Covering Design Regions

Size: px
Start display at page:

Download "Covering Design Regions"

Transcription

1 Covering

2 Covering Design Regions

3 Roof Covering

4 Roof Covering (SSR) 24 coverage w/ 3 seam height Machine seamed, in-place Attached to roof secondary (purlins, widebay truss purlin or bar joist) w/ a concealed sliding clip which allows 1 5/8 thermal movement each direction, 3 1/4 total

5 SSR PANEL CLIPS Fixed Sliding

6 Center Seaming Tab in Slot (2) Fasteners Per Clip At Endlaps and Ridge End. Clip Must Be Installed Under Panel Stiffener

7 Note: Taller SSR clips are used with thermal block/super block. Adjustments may be desired in eave height input which is measured from top of purlins.

8 SSR Profile

9 Roof Covering (SSR) Weather-tight roof system 24 gage w/ 22 gage available upon special request 25 year Finish Warranty Galvalume KXL (Kynar 500 or Hylar 5000 ) Variety of colors to choose from Use with Blanket Insulation up to 6 thick (over purlins) or Rigid Board up to 3 1/2 thick ¼ : 12 minimum roof pitch

10 Roof Covering (SSR)

11 SSR Staggered Lap Panel lap is 9 above the Purlin Staggered Lap is typically 5-0 (purlin spacing) Sheet either direction, except with Tuflites Notch is factory applied

12 SSR Staggered Lap

13

14

15 SSR Ridge

16 SSR Ridge Detail

17 SSR Ridge Detail

18

19

20

21 SSR and HWR Profile

22 SSR High Wind Roof The HWR roof system is primarily intended for the higher coastal wind regions, Caribbean, etc.. It is not intended to replace the SSR roof system with 90 to 110 mph +/- winds. The SSR system, with lower wind speeds, would be cheaper than the HWR. The HWR with higher winds will price out in most all cases. For wind speeds greater than 110 mph, and up to 200 mph, the HWR roof system will design w/o unpriced items. (assumes that one would select deeper depth purlins as required) Purlin spaces for the 110 to 200 mph case above ranged from 4 6 to 5 0 in the roof field and rakes, eaves lower.

23 SSR HWR

24 HWR Clips

25 HWR Factory Mutual (FM) ratings with 5-0 purlin spacing and 24 gage panel Florida, Miami-Dade approved UL approved expansion and contraction is the same as standard SSR as limited by the bull-nose style ridge trim Same eave and rake trims as SSR

26 HWR 8 is the standard clip length used at all purlins 12 clip used at corner and edge zone conditions where 8 clips not sufficient Used with ZEE purlins in depths of 8 ½, 10, and 11 ½ Purlin Channel bracing required May not be used with 7 deep purlins(due to purlin channel bracing being required) Superblock not available at this time

27 SSR High Wind Roof No rake subpurlins needed. (possibly with FM rated assemblies requiring reduced spaces) VPCommand will automatically populate the rake and corner zones with 12 clips as required for design. Great FM ratings with 5 purlin spaces and 24 ga. panels Florida, Miami-Dade approved. UL approved. Expansion/contraction same as SSR as limited be the bull-nose style ridge trim. Same eave and rake trims as SSR.

28 SSR

29 SSR

30 SSR Fixed Eave

31 SSR Fixed Centerline (Floating Eave)

32 SSR Fixed Eave

33 SSR Fixed CL / Floating Eave

34 SSR 6 Roof Step Expansion

35 Expansion & Contraction

36 Expansion & Contraction

37 Floating Roof System

38 SSR Insulation over purlins

39 SSR Thermal Block

40 SSR Module Strip

41 SSR SuperBlock

42

43 Thermal Performance - PR

44 Thermal Performance - SSR

45 Thermal Performance-SSR (Thermal Block)

46 Thermal Performance-SSR (Superblock)

47 Seamer Tool

48 Seamer Tool

49 Contact your VP Service Center for assistance. SSR Seam Clamp

50 Roof Covering Standing Seam (SSR) Panel Rib (PR)

51 Panel Rib

52 Roof Covering (PR) 36 coverage Available in 26, 24, & 22 gages Available in Galvalume & KXL finishes

53

54

55 Roof Covering (PR) Attached to purlins with selfdrilling fasteners Use with Blanket Insulation up to 4 thick 1 / 2 :12 minimum roof pitch Cannot be used on TP/bar joist

56 Panel Rib

57

58 Roof Covering Standing Seam (SSR) Panel Rib (PR) SLR II

59 Roof Covering (SLR II) 2 SLR II Architectural Standing Seam Roof System (2 Seam Height) Available in a variety of KXL colors

60 Roof Covering (SLR II) 16 Coverage with 2 Seam Heights Machine seamed in-place Attached to roof secondary (purlins or bar joist) w/ a concealed clip which allows 1 thermal movement. Weather tight Roof System

61

62

63 SLR II

64

65 Roof Covering (SLR II) 24 Gage only with 2 High Rib 25 - Year Warranted KXL Finishes Variety of colors to choose from Use with Blanket Insulation up to 6 thick Thermal Blocks are Required

66 SLR II Ridge Detail

67 SLR II

68 SLR II

69 SLR II

70 SLR II

71 SLR II

72

73 Thermo-Deck System

74 Components

75 TLS Processing Guidelines The roof panel lengths will need adjustment at the splices. Panel lengths will need to be adjusted by the rise of the depth of the TLS System

76

77 VP Roof Factory Mutual SSR and SLR II Roof Systems are approved in various type applications and listed in the FM Approval Guide. 24 Ga SSR is available in Class 1-60, 1-75, Ga SSR is available in Class 1-75, 1-90, Ga SLR is available in Class 1-90,

78

79 Walls: PR, VR, RPR Roofs: PR, SSR

80 PR, VR, SSR

81 SLR II

82 Cool Roofing (reduces heat island effect)

83 Covering Wall Covering

84 Wall Covering Panel Rib (PR) Vee Rib (VR) Reverse Panel Rib (RPR)

85 Wall Covering Panel Rib (PR)

86

87 Panel Rib (PR) 36 Coverage Available up to 41-0 long Variety of end conditions available Available with KXL & Galvalume finishes Fasteners match wall color 26, 24 & 22 available Use with insulation up to 4 thick

88

89 Crimped Base Panel Rib

90 Crimped Base Panel Rib

91 Crimped Base Panel Rib

92 Crimped Base Panel Rib

93 Panel Rib Wall

94 Panel Rib Wall

95 Vee Rib Wall

96 Vee Rib (VR) 36 Coverage Available up to 41-0 long Stucco Embossed Panels available KXL finishes Fasteners match wall color 26, 24, & 22 gage Use with insulation up to 4 thick

97

98 Vee Rib Base

99 Vee Rib

100 Vee Rib

101 Wall Covering Reverse Panel Rib (RPR)

102 Reverse Panel Rib (RPR) 36 Coverage Available up to 41-0 long Available with KXL & Galvalume finishes Fasteners match wall color 26, 24 & 22 available Use with insulation up to 4 thick

103 Reverse Panel Rib (RPR)

104 Reverse Panel Rib (RPR)

105 Wall Covering Panel Rib (PR) Vee Rib (VR) Reverse Panel Rib (RPR)

106 Wall Covering Crating Options: Max. Cnt. per Crate Request a maximum quantity of panels per crate / bundle to Manufacturing. Max. Wt. per Crate Request a maximum weight of panels per crate / bundle to Manufacturing. Max. Dist. Combine Sets The maximum distance between like panel set to be combined.

107 Wall / Roof Material NBVP The builder is must supply the actual weight of these materials.the weights on this page are only for reference. WALLS ROOFS Brick Copper or tin 1 psf 4" 40 psf Corrugated steel See Manufacture 8" 80 psf 3-ply ready roofing 1 psf 12" 120 psf 3-ply felt and gravel 5 1/2 psf 5-ply felt and gravel 6 psf Hollow Concrete Block (Heavy Aggregate) 4" 30 psf Shingles 6" 43 psf Wood 2 psf 8" 55 psf Asphalt 3 psf 12 1/2" 80 psf Clay tile 9-14 psf Slate 1/4" 10 psf Hollow Concrete Block (Light Aggregate) 4" 21 psf Sheathing 6" 30 psf Wood 3/4" 3 psf 8" 38 psf Gypsum 1" 4 psf 12" 55 psf Insulation (per 1" thick) Miscellaneous Loose 1/2 psf Window, glass, frame, & 8 psf Poured-in-place 2 psf sash Rigid 1 1/2 psf

108 Thermal Performance PR, VR

109

110 FP-12 Soffit FP 12 Soffit panel only Flush Panel Design 12 Module 7/8 Panel Height 24 and 22 Gage No Clips Required Available vented (perforated) & Stiffening Beads ( 1 or 2)

111 Girt Strapping for Panel NBVP

112 FP-12 Soffit

113 Texture Clad

114 TextureClad 16 Wide Coverage Lengths 2 to 22 Stackable Panels 20 gage G-90 Galvanized Steel Concealed Fastener Installation Attaches Directly to Wall Girts (max. span of 5-6 )

115 TextureClad

116 Aspen Ice Arena

117 OMETEK

118 TextureClad Close-up of window and door trim

119 TextureClad

120 TextureClad

121 ThermalClad Wall Panels Architectural (36 Width) Planked (42 Width) Reveal (42 Width) Tuff-Wall (42 Width) Roof Panel TCR 42 (42 Width) Thickness: 2, 2.5, 3 & 4

122 ThermalClad Wall Panel Length Gauge Interior Exterior Gauge Varies Stucco Embossed Concealed Fastener Max R Value PVDF Finish Reveal

123 ThermalClad Roof Panel 42 Wide Length Gauge Exterior Stucco Embossed Concealed Fastener Max R Value 32.3 PVDF Finish 2 High SLR Rib TCR - 42 TCR - 42

124 Oil Canning (NOT VP Buildings)

125 Oil Canning (NOT VP Buildings)

126 Oil Canning

127 Oil Canning-Ways to Reduce

128 Oil Canning-Ways to Reduce

129 Oil Canning-Ways to Reduce

130 Oil Canning

131

132