1 BRANZ Appraised Appraisal No. 547 [2007] NURALITE Nuralite Waterproofing Ltd. 53A Victoria Street, Onehunga, Auckland 1061, Zealand TEL: (64) (9) FAX: (64) (9) web: All applications to be installed by an authorised nuralite applicator. All materials to be applied in accordance with standard published installation instruction and product data sheet should be consulted at all times. This drawing is for comment & approval it must not be used for construction until authorised by the site specifier or other relevant technical expert. This detail drawing is to be used only as a part of the nuralite specification package. All drawings are subject to copyright. Unauthorised use is prohibited?nuralite WATERPROOFING Ltd. TIMBER DECKING- ALUMINIUM DOOR DECK THRESHOLD REV E NURAPLY 3P APR 14 DPPT.A1

2 NURAPLY 3P double layer system. "Allproof Sureflow" rainwater outlet at lowest point - with overflow placed elsewhere. Metal cap 75mm min Glass balustrade Balustrade fixings on Nurabond #10 adhesive Fixing sealant detail as per E2/AS1 Clause H3.2 treated timber 20mm min. angle fillet H3.2 treated structure Downpipe. NURAJACK or NURAPAD as specified. TIMBER DECKING- FRAMELESS BALUSTRADE REV E APR 14 DPPT.B1

3 NURAJACK or NURAPAD as specified Toughened Glass Frosted toughened glass Selected "Unex" Handrail post 12mm Aluminum plate 50x50 Aluminum angle drip edge on Nurabond #10 adhesive NURAPLY 3P double layer membrane system Double 190x45mm boundary joists H3.2 treatedtimber fascia "Neoprene" washer M8x150mm stainless steel coach screws over stainless steel washer over polymer washer Gutter bracket Selected gutter "Unex" DKG bracket M8x150mm stainless steel coach screws over stainless steel washer over polymer washer Timber fascia packer beyond TIMBER DECKING- UNEX BRACKET BALUSTRADE Rev E NOV 12 DPPT.B2

4 Holdfast MS Fixall 220 Sealant 12mm min. separation NURAJACK or NURAPAD as specified 75min 150mm min. Nuraply 3P turned into chase. (20x20) Metal overflashing. NURAPLY 3P double layer system. 75min H3.2 treated timber 20mm min angle fillet. CCA treated H3.2 grade 21mm plywood laid to 1:40 min falls. glued & screwed to timber rafters, all edges supported on timber. on Nurabond #10 adhesive TIMBER DECKING- UPSTAND INTO CHASE DPPT.C1

5 Cladding to overlap Nuraply 3P by 75mm minimum. Building paper to lap over Nuraply 3P 12mm min. separation Aluminium or treated timber NURAJACK or NURAPAD as specified 35mm min 75mm 150mm min Termination bar to fasten membrane Nuraply 3P upstand 150mm min. height NURAPLY 3P double layer system. H3.2 treated timber 20mm min angle fillet on Nurabond #10 adhesive TIMBER DECKING- UPSTAND BEHIND CLADDING REV E APR 14 DPPT.C2

6 5 min. slope Note: No min. parapet height required provided membrane fully encapsulates the parapet. Metal overflashing. 70mm min. 70 mm min.. NURAJACK or NURAPAD as specified H3.2 plywood upstand Nuraply 3P flashing strip NURAPLY 3P double layer system. on Nurabond #10 adhesive H3.2 treated timber 20mm min. angle fillet. TIMBER DECKING- PARAPET DPPT.D1

7 12mm min. separation to 1:40 min falls. Glued & screwed to timber rafters, all edges supported on timber NURAJACK swivel head Screwjacks. Aluminium or treated timber NURAPLY 3P double layer system. "Allproof Sureflow" rainwater outlet. at lowest point - with overflow placed elsewhere. Metal cap 35mm min. 100mm min. Selected balustrade Note: Nurapads may be specified instead of Nurajacks. Tapered timber joist may be specified instead of aluminium tube. Downpipe on Nurabond #10 adhesive Fixing sealant detail as per E2/AS1 Figure TIMBER DECKING- OVERVIEW DPPT.E1

8 Selected wall underlay Nuraply 3P double layer system on Nurabond #10 adhesive 20mm nominal drained and vented cavity Stainless steel screw fixing Metal or proprietary rainwater head - fix and seal to face of building NURAJACK or NURAPAD as specified Cut proprietary outlet at angle and allow for recommended for folded drip edge for metal units Overflow below scupper to be same size or larger than downpipe Install flexible flashing tape adhering around outlet and onto wall underlay before cladding installed Seal all round between proprietary outlet & rainwater head to ensure no backflow of water behind Downpipe Selected leaf guard Recess in substrate 1:40 min fall CCA treated H3.2 grade 21mm plywood laid to 1:40 min falls. glued & screwed to timber rafters, all edges supported on timber. Nuraply 3P double layer system Nuralite aluminium scupper sized as specified Selected wall cladding TIMBER DECKING- SCUPPER DPPT.F1

9 "Allproof Sureflow" rainwater outlet at lowest point - with overflow placed elsewhere. NURAJACK or NURAPAD as specified on Nurabond #10 adhesive Rainwater outlet rebated into plywood and screwed into place with S/S screws. Nuraply 3P double layer membrane turned into outlet Downpipe NURAPLY 3P double layer system TIMBER DECKING- SMALL RAINWATER OUTLET DPPT.G1