1 CI/SfB (35) Sm1 August 2016 ROCKFON MediCare Block

2 ROCKFON MediCare Block Specifically designed for use in high-risk, pressurised healthcare environments where high cleanability is required such as emergency rooms, washing facilities and intensive care (compliant with HBN 00-10, TDM 4032:0.6 and HTM 60). For use in operating theatres, seek client approval Does not contribute to the growth of MRSA, high-rated Bacteriological Class B1 and Clean Room Classification ISO Class 2 Very good cleanability properties, chemical resistance classification Ecellent PRODUCT DESCRIPTION Mineral wool tile encased within an air- and watertight inert film Sealed edges ASSORTMENT Edge detail Module size (mm) Weight (kg/m 2 ) MS / MS easy access (mm) A / / 100 MS = Minimum Suspension Recommended installation System ROCKFON System T24 A/E ECR PERFORMANCE Cleaning Vacuum Damp cloth Dry steam cleaning (daily) Chemical resistance: Tests carried out in accordance with ISO ( Determination of resistance to liquids - Part 1: Immersion in liquids other than water ) and classification in accordance with VDI 2083 Part 17. Results are classified as Ecellent with the following detergents and disinfectants: Formalin (37%) Ammonia (25%) Hydrogen peroide (30%) Sulphuric acid (5%) Phosphoric acid (30%) Peracetic acid (15%) Hydrochloric acid (5%) Isopropanol (100%) Sodium hydroide (5%) Sodium hypochlorite (15%) Hygiene Bacteriological class B1 beyond the requirements of Zone 4 (very high risk) defined by NF S Tested with: - Methicillin-Resistant Staphylococcus Aureus (MRSA) - Candida Albicans - Aspergillus Niger Surface durability The high performance inert film of ROCKFON MediCare Block provides enhanced durability and waterrepellence. The film contains DMAc (CAS ) in a concentration 0.1w% and < 1w%. There is no intended release under normal foreseeable conditions of use. Clean Room ISO Class 2 Air pressure Suitable in areas where differential pressure is required to prevent infections from spreading. Due to its high performance film, combined with MediCare clips (8 clips per mm tile), it achieves an air leakage rate of less than 0.5 m³/h/m²/pa under a pressure range of 5 to 40 Pa. For more information, please contact ROCKFON.

3 HEALTHCARE PERFORMANCE Sound absorption α w : 0.85 (Class B) α p Thickness (mm) / Suspension (incl. tile - mm) 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz α w NRC 25 / B 0.85 Absorption class Reaction to fire B-s1,d0 Light reflection 74% Humidity and sag resistance Up to 100% RH Indoor environment A selection of ROCKFON products have been awarded

4 Sealing tape for ROCKFON MediCare Air & ROCKFON MediCare Block To seal -cut tiles, ROCKFON provides an aluminium foil adhesive tape. It has good adhesion on the tile and eliminates fibre emission and dust which is essential in healthcare environments where particle emissions must be avoided. It is quick and easy to use. The sealing tape is air-tight as well as abrasion and humidity resistant. It is 75mm wide and supplied in 50m rolls. 1. Cut 2. Measure edge+10mm & peel 3. Align 5mm overlap on front 4. Press 5. Flip tile to back 6. Peel 7. Fold up & press 8. Form-fold corner 9. Flip tile to front & finish

5 Clips It may be necessary to secure MediCare ceiling tiles on the grid system for some specific applications such as mechanical cleaning/disinfection of the tiles or in pressurised areas where air-tightness is required. ROCKFON recommends placing clips 150mm from the corners, spacing additional clips evenly between them: 8 fiing points for mm tiles and 12 fiing points for mm. The air-tightness of MediCare Air and MediCare Block has been documented. ROCKFON recommends the use of MediCare clips. Three types of clips are available: 1. MediCare plastic clips 2. MediCare stainless steel clips (Single) 3. MediCare stainless steel clips (Double) MediCare plastic clips can be used with 20-25mm thick tiles on grids with a height of 32mm and 38mm and can be manually altered to function as single clips. MediCare steel clips are available in single or double versions. They can be used with 25mm thick tiles on grids with a height of 32mm and 38mm. When using steel clips on 32mm grid, etra care must be taken pressing the clips down. ROCKFON recommends affiing cut tiles along the perimeter trim with an appropriate silicone sealant. Recommended clip layout light fiture light fiture Single steel clip (used where tiles meet fitures) Double steel (used where tiles meet tiles) Plastic clip (used where tiles meet tiles)

6 Air-tight inspection hatch ROCKFON has developed an air-tight inspection hatch in which a ROCKFON ceiling tile (MediCare Plus / MediCare Air surface) is glued into the hatch for a more uniform ceiling surface and better acoustics. The hatch is made of galvanised steel powder-coated white. It is fitted with 2 locking mechanisms and is suitable for Chicago Metallic T24 Click 2890 eposed grid, lay-in ceilings. It is available in mm. A polyester gasket seal ensures air-tightness between the hatch s frame and door. The frame of the hatch sits behind the T-grid. Although it is fairly light (5.25kg including tile), additional hangers on the grid may be necessary to improve stability depending on the installation system. The access hatch should be independently supported and braced to prevent the tile s additional weight, and operating forces eerted on it during installation and operation, being transferred to the lightweight ceiling system. If damaged, the ceiling tile can easily be replaced with a new tile by demounting the locks. Air-tightness of the inspection hatch in combination with MediCare Air is documented. The use of neoprene foam tape on the grid or grid with pre-applied gasket seal is recommended to improve airtightness performance of the entire ceiling / hatch system. A summary of the results is available upon request. For further information, please contact ROCKFON. Uniform ceiling surface and easy opening Easy access to services

7

8 Understanding the unique performance of ROCKFON stone wool products Below is an eplanation of ALL the performance icons and certification for our complete range of ROCKFON stone wool products. For product specific performance, please refer to the information on the individual product datasheet. Sound absorption Sound absorption is measured in accordance with ISO 354. Sound absorption data α p, α w and absorption class are calculated in accordance with ISO Sound absorption properties of islands and baffles are quantified by the equivalent sound absorption area A eq epressed as m² per item. Room-to-room sound insulation Room-to-room sound insulation D n,f,w (C;C tr ) is measured in accordance with ISO Direct sound insulation Sound reduction inde R w (C;C tr ) is measured in accordance with ISO Reaction to fire Reaction to fire is classified in accordance with EN Fire protection The stone wool core of ROCKFON products is non-combustible with a melting point of more than 1000 C and provides fire protection. Some ROCKFON ceilings have been tested and classified in accordance with European norm EN and/or national norms. Light reflection Light reflection epressed in % is measured in accordance with ISO Humidity & sag resistance ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0 C to 40 C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN Certain module sizes (width above 700mm) are Class 2/C/0N. Surface durability The surface of some ROCKFON products is specially treated to provide enhanced durability and dirt resistance. Cleaning Vacuum: The surface can be vacuum cleaned with a soft brush attachment. Damp cloth: The surface can be cleaned using a damp cloth or sponge with a slightly alkaline detergent (ph between 7 and 9) without alcohol, ammonia or chlorine. This may render the surface slightly shinier, so we recommend cleaning the entire surface evenly. Hygiene Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C : Escherichia coli Staphylococcus aureus Methicillin-resistant staphylococcus aureus (MRSA) Stachybotrys chartarum Penicillium brevicumpactum Alternaria tenuissima Aspergillus niger Sporobolomyces roseum Rhodotorula rubra Clean room Clean room classification is measured in accordance with ISO Thermal insulation The thermal conductivity of products with a thickness 30mm is measured in accordance with EN and epressed in mw/mk. Thermal resistance is epressed in m²k/w Subject to alterations in range and product technology without prior notice. ROCKFON accepts no responsibility for printing errors. ROCKFON ROCKWOOL Limited T/A ROCKFON Tel: +44 (0)