SAP Calculations. Acheson Construction. Project: Plot 8, Neils View Maiden Newton. Contact: James Frampton Trinity Architecture

Size: px
Start display at page:

Download "SAP Calculations. Acheson Construction. Project: Plot 8, Neils View Maiden Newton. Contact: James Frampton Trinity Architecture"

Transcription

1 SAP Calculations Client: Acheson Construction Project: Plot 8, Neils View Maiden Newton Contact: James Frampton Trinity Architecture

2 CODE FOR SUSTAINABLE HOMES - CfSH November 2010 Page 2 of 8 Survey Reference: 001 Prop Type Ref: Property: Plot 8, Neils View, Maiden Newton SAP Rating: 73 C Software Version: Elmhurst Energy Systems SAP2009 Calculator (Design System) version 4.02r03 SAP version: SAP 2009, Regs Region: England and Wales (Part L1A 2010), Calculation Type: New Dwelling As Designed ENE 1 calculation Total floor area m2 DER kgco2/yr/m2 TER kgco2/yr/m2 CO2 emissions offset from additional allowable electricity generation 0.00 kgco2/yr/m2 (ZC7) Residual CO2 emissions offset from biofuel CHP 0.00 kgco2/yr/m2 (ZC5) Total CO2 emissions offset from SAP Section 16 allowances 0.00 kgco2/yr/m2 DER accounting for SAP Section 16 allowances kgco2/yr/m2 % reduction DER/TER 0.96 % CfSH ENE1 credits achieved 0.1 CfSH ENE1 level achieved 3 ENE 2 calculation Dwelling type End-terrace house Fabric energy efficiency (F.E.E.) 44.9 CfSH ENE2 credits achieved 7.2 CfSH ENE1 and 2 overall level achieved 3 ENE 7 calculation Standard case CO2 emissions Total floor area m2 DER kgco2/yr/m2 CO2 emissions from electrical appliances kgco2/yr/m2 (ZC2) CO2 emissions from cooking 2.10 kgco2/yr/m2 (ZC3) Standard case total CO2 emissions kgco2/yr/m2 (ZC4) Net Standard case CO2 emissions kgco2/yr/m2 (ZC8) Actual case CO2 emissions DER kgco2/yr/m2 CO2 emissions from electrical appliances kgco2/yr/m2 (ZC2) CO2 emissions from cooking 2.10 kgco2/yr/m2 (ZC3) Actual case total CO2 emissions kgco2/yr/m2 (ZC4) CO2 emissions from Biomass 0.00 kgco2/yr/m2 (ZC5) CO2 reduction from additional allowable electricity generation 0.00 kgco2/yr/m2 (ZC7) Net Actual case CO2 emissions kgco2/yr/m2 (ZC8) % improvement in net actual/net standard case CO2 emissions 0 % ENE7 credits achieved 0

3 Building Regulation Compliance Page 3 of 8 Survey Reference: 001 Prop Type Ref: Property: Plot 8, Neils View, Maiden Newton SAP Rating: 73 C Software Version: Elmhurst Energy Systems SAP2009 Calculator (Design System) version 4.02r03 SAP version: SAP 2009, Regs Region: England and Wales (Part L1A 2010), Calculation Type: New Dwelling As Designed SUMMARY FOR INPUT DATA FOR New Build (As Designed) 1 TER and DER Fuel for main heating: Electricity Fuel factor: 1.47 (electricity) Target Carbon Dioxide Emission Rate (TER) kg/m 2 Dwelling Carbon Dioxide Emission Rate (DER) kg/m 2 OK 2 Fabric U-values Element Average Highest External wall 0.20 (max. 0.30) 0.20 (max. 0.70) OK Floor 0.12 (max. 0.25) 0.12 (max. 0.70) OK Roof 0.09 (max. 0.20) 0.09 (max. 0.35) OK Openings 1.20 (max. 2.00) 1.20 (max. 3.30) OK 2a Thermal bridging Thermal bridging calculated from linear thermal transmittances for each junction 3 Air permeability Air permeability at 50 pascals: 4.00 (design value) Maximum 10.0 OK 4 Heating efficiency Main heating system: Boiler system with radiators or underfloor - Electric BEE Direct-acting boiler Secondary heating system: None 5 Cylinder insulation Hot water storage Measured cylinder loss: 1.23 kwh/day Permitted by DBSCG 1.89 OK Primary pipework insulated: No primary pipework 6 Controls Space heating controls: Time and temperature zone control OK Hot water controls: Cylinderstat OK 7 Low energy lights Percentage of fixed lights with low-energy fittings: 100% Minimum 75% OK 8 Mechanical ventilation Continuous extract system (decentralised) Specific fan power: Maximum 0.7 OK 9 Summertime temperature Overheating risk (Southern England): Not significant OK Based On: Overshading: Average

4 Windows facing East: Windows facing South East: Windows facing South: Windows facing West: Windows facing North West: Ventilation rate: 6.00 Blinds/curtains: None 10 Key features Roof U-value Floor U-value Door U-value Window U-value Party wall U-value Air permeability Building Regulation Compliance Page 4 of m 2, No overhang 5.16 m 2, No overhang 1.51 m 2, No overhang 3.63 m 2, No overhang 3.65 m 2, No overhang 0.09 W/m 2 K 0.12 W/m 2 K 1.20 W/m 2 K 1.20 W/m 2 K 0.00 W/m 2 K 4.0 m 3 /m 2 h

5 Predicted Energy Assessment Page 5 of 8 Plot 8, Neils View, Maiden Newton Dwelling type: House, End-Terrace Date of assessment: 27.May.2014 Produced by: Trinity Architecture Total floor area: m 2 This document is a Predicted Energy Assessment for properties marketed when they are incomplete. It includes a predicted energy rating which might not represent the final energy rating of the property on completion. Once the property is completed, this rating will be updated and an official Energy Performance Certificate will be created for the property. This will include more detailed information about the energy performance of the completed property. The energy performance has been assessed using the Government approved SAP2009 methodology and is rated in terms of the energy use per square meter of floor area; the energy efficiency is based on fuel costs and the environmental impact is based on carbon dioxide (CO2) emissions. Energy Efficiency Rating Environmental Impact (CO2) Rating Very energy efficient - lower running costs (92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) A B C D E Not energy efficient - higher running costs EU Directive England & Wales 2002/91/EC The energy efficiency rating is a measure of the overall efficiency of a home. The higher the rating the more energy efficient the home is and the lower the fuel bills are likely to be. F G 73 Very environmentally friendly - lower CO2 emissions (92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) A B C D E F G Not environmentally friendly - higher CO2 emissions 75 EU Directive England & Wales 2002/91/EC The environmental impact rating is a measure of a home's impact on the environment in terms of carbon dioxide (CO2) emissions. The higher the rating the less impact it has on the environment.

6 U-value calculator report Page 6 of 8 Survey Reference: 001 Type Ref: Project: Plot 8, Neils View, Maiden Newton SAP Rating: 73 C Software Version: Elmhurst Energy Systems Design SAP 2009 version 4.02r03 Building Elements: Roof Pitched roof - insulated at ceiling Roof Type: Pitched Roof, insulated flat ceiling Layer Description Thickness Lambda R Fraction Ext surface Layer 1 Roof space Main construction 0 mm % Layer 2 Mineral wool Main construction 400 mm % Corrections - Air Gap: Level 0, Fasteners: None or plastic Layer 3 Mineral wool quilt Main construction 100 mm % Bridging - Timber 100 mm % Corrections - Air Gap: Level 0, Fasteners: None or plastic Layer 4 Plasterboard, standard Main construction 13 mm % Int surface Total resistance: Upper limit = m 2 K/W Lower limit = m 2 K/W Average = m 2 K/W U-value (unrounded) = 0.09 W/m 2 K Unheated space: None Total thickness: 513 mm U-value: 0.09 W/m 2 K

7 U-value calculator report Page 7 of 8 Survey Reference: 001 Type Ref: Project: Plot 8, Neils View, Maiden Newton SAP Rating: 73 C Software Version: Elmhurst Energy Systems Design SAP 2009 version 4.02r03 Building Elements: Wall Brickwork Cavity Wall Layer Description Thickness Lambda R Fraction Ext surface Layer 1 Layer 2 Layer 3 Layer 4 Layer 5 Layer 6 Brick, outer leaf Main construction 103 mm % Bridging - Mortar 103 mm % Standard cavity Main construction 50 mm % Corrections - Cavity Unventilated, Emissivity: Low 0.2 Celotex CW4000 Main construction 75 mm % Corrections - Air Gap: Level 1, Fasteners: Wall ties, Cross sectional area: mm 2, Lambda: W/m.K, per m 2 : YTong 4.0 Standard Block Main construction 100 mm % Bridging - Mortar 100 mm % airspace/plaster dabs Main construction 15 mm % Bridging - Mortar 15 mm % Corrections - Cavity Unventilated, Emissivity: Low 0.2 Gyproc Wallboard (12.5mm) Main construction 13 mm % Corrections - Air Gap: Level 1, Fasteners: None or plastic Int surface Total resistance: Upper limit = m 2 K/W Lower limit = m 2 K/W Average = m 2 K/W Unheated space: None U-value (unrounded) = 0.2 W/m 2 K Total thickness: 356 mm U-value: 0.20 W/m 2 K

8 U-value calculator report Page 8 of 8 Survey Reference: 001 Type Ref: Project: Plot 8, Neils View, Maiden Newton SAP Rating: 73 C Software Version: Elmhurst Energy Systems Design SAP 2009 version 4.02r03 Building Elements: Floor Floor - suspended beam-and-block floor Floor Type: Suspended Floor Area = m 2, Perimeter = m, Wall thickness = mm, Soil: Clay Depth of underfloor space below ground:0.200 m Floor wind shielding: Average (suburban) Floor height above ground:h = m U-value of walls above ground:uw = m Ventilation openings per perimeter length:e = % Mean wind speed:v = m/s Resistance on solum:rg = m 2 K/W Layer Description Thickness Lambda R Fraction Ext surface Layer 1 Layer 2 Layer 3 Layer 4 Dense Block/ concrete Main construction 100 mm % Bridging - Mortar 100 mm % Celotex GA4000 Main construction 75 mm % Corrections - Air Gap: Level 1, Fasteners: None or plastic Celotex GA4000 Main construction 75 mm % Chipboard Corrections - Air Gap: Level 1, Fasteners: None or plastic Main construction 22 mm % Int surface Total resistance: Upper limit = m 2 K/W Lower limit = m 2 K/W Average = m 2 K/W Unheated space: None U-value (unrounded) = 0.12 W/m 2 K Total thickness: 272 mm U-value: 0.12 W/m 2 K