Product Pack. www. mikewye.co.uk T 01409

Size: px
Start display at page:

Download "Product Pack. www. mikewye.co.uk T 01409"

Transcription

1 Product Pack www. mikewye.co.uk T

2 You ll find a reliable partner in NBT and its solutions for the building envelope.

3 NBT are a leading distributor of thermal performance products and solutions that provide; thermal, moisture, acoustic and overheating control. Our specification support helps you ensure the right product specification on a given building type. Successfully used on thousands of UK-based projects; NBT solutions are tried, tested and trusted by house builders, commercial developers, housing associations and local authorities. Thermal performance Good thermal performance is now prerequisite to any new build or renovation. However breathability and overheating control must also be considered simultaneously to protect the integrity of the building fabric and ensure that significant problems are not created. Breathability Over 11 1 / 2 litres of moisture are produced internally by the average household each day. The external shell of a building is much like a coat, it needs to keep the rain off, but like a GORE-TEX jacket, it must not allow moisture, produced internally, to get trapped within the building fabric. It must let it out. Pavatex is the GORE-TEX of buildings. Overheating Low level heat is needed to raise the internal temperature in winter. Insulation keeps this heat in. The sun produces high level heat which can lead to overheating in the summer. Conventional insulation, in structures such as roofs and timber frame buildings, can t keep high level heat out. Pavatex has thermal mass which soaks up the heat from the sun helping to prevent summertime overheating. Contact NBT T E sales@mikewye.co.uk www. mikewye.co.uk Mike Wye & Associates Ltd Buckland Filleigh Sawmills Buckland Filleigh Beaworthy Devon EX215RN

4 Product Sheets Pavatex Woodfibre Membranes 16 Isoroof Isolair Pavatherm Combi Diffutherm Pavadentro Pavadry Pavatherm-Profil Pavatherm Reveal Board NBT Tapes and Seals Tools Fixings Baumit Render Base Coats Render Finishes Insulation Render Lime (Naturplus) Salt Remediation Render Paints, Primers & Sealant Pavaflex 15 Rails & Beads 29 Plinth Board 32 System Sheets New Build Retrofit External Timber Frame Clad External Timber Frame Brick Clad External Timber Frame Render Cross Laminated Timber Render Cross Laminated Timber Clad Pitched Roof Flat Roof IWI* Lime Plastered Finish 48 IWI* Dry Lined Wall 50 EWI** Rendered Wall 52 EWI** Clad Wall 54 Internally Fitted Pitched Roof 56 Externally Fitted Pitched Roof 58 *internal wall insulation **external wall insulation 4

5 Product Sheets T

6 ISOROOF (previously known as ISOLAIR) Universal Woodfibre Insulation Board for cladding or tiling. Application - Roof - over or under rafter Wall - on to studs or existing masonry Finishes - Clad or tile, can be brick clad. Fixed - Mechanical Fixings Storage - Store dry and protected from damage. Only install when dry. Stack no more than 4 pallets on top of each other. Resilience - Can be left exposed up to 90 days Available in full or split pallets Thickn. Weight [kg/sqm] Board dim.# [cm] Number of boards Pallet covers [sqm] per pallet Pallet dim. [cm] [L x W x H] Edge profile x x 77 x 124 T & G x x 77 x 117 T & G Technical data Bulk density ρ [kg/m 3 ] 240 / 230 Thermal conductivity (EN 13171) l D [W/(mK)] / Vapour diffusion resistance coefficient µ 5 Compressive stress at 10% compressive deformation [kpa] 180 / 150 Tensile strength perpendicular to plane of board [kpa] 30 / 10 Product for; NBT Roof System New Build Pages 44 and 46 NBT Clad System New Build Pages 34 and 36 NBT Roof System Retrofit Pages 56 and 58 NBT External Wall Insulation Clad (EWI) Retrofit Page 54 # Dim. without the tongue PAVATEX System Guarantee: Installed as recommended in technical manual with appropriate additional system components. robust & lasting System guarantee 6

7 ISOLAIR Universal Woodfibre Insulation Board for cladding, tiling, plaster and render. Available in full or split pallets Application - Roof - over or under rafter Wall - on to studs or existing masonry Finishes - Clad or tile, can be brick clad. Plaster or Render Fixed - Mechanical Fixings Storage - Store dry and protected from damage. Only install when dry. Stack no more than 4 pallets on top of each other. Resilience - Can be left exposed up to 90 days Thickn. Technical data Bulk density ρ [kg/m 3 ] 200 / 145 Thermal conductivity (EN 13171) l D [W/(mK)] / Vapour diffusion resistance coefficient µ 3 Compressive stress at 10% compressive deformation [kpa] 250 / 100 Tensile strength perpendicular to plane of board [kpa] 30 / 10 Product for; Weight [kg/sqm] Board dim.# [cm] Number of boards Pallet covers [sqm] per pallet Pallet dim. [cm] [L x W x H] Edge profile x x 77 x 124 T & G x x 77 x 124 T & G x x 120 x 124 T & G x x 120 x 124 T & G 120* x x 120 x 124 T & G 140* x x 120 x 124 T & G 160* x x 120 x 124 T & G 180* x x 120 x 124 T & G 200* x x 120 x 124 T & G NBT Pitched Roof System New Build Pages 44 and 46 NBT Clad System New Build Pages 34 and 36 NBT Roof System Retrofit Pages 56 and 58 NBT External Wall Insulation Clad (EWI) Retrofit Page 54 # Dim. without the tongue * Only available in full pallet load PAVATEX System Guarantee: Installed as recommended in technical manual with appropriate additional system components. T robust & lasting System guarantee

8 PAVATHERM COMBI Universal Woodfibre Insulation Board for cladding, tiling, plaster and render. Application - Roof - over or under rafter Wall - on to studs or existing masonry Finishes - Clad or tile, can be brick clad. Plaster or Render Fixed - Mechanical Fixings Storage - Store dry and protected from damage. Only install when dry. Stack no more than 4 pallets on top of each other. Resilience - Can be left exposed up to 60 days Available in full or split pallets Thickn. Weight [kg/sqm] Board dim.# [cm] Number of boards Pallet covers [sqm] per pallet Pallet dim. [cm] [L x W x H] Edge profile 40** x x 120 x 124 T & G x x 120 x 124 T & G x x 120 x 124 T & G Technical data Bulk density ρ [kg/m 3 ] 145 Thermal conductivity (EN 13171) l D [W/(mK)] Vapour diffusion resistance coefficient µ 3 Compressive stress at 10% compressive deformation [kpa] 100 Tensile strength perpendicular to plane of board [kpa] 10 Product for; NBT Pitched Roof System New Build Pages 44 and 46 NBT Clad System New Build Pages 34 and 36 NBT Roof System Retrofit Pages 56 and 58 NBT External Wall Insulation Clad (EWI) Retrofit Page 54 # Dim. without the tongue ** Please contact NBT for exposure and render specification of 40mm boards PAVATEX System Guarantee: Installed as recommended in technical manual with appropriate additional system components. robust & lasting System guarantee 8

9 DIFFUTHERM External Woodfibre Insulation Boards for Render Application - Wall - on to studs, on existing masonry or on CLT frame Finishes - Render Fixed - Mechanical Fixings Storage - Store dry and protected from damage. Only install when dry. Stack no more than 4 pallets on top of each other. Resilience - Can be left exposed up to 60 days, render once dry Available in full or split pallets Thickn. Technical data Weight [kg/sqm] Bulk density ρ [kg/m 3 ] 190 Thermal conductivity (EN 13171) l D [W/(mK)] Vapour diffusion resistance coefficient µ 5 Compressive stress at 10% compressive deformation [kpa] 80 Tensile strength perpendicular to plane of board [kpa] 10 Product for System Board dim. # [cm] Number of boards Pallet covers [sqm] per pallet Pallet dim. [cm] [L x W x H] Edge profile x x 120 x 124 T & G x x 120 x 124 T & G x x 120 x 124 T & G 120* x x 120 x 124 T & G NBT Rendered System New Build Page 38 NBT External Wall Insulation Rendered (EWI) Retrofit Page 52 NBT Render System Cross Laminate Timber New Build Page 40 # Dim. without the tongue * Only available in full pallet load PAVATEX System Guarantee: Installed as recommended in technical manual with appropriate additional system components. robust & lasting System guarantee T

10 PAVADENTRO Internal Woodfibre Insulation (RETROFIT) Application - Wall - masonry, masonry filled timber (internal) Finishes - Single coat NBT lime plaster or clay plaster Fixed - Mechanical fixings & bonding plaster Storage - Store dry and protected from damage. Only install when dry. Stack no more than 4 pallets on top of each other. Available in full or split pallets Thickn. Weight [kg/sqm] Board dim. # [cm] Number of boards Pallet covers [sqm] per pallet Pallet dim. [cm] [L x W x H] Edge profile x x 120 x 115 T & G x x 120 x 115 T & G x x 120 x 115 T & G x x 120 x 115 T & G Technical data Bulk density ρ [kg/m 3 ] 175 Thermal conductivity (EN 13171) l D [W/(mK)] Compressive stress at 10% compressive deformation [kpa] 70 Tensile strength perpendicular to plane of board [kpa] 5 Product for System NBT Internal Wall Insulation (IWI) System Lime Plastered Finish Retrofit Page 48 # Dim. without the tongue 10 PAVATEX System Guarantee: Installed as recommended in technical manual with appropriate additional system components. robust & lasting System guarantee

11 PAVADRY Internal Woodfibre Insulation (RETROFIT) Application - Wall - masonry, masonry filled timber (internal) Finishes - Standard plaster board Fixed - Mechanical fixings & bonding plaster Storage - Store dry and protected from damage. Only install when dry. Stack no more than 2 pallets on top of each other. Available in full or split pallets Thickn. Technical data Weight [kg/sqm] Board dim. # [cm] Number of boards Pallet covers [sqm] per pallet Pallet dim. [cm] [L x W x H] Edge profile x x 120 x 115 T & G x x 120 x 115 T & G x x 120 x 115 T & G Bulk density ρ [kg/m 3 ] (Pavadentro/Hardboard) 175 / 740 Thermal conductivity (EN 13171) l D [W/(mK)] (Pavadentro/Hardboard) / 0.14 Compressive stress at 10% compressive deformation [kpa] (Pavadentro) 70 Tensile strength perpendicular to plane of board [kpa] (Pavadentro) 5 Product for System NBT Internal Wall Insulation (IWI) Retrofit Page 50 # Dimensions without the tongue PAVATEX System Guarantee: Installed as recommended in technical manual with appropriate additional system components. T robust & lasting System guarantee

12 PAVATHERM-PROFIL Internal Woodfibre Insulation Boards Application - Wall, masonry, masonry filled timber (internal) Floor, over or under joists for suspended timber floor or on solid floor with underfloor heating system Finishes - floor boards, screed, use T&G batten to nail floor boards or similar. Wall - single coat NBT lime plaster or clay plaster. Fixed - floating on floor and mechanically fixed on walls. Delivery form optional batten to fix floor boards Storage - Store dry and protected from damage. Only install when dry. Stack no more than 2 pallets on top of each other. Available - Full pallet or broken pallet Thickn. Weight [kg/sqm] Board dim. [cm] Number of boards per pallet [sqm] per pallet Pallet dim. [W x L x H cm] Edge profile x x 120 x 115 T & G x x 120 x 115 T & G Technical data Bulk density ρ [kg/m 3 ] 175 Thermal conductivity (EN 13171) l D [W/(mK)] Vapour diffusion resistance coefficient µ 5 Compressive stress at 10% compressive deformation [kpa] 70 Tensile strength perpendicular to plane of board [kpa] 5 Product for System NBT Suspended Ground Floor System NBT Solid Floor with UHF System NBT Intermediate Floor Solutions The boards can be used as internal wall & ceiling insulation board. Can be finished with Baumit lime plaster or plaster boards. NBT Internal Wall Insulation (IWI) System Lime Plastered Finish Retrofit Page 48 PAVATEX System Guarantee: Installed as recommended in technical manual with appropriate additional system components. robust & lasting System guarantee 12

13 PAVATHERM Woodfibre Insulation Boards 1) Application - Roof - over or under rafter with a base (ply/osb) or on CLT Wall - on to studs with a base or existing masonry or on CLT Floor - between or under joists with a base For all the external application the boards must be protected by appropriate Pavatex primary external boards or membrane. Finishes - Subject to primary boards and application Fixed - Subject to primary boards and application Storage - Store dry and protected from damage. Only install when dry. Stack no more than 4 pallets on top of each other. Available in full or split pallets Thickn. Technical data Weight [kg/sqm] Board dim. [cm] Number of boards Pallet covers [sqm] per pallet Pallet dim. [cm] [L x W x H] Edge profile x x 120 x 124 Flat x x 120 x 124 Flat x x 120 x 124 Flat x x 120 x 124 Flat 120* x x 120 x 124 Flat 140* x x 120 x 124 Shiplap 1) 160* x x 120 x 124 Shiplap 1) Thickness mm on request. Bulk density ρ [kg/m 3 ] 110 Thermal conductivity (EN 13171) l D [W/(mK)] Vapour diffusion resistance coefficient µ 3 ) Compressive stress at 10% compressive deformation [kpa] 50 Tensile strength perpendicular to plane of board [kpa] 2.5 Product for System Secondary board to increase the thickness of NBT Insulation Systems. Please contact NBT for details A solid base (ply/osb) must be used if applied on to rafters or studs Board surface is not suitable for render or plaster Can be used between studs and rafters NBT Render System Cross Laminate Timber Render New Build Page 40 NBT Clad System Cross Laminate Timber Clad New Build Page 42 * only available in full pallet load PAVATEX System Guarantee: Installed as recommended in technical manual with appropriate additional system components. robust & lasting System guarantee T

14 REVEAL BOARD Woodfibre Insulation Reveal Boards Application - Wall - on to studs or existing masonry or on CLT frame Floor - 8mm reveal board can be used as impact sound underlay Finishes - Render/Clad or subject to application Fixed - According to application Storage - Store dry and protected from damage. Only install when dry. Stack no more than 2 pallets on top of one another. Resilience - Can be left exposed up to 60 days Available in full or split pallets Thickn. Technical data Weight [kg/sqm] Board dim. [cm] Number of boards Pallet covers [sqm] per pallet Pallet dim. [cm] [L x W x H] Edge profile x x 120 x 124 Flat x x 120 x 124 Flat x x 120 x 124 Flat Bulk density ρ [kg/m 3 ] 230 / 190 Thermal conductivity (EN 13171) l D [W/(mK)] / Vapour diffusion resistance coefficient µ 5 Compressive stress at 10% compressive deformation [kpa] 130 / 80 Tensile strength perpendicular to plane of board [kpa] 15 / 10 Product for System NBT Clad System New Build Pages 34 and 36 NBT Rendered System New Build Page 38 NBT External Wall Insulation Rendered (EWI) Retrofit Page 52 NBT Internal Wall Insulation (IWI) Retrofit Pages 48 and 50 PAVATEX System Guarantee: Installed as recommended in technical manual with appropriate additional system components. robust & lasting System guarantee 14

15 PAVAFLEX Flexible Woodfibre Insulation Slabs Application - Roof - between rafter Wall - between studs Floor - between joists Finishes - N/A Fixed - Subject to application Storage - Store dry and protected from damage. Only install when dry. Pallets must not be stacked. PAVAFLEX 575 For 600mm Rafter Centres (available in full or split pallets) Thickn. Weight [kg/sqm] Format [cm] pack per pallet batts per pack Packs covers [sqm] Pallet covers [sqm] per pallet Pallet dim. [cm] [L x W x H] T Edge profile x x 115 x 250 Flat x x 115 x 250 Flat x x 115 x 250 Flat x x 115 x 250 Flat * Also available in full pallet quantities in 40, 60, 120, 160, 180, 200, 220, 240mm thickness. Technical data Bulk density ρ [kg/m 3 ] 50 Thermal conductivity (EN 13171) l D [W/(mK)] PAVAFLEX 375 For 400mm Rafter Centres (available in full or split pallets) Thickn. Weight [kg/sqm] Format [cm] pack per pallet batts per pack Packs covers [sqm] Pallet covers [sqm] per pallet Pallet dim. [L x W x H] Edge profile x x 115 x 250 Flat x x 115 x 250 Flat x x 115 x 250 Flat x x 115 x 250 Flat * Please contact for other thicknesses. Generally, full truck only. Technical data Bulk density ρ [kg/m 3 ] 50 Thermal conductivity (EN 13171) l D [W/(mK)] Product for System Flexible insulation used between studs and rafters as part of many of the NBT insulation systems Surface is not suitable for render or plaster PAVATEX System Guarantee: Installed as recommended in technical manual with appropriate additional system components. robust & lasting System guarantee

16 Membranes Breathable Membrane: ADB Breathable membrane with two-way integrated self-adhesive strips. For external use. 0.03m Sd Roll Width Black Breathable membrane: FBA Roll Length Roll Area [m 2 ] External BLACK Breathable membrane. Use Pavatape 12 to seal the overlaps Roll Width Roll Length Roll Area [m 2 ] Roll Weight Roll Weight Air Tight Membrane: DB 3.5 Internal vapour control and airtight membrane. Pavafix 60 tape range & Pavatape flex to seal the overlaps, corners, penetrations etc. 3.5m Sd Roll Width Roll Length Over Rafter/CLT Air Tight Membrane: DSB 2 Roll Area [m 2 ] Roll Weight Vapour control and airtight membrane with two-way integrated self-adhesive strips. Applied from outside of truss roof, CLT or similar. Max. exposure time - 60 days. Use Pavatape 12 to seal vertical overlaps. Roll Width Roll Length Roll Area [m 2 ] Roll Weight Retrofit Membrane: LDB 0.02 Vapour-open airtight membrane with two-way integrated self-adhesive strips. Suitable for existing roof and wall retrofit from outside. min. 35mm insulation on the outside of membrane to avoid condensation Sd Roll Width Roll Length Roll Area [m 2 ] Roll Weight 16

17 Tapes and Seals Pavatape: 75/150 Aluminium-Laminated Butyl rubber tape for external sealing of non-tongue & Groove joints of PAVATEX-boards. PAVABASE or PAVAPRIM primer is required when applying on to wood fibre boards and other porous or mineral surfaces. Box weight Roll length Roll width Pavatape Pavatape Box contents Pavafix 60/20-40/150 Acrylic adhesive tape for sealing internal OSB/ply or membrane for airtightness. Can be used externally when sheltered. Black in colour. Box weight Roll length Roll width Box contents Uses Pavafix Flat joints Pavafix Corners Pavafix All purpose Pavatape FLEX Stretchable butyl rubber tape for internal or external sealing of PAVATEX-boards and membranes at penetrations and complicated junctions. PAVABASE or PAVAPRIM primer is required when applying on to wood fibre boards and other porous or mineral surfaces. Box weight Roll length Roll width Pavatape FLEX Box contents Pavatape 12 Universal double-sided mastic tape for sealing PAVATEX-membranes overlaps and edges to masonry. PAVABASE or PAVAPRIM primer is required when applying on to wood fibre boards and other porous surfaces. Box weight Roll length Roll width Pavatape Box contents T

18 Tapes and Seals Pavafix WIN Plasterable/renderable airtight tape with fleece surface, 3-way split backing tape for indoor/outdoor sealing, especially around openings. Box weight Roll length Roll width Pavafix WIN Box contents Pavafix SN Tape Screw and nail-sealing tape. Prevent the penetration of moisture at nail and screw location under the counter battens. Box weight Roll length Roll width Pavafix SN Band Box contents Pavabase Solvent-free standard adhesive primer for PAVATAPE and other PAVATEX TAPES Contents per container Coverage [ml] Tub m of Pavatape m of Pavatape m of Pavatape Flex 650m of Pavatap m of Pavafix 60 Pavaprim Solvent-free quick dry primer for PAVATAPE and other PAVATEX TAPES Contents per container [ml] Box contents Coverage Bottle m of Pavatape m of Pavatape 75 50m of Pavatape Flex 125m of Pavatape m of Pavafix

19 Tapes and Seals Pavacoll Solvent-free adhesive for sealing PAVATEX boards, membranes and for other wet sealing application. Contents per container (ml) Box contents Accessories included Cartridge snap-off nozzles 26 Tubular bag large conical nozzles Coverage [ml/m] Pavabond High strength connection adhesive cartridge for sealing PAVATEX membranes overlaps and edges to masonry. Contents per container (ml) Box contents Accessories included Cartridge snap-off nozzles 30 Coverage [ml/m] ISO-Bloco 600 High quality joint sealing expansion tape for external use. Tape width Recommended expansion range * Roll length Box contents [unit] 12/ / / *Movement in structural elements and temporary longitude changes are to be taken into account by the max. expansion range. Apart from that, Iso-Chemie general sales conditions are valid ISO-Bloco One 3-in-1 solution The multi-functional gap filling tape with outstanding three-level functionality is 100 % air tight on the inside, provides thermal and sound insulation in the centre and more than 1,000 Pa resistance to driving rain on the outside. Window Frame depth Recommended expansion range ** Roll length 54/ / / / / Box contents [unit] **Expansion range in installed state. For max. expansion value, movement on structural elements and temporary longitude changes should to be taken into account. Apart from this, Iso-Chemie general sales conditions are valid T

20 Tools Jig Saw Blade Special serrated blade for cutting the woodfibre boards. Fits all regular makes (Bosch, AEG, ELU, Festo, Metabo, Makita, etc). Length Pack Content Box Content Blades 3 Packs (15 Blades) Insulation Knife for Pavaflex Special knife for cutting Pavaflex. Length Pack Content Blades Reciprocating Saw Blade Special serrated blade for cutting the woodfibre boards. Fits all regular makes (Bosch, AEG, ELU, Festo, Metabo, Makita, etc). Length Pack Content Box Content Blades 3 Packs (15 Blades) 20

21 Fixings STR H Thermally broken washer, self-tapping fixings to anchor wall Insulation systems for timber and sheet steel (max. 0.75mm) substrate. Length With the increment of 20mm Thread Diameter Washer Diameter Drive System 6 60 TORX T25 Box Contents Timber Embedment Included STR-U PLUG H1 eco (Previously known as NTU) Thermally broken washer, nylon plug with steel pin (hammer action) fixings to anchor wall Insulation systems for solid masonry substrate. Length With the increment of 20mm Drill Hole Diameter Washer Diameter Drive System 8 60 Hammer-in anchor Box Contents Masonry Embedment STR U Thermally broken washer, nylon sleeve, self-tapping fixings to anchor wall Insulation systems for light weight or solid masonry substrate. Length with 20mm increment Drill Hole Diameter Washer Diameter Drive System 8 60 TORX T30 Box Contents Masonry Embedment Required component [separate order] to 65 STR-U PLUG H3 Thermally broken washer, nylon plug with nylon pin (hammer action) fixings to anchor Internal Wall Insulation systems for solid masonry substrate. Length with the increment of 20mm Drill Hole Diameter Washer Diameter Drive System 8 60 Hammer-in anchor Box Contents Masonry Embedment T

22 Fixings Heco-Topix Countersunk Countersunk head with milling grooves, part threaded bright zinc plated and self-tapping fixings for timber substrate. To fix woodfibre insulation onto Cross Laminated Timber (CLT) or timer. Contact for fixings calculations. Length 6 Dia & 8 Dia with 20mm increment Thread Diameter Drive System 6 & 8 TORX T25 & TORX T40 Box Contents Timber Embedment 100 (2 x 50) 40 or as calculated Heco-Topix Therm Countersunk Countersunk head with milling grooves, double threaded bright zinc plated and self-tapping fixings for timber substrate. To provide, additional load support on roof insulated with woodfibre insulation onto Cross Laminated Timber (CLT) or timber rafters. Contact for fixings calculations. Length with 20mm increment Thread Diameter Drive System Box Contents Timber Embedment 8 TORX T (2 x 50) 40 or as calculated VHT R 4.8 SW8 R 4.8 Counter sunk, self-drilling and self-tapping fixings for timber and sheet steel substrate. Length with 20mm increment Thread Diameter Drive System 4.8 P2 Recess Steel Drilling Also available in stainless steel - please contact NBT Box Contents Timber Steel Embedment Embedment Hex head, self-drilling and self-tapping fixings for timber and sheet steel substrate. Length 60, with 10mm increment & with 20mm increment Thread Diameter Drive System 4.8 Hexagon A/F8 8mm Steel Drilling Box Contents Timber Embedment Steel Embedment 22

23 Fixings Spiral Anchor (Spiraldubel) Fastening solution for light fixtures onto rendered or plastered insulation system for all substrates. Length Drill Hole Diameter Washer Diameter Drive System Box Contents Embedment TORX T40 10 Full length MRS-U Self-tapping, counter sunk wall screw with pre drill hole for solid masonry substrate. Length 100, 120, 135, 150 & 180mm Thread Diameter Drill Hole Diameter Drive System Box Contents TORX T Masonry Embedment* MQL-ST plug & screw Nylon sleeve, screw, counter sunk fixings for light weight and solid masonry substrate. Length Drill Hole Diameter Drive System with the 8 TORX increment of 20mm T30/T40 Box Contents Masonry Embedment Insulation Washers SBL & VT washer KC washer SBL & VT are load spreading disc washers to secure the insulation board edges at external corners and around openings where the substrate is far from the board edges. KC washers are used in conjunction with recommended timber/steel fixings for Render and Plaster insulation systems. Product Washer Diameter SBL VT KC Box Contents T

24 Baumit Render Base Coats MC55 W Mineral enriched base coat render recommended for Pavatex Woodfibre boards, and as high adhesion bonding render. Grain Size Colour Bag Size Consumption [kg/sqm/mm] Coverage/bag [sqm/6mm] mm buff/cream Bag per pallet MP69 Light weight base coat render recommended for NBT ThermoPlan and on other masonry substrates. Grain Size Colour Bag Size Consumption [kg/sqm/mm] Coverage/bag [sqm/18mm] mm Grey Bag per pallet SpeedFill Super-fast setting, lightweight filling mortar with low thermal conductivity and low shrinkage for voids up to 150mm deep. A time saving option for dubbing out deep indentations in uneven walls behind Pavadentro or Pavadry: Ready for additional coat of RK38 after 24 hours (one week drying requirement for directly applied plaster finishes). Thermal Conductivity W/mK Grain size Colour Bag Size [L] Yield [L/Bag] Setting Time [min] Grey Bags per Pallet 24

25 Baumit Render Finishes SilikonTop Pre-mixed, highly water repellent top coat with high vapour permeability For application over old and new mineral coatings and concrete surfaces. Primer required. Grain Size Colour Tub Size Consumption [kg/sqm/grain size] Coverage/ Tub [sqm] Fine* 1 White & Colour K White & Colour K 2 2 White & Colour K 3 3 White & Colour * consumption = 1.7kg/m2, coverage=14.7m2 with receiver coat of K1.5 silicon Tub per pallet SEP and KWP Lime based top coat render applied on to Baumit base coat renders. Produces a choice of textured finishes. Recommended to over paint to combat lime bloom and add water repellancy. Grain Size Colour Bag Size Consumption [kg/sqm/grain size] Coverage/ bag [sqm] SEP 01 1 White & Colour SEP 02 2 White & Colour SEP 03 3 White & Colour SEP 04 4 White & Colour KWP 0-5 White & Colour Bag per pallet Baumit Insulation Render DP 85 Thermally insulating breathable cement lime render, applied as a single or multiple basecoat application in external and internal areas of old and new buildings,. DP 85 can be applied directly to uneven backgrounds as a standalone insulation layer (30-100mm), as additional thermal resistance for Thermoplan blocks, or as a dubbing out coat prior to installing woodfibre boards. Thermal Conductivity W/mK Grain Size mm EPS Colour Bag Size Grey 9 (54 litres mixed) Consumption [l/sqm/mm] Coverage/ bag [sqm@30mm] Bags per Pallet T

26 Baumit Lime (Naturplus) RK38 Pure lime plaster for internal application on all types of masonry: used as base-coat, dubbing out prior to NBT Woodfibre IWI, and coarse finish. Grain Size Colour Bag Size Consumption [kg/sqm/mm] Coverage/bag [sqm/10mm] White Bag per pallet RK70 Lime based internal base coat finish plaster on to Woodfibre boards. Also used as internal bonding coat (adhesive) and external fine finish. Grain Size Colour Bag Size Consumption [kg/sqm/mm] Coverage/bag [sqm/10mm] White Bag per pallet RK30 K Glatt Fine skimming plaster for smooth finish on various internal surfaces. Grain Size Mostly stone dust Colour Bag Size Consumption [kg/sqm/mm] Coverage/bag [sqm/2mm] White Bag per pallet RK39 Pure lime render/plaster for internal & external application on to all type of masonry walls. Can be used as levelling coat prior to NBT Woodfibre application. Grain Size Colour Bag Size Consumption [kg/sqm/mm] Coverage/bag [sqm/10mm] 0-3 Off white Bag per pallet 26

27 Baumit Salt Remediation Render HiQ Basic / SP 64 P Salt remediation base coat render/plaster for sulphate/nitrate contaminated masonry; a breathable alternative to tanking (component of system - contact NBT). Grain Size Colour Bag Size Consumption [kg/sqm/mm] Grey Coverage/bag [sqm/20mm] SV 61 (Renovation Spatterdash Coat) Provides a keying coat on to damp, salt-contaminated masonry substrates (brickwork, natural stone) to improve adhesion and equalize background suction. Grain Size Colour Bag Size Consumption, 50-60% sporadic coat [kg/sqm/mm] 0 4 Grey Coverage/bag [sqm] T

28 Baumit Paints, Primers & Sealant External Paints: Artline Silicat A highly vapour permeable (µ 50) protective, decorative paint for old and new facades. Recommended paint for SEP, KWP, MC55, and RK39 topcoats. Standard white (stocked) is Baumit Life code Consumption depends on texture of render grain. Colour Tub Size [L] Approximate Consumption [L/sqm/coat] Aprrox. Coverage/Tub coats] White & Colour White & Colour Tubs per Pallet Primers: DG27 - Premium Primer Ready to use, vapour permeable liquid primer with aggregate for hand application for internal and external areas. Reduces and equalizes substrate suction to improve the curing and strength development of subsequent coatings as well as colour uniformity. Improves adhesion to substrates. Enhances the hydrophobic qualities of the background. Does not inhibit water vapour diffusion through the substrate. Acrylic based and free of solvents. Tub Size [L] Colour 10 white (tinted available) Typical Consumption [L/sqm/coat] Aprrox. Coverage/Tub [sqm/coats] Tubs per Pallet Sealant: DS27 Adhesive and sealing product for bonding XPS plinth and perimeter boards below DPC and as waterproof sealant below ground. Mixed 1;1 with Portland cement. Applied on the back (@ min. 40% coverage) of the plinth boards for bonding and on the front below ground level following base-coat render as sealant. Product is moisture-resistant and water-vapour permeable, with high bond strength. Suitable for bitumen or masonry substrates. Colour Tub Size Off-White 18 Typical Consumption 1:1 with cement [Kg/m 2 ] 2 as bonding 0.7 as sealant Approx. Coverage/Tub (m 2 ) [sqm] 7.7 front & back application on half buried plinth Tubs per Pallet

29 Rails & Beads Base Profiles: Aluminium Base Rail Base profiles for render insulation system. Insulation Thickness With an increment of 20m Clear Width With an increment of 20mm Length Box Contents up to 100mm, 6 120mm and above Also available in stainless steel - please contact NBT Base Profiles: PVC Base Rail Drip Clip with mesh Drip clip with integrated mesh to go on the base rail to create a render drip. Render Depth Length Box Contents Base Profiles: PVC Base Profile (Adjustable) Two part system with built-in drip and mesh, have been designed to cut thermal bridging and are adjustable to suit wall thicknesses. Insulation Thickness Range Render Depth Length 37510A Box Contents Base Profiles: PVC Base & Stop Profile One part PVC base profiles with built-in mesh and drip. Designed to slide between two materials or for fixing to substrate for render return. Width Render Depth Length Box Contents T

30 Rails & Beads Stop Profiles: Aluminium System Stop Profile Insulation system stop profile with built-in render stop. Insulation Thickness With an increment of 20mm Clear Width With an increment of 20mm Length Box Contents Window Frameseal Beads: PVC Window Frameseal Bead (APU rail) Self-adhesive PVC profile for use on window reveals or door frames for crack free render stop. Render Depth Meshed Length YES Box Contents Corner Beads: PVC Corner mesh bead Corner mesh bead with alkali resistance glass fibre mesh wings. Wings [mm x mm] Angle Length x º x º to 180º 50 1 Roll Box Contents Corner Beads: PVC Corner mesh bead with nosing Wings [mm x mm Angle Render Depth Length x º Box Contents Corner Beads: PVC Window head/balcony Drip Bead with mesh Window head and balcony corner mesh bead with in-built drip profile and alkali resistance glass fibre mesh wings. Render Depth Length Box Contents

31 Rails & Beads PVC Render Stop Beads: Meshed Wing Wing Length Render Depth Length Box Contents PVC Bell Cast Bead: Perforated Wing Render Depth Length D D Box Contents PVC Render Movement Beads: Meshed Wing Render Depth Length Box Contents PVC System Movement Bead Insulation expansion joint profiles with soft PVC centre section for insulation systems, with alkali-resistance glassfibre mesh. Recommended for vertical movements +/- 5mm. Profile Render Depth Length 3035 Level Corner Box Contents Render only Compression Joint (Horizontal) Render only compression joint for thin coat render. Ideally suited to timber framed buildings. The aluminium base section is supplied pre-coated white, but can be powder coated to any colour if required. Corner and Joint products are available on request. Render Depth PVC with Mesh [Ref Number] Powder Coated Aluminium [Ref Number] Length Top Section Base Section Quantity [Per Box] T

32 Rails & Beads PVC Render Façade Flashing Bead Render bead to retrofit metal flashing. Length Box Contents Flashing: EWI Eave Cap, Powder coated to any RAL colour Eaves cap for roofs with no overhang - (upstand fixed behind fascia board to wall or wall plate) OR as proud plinth drip where not insulating plinth). Material A Length Box Contents WEC721/90 1.2mm Aluminium on order WEC721/ mm Aluminium on order WEC721/ mm Aluminium on order Other alternative flashing profiles available, including end caps. Contact NBT Ventilation Profiles: Roof Eaves Vent Profiles Reinforcing Mesh Material Plinth Board NBT Plinth and Perimeter Boards Eave vent profile to go under the counter battens at the eaves. Dim A Dim B Length 9071 Mill finished Aluminium Black coated Aluminium Other wing sizes also available Box Contents Alkali resistant fibre mesh for render and plaster Insulation System. Mesh aperture Weight [g/m2] Roll Size [m x m] 4 x x 1 Also available in heavy duty for extra impact resistance, Please contact NBT Thickness Board Dimensions Boards per Pack Pack Covers [m2] x x x x

33 System Sheets T

34 New Build System for Timber Frame Clad System Performance u - values y values airtightness 5 The system complies with the most stringent of standards from baseline building regulations through to Passivhaus. The system is suitable for all external clad finishing options including brick, stone, timber, zinc, etc. All components for the system are available from NBT. Plan-section of system Out In 1. Cladding system (timber, brick, screen etc.) 2. Battened to create a 40mm ventilated void 3. NBT ISOROOF 20/35 mm or NBT PAVATHERM-PLUS + 60/80/100/120 mm 4. Stud & NBT PAVAFLEX 5. Racking board incl. airtightness detail (e.g. OSB 12/15 mm) 6. Service void 25 mm - optional (can be insulated for improved performance) 7. Plasterboard 12.5 mm 8. Plaster, skim and NBT emulsion paint How NBT systems compare to standard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

35 Components & Accessories for NBT System for Timber Frame: Clad P6,7,8 2 P Isolair, Pavatherm-Combi or Isoroof Pavaflex 3 3 P22 4 P TKR Pavatape 150, external 5 P18 6 P Pavabase primer ISO-Bloco P32 8 P Plinth board (XPS) MC 55 External Base Coat 9 P32 10 P28 Render and Plaster Mesh Primer 11 P25 12 P28 * Please refer to or the contents page of this pack to find more information about the range of NBT products External Top Coat DS 27 System build up T

36 New Build System for Timber Frame Brick Clad System Performance u - values y values airtightness 5 Plan-section of system The system complies with the most stringent of standards from baseline building regulations through to Passivhaus. The system is suitable for most external clad options inclusing brick & stone. All components for the system are available from NBT. 1. Brick Clad 2. Brick Ties 3. Timber Batten 4. NBT ISOROOF 20/35 mm or NBT PAVATHERM-PLUS + 60/80/100/120 mm 5. Stud & NBT PAVAFLEX 6. Racking board incl. airtightness detail (e.g. OSB 12/15 mm) 7. Service void 25 mm - optional (can be insulated for improved performance) 8. Plasterboard 12.5 mm 9. Plaster, skim and NBT emulsion paint How N BT systems c ompare to st andard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

37 Components & Accessories for NBT System for Timber Frame: Brick Clad 6 1 P6,7,8 2 P15 6 Isolair, Pavatherm-Combi or Isoroof Pavaflex 2 3 P21 4 P STR-H (for temporary fixing of the boards) Pavatape 150, external 7 5 P18 6 P Pavabase primer ISO-Bloco Ancon 25/14 Restraint System** * Please refer to or the contents page of this pack to find more information about the range of NBT products ** Not supplied by NBT System build up T

38 New Build System for Timber Frame Render System Performance u - values y values The system complies with the most stringent of standards from baseline building regulations through to Passivhaus. The system is available in an extensive number of render options including, colour, texture and weathering resistance. All components for the system are available from NBT. Plan-section of system Out In 1. NBT 2-coat render system 2. NBT DIFFUTHERM 60/80/100/120mm 3. Stud fully filled with NBT PAVAFLEX 4. Racking board incl. airtightness detail (eg OSB 12/15mm) 5. Service void 25 mm (can be insulated for improved performance) 6. Plasterboard 12.5 mm 7. Plaster, skim and NBT emulsion paint How NBT systems c ompare to st andard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

39 Components & Accessories for NBT System for Timber Frame: Render 1 P15 2 P7, Pavaflex Diffutherm or Isolair P24 4 P MC 55 External Base Coat Render & Plaster Mesh 5 P28 6 P25 9 Primer (for pre-mixed top coat) External Top Coat P29 8 P Base Rail 9 P21 APU Mesh Window Stop Bead 10 P19 * Please refer to or the contents page of this pack to find more information about the range of NBT products STR-H ISO-Bloco P32 12 P30 13 P28 Plinth board (XPS) PVC Corner Mesh DS 27 System build up T

40 New Build System for Cross Laminated Timber Render System Performance u - values y values The system complies with the most stringent of standards from baseline building regulations through to Passivhaus. The system is available in an extensive number of render options including, colour, texture and weathering resistance. All components for the system are available from NBT. Plan-section of system Out In 1. NBT 2-coat render system 2. NBT DIFFUTHERM 60mm 3. NBT PAVATHERM 80/100/120/140mm or more 4. CROSS LAMINATED TIMBER STRUCTURE How NBT systems c ompare to st andard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

41 Components & Accessories for NBT System for Cross Laminated Timber: Render 8 1 P13 2 P7, Pavatherm Diffutherm or Isolair P24 4 P MC 55 External Base Coat Render & Plaster Mesh 9 5 P28 6 P Primer (for pre-mixed top coat) External Top Coat 7 P29 8 P30 Base Rail APU Mesh Window Stop Bead 9 P21 10 P19 * Please refer to or the contents page of this pack to find more information about the range of NBT products STR-H ISO-Bloco P17 12 P32 13 P30 14 P28 Pavafix 60 Tape Plinth board (XPS) PVC Corner Mesh DS 27 System build up T

42 New Build System for Cross Laminated Timber Clad System Performance u - values y values airtightness 5 The system complies with the most stringent of standards from baseline building regulations through to Passivhaus. The system is suitable for all external clad finishing options including brick, stone, timber, zinc, etc. All components for the system are available from NBT. Plan-section of system Out In 1. Cladding system (timber, brick, screen etc.) 2. Battened to create a 50mm ventilated void 3. NBT ABD (red) or FBA (black) membrane 4. NBT PAVATHERM 80/100/120/140mm or more 5. CROSS LAMINATED TIMBER STRUCTURE How NBT systems compare to standard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

43 Components & Accessories for NBT System for Cross Laminated Timber: Clad 11 1 P13 2 P16 3 Pavatherm 3 P17 ADB Breathable Membrane 4 P Pavafix 60 Tape Pavafix 150 Tape P18 6 P Pavabase primer MC 55 External Base Coat 7 P32 8 P28 Render and Plaster Mesh Primer 9 P25 10 P28 External Top Coat DS P14 12 P22 * Please refer to or the contents page of this pack to find more information about the range of NBT products Reveal Board HECO Topix Countersunk System build up T

44 New Build System for Roof Pitched System Performance u - values y values airtightness 5 The system complies with the most stringent of standards from baseline building regulations through to Passivhaus. The system is suitable for most external finishing options including metal, clay or slate tiling etc. All components for the system are available from NBT. Cross-section of system Out In 1. Roofing (tiles, slates, tile batten etc.) 2. Counter battens 50 x 38 mm 3. NBT ISOROOF 20/35 mm or NBT PAVATHERM-PLUS+ 60/80/100/120 mm 4. Rafters fully filled with NBT PAVALFLEX 5. OSB (support &. airtightness) 6. Service void 25 mm - optional (can be insulated for improved performance) 7. Plasterboard 12.5 mm with skim and NBT emulsion paint How NBT systems compare to standard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

45 Components & Accessories for NBT System for Roof: Pitched Pitch 18 o 7 1 P6,7,8 2 P15 3 P22 4 P17 Isolair, Pavatherm-Combi or Isoroof Pavaflex Ejot: TKR Pavatape 75 5 P18 6 P17 Pavabase primer Pavatape P32 * Please refer to or the contents page of this pack to find more information about the range of NBT products Eaves Vents System build up T

46 New Build System for Roof Flat System Performance u - values y values airtightness 5 The system complies with the most stringent of standards from baseline building regulations through to Passivhaus. The system is suitable for most external finishing options including sedum, metal, timber or similar decking. All components for the system are available from NBT. Cross-section of system Finish covering (such as green roof or gravel) 2. EPDM 3. WBP Plywood 4. Battens for ventilation (100mm) 5. Breathable roofing membrane 6. NBT ISOROOF / PAVATHERM-PLUS 7. Rafters / NBT PAVAFLEX 8. Airtightness membrane (taped) 9. Service void 25mm 10. Plasterboard 12.5mm How NBT systems compare to standard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

47 Components & Accessories for NBT System for Roof: Flat Pitch 3 o 1 P6,7,8 2 P15 3 P22 4 P16 Isolair, Pavatherm-Combi or Isoroof Pavaflex Heco Topix-Therm, double threaded fixings ADB Breathable Membrane 5 P17 6 P18 7 P18 Pavatape Pavabase primer Pavatex SN Band, Screw sealing tape * Please refer to or the contents page of this pack to find more information about the range of NBT products System build up T

48 Retrofit System for Internal Wall Insulation Lime Plastered Finish System Performance u - values airtightness 5 A highly effective solution that eliminates the moisture risk associated with IWI. NBT IWI systems use Pavadentro to provide active moisture control through absorption and redistribution of moisture within a woodfibre board and integral mineral layer. The system combines the best of modern technological advances with natural, traditional materials; finished with a two-coat lime plaster that perfectly compliments traditional and modern wall finishes. Plan-section of system Out In 1. External wall (masonry/stone) 2. NBT absorbent plaster (min 5mm) 3. NBT PAVADENTRO 4. Two-coat meshed lime finish How NBT systems compare to standard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

49 Components & Accessories for NBT Internal Wall Insulation System Lime Plastered Finish 1 P10,12 2 P Pavadentro or Pavatherm-Profil RK70 Internal Bonding & Base Coat 3 P26 4 P Internal Top Coat RK38 Internal Levelling Coat (Optional) 3 5 P32 6 P30 2 Render & Plaster Mesh PVC Corner Mesh Bead with Nosing 4 OPTIONAL 7 P21 8 P18 Ejot H3 Pavatex WIN Tape 9 P14 Reveal Board * Please refer to or the contents page of this pack to find more information about the range of NBT products System build up T

50 Retrofit System for Internal Wall Insulation Dry Lined System Performance u - values airtightness 5 A highly effective solution that eliminates the moisture risk associated with IWI. NBT IWI systems use Pavadry to provide active moisture control through absorption and redistribution of moisture within a woodfibre board and integral mineral layer. The system incorporates a composite board, that is drylined with plasterboard, providing a load bearing surface. Installed and made good within a day, the system provides a clean lined modern finish. Plan-section of system Out In 1. External wall (masonry/stone) 2. NBT absorbent plaster (min 5mm) 3. NBT Pavadry 4. Plasterboard or Fermacell board How NBT systems compare to standard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

51 Components & Accessories for NBT Internal Wall Insulation System Dry Lined 1 P11 2 P Pavadry RK70 Internal Bonding & Base Coat 3 P26 4 P24 1 RK38, Internal Levelling Coat (Optional) Speedfill (Optional) 5 P23 6 P MRS-U Pavafix WIN, plaster tape 3 or 4 Optional 7 P21 8 P14 Ejot H3 Reveal Board P17 Pavafix 20/40 and Pavafix 60 Internal Tape * Please refer to or the contents page of this pack to find more information about the range of NBT products System build up T

52 Retrofit System for External Wall Insulation Rendered System Performance u - values y values airtightness 5 The system complies with the most stringent of standards from baseline building regulations through to Passivhaus. The system is available in an extensive number of render options including, colour, texture and weathering resistance. All components for the system are available from NBT. Plan-section of system Out In 1. NBT 2-coat render system 2. NBT DIFFUTHERM 60/80/100/120mm or more 3. Masonry substrate 4. Plaster How NBT systems compare to standard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact 52 Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

53 Components & Accessories for NBT External Wall Insulation System: Rendered P7,9 2 P Diffutherm or Isolair MC55, External Base Coat P25 4 P External Top Coat Primer 1 5 P32 6 P29 8 Render and Plaster Mesh Base Rail P30 8 P APU Mesh Window Stop Bead H1 eco (Previously known as NTU) 9 P19 10 P32 11 P30 ISO-Bloco Plinth board (XPS) Corner Mesh 12 P28 13 P14 * Please refer to or the contents page of this pack to find more information about the range of NBT products DS 27 Reveal Board System build up T

54 Retrofit System for External Wall Insulation Clad System Performance u - values y values airtightness 5 Plan-section of system Out In The system complies with the most stringent of standards from baseline building regulations through to Passivhaus. The system is suitable for all external clad finishing options including brick, stone, timber, zinc, etc. All components for the system are available from NBT. 1. Cladding system (timber, brick, screen etc.) 2. Battened to create a 40mm ventilated void 3. NBT Pavatherm-Plus + 60/80/100/120mm or more 4. Masonry substrate 5. Plaster How NBT systems c ompare to st andard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

55 Components & Accessories for NBT External Wall Insulation System: Clad 6 1 P6,7,8 2 P Isolair, Pavatherm-Combi or Isoroof MQL-ST 3 P17 4 P18 Pavatape 150, External Pavabase Primer 1 5 P19 6 P ISO-Bloco Reveal Board 7 P32 8 P Plinth board (XPS) 9 P32 MC 55 External Base Coat 10 P28 Render and Plaster Mesh Primer 11 P25 12 P28 * Please refer to or the contents page of this pack to find more information about the range of NBT products External Top Coat DS 27 System build up T

56 Retrofit System for Roof Pitched Internally Fitted System Performance u - values y values airtightness 5 Cross-section of system A B The system complies with the most stringent of standards from baseline building regulations through to Passivhaus. The system is suitable for most internal finishing options including lime plaster, clay plaster or plaster board finish. All components for the system are available from NBT. 1. Existing tiles/slates 2. Existing non-breathable felt 3. New treated timber battens (min. 45mm height), fixed to existing rafters to create ventilation area 4. NBT system glue (to seal battens to rafters and woodfibre boards to battens 5. NBT ISOROOF or NBT PAVATHERM-PLUS fixed to the battens 6. NBT PAVAFLEX between battens 7. NBT PAVATHERM-COMBI 8. a) NBT lime-based plaster system b) Airtightness membrane; service void and plasterboard How NBT systems compare to standard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

57 Components & Accessories for NBT System for internally Fitted Roof: Pitched 1 P6,7 2 P15 Isolair or Isoroof Pavaflex 3 P16 4 P7, NBT Airtightness membrane Pavatherm-Combi or Isolair P19 6 P Pavacoll adhesive Pavatape P18 8 P22 Pavabase Primer Ejot: TKR * Please refer to or the contents page of this pack to find more information about the range of NBT products System build up T

58 Retrofit System for Roof Pitched Externally Fitted System Performance u - values y values airtightness 5 The system complies with the most stringent of standards from baseline building regulations through to Passivhaus. The system is suitable for most external finishing options including metal, clay or slate tiling etc. All components for the system are available from NBT. Cross-section of system Existing/reclaimed/ new tiles/slates 2. Tile batten 3. New counter batten (min. 25 for ventilation). Please contact for metal roof. 4. NBT Isoroof or Pavatherm Plus 5. NBT LDB 0.02 retrofit membrane 6. NBT Pavaflex between existing rafter 7. Existing Plasterboard or similar finish How NBT systems compare to standard build Thermal performance Summertime Heat Protection Sound insulation Breathability Very low environmental impact Natural Building Technologies The Hangar, Worminghall Road, Oakley, Buckinghamshire HP18 9UL info@natural-building.co.uk

59 Components & Accessories for NBT System for Externally Fitted Roof: Pitched P6,7 2 P16 3 P15 4 P22 Isolair or Isoroof LDB 0.02 retrofit membrane Pavaflex Ejot: TKR 5 P17 6 P17 7 P18 8 P17 Pavafix tape Pavatape 75 Pavabase primer Pavatape 150 * Please refer to or the contents page of this pack to find more information about the range of NBT products System build up T

60 Contact Mike Wye & Associates Ltd Buckland Filleigh Sawmills Buckland Filleigh Beaworthy Devon EX215RN T E sales@mikewye.co.uk www. mikewye.co.uk 03/18