FOR TENDER PURPOSE ONLY

Size: px
Start display at page:

Download "FOR TENDER PURPOSE ONLY"

Transcription

1 POST INSULATORS Quarter Quarter Office Office Guest House Canteen 132kV Cable Termination Yard kV Cable Termination Yard NOT IN SCOPE 220/132 KV Tower Guard room Store room Control room 400kV GIS LAYOUT OF HETAUDA SUBSTATION ELECTRICAL LAYOUT PLAN DRAWING NO. NEA-HDI-H-E-LY-01 OF kV SWITCHYARD AREA 220kV SWITCHYARD AREA N 11kV Line Take off Tower/Beam

2 400kV GIS LAYOUT OF INARUWA SUBSTATION ELECTRICAL LAYOUT PLAN DRAWING NO. NEA-HDI-I-E-LY-01 OF 01

3 400 KV D/C QUAD MOOSE ACSR LINE FROM DHALKEBAR NEPAL 400 KV D/C QUAD MOOSE ACSR LINE FROM NAUBISE NEPAL 400 KV D/C FUTURE LINE 400/220 KV ICT BAY Future 400/220 KV ICT BAY HETAUDA 400/220KV GIS SUBSTATION SLD SINGLE LINE DIAGRAM DRAWING NO. NEA-HDI-H-SLD-01 OF 01

4 400 KV D/C QUAD MOOSE ACSR LINE FROM DHALKEBAR NEPAL 400 KV D/C FUTURE LINE 400 KV D/C FUTURE LINE INARUWA 400/220KV GIS SUBSTATION SLD SINGLE LINE DIAGRAM DRAWING NO. NEA-HDI-I-SLD-01 OF 01

5 DETAIL'A' 'A' STANDARD DETAIL FOR SWITCHYARD CHAIN LINK FENCING NEA-HDI-H/I -FEN-01 OF 01

6 NOTES 1. THIS DRAWINGS SHOWS A TYPICAL LAYOUT OF 400/220 KV GIS SUBSTATION. THE BIDDER SHALL SUBMIT THE LAYOUT OF GIS BUILDING AS PER TECHNICAL SPECIFICATION AND THE SAME WOULD BE FINALIZED AFTER THE APPROVAL OF OWNER. 2. ALL DIMENSION ARE IN MM AND ELEVATION IN METERS 3. DRAWINGS IS NOT IN SCALE 4. THE REQUIREMENT OF THE PRE-ENGINEERED BUILDING IS AS PER TS AND BPS F.F.L M. LVL. 400KV GIS HALL MM THK. FINAL FINISH IN 1:4 CEMENT MORTAR F.G.L 0.00 M. LVL. 50 MM THK. P.C.C. IN 1:2:4 75MM THK. COMPACTED RUBBLE PACKING 1 3 SIDE WALL GL- L WELL COMPACTED EARTH GIS BUILDING GENRAL LAYOUT DRAWING NO: NEA-HDI-H/I -PEB-01 OF 01

7

8 `E' `E' (MIN.) 1100 (MAX.) (MIN.) 1100 (MAX.) P.C.C. 1:4:8 (TYP) P.C.C. 1:4:8 (TYP) SECTION 2-2 SECTION 2A-2A (TYP) `E' 800 (MAX.) 75X6 M.S. FLAT 50X50X6 CABLE SUPPORT ANGLE P.C.C. 1:4:8 (TYP) P.C.C. 1:4:8 (TYP) SECTION 4-4 SECTION X6 M.S FLAT INSERT TYP. 50X50X6 CLEAT TO BE WELDED EARTHING CONDUCTOR `E'(50X6 M.S. FLAT) 50X6 FLAT TO BE WELDED 50X50X6 CLEAT ANGLE TYP. L50X50X6 75X6 M.S FLAT INSERT CABLE TRENCH WALL TYPICAL CABLE SUPPORT PLAN CABLE TRAY SUPPORT FOR SECTION 2-2,2A-2A, 3-3 AND 4-4 CABLE TRENCHES DETAIL OF CABLE TRENCH SECTIONS NEA-HDI-H/I -CT-01 OF 05

9 C L OF LIFTING HOOK (TYP) TRENCH COVER SLAB C L OF LIFTING HOOK (TYP) SIDE WALL OF CABEL TRENCH DETAIL OF TRENCH COVER SLAB FOR SECTION (2-2,2A-2A) C L OF LIFTING HOOK (TYP) CABLE TRENCH WALL 8 M.S. ROD WELDED TO M/S 750 C/C C L OF LIFTING HOOK (TYP) SLEEVE (TYP.) 1050 FOR SECTION FOR SECTION M.S. ROD SIDE WALL OF CABEL TRENCH 75x6 M.S. FLAT DETAIL OF LIFTING HOOK DETAIL OF TRENCH COVER SLAB FOR SECTION (3-3),(4-4) TYPICAL DETIAL OF ANCHORING 75X6 M.S.FLAT CABLE TRENCHES DETAIL OF CABLE TRENCH SECTIONS NEA-HDI-H/I -CT-02 OF 05

10 175 C/C 175 C/C 200 C/C 175 C/C 175 C/C 200 C/C SECTION 2-2 SECTION 2A-2A SECTION 3-3 C L OF LIFTING HOOK (TYP) C L OF LIFTING HOOK (TYP) PLAN (DETAIL OF TRENCH COVER FOR SECTION A-A) (DETAIL OF TRENCH COVER FOR SECTION B-B,C-C & D-D ) SECTION X-X SECTION 4-4 SECTION Y-Y CABLE TRENCHES DETAIL OF CABLE TRENCH SECTIONS NEA-HDI-H/I -CT-03 OF 05

11 PRECAST R.C.C. COVER SLAB 2475X400X50 (TYP) L 50X50X5 E 5 NOS. PRECAST R.C.C. COVER SLAB 3450X400X50 THK. PRECAST R.C.C. COVER SLAB 975X400X50 50x50x5 (TYP.) TRENCH COVER (±) 0.00M FORMATION LEVEL C/C NOS. D E D CABLE TRENCH WALL 6 NOS 16 LUGS C/C (BOTH FACE BOTH WAYS) LIFTING HOOK TYPICAL DETAIL OF SLAB SUPPORT SLEEVE (TYP.) C/C (BOTH FACE BOTHWAYS) 10 M.S. ROD TOP PLAN OF SUMP PIT C/C DETAIL OF LIFTING HOOK C/C (TOP & BOTTOM) BOTH WAYS SECTION D-D 75 THK. P.C.C. 1:4:8 X DETAIL 'X' 170 C/C C L OF 250Ø HUME PIPE AND SUMP PIT C/C SECTION 3-3 C/C 8 3 NOS. 50x50x5 (TYP.) C/C SECTION E-E CABLE TRENCHES GA AND RC DETAIL OF SUMP PIT NEA-HDI-H/I -CT-04 OF 05

12 TOP OF ABUTMENT TOP OF ROAD TOP OF ABUTMENT TOP OF ROAD 150 O PVC PIPE FOR CONTROL CABLE 150 O PVC PIPE FOR OFC G.L. G.L. G.L. G.L. R.C.C. HUME PIPE CLASS NP-3 (TYP) R.C.C. HUME PIPE CLASS NP-3 (TYP) S EARTH FILLING S EARTH FILLING P.C.C. (1:2:4:) 75 THK P.C.C.(1:4:8) P.C.C. (1:2:4:) 75 THK P.C.C.(1:4:8) CABLE TRENCH SECTION A-A CROSSING ROAD CABLE TRENCH SECTION B-B CROSSING ROAD TOP OF ABUTMENT TOP OF ROAD 150 O PVC PIPE G.L. G.L. R.C.C. HUME PIPE CLASS NP-3 (TYP) S EARTH FILLING P.C.C. (1:2:4:) 75 THK P.C.C.(1:4:8) CABLE TRENCH SECTION C-C CROSSING ROAD BRICK MASONARY IN 1:6 CEMENT SAND MORTAR G.L. G.L. INVERT LVL. P.C.C. (1:4:8:) (TYP) P.C.C. (1:2:4) 150 THK P.C.C. LONGITUDUNAL SECTION THROUGH CABLE TRENCH CROSSING ROAD CABLE TRENCHES DETAIL OF CABLE TRENCH CROSSINGS NEA-HDI-H/I -CT-05 OF 05

13

14 Note: 1.All dimension of building are tentative,final dimension shall be decided by contractor and approved by employer. RCC CONTROL BUILDING GENERAL LAYOUT DRAWING NO: NEA-HDI-H-CR-01 OF 01

15 12MM THK. CEMENT PLASTER WITH NEAT CEMENT FINISH ENTIRE INNER SURFACE AND TOP OF DRAIN F.G.L BRICK WORK WITH CM 1:6 25MM THK. P.C.C 1:2:4 75MM THK. P.C.C 1:4:8 X X 500 (MAX) SECTION A-A (FOR DEPTH UP TO 600MM) SCALE 1: MM THK. GRAVEL FILLING 75MM THK. P.C.C 1:5:10 GENERAL NOTES 1. ALL DIMENSIONS ARE IN MM AND ELEVATIONS ARE IN METER UNLESS NOTED OTHERWISE. 2. ALL DRAINS SHALL BE GIVEN A MINIMUM SLOPE OF 1:1000 IN THE LONGITUDINAL DIRECTION. 3. MINIMUM DEPTH OF DRAIN SHALL BE 300MM BELOW FGL. 4. WHERE EVER TWO SECTIONS ARE MEETING A TRANSITION ZONE SHALL BE CONSTRUCTED HAVING LENGTH 1000MM. 5. DEPTH OFF DRAIN IS TAKEN AS HEIGHT FROM TOP OF DRAIN TO INVERT OF DRAIN. 6. IN CASE OF FILLING AREA, PROPER COMPACTION OF FILLED SOIL SHALL BE CARRIED OUT AS PER TS PRIOR TO LAYING OF DRAIN (TYP.) 2000 (TYP.) LEVEL TO MATCH WITH ROAD SHOULDER MM THK. P.C.C (1:2:4) 75MM THK. P.C.C (1:2:4) 25MM THK. P.C.C (1:2:4) 75MM THK. P.C.C (1:2:4) SECTION X-X (APPLICABLE FOR GRAVEL SIDE) SCALE 1:10 SECTION X-X (APPLICABLE FOR ROAD SIDE) SCALE 1: MS FLAT 15X3(TYP.) DETAIL A SCALE 1:5 DETAIL FOR DRAIN SECTION NEA-HDI-H/I -DR-01 OF 02

16 12MM THK. CEMENT PLASTER WITH NEAT CEMENT FINISH ENTIRE INNER SURFACE AND TOP OF DRAIN F.G.L BRICK WORK WITH CM 1: MM THK. GRAVEL FILLING 75MM THK. P.C.C 1:5:10 12MM THK. CEMENT PLASTER WITH NEAT CEMENT FINISH ENTIRE INNER SURFACE AND TOP OF DRAIN F.G.L MM THK. GRAVEL FILLING 75MM THK. P.C.C 1:5: BRICK WORK WITH CM 1: MM THK. P.C.C 1:2: (MAX.) 25MM THK. P.C.C 1:2: (MAX.) 75MM THK. P.C.C 1:4: MM THK. P.C.C 1:4: SECTION D-D (FOR DEPTH FROM 1200 TO 1500MM) SCALE 1: SECTION B-B (FOR DEPTH FROM 600 TO 900MM) SCALE 1:10 F.G.L 12MM THK. CEMENT PLASTER WITH NEAT CEMENT FINISH ENTIRE INNER SURFACE AND TOP OF DRAIN BRICK WORK WITH CM 1:6 25MM THK. P.C.C 1:2:4 75MM THK. P.C.C 1:4: SECTION C-C (FOR DEPTH FROM 900 TO 1200MM) SCALE 1: (MAX.) MM THK. GRAVEL FILLING 75MM THK. P.C.C 1:5:10 GENERAL NOTES 1. ALL DIMENSIONS ARE IN MM AND ELEVATIONS ARE IN METER UNLESS NOTED OTHERWISE. 2. ALL DRAINS SHALL BE GIVEN A MINIMUM SLOPE OF 1:1000 IN THE LONGITUDINAL DIRECTION. 3. MINIMUM DEPTH OF DRAIN SHALL BE 300MM BELOW FGL. 4. WHERE EVER TWO SECTIONS ARE MEETING A TRANSITION ZONE SHALL BE CONSTRUCTED HAVING LENGTH 1000MM. 5. DEPTH OFF DRAIN IS TAKEN AS HEIGHT FROM TOP OF DRAIN TO INVERT OF DRAIN 6. IN CASE OF FILLING AREA, PROPER COMPACTION OF FILLED SOIL SHALL BE CARRIED OUT AS PER TS PRIOR TO LAYING OF DRAIN. DETAIL FOR DRAIN SECTION NEA-HDI-H/I -DR-02 OF 02