1 BUILDING CODE ANALYSIS (FORM F) PROJECT: Roof Recover Project at Jack A. Powers Building SUBMITTAL: [ ] SCHEMATIC [ ] DESIGN DEVELOPMENT [ X ] CONSTRUCTION DOCUMENT DATE: /9/08 CODE & EDITION: 05 IBC & 009 IECC GUIDE EDITION: 0 PLANNING & CONSTRUCTION GUIDE BASIC BUILDING CODE INFORMATION CONSTRUCTION CLASSIFICATION TYPE (BC 60) OCCUPANCY GROUP (indicate all) (IBC 0) (Note IBC 506.5) OCCUPANCY GROUP (indicate most restrictive) (IBC Table 50) Does building require Incidental Use Area Separation? (IBC ) Does building have Accessory Occupancy (ies)? What percent of story is Accessory Occupancy? (IBC 508.) Mixed Occupancy (IBC 508) Non separated (IBC 508.) Separated (IBC 508.) (IBC 506.5) OTHER FIRE PROTECTION SYSTEMS, DEVICES or FEATURES If the building has any special or notable fire protection or safety feature or hazard, the designers should list them here, describe the performance characteristics and refer to locations in construction documents (e.g. fire extinguishers, smoke-evacuation/control/compartments. Note IBC...) Roof Construction including supporting beams & joists (IBC Table 60) WIND LOADS FIRE RESISTANCE RATING BUILDING ELEMENTS As Required, Hrs As Designed, Hrs Testing Agency & Design No.(UL, FM, etc) Roof Assembly Key Code STRUCTURAL DESIGN INFORMATION, BUILDING Analysis Procedure (ASCE 7-0 or IBC 609.6) Basic Wind Speed, MPS ( sec gust) Fig. 6.5-B ASCE 7-0 Exposure Category Internal Pressure Coefficient (ASCE 7-0) External Pressure Coefficient (ASCE 7-0) ENERGY INFORMATION INSULATION RO AREAS A&A TYPE II-A B B SF % N/A RO AREAS A&A HR HR UL P0 (RAs A&A) P77 (RA ) ASCE 7-0 VS= 0 CAT. B GCpi=±0.8 FIELD= -.0 GCp= PERIMETER= -.8 CORNER= -.8 Roof Continuous 0 R PROJECT DATA A.PROJECT DESIGNED IN ACCORDANCE WITH:. INTERNATIONAL BUILDING CODE - 05 EDITION.INTERNATIONAL PLUMBING CODE - 05 EDITION.INTERNATIONAL FIRE CODE - 05 EDITION.INTERNATIONAL EXISTING BUILDING CODE - 05 EDITION 5.INTERNATIONAL ENERGY CONSERVATION CODE EDITION 6.NATIONAL FIRE PROTECTION ASSOCIATION 0-0 EDITION B.BASIC REVIEW INFORMATION. EXISTING BUILDING IS A STORY REINFORCED CONCRETE MASONRY UNIT (CMU) LOAD BEARING WALL CONSTRUCTION WITH STEEL BAR JOISTS AND METAL RO DECK.. AREA AFFECTED RO (RA): 9,00 SF a. RA :,86 SF b. RA : 6, SF. RO HEIGHT ABOVE GRADE (ALL ARE APPROXIMATE): a. RA A: ' b. RA A: '. PRIMARY OCCUPANCY CLASS: GROUP B BUSINESS 5. CLASS A RO COVERING C. PROJECT IN FIRE DISTRICT: YES RA # K R D D D LEGEND = AREA TO BE REPLACED = AREA NOT IN CONTRACT = RO AREA LABEL DRAWING INDEX KEY PLAN, DRAWING INDEX & SITE VICINITY MAP RO PLAN REROING PROJECT AT JACK A. SPARTANBURG COMMUNITY COLLEGE 07 COMMUNITY COLLEGE DRIVE 90 EJ EJ EJ EJ EJ EJ RA A EJ EJ EJ EJ EJ EJ RA A TITLE: REVISION DATE APPROVED Key Plan 0/0/8 WBS PROJECT DESCRIPTION: 57 Dreher Shoals Road, Suite 6 Irmo, South Carolina 906 Phone: (80) Fax: (80) REROING PROJECT AT JAMES A. STATE PROJECT No. H59-N00-PD D. STRUCTURAL INFORMATION:. DESIGN LOADS: a. ORIGINAL DEAD LOAD INCLUDED AGGREGATE BUILT UP RO, METAL RO DECK. ESTIMATED WEIGHT: 5 lbs/sf b. PROPOSED DEAD LOAD INCLUDING PLY FLEXIBLE MEMBRANE & RIGID/TAPERED INSULATION OVER EXISTING METAL RO DECK. DESIGN WEIGHT: 0 lbs/sf c. NET DEAD LOAD REDUCTION 5 lbs/sf JACK A. ("A" WING) KEY PLAN RA PF DATE: /9/8 SITE SITE VICINITY MAP P. DAN HULL BUILDING (CAMPUS POLICE) KEY PLAN K

2 PROVIDE TAPERED WOOD-FIBER EDGE AT PERIMETER TO ACHIEVE CONSTANT METAL EDGE HEIGHT () SIM. D TFS D TFS S S S TFS TFS PP EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EF 5 D EF PP D ELH D D RA A EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ EJ D RA A TFS /":" /8":" TFS D TFS TFS SLOPE TRANSITION LH PP RA # S TFS = AREA TO REPLACE = AREA NOT IN CONTRACT = RO AREA DESIGNATION = SLOPE IN STRUCTURE = SANITARY VENT = RO DRAIN = OVERFLOW SCUPPER = LOUVER HOUSING = PIPE PENETRATION HOUSING = NEW OVERFLOW NOZZLE = NEW OVERFLOW DRAIN = NEW THROUGH-FASCIA OVERFLOW SCUPPER PROVIDE TAPERED WOOD-FIBER EDGE AT PERIMETER TO ACHIEVE CONSTANT METAL EDGE HEIGHT () S S TFS S LEGEND D D D TFS S ELH TFS D SIM. TITLE: REVISION DATE APPROVED Roof Plan 0/0/8 WBS PROJECT DESCRIPTION: 57 Dreher Shoals Road, Suite 6 Irmo, South Carolina 906 Phone: (80) Fax: (80) REROING PROJECT AT JAMES A. STATE PROJECT No. H59-N00-PD PF DATE: /9/8 XC AS TFS S S TFS S S TFS S TFS S D R

3 EXISTING PIPE PENETRATION NEW LIQUID APPLIED FLASHING NEW BASE AND TAPERED INSULATION MECHANICALLY FASTENED TO EXISTING METAL DECK '-0" NEW SEALANT NEW TAPERED EDGE STRIP EXISTING RO DRAIN NEW WATER CUT-F MASTIC NEW FSM TARGET (MECHANICALLY ATTACHED) TYPICAL RO DRAIN PROVIDE ' SUMP WHERE SHOWN ON RO PLANS 8" MIN. 8" MIN. SEAL CONTINUOUS HEAT WELDED SEAM NEW FSM BASE FLASHING NEW FLEXIBLE MEMBRANE ASSEMBLY CLOSURE DETAIL METAL SCREW NEW TAPERED EDGE STRIP MECHANICALLY FASTENED TO EXISTING METAL DECK TYPICAL LONG WALL FASCIA HEAT WELD (" MIN.) EXISTING WOOD BLOCKING NEW FSM BASE FLASHING AND FIELD MEMBRANE EXHAUST FAN CURB NEW METAL COUNTER FLASHING NEW BASE FLASHING NEW INSULATION " NEW METAL GRAVEL STOP FASCIA WITH LOCKING CLEAT /" TITLE: REVISION DATE APPROVED Details 0/0/8 WBS PROJECT DESCRIPTION: 57 Dreher Shoals Road, Suite 6 Irmo, South Carolina 906 Phone: (80) Fax: (80) REROING PROJECT AT JAMES A. STATE PROJECT No. H59-N00-PD EXISTING METAL DECKING 5 MECHANICAL EXHAUST FAN CURB PIPE PENETRATION TO BE USED AT SANITARY VENTS, EQUIPMENT AND PIPING SUPPORTS PF DATE: /9/8 RO PENETRATION FLASHING/FLANGED PIPE HOUSING D

4 EXISTING BUILT-UP ROING EXISTING INSULATION RA NIC NEW INDUCTION WELD PLATES TO MATCH EXISTING NEW xx ANGLES NEW CLIP ANGLES ABANDONED LOUVER HOUSING (WITH SLOPE) NEW TPO-COATED METAL EDGE TRIM AND FASTENERS REMOVED IN ADDENDUM NEW FLEXIBLE STRIPPING PLY NEW CUT EDGE SEALANT EXISTING WOOD BLOCKING REMOVE EXISTING ANGLES IN CORNERS NEW TPO MEMBRANE NEW CLOSED CELL FOAM CORE RA A NEW EXPANSION JOINT FLASHING NEW TAPERED EDGE EXISTING ABANDONED LOUVER HOUSING MAX. '-0" O.C. NEW RIGID INSULATION NEW xx ANGLE FLASHING AT LOUVER HOUSING (CROSS SLOPE) RA A NEW EXPANSION JOINT FLASHING NEW TAPERED EDGE EXISTING INSULATION REMOVED IN ADDENDUM NEW PERIMETER FASTENER RA A TITLE: REVISION DATE APPROVED Details 0/0/8 WBS PROJECT DESCRIPTION: 57 Dreher Shoals Road, Suite 6 Irmo, South Carolina 906 Phone: (80) Fax: (80) REROING PROJECT AT JAMES A. STATE PROJECT No. H59-N00-PD PF DATE: /9/8 EXPANSION JOINT EXPANSION JOINT D

5 NEW GUTTER, BRACKET, AND SPACER NEW DOWNSPOUT AND BRACKET HEAT WELD (" MIN.) " NEW METAL "J" TRIM SIM. a " 6" 6" D DS NEW FLEXIBLE MEMBRANE ADHERED TO INSULATION " (FIELD VERIFY) DOWNSPOUT EXISTING CONCRETE DECK EXISTING STRUCTURE DS DS DS DS EJ EJ P. DAN HULL BUILDING RO PLAN (NORTH END) ALTERNATE No. EXISTING EDGE METAL EXISTING COUNTERFLASHING NEW COUNTERFLASHING WITH LOCKING CLEAT NEW METAL HAT CHANNEL NEW METAL FASCIA NEW METAL SILL TRIM NEW METAL RECEIVER NEW TERMINATION BAR NEW COUNTERFLASHING 8" MIN. NEW TERMINATION BAR SECTION AT HULL BUILDING ALTERNATE No. D DS PF DATE: /9/8 D TITLE: REVISION DATE APPROVED Alternate No. RA and Details ALT # designated /0/8 WBS PROJECT DESCRIPTION: REROING PROJECT AT JAMES A. STATE PROJECT No. H59-N00-PD 57 Dreher Shoals Road, Suite 6 Irmo, South Carolina 906 Phone: (80) Fax: (80)

6 EXISTING LOUVER HOUSING FRAME NEW METAL COUNTERFLASHING NEW BASE FLASHING NEW INDUCTION WELD PLATES TO MATCH EXISTING NEW xx ANGLES NEW CLIP ANGLES EXISTING ANGLE IN CORNERS FLASHING AT LOUVER HOUSING (WITH SLOPE) ADDED IN ADDENDUM " /8" MECHANICALLY FASTENED TO EXISTING METAL DECK NEW LAG FASTENERS HEAT WELD (" MIN.) NEW METAL COUNTERFLASHING NEW BASE FLASHING NEW INDUCTION WELD PLATES NEW METAL GRAVEL STOP FASCIA WITH LOCKING CLEAT EXISTING LOUVER HOUSING FRAME NEW xx ANGLE NEW RIGID INSULATION FLASHING AT LOUVER HOUSING (CROSS SLOPE) ADDED IN ADDENDUM " /" MEMBRANE BEYOND MECHANICALLY FASTENED TO EXISTING METAL DECK HEAT WELD (" MIN.) EXISTING WOOD BLOCKING NEW METAL FLASHING NEW LOCKING CLEAT TITLE: REVISION DATE APPROVED Alternate No. RA and Details ALT # designated /0/8 WBS PROJECT DESCRIPTION: 57 Dreher Shoals Road, Suite 6 Irmo, South Carolina 906 Phone: (80) Fax: (80) REROING PROJECT AT JAMES A. STATE PROJECT No. H59-N00-PD 0/0/8 WBS PF DATE: /9/8 FASCIA AT RAa (EAST SIDE) ADDED IN ADDENDUM THROUGH-FASCIA OVERFLOW SCUPPER ADDED IN ADDENDUM