Evidence of Performance. Class 4. Class E900. Class C3 / B3. Test Report No PR02. DOMIS d.o.o. Miokovci bb Cacak Serbia

Size: px
Start display at page:

Download "Evidence of Performance. Class 4. Class E900. Class C3 / B3. Test Report No PR02. DOMIS d.o.o. Miokovci bb Cacak Serbia"

Transcription

1 Evidence of Performance Test Report No PR02 (PB-A01-02-en-01) Client Product Designation Performance-relevant product details Overall dimensions (W x H) Special features DOMIS d.o.o. Miokovci bb Cacak Serbia Double vent window with vertical mullion System designation: Wood-Aluminium DOMIS KONTINENTAL Material: Wood-Aluminium 2,300 mm x 1,680 mm Basis EN :2006+A1:2010 Test standard/s: EN 1026: EN 1027: EN 12211: Correspond/s to the national standard/s (e.g. DIN EN) Representation Results Air permeability according to EN 12207: ift Rosenheim Class 4 Watertightness according to EN 12208: Class E900 Resistance to wind load according to EN 12210: /AC: Class C3 / B3 Jörn Peter Lass, Dipl.-Ing. (FH) Head of Testing Department Building Components Robert Kolacny, Dipl.-Ing. (FH) Deputy Head of Testing Department Building Components Instructions for use The results obtained can be used by the manufacturer as the basis for the manufacturer ITT test report summary. Observe the specifications set out by the applicable product standard. Validity The data and results refer solely to the tested and described specimen. Classification remains valid as long as the product and the above basis remain unchanged. The results can be extrapolated under the manufacturer's own liability subject to observance of the relevant specifications set out by the applicable product standard. This test/evaluation does not allow any statement to be made on any further characteristics regarding performance and quality of the construction presented; in particular the effects of weathering and ageing were not taken into account. Notes on publication The ift-guidance Sheet "Advertising with ift test documents" applies. The cover sheet can be used as an abstract. The report contains a total of 27 pages.

2 Evidence of Performance Page 2 of 14 1 Object 1.1 Description of test specimen Product Double vent window with vertical mullion Manufacturer GTPD DOMIS d.o.o., Čačak, Serbia Date of manufacture System Wood-Aluminium DOMIS KONTINENTAL Type of opening / Opening directions Right casement - Tilt, DIN right, inward opening Left casement - Tilt and turn, DIN left, inward opening Frame material Wood-Aluminium Overall frame dimensions (W x H) 2300 mm x 1680 mm Overall casement dimensions 2192 mm x 1600 mm (W x H) Left and right casement: 1096 mm x 1600 mm Casement weight Left - 38,5 kg; Right - 38,3 kg Three-layer spruce elements 66 x 56 mm, Frame member further details are given in drawings Mitred cut, glued, fixed with HOFFMANN-Key and screwed with 1 Frame connection screw 5 x 80 mm Aluminium profile Nissal M4707 and M5252, mitre-cut, glued and sealed Mechanical L-connection using L-cleats, aluminium ŠP 1514, ABS LS16 and LS38, 58 x Poliamid 6 spacer LC4 with screws 3,5 x 35 mm Additional profile / Aluminium profile Brams d.o.o. LA 142, butt-cut, Frame connection 16 x Poliamid 6 spacer LC4 with screws 3,5 x 35 mm Aluminium profile Nissal M4575, butt-cut, 10 x Poliamid 6 spacer LC4 with screws 3,5 x 35 mm Mullion profile - Three-layer spruce elements 80 x 56 mm, tenon and mortice T-joint with 1 screw 5 x 80 mm Three-layer spruce elements 78 x 57 mm, Casement member further details are given in drawings Mitred cut, glued, fixed with HOFFMANN-Key and scewed with 1 Frame connection screw 5 x 60 mm Additional profile / Frame connection Rebate design Rebate drainage Rebate seal External Material Manufacturer Article number Eckausbildung Corner configuration Aluminium profile Nissal M4706, mitre-cut, glued and sealed Mechanical L-connection using L-cleats, aluminium ŠP 1514, 29 x Poliamid 6 spacer LC4 with screws 3,5 x 35 mm Aluminium profile M5252, 5 slots 7,5 mm x 43,5 mm inside to outside, side slots 190 and 210 mm from the external edge of the frame member, distance in between slots 355, 360, 370 and 595 mm Sealing material TPE Sava Kranj, Slovenia P6 mitre-cut and bonded; mullion profile - butt-jointed

3 Evidence of Performance Page 3 of 14 Centre Material Sealing material - EPDM Manufacturer Sava Kranj, Slovenia Article number P6 Corner configuration continuous, notched in corners, at top butt-jointed at centre Internal Material Sealing material TPE Manufacturer Sava Kranj, Slovenia Article number P6 Corner configuration mitre-cut Pressure equalisation Without pressure equalisation. Infill Insulating glass unit, configuration 4 / 16 / 4 Installation of infills Glazing gasket External Material Sealing material - EPDM Manufacturer Sava Kranj, Slovenia Article number P6 Corner configuration continuous, notched in corners, at top butt-jointed at centre and bonded Internal Material Sealing material TPE Manufacturer Sava Kranj, Slovenia Article number E6 Corner configuration mitre-cut Vapour pressure equalisation 3 mm gap between additional aluminium profile and casement member Hardware Type / Manufacturer Left casement - Tilt and turn hardware, ROTO Compact S Right casement Turn hardware, ROTO Compact S 1 Tilt mechanism pivot 2 Corner pivot Hinges / Bearings 2 Turn mechanism pivot Left casement: 1 tilt mechanism pivot, 2 corner pivot Right casement: 2 Turn mechanism pivot, 1 corner pivot at bottom 2, at top 4, on hinge side 1, on lock side 4 Number of lockings Left casement: at bottom 1, at top 2, on hinge side 1, on lock side 2 Right casement: at bottom 1, at top 2, on lock side 2 max. locking distance 950 mm Position of lockings neutral The description is based on information provided by the client and inspection of the test specimen at the ift (item designations / numbers as well as material specifications were provided by the client unless stated "ift-checked ). Test specimen representations are documented in the Annex "Representation of product/test specimen. The design details were examined solely on the basis of the characteristics / performance to be classified. The drawings are based on unchanged documentation provided by the client unless stated otherwise. The photographs were taken by the ift Rosenheim unless stated otherwise.

4 Evidence of Performance Page 4 of Sampling The below sampling data were provided to the ift: Sampling by: GTPD DOMIS d.o.o. Date: Verification: ift-pk-number: A sampling report has been provided to the ift PK03 2 Procedure 2.1 Basis*) referring to methods Testing EN 1026: Windows and doors - Air permeability - Test method EN 1027: Windows and doors - Watertightness - Test method EN 12211: Windows and doors - Resistance to wind load - Test method Classification / Evaluation EN 12207: Windows and doors - Air permeability - Classification EN 12208: Windows and doors - Watertightness - Classification EN 12210: /AC: Windows and doors - Resistance to wind load - Classification *) and the equivalent national versions, e.g. DIN EN

5 Evidence of Performance Page 5 of Brief description of procedure Air permeability - EN 1026 Air permeability is tested in accordance with EN 1026 and conducted in steps at negative pressure and positive pressure up to the maximum test pressure difference. Leakages of the test set-up are made visible using artificially generated fog and sealed using permanently resilient sealant. The test specimen is exposed to three pressure pulses pmax + 10 % or at least 500 Pa. This is followed by measurement of air permeability for the respective pressure steps. + Pa 3 if required 0 1 Time (sec.) - Pa opening and closing Illustration Test sequence for air permeability

6 Evidence of Performance Page 6 of 14 Resistance to wind load - Deflection and alternating negative/positive pressures - EN Resistance to wind load is tested in accordance with EN and conducted in steps at negative pressure and positive pressure up to the test pressure p 1. The test specimen is exposed to three pressure pulses p %. This is followed by determination of the frontal deflection of test specimen for each pressure step when exposed to positive test pressure p 1 and negative test pressure p 1. Then the test specimen is subjected to 50 cycles including negative and positive pressures of ± p 2 = p 1-50 %. Positive pressure P 1+10% 30±10 s 50 Cycles P 1 7±3 s P 2 60±5 s 0 -P 2 Stepwise or continuous increase in pressure, max. 100 Pa/s 7±3 s Time -P 1 P 1+10% 30±10 s 7±3 s Negative pressure Illustration Test sequence for resistance to wind load

7 Evidence of Performance Page 7 of 14 Air permeability Repeat test - EN 1026 Following resistance to wind load test for p 1 (deflection) and p 2 (alternating positive/negative pressure), air permeability must not exceed by more than 20% the upper limit of the specified class as set out by EN Watertightness - EN 1027 Watertightness is tested in accordance with EN 1027 up to the maximum test pressure difference. The external face of the test specimen is subjected to constant spraying of water by an upper row of nozzles at a flow rate of approx. 2 l/min per nozzle while increments of positive test pressure are applied at regular intervals. For test specimen exceeding 2.50 m in overall height, additional rows of nozzles are fixed at vertical intervals at 1.5 m below the top nozzle line. The water flow rate of the additional nozzle rows is approx. 1 l/min per nozzle. P ( Pa ) Illustration Test sequence for watertightness Time (min)

8 Evidence of Performance Page 8 of 14 Resistance to wind load Safety test - EN 1211 The wind resistance test (safety test) is conducted at negative pressure and positive pressure in accordance with EN up to test pressure p 3 = p %. Positive pressure 7±3 s P 3 7±3 s 7±3 s 0 Time -P 3 Negative pressure Illustration Test sequence for safety test

9 Evidence of Performance Page 9 of 14 3 Detailed results

10 Evidence of Performance Page 10 of 14

11 Evidence of Performance Page 11 of 14

12 Evidence of Performance Page 12 of 14

13 Evidence of Performance Page 13 of 14

14 Evidence of Performance Page 14 of 14

15 Annex 1: Representation of product/test specimen Page 1 of 4 Evidence of Performance Fig. Drawing of test specimen

16 Annex 1: Representation of product/test specimen Page 2 of 4 Evidence of Performance Fig. Vertical section

17 Annex 1: Representation of product/test specimen Page 3 of 4 Evidence of Performance Fig. Horizontal section

18 Annex 1: Representation of product/test specimen Page 4 of 4 Evidence of Performance Fig. Horizontal section

19 Annex 2: Page 1 of 9 Evidence of Performance View of test specimen on window test rig Window closed View of test specimen on window test rig Window open Test setup measurement of deflection 1 Rebate drainage 2 Rebate drainage 3 Rebate drainage

20 Annex 2: Page 2 of 9 Evidence of Performance 4 Rebate drainage 5 Rebate drainage 6 Rebate drainage 7 Rebate drainage External rebate seal, corner configuration Mullion profile External rebate seal, corner configuration Additional profile, Aluminium profile Frame member

21 Annex 2: Page 3 of 9 Evidence of Performance External rebate seal Centre seal, corner configuration Centre rebate seal, sealant joint Centre rebate seal Internal rebate seal, corner configuration Internal rebate seal

22 Annex 2: Page 4 of 9 Evidence of Performance External glazing seal, corner configuration External glazing seal, sealant joint External glazing seal Internal glazing seal, corner configuration Internal glazing seal View of horizontal glazing rebate

23 Annex 2: Page 5 of 9 Evidence of Performance 1 Vapour pressure equalisation 2 Vapour pressure equalisation 1 Additional profile, Aluminium profile Frame member, corner configuration 2 Additional profile, Aluminium profile Frame member, corner configuration 3 Additional profile, Aluminium profile Frame member, corner configuration Additional profile, Aluminium profile Frame member, L-cleats, aluminium

24 Annex 2: Page 6 of 9 Evidence of Performance 1 Additional profile, Aluminium profile Frame member, L-cleats, ABS 2 Additional profile, Aluminium profile Frame member, L-cleats, ABS 1 Additional profile, Aluminium profile Casement member, corner configuration 2 Additional profile, Aluminium profile Casement member, corner configuration PVC spacer, frame and casement member Additional profile, Aluminium profile Frame member

25 Annex 2: Page 7 of 9 Evidence of Performance Additional profile, Aluminium profile Mullion profile Mullion, corner configuration Foto Flügelrahmen, Eckausbildung Casement member, corner configuration Foto Blendrahmen, Eckausbildung Frame member, corner configuration Tilt mechanism pivot, internal view Tilt mechanism pivot, rebate view

26 Annex 2: Page 8 of 9 Evidence of Performance Corner pivot, internal view Corner pivot, rebate view Turn mechanism pivot 1, internal view Turn mechanism pivot 1, rebate view Turn mechanism pivot 2, internal view Turn mechanism pivot 2, rebate view

27 Annex 2: Page 9 of 9 Evidence of Performance 1 Locking situation, frame member / casement member 1 2 Locking situation, frame member / casement member 1 1 Locking situation, frame member / casement member 2 2 Locking situation, frame member / casement member 2