HOUSE DETAILS House Plan with dimensions (From Appraisers Website)

Size: px
Start display at page:

Download "HOUSE DETAILS House Plan with dimensions (From Appraisers Website)"

Transcription

1 Questionnaire for FBC, Field study of Sealed Attics for Florida Home Identification: House 1: Standing Seal Metal roof with ocspf sealed attic Interviewers: Dr. William A. Miller, Oak Ridge National Laboratory, Mitali Talele, University of Florida Graduate student in Structural Engineering Date: 25 May 2016 HOUSE DETAILS House Plan with dimensions (From Appraisers Website) of Sealed Attics conducted for the State of Florida 1

2 Elevation 1 (Wall 1) Openings Wall 1 W1 W2 MD GD W3 Height Width Description Photos Associated E1-W E1-W E1-MD E1-GD of Sealed Attics conducted for the State of Florida 2

3 Elevation 2 (Wall 2) Openings Wall 2 W1 D1 W2 D2 Height Width Description Photos associated E2-W E2-D E2-W E2-D2 of Sealed Attics conducted for the State of Florida 3

4 Elevation 3 (Wall 3) Openings Wall 3 D1 D2 D3 Height Width Description Photos Associated E3-D E3-D E3-D3 of Sealed Attics conducted for the State of Florida 4

5 Elevation 4 (Wall 4) (Inter distances not available as area was not accessible) Openings Wall 4 W1 D1 W2 Height Width Description Photos Associated E4-W E4-D E4-W2 of Sealed Attics conducted for the State of Florida 5

6 Sketch of cross-section of roof deck including dimensions (Slope of roof: 6/12 at ridge, 3/12 at perimeter) Section through the roof rafter showing insulation details (Truss Spacing: 2 ft.) (Thk. of foam: 6.5 in.) N/A of Sealed Attics conducted for the State of Florida 6

7 Plan showing ducts and location of Registers and Returns for Air Duct system Date: 25 May 2016 N/A Details of the Ducting System Sr. No. Duct Pipe No. Length Size of the duct Not Accessible of Sealed Attics conducted for the State of Florida 7

8 Sr. No. Questions Response Q1) Date Built 1962 Information from Homeowners ROOF DETAILS Q2) Roof Cover 1) Asphalt Shingles 2) Metal (Forced Green) 2) Concrete S- Tile 4) Other (describe below) Q3) Roof insulation location 1) Underside of roof sheathing 2) At Ceiling 3) Both locations: Q4) Dominant roof structure 1) Gable 2) Hip 3) Combination Q5) Roof sheathing for the structure 1) OSB 2) Plywood 3) Other Q6) Slope of the roof 1) 3/12 at the perimeter 2) 6/12 at the transition FOAM INSULATION DETAILS Q7) What was the installation date of the foam and what was the cost of installation? Year: 2010 Cost: 3000$ Q8) Who is the manufacturer and the installer of the spray foam insulation? Manufacturer: Icynene Installer: Jensen Insulation Q9) Was the spray foam installed prior to owning the house or was the foam installed later? Later (Approximately around 2010) of Sealed Attics conducted for the State of Florida 8

9 Q10) If installed later, what is the homeowner s perception of the impact of Open/Closed SPF on the comfort level of the house? The time required for cooling of the house is less as compared to the time when attic was vented. Q11) What is the homeowner s perception of the impact of SPF on the energy costs of the home? Energy Costs reduced. Q12) Were there any signs of moisture damage seen by the homeowner? If so, when, why, and where was the damage seen and what were the steps taken to overcome the problem? None. CONDITIONED SPACE DETAILS Q13) Is there any unconditioned space in the house. If the attic is partially unvented, what are the respective areas? Area of the house details Area of the house Area of the conditioned space Area of unconditioned space Measured values 2967 sq. ft sq. ft. 924 sq. ft. (Garage: 572 sq. ft.) of Sealed Attics conducted for the State of Florida 9

10 HVAC SYSTEM DETAILS Q14) What is the HVAC system installed in the house, what is its size and how long is the HVAC System being installed? Details of the system Response recorded Lennox (2 systems in total are installed) HVAC system installed Product No: XC14-D SN 5812E03935 Size of System 2 tons each Product No.: 5813M02334 Installation done by Homeowner originally (1997) Modified in the years 2004 and 2006 Other Details of the system System has only Air conditioning units, No Heating units. For heating purposes, heating coils are present. SEEIC 16 Variable speeds blown. DUCT DETAILS Details required Manufacturer of the ducting system Installation done by Response recorded Underwriters Laboratories N/A Year of Installation 1997 Modifications in the system Replacement was done by installing HVAC System. installed if any Q15) What are the size of the ducts in the house? Details Required Response Recorded Size of the ducts Main Duct: 24 in. outer diameter Branched Ducts: 8 in. outer diameter One Branch: 6 in. for the register of Sealed Attics conducted for the State of Florida 10

11 OVERALL OPINION OF EXPERIENCE OF THE HOMEOWNER WITH SEALED ATTICS The homeowner was concerned about the wood rotting in the truss around the foam. His opinion was that the temperature difference between the outside temperature and inside of the house would create a dew point in the plywood. As the moisture would not pass through the soffit vents as they are closed, are they going to hold moisture finally giving a chance for the wood to rot. of Sealed Attics conducted for the State of Florida 11