6" TRIM AT GARAGE DOORS (TYP) 6" TRIM (TYP) OPTIONAL PATIO DOOR

Size: px
Start display at page:

Download "6" TRIM AT GARAGE DOORS (TYP) 6" TRIM (TYP) OPTIONAL PATIO DOOR"

Transcription

1 GABLE END x0 TRIM (TYP) A6. PTD. ALUM GUTTER (TYP) MODEL 67 - OVATION MODEL - BRAVO '- /8" 00'-0" " WATER 6" CORNER TRIM (TYP) 6" TRIM AT GARAGE DOORS (TYP) OPTIONAL PATIO DOOR AMERICAN TRADITIONAL MATERIALS: -THIN SET SQUARE CUT OR HORIZONTAL STONE -8" MAXIMUM EXPOSURE HORIZONTAL SMOOTH SIDING DESIGN ELEMENTS: MULTI-FAMILY RESIDENTIAL MUST COMPLY WITH AT LEAST 5 OF THE STANDARD AND DESIGN ELEMENTS. THIS DESIGN MEETS THE FOLLOWING DESIGN ELEMENTS:. FRONT AND REAR FACING MAIN GABLE TO HAVE DECORATIVE S.. MINIMUM 6" CORNER BOAR AT EXTERIOR CORNERS.. PORCH POST TO BE MINIMUM OF 8" SQUARE OR ROUND WITH DECORATIVE TRIM AT TOP AND BOTTOM.. A MINIMUM OF ONE PLANE BREAK ON AT LEAST TWO FACADES. PLANE BREAK MAY BE HORIZONTAL OR VERTICAL. 5. UPPER GARAGE DOOR PANEL WITH DIVIDED LIGHT PATTERN TOTAL SURFACE AREA BUILDING =,68 SF TOTAL STONE SURFACE BUILDING =,76 SF PERCENT STONE PROVIDED = 5% PERCENT STONE REQUIRED (THORNTON) = 5% MIN TOTAL GLAZING PROVIDED > SF FOR EACH STREET FACING FACADE TOTAL GLAZING REQUIRED (THORNTON) = SF MIN EACH STREET FACING FACADE 8" LAP CEMENTITIOUS SIDING (TYP) COMP. ASPHALT SHINGLES (TYP) PTD. ALUM. GUTTER (TYP) MODEL - BRAVO MODEL 67 - OVATION GABLE END (BUILDING TYPE ) GARAGE ELEVATION /6" = '-0" 0 ' 8' ' 09'- /8" CO-088 THIN MANUF. STONE SIDING (TYP) " WATER 6" CORNER TRIM (TYP) '-0" ELECTRICAL SERVICE PANEL THIN MANUF. STONE SIDING (TYP) WOOD COLUMN 00'-0" (BUILDING TYPE ) ENTRY ELEVATION /6" = '-0" 0 ' 8' ' --6 COPYRIGHT 06 COMP. ASPHALT SHINGLES (TYP) Revision 6--5 Revision -8-6 Revision --6 " GUTTER (TYP) 6" CORNER TRIM (TYP) " WATER TABLE (TYP) 09'- /8" 00'-0" 09'- /8" 00'-0" (BUILDING TYPE ) INSET ELEVATION (BUILDING TYPE ) INSET ELEVATION /6" = '-0" /6" = '-0" " GUTTER (TYP) 6" CORNER TRIM (TYP) " WATER BLDG ELEVATIONS A.

2 7 A6. A. A6. UNIT 8 - BRAVO MINIMUM AREA AS PER IRC R806. REQUIRED ILATION = ATTIC AREA / 00 6 SF / 00 = 8 SF EAVES UNIT 6 - OVATION MINIMUM AREA AS PER IRC R806. REQUIRED ILATION = ATTIC AREA / 00 6 SF / 00 = 8 SF EAVES A. '-0" A. AREA INDICATES COMPLIANCE W/ IRC 0 R0.. EXCEPTION - IN LIEU OF PARAPET WALLS THE ROOF SHEATHING IS NOTED AS BEING FIRE RETARDANT TREATED WOOD FOR A MINIMUM OF FEET FROM THE PROPERTY LINE WHICH DOES NOT ALLOW FOR PENETRATIONS OF S AND INTAKES 9.' BUILDING ENVELOPE " % SLOPE, TYP., W/ " MIN. DIA. LEADER PER 0 INTERNATIONAL PLUMBING CODE SEC. 06 ROOF TYPE: R '-0" A. /" / " /" / " UNIT 6 - OVATION MINIMUM AREA AS PER IRC R806. REQUIRED ILATION = ATTIC AREA / 00 6 SF / 00 = 8 SF EAVES '-0" '-0" A. UNIT 8 - BRAVO MINIMUM AREA AS PER IRC R806. REQUIRED ILATION = ATTIC AREA / 00 6 SF / 00 = 8 SF EAVES A. " % SLOPE, TYP., W/ " MIN. DIA. LEADER PER 0 INTERNATIONAL PLUMBING CODE SEC ' BUILDING ENVELOPE COPYRIGHT 06 CO Revision -8-6 Revision --6 '-0" ROOF PLAN (BUILDING ) /6" = '-0" 0 ' 8' ' BLDG ROOF PLAN A.

3 GABLE END x0 TRIM (TYP) A6. MODEL 95 - APPLAUSE MODEL 95 - APPLAUSE PTD. ALUM GUTTER (TYP) 09'- /8" 00'-0" " WATER 6" CORNER TRIM (TYP) 6" TRIM AT GARAGE DOORS (TYP) THIN MANUF. STONE SIDING (TYP) AMERICAN TRADITIONAL MATERIALS: -THIN SET SQUARE CUT OR HORIZONTAL STONE -8" MAXIMUM EXPOSURE HORIZONTAL SMOOTH SIDING DESIGN ELEMENTS: MULTI-FAMILY RESIDENTIAL MUST COMPLY WITH AT LEAST 5 OF THE STANDARD AND DESIGN ELEMENTS. THIS DESIGN MEETS THE FOLLOWING DESIGN ELEMENTS:. FRONT AND REAR FACING MAIN GABLE TO HAVE DECORATIVE S.. MINIMUM 6" CORNER BOAR AT EXTERIOR CORNERS.. PORCH POST TO BE MINIMUM OF 8" SQUARE OR ROUND WITH DECORATIVE TRIM AT TOP AND BOTTOM.. A MINIMUM OF ONE PLANE BREAK ON AT LEAST TWO FACADES. PLANE BREAK MAY BE HORIZONTAL OR VERTICAL. 5. UPPER GARAGE DOOR PANEL WITH DIVIDED LIGHT PATTERN TOTAL SURFACE AREA BUILDING =, SF TOTAL STONE SURFACE BUILDING =,07 SF PERCENT STONE PROVIDED = 6% PERCENT STONE REQUIRED (THORNTON) = 5% MIN TOTAL GLAZING PROVIDED > SF FOR EACH STREET FACING FACADE TOTAL GLAZING REQUIRED (THORNTON) = SF MIN EACH STREET FACING FACADE COMP. ASPHALT SHINGLES (TYP) GABLE END PTD. ALUM. GUTTER (TYP) 6" CORNER BOARD (TYP) 8" LAP CEMENTITIOUS SIDING (TYP) MODEL 95 - APPLAUSE MODEL 95 - APPLAUSE (BUILDING TYPE ) GARAGE ELEVATION /6" = '-0" 0 ' 8' ' 09'- /8" CO-088 MANUF. STONE BAND (TYP) THIN MANUF. STONE SIDING (TYP) '-0" ELECTRICAL SERVICE PANEL " WATER 00'-0" (BUILDING TYPE ) ENTRY ELEVATION /6" = '-0" 0 ' 8' ' --6 COPYRIGHT 06 " GUTTER (TYP) " GUTTER (TYP) Revision 6--5 Revision -8-6 Revision '- /8" 09'- /8" '-0" 00'-0" 8'-0" HDR. HT. BLDG ELEVATIONS (BUILDING TYPE ) INSET ELEVATION (BUILDING TYPE ) INSET ELEVATION /6" = '-0" /6" = '-0" A5.

4 9.5' BUILDING ENVELOPE (SEE ELEVATION A5.) A5. '-0" (SEE ELEVATION A5.) A6. AREA INDICATES COMPLIANCE W/ IRC 0 R0.. EXCEPTION - IN LIEU OF PARAPET WALLS THE ROOF SHEATHING IS NOTED AS BEING FIRE RETARDANT TREATED WOOD FOR A MINIMUM OF FEET FROM THE PROPERTY LINE WHICH DOES NOT ALLOW FOR PENETRATIONS OF S AND INTAKES " % SLOPE, TYP., W/ " MIN. DIA. LEADER PER 0 INTERNATIONAL PLUMBING CODE SEC. 06 A5. UNIT 95 - APPLAUSE MINIMUM AREA AS PER IRC R806. REQUIRED ILATION = ATTIC AREA / SF / 00 = 7 SF EAVES UNIT 95 - APPLAUSE MINIMUM AREA AS PER IRC R806. REQUIRED ILATION = ATTIC AREA / SF / 00 = 7 SF EAVES /" / " ROOF TYPE: R /" / " UNIT 95 - APPLAUSE MINIMUM AREA AS PER IRC R806. REQUIRED ILATION = ATTIC AREA / SF / 00 = 7 SF EAVES UNIT 95 - APPLAUSE MINIMUM AREA AS PER IRC R806. REQUIRED ILATION = ATTIC AREA / SF / 00 = 7 SF EAVES A5. " % SLOPE, TYP., W/ " MIN. DIA. LEADER PER 0 INTERNATIONAL PLUMBING CODE SEC ' BUILDING ENVELOPE CO-088 A5. A COPYRIGHT 06 Revision -8-6 Revision --6 (SEE ELEVATION A5.) A5. '-0" (SEE ELEVATION A5.) ROOF PLAN (BUILDING ) /6" = '-0" 0 ' 8' ' BLDG ROOF PLAN A5.

5 5 A7. TRUSSES RE: STRUCTURE A TYPICAL ROOF SYSTEM, PROVIDE ROOF S AND/OR SOFFIT S *NOTE: SEE STRUCTURAL DRAWINGS TO VERIFY TRUSS DIRECTION 09'- /8" GREATROOM KITCHEN HALL 5 A7.0 TYPICAL INTERIOR WALL: x STU W/ /" GYP BD ON BOTH SIDES (SEE PLAN FOR X6 WALL LOCATIONS) MASTER BEDROOM MASTER BEDROOM 5 A7.0 HALL KITCHEN GREAT ROOM TYPICAL EXTERIOR WALL: EXT. WALL MATERIAL OVER SHEATHING OVER x6 STU W/ BATT INSULATION W/ /" GYP BD INSIDE 00'-0" FLOOR JOIST RE: STRUCTURE STEEL BEAM RE: STRUCTURE ILATE CRAWL SPACE PER SOILS REPORT COLUMN RE: STRUCTURE A6. FOUNDATION RE: STRUCTURE PROVIDE MIN. 0 MIL VAPOR RETARDER OR VAPOR BARRIER ON EXPOSED SOIL INSTALL AS PER GEOTECH REPORT TYPICAL FLOOR SYSTEM: /" OSB GLUED & NAILED OVER FLOOR JOISTS, RE:STRUCTURAL CRAWLSPACE AS REQ'D. MECH CONTRACTOR TO CONFIRM ILATION REQUIREMENTS. FULL SECTION (BUILDING ) /" = '-0" A7. R-9 INSULATION AT FOUNDATION PERIMETER PROVIDE PERIMETER DRAIN (DRAIN PER SOILS REPORT RECOMENDATION) DRAIN TO DAYLIGHT OR SUMP A6. TRUSSES RE: STRUCTURE TYPICAL ROOF SYSTEM, PROVIDE ROOF S AND/OR SOFFIT S CO A7. *NOTE: SEE STRUCTURAL DRAWINGS TO VERIFY TRUSS DIRECTION 09'- /8" DINING KITCHEN HALL MASTER BEDROOM TYPICAL INTERIOR WALL: x STU W/ /" GYP BD ON BOTH SIDES (SEE PLAN FOR X6 WALL LOCATIONS) MASTER BEDROOM HALL KITCHEN DINING TYPICAL EXTERIOR WALL: EXT. WALL MATERIAL OVER SHEATHING OVER x6 STU W/ BATT INSULATION W/ /" GYP BD INSIDE --6 COPYRIGHT 06 TYPICAL FLOOR SYSTEM: /" OSB GLUED & NAILED OVER FLOOR JOISTS, RE:STRUCTURAL A7. Revision -8-6 Revision '-0" STEEL BEAM RE: STRUCTURE COLUMN RE: STRUCTURE PROVIDE MIN. 0 MIL VAPOR RETARDER OR VAPOR BARRIER ON EXPOSED SOIL INSTALL AS PER GEOTECH REPORT FOUNDATION RE: STRUCTURE FOUNDATION RE: STRUCTURE PROVIDE MIN. 0 MIL VAPOR RETARDER OR VAPOR BARRIER ON EXPOSED SOIL INSTALL AS PER GEOTECH REPORT CRAWLSPACE AS REQ'D. MECH CONTRACTOR TO CONFIRM ILATION REQUIREMENTS. R-9 INSULATION AT FOUNDATION PERIMETER PROVIDE PERIMETER DRAIN (DRAIN PER SOILS REPORT RECOMENDATION) DRAIN TO DAYLIGHT OR SUMP FULL SECTION (BUILDING ) /" = '-0" BUILDING SECTIONS

6 TYPICAL ROOF SYSTEM, PROVIDE ROOF S AND/OR SOFFIT S, PER PLANS A6. CO-088 *NOTE: SEE STRUCTURAL DRAWINGS TO VERIFY TRUSS DIRECTION TRUSSES RE: STRUCTURE 09'- /8" 9 A7. 5/8" TYPE 'X' GYP BD. ON GARAGE CEILING AND WALLS --6 COPYRIGHT 06 00'-0" TYPICAL GARAGE FLOOR: CONCRETE SLAB ON GRADE OVER CONTINUOUS VAPOR BARRIER - SLOPE %-% (MIN.) TO OVERHEAD DOOR, RE: STRUCTURAL WARP CONCRETE AT DOOR TO ENSURE NO CHANGE IN LEVEL WARP CONCRETE AT DOOR TO ENSURE NO CHANGE IN LEVEL FOUNDATION RE: STRUCTURE LINE OF VAPOR BARRIER, TYP. PROVIDE PERIMETER DRAIN (DRAIN PER SOILS REPORT RECOMENDATION) DRAIN TO DAYLIGHT OR SUMP Revision -8-6 Revision Author Checker GARAGE SECTION (TYP)) /" = '-0" BUILDING SECTIONS A6.