0" N 2 BUILDING PLANS - PHASE 2 1/8" = 1'-0" N KEY PLAN NTS STEPHEN BENDER AR Rev: Rev: Description: Date: 00/00/00 Rev: Description: Date: 00/00/00 Date: 00/00/00 Project Title: Client Name: Consultants: -- design by bndr llc stephen bender, AIA, LEED AP BD+C, FL#AR NW 43rd ST, STE-B, GAINESVILLE, FL FL COA# AA v f stephen@bndrd.com Drawn: Sheet Size: Sheet Description: Date: SDB Approved: Date: sdb D Scale: : 1 as noted Sheet Number: (C) bndr llc 2016 LIGHTING SYMBOLS LEGEND 1X4 FLORESCENT LIGHT 2X4 FLORESCENT LIGHT 1X4 FLORESCENT LIGHT ELECTRICAL SYMBOLS LEGEND 120 VOLT OUTLET (NUMBER INDICATES HEIGHT ABOVE FINISHED 120 VOLT OUTLET (GROUND FAULT INTERRUPTED) TELEPHONE JACK AND COMPUTER CONNECTION ELECTRICAL PANEL - GE POWERMARK PLUS TL30420C WALL TYPE LEGEND NOT USED - 2 HR DEMISING WALL; 4" WOOD NOT USED - 4" WOOD STUD PARTITION WALL W/ STUDS 16" O.C. W/(2) LAYER 5/8 AR GYP.BD. EACH SIDE - U301 NOT USED - EXISTING DEMISING WALL CMU CONSTRUCTION - SEE STRUCTURAL DRAWINGS MASONRY VENEER bndr llc FL LIC# AA N Note Regarding Revised Sheets Upon acceptance into contract documents this drawing supercedes all previous drawings to which it refers. Elestial Sound Container Art Studios 1705 NE 16th Avenue GAINESVILLE, FL MTDH LLC Tubbs, Michael 1115 N.E. 6th Street GAINESVILLE, FL Development Permit Application PLANS PLN

3

4

5

6

7

8

9

10

11

12