Outdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection

Size: px
Start display at page:

Download "Outdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection"

Transcription

1 1Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support

2 2Datasheet Protect your networks from the most brutal environments with Ubiquiti s industrial-grade shielded Ethernet cable, TOUGHCable. Increase Performance Dramatically improve your Ethernet link states, speeds, and overall performance with Ubiquiti TOUGHCables. Extreme Weatherproof TOUGHCables have been built to perform even in the harshest weather and environments. ESD Damage Protection Protect your networks from devastating electrostatic discharge (ESD) attacks. Extended Cable Support TOUGHCables have been developed to increase power handling performance for extended cable run lengths. Bulletproof your networks TOUGHCable is currently available in two versions: PRO Shielding Protection and CARRIER Shielding Protection. TOUGHCable PRO A Category 5e, outdoor, carrier-class shielded cable with an integrated ESD drain wire. TOUGHCable CARRIER A Category 5e, outdoor, carrier class shielded cable that features an integrated ESD drain wire, anti-crosstalk divider, and secondary shielding. It is rated to provide optimal performance on Gigabit Ethernet networks. Additional Information: 24 AWG copper conductor pairs 26 AWG integrated ESD drain wire to prevent ESD attacks and damage PE outdoor-rated, weatherproof jacket Multi-layered shielding Available in lengths of 1000 ft (304.8 m) TOUGHCable Connectors Specifically designed for use with Ubiquiti TOUGHCables and available in 100-pc. bags, TOUGHCable Connectors protect against ESD attacks and Ethernet hardware damage while allowing rapid field deployment without soldering. ESD attacks are the leading cause for device failures. The diagram below illustrates the areas vulnerable to ESD attacks in a network. Unshielded cable with no ESD drain PoE adapter with no earth ground By using a grounded Ubiquiti Power over Ethernet (PoE) Adapter along with Ubiquiti TOUGHCable and TOUGHCable Connectors, you can effectively protect against ESD attacks. Ubiquiti TOUGHCable Ubiquiti PoE Adapter

3 Specifications Level 1 Shielding Protection Cable Ethernet Support Wire Gauge Diameter Insulation Type Insulation Thickness Insulation Diameter Separation (Polyester Wrapping) Cable Shield (Aluminum Foil) Jacket Material Jacket Thickness Jacket Outer Diameter Jacket Color Reference Standard TOUGHCable PRO Specifications CAT5e, Shielded Up to 1 Gbps 24 AWG Solid Bare Copper ± mm Solid PE AVG: 0.26 mm, MIN: 0.25 mm 1.04 ± 0.03 mm Thick: mm, Extent: 20 mm None Thick: mm, Extent: 18 mm 0.4 CCS Yes PE AVG: 0.50 mm, MIN: 0.46 mm 6.0 ± 0.30 mm Gray ISO/IEC 11801, TIA/EIA568B.2 Datasheet Frequency (MHz) RL min. Attenuation PRO Performance NEXT/PSNEXT ACR ELFEXT/PSELFEXT / /18.50 Insulation Separation Cable Shield Weatherproof Jacket 3

4 Specifications 4Datasheet Level 2 Shielding Protection Cable Ethernet Support Wire Gauge Diameter Insulation Type Insulation Thickness Insulation Diameter Separation (Polyester Wrapping) Cable Shield (Aluminum Foil) TOUGHCable CARRIER Specifications CAT5e, Shielded Up to 1 Gbps 24 AWG Solid Bare Copper ± mm Solid PE AVG: mm, MIN: 0.29 mm 1.16 ± 0.02 mm Thick: mm, Extent: 20 mm LDPE: 4.2*0.3 mm Thick: mm, Extent: 20 mm 0.4 TC Secondary Cable Shield (Braid) 16*8*0.16AA Density: 95% Jacket Material Jacket Thickness Jacket Outer Diameter Jacket Color Reference Standard Frequency (MHz) RL min. CARRIER Performance Attenuation NEXT/PSNEXT ACR Yes PE AVG: 0.52 mm, MIN: 0.46 mm 6.8 ± 0.30 mm Gray ISO/IEC 11801, TIA/EIA568B.2 ELFEXT/PSELFEXT / /14.98 Insulation Separation Cable Shield Secondary Cable Shield Weatherproof Jacket

5 Datasheet TERMS OF USE: The Ubiquiti radio device must be professionally installed. Shielded Ethernet cable and earth grounding must be used as conditions of product warranty. It is the installer s responsibility to follow local country regulations, including operation within legal frequency channels, output power, and Dynamic Frequency Selection (DFS) requirements. For further information, please visit All specifications in this document are subject to change without notice. PH Ubiquiti Networks, Inc. All rights reserved. 5