MS-200 Installation Guide

Size: px
Start display at page:

Download "MS-200 Installation Guide"

Transcription

1 TAYLOR METAL PRODUCTS MS-200 Installation Guide BUTYL INJECTED SEAL (AVAILABLE) BUTYL INJECTED SEAL (AVAILABLE) 2" 2"

2

3 NOTESTODESIGNER/INSTALLER pg.435 HANDLING/STORAGE&SAFETY..pg.6 EAVEDETAIL..pg.7 HOOKEAVEWITHGUTTERDETAIL pg.8 STANDARDRIDGEDETAIL pg.9 VENTEDRIDGEDETAIL pg.10 STANDARDVALLEYDETAIL.pg.11 ALTERNATEVALLEYDETAIL pg.12 STANDARDGABLEDETAIL pg.13 ALTERNATEGABLEDETAIL..pg.14 SIDEWALLDETAIL.pg.15 RIDGEENDCAPDETAIL.pg.16 VENTEDRIDGEENDCAPDETAIL.pg.17 ROOFPITCHTRANSITIONDETAIL pg.18 ROOFHEADDETAIL..pg.19 VENTEDROOFHEADDETAIL.pg.20 SAWCUTROOFHEADDETAIL..pg.21 BACKPAN/CRICKETISODETAIL pg.22 CURBSIDEWALLDETAIL..pg.23 CURBHEADDETAIL..pg.24 CURBBACKPAN..pg.25 PIPEPENATRATIONDETAIL1.pg.26 PIPEPENATRATIONDETAIL2.pg.27 PIPEPENETRATIONMIDPANEL pg.28 ROOFENDDAMASSEMBLY pg.29 FLASHINGSELECTION.pg.30332

4 TAYLOR METAL PRODUCTS MS-200 MECHANICALLY SEAMED 12 to 18 options available 24 & 22 gauge Tru-Gauge and.032 Aluminum Floating clip system: allows for expansion/contraction of panels in longer lengths FLAT PAN 12 to 18 coverage options 2 Mechanical seam rib, 90 or 180 Factory notching available Factory injected Butyl sealant Structural panel that will span up to 5 Concealed fasteners: fasteners cannot leak Manufactured in Sacramento, CA & Salem, OR - Code compliance UL Evaluation Report UL ER UL580 Class 90 wind uplift, UL Class A fire rated ACCENT RIBS 2 Accent ribs for 12 to 14-5/8 panel 3 Accent ribs for 16 & 18 panel UL Construction No. 90, 176, 180, 238, and 238A ASTM E Structural uniform static air pressure* ASTM Water infiltration* ASTM Water infiltration* ASTM Air infiltration* *requires approved Taylor Metal Product details, consult TMP rep. with application/specification questions Weather tightness warrantly available (Contact TMP representative for details) 1/2:12 minimum pitch recommended: For lower pitches please inquire Standard panel lengths 2 to 65 : For longer pitches please inquire Onsite roll forming available for long lengths STRIATED 90º SEAM DETAL 180º SEAM DETAIL BUTYL INJECTED SEAL (AVAILABLE) BUTYL INJECTED SEAL (AVAILABLE) Panel options: Flat pan, Accent ribs, Striations Retro-fit systems available 2" 2"

5 TAYLOR METAL PRODUCTS MATERIAL SPECIFICATIONS 24 gauge Kynar 500 Painted Steel.0236 (thickness prior to painting) G-90 Galvanized or AZ gauge bare Zincalume Plus with Clear Acrylic Coating - AZ gauge Kynar 500 Painted Steel.029 (thickness prior to painting).032 Kynar 500 Painted Aluminum 22 gauge Rusteel (cold-rolled) 22 gauge Rusteel Plus (A606) 24 gauge Bonderized (G-90) 16 and 20 ounce Copper (please inquire) Kynar and substrate testing data available (see website) KEY FEATURES 20 Standard Colors, 5 Metallic Colors and 4 Specialized Colors Kynar 500 Paint System - the ultimate in exterior durability and color retention Cool color pigments are specially designed to reflect infrared light, reducing heat gain to dwelling, and conform with ENERGY STAR criteria Superior Quality, two coat, 70% resin finish, applied at a 1mm thickness 40 year residential paint warranty 20 and 30 year commercial paint warranty (contact TMP for warranty specifications) KKynar 500 paint layer CCommercial-grade metal primer GG-90 Galvanized or AZ-50 2Base Steel GG-90 Galvanized or AZ-50 CCommercial-grade metal primer C Corrosion resistant wash coat 40-Year Residential/20 and 30 Year Commercial Manufacturer s Limited Warranty STANDARD COOL KYNAR 500 COLORS Metallic Silver SRI-58 Champagne SRI-46 Antique Patina SRI-40 Copper Penny SRI-48 Weathered Zinc SRI oz. and 20 oz. Copper *please inquire* Zincalume Plus SRI-65 Vintage SRI-19 22g Rusteel (cold-rolled) Rusteel Plus (A606) Tahoe Blue SRI-28 Pacific Blue SRI-28 Hemlock Green SRI-36 Forest Green SRI-25 Pine Green SRI-26 Terra Cotta SRI-42 Tile Red SRI-36 Colonial Red SRI-38 Retro Red SRI-41 Black SRI-29 Glacier White SRI-85 Sierra Tan SRI-59 Parchment SRI-58 Sterling Grey SRI-44 Zinc Grey SRI-40 Charcoal Grey SRI-25 Saddle Tan SRI-37 Medium Bronze SRI-33 Musket SRI-31 Dark Bronze SRI-27 1,2 1,2 2 1,2 1,2 1,2 1,2 1,2 1,2 2 1,2 1,2 1,2 1,2 1,2 1, ,2 PREMIUM METALLIC COOL KYNAR COLORS SPECIALIZED MATERIAL 1, ,2 1,2 1,2 These printed chips provide a close representation of the colors. Metal samples are available upon request. Coatings are low gloss 10-15% sheen. SRI = Solar Reflective Index. SRI values listed above are in accordance with ASTM E 1980 and are based on actual testing.***oil canning is not a cause for material rejection*** Standard Panels Width Gauge Color LBS SQFT LBS LF 14-5/8" " " /8".032 Alum RIVERSIDE CA SACRAMENTO CA SALEM OR SEATTLE WA WOODINVILLE WA

6 It is the responsibility of the designer to determine the material types needed to control condensation and to insulate and ventilate the roof system. Applications over rigid insulation may require blocking for solid attachment and framing the perimeter for installation of perimeter flashings. Flat metal surfaces will display waviness commonly referred to as oil canning. Oil canning is caused by a variety of conditions: Steel mill tolerances, variations in or uneven substrates and roofing underlayments. Oil canning is a characteristic of metal roofing, not a defect and is not a cause for rejection. offers with striations or accent ribs to help minimize oil canning. The Panels and the flashings must be allowed to expand and contract, especially with longer length panels. The panel may need to have a slight gap where the panel hooks the offset cleat to allow for thermal movement of the panels. The following details do not address all conditions for snow environments. Consult with the designers, engineers, and others for acceptable details to accommodate your project and climate conditions. When possible, gutters, valleys, pitch changes or other penetrations should be minimized in snow areas. All roof penetrations should be located as close to the ridge or top of roof. Snow country requires special designs for valleys to accommodate accumulation of snow and ice from uphill panels. Roof design should be considered in snow areas. Roof design should help resist the melting and freezing of snow and ice. A fit for purpose roof design has the greatest impact on maintaining a damage free roof system in snow areas. Please contact a Taylor Commercial Products representative for assistance in detail designs and appropriate panel selection for specific climate and building conditions. 3 4

7 Handle materials with care when off-loading or moving materials to avoid damage to panels or flashings. Long panels may require two or more pick-up points, properly spaced to avoid damaging panels. Plan ahead; contact Taylor Commercial Products for recommendations on handling/hoisting long panels. Store the panels, flashings and accessories in a dry, well ventilated area, off the ground. If covering, allow ventilation around panels. Elevate one end of bundle to allow drainage of wet materials. Wear clean, soft-soled shoes when walking on roofing panels to avoid damage to the painted finish. Take care that sand, gravel, dirt, etc. sticking to your shoes is not carried onto the roof, scratching or otherwise damaging the finish on the roofing material. Walking on asphalt impregnated felt paper, especially on a hot day, can cause the asphalt to stick to your shoes and be tracked on to the roofing material. Take care when painting to avoid getting over spray on the roofing material. Remember that wind can carry paint particles some distance. Over spray can cause the finish of the roofing material to look dull and may void your warranty. Secure materials, especially when leaving the site, on the ground or roof to prevent winds from moving the materials. Wind-blown materials may cause damage to the material, property or persons. Always use proper safety equipment and attire to minimize risk of cuts or other injuries. Do not walk on panels that have not been completely installed. Do not walk on major ribs of panels. Metal roofs that are wet or dusty can be extremely slippery. Wear soft soled shoes and a safety harness to minimize risk of falling. Avoid installing metal panels in windy conditions. Safety considerations are the responsibility of the installer and his crew. Be sure to and generally accepted safety practices when installing roofing materials. 4 5

8 is providing the following details as an aid in design. The details in this guide are not inclusive to all design situations. The designer/installer is responsible for modifications and should take into consideration all aspects of the project including climate conditions, such as, snow and wind, as well as, building code requirements, building design, building usage and maintenance requirements. Installation should be performed only by qualified installers familiar with metal roofing systems and industry standards. For details not shown in this guide, refer to the Sheet Metal and Air Conditioning Contractors National Association (SMACNA) architectural sheet metal manual for proper design. The Standard gauge for all products in this guide is 24 gauge and the standard finish is Kynar 500 /Hylar We recommend specifying all flashings be the same gauge, color, and finish as the panels to insure long-term durability and color match. Details in the manual are all shown over solid substrate. can be used over spaced purlins. For solid substrate, recommends 5/8 plywood or metal decking. Minimum underlayment requirements are 30 lb. ASTM rated felt, a synthetic underlayment with Class A and ASTM UV protection technology or a high temperature self-adhering rubberized membrane. When choosing the underlayment, consider the roof slope, roof design, roof panel, and the climate. All panels must be pinned at the top to resist the drag load caused by snow loads, live loads, and the weight of the panel. Drag load is a function of roof slope, actual load and length of panels. Contact for specific drag load requirements. 2 6

9 EAVE HOOK (MES) EAVE EAVE STANDARD (MES) HOOK EAVE EAVE HOOK (MEH) EAVE STANDARD (MES) EAVE HOOK (MSEH) EAVE STANDARD (MSES) 7

10 HOOK EAVE WITH GUTTER BOX GUTTER (MBG) MS200 BOX GUTTER (MSBG) (MBG) 8

11 RIDGE STANDARD (MRS) STANDARD RIDGE RIDGE STANDARD (MRS) 3 RIDGE (MSRS) 9

12 RIDGE VENTED (MRFV) VENTED RIDGE RIDGE VENTED (MRFV) 3 RIDGE VENTED (MSRFV) 10

13 6 VALLEY (MVF) OFFSET CLEAT (MOC) STANDARD VALLEY VALLEY (MVF) OFFSET CLEAT (MOC) 3 6 VALLEY FLASHING (MSVF) 11

14 6 VALLEY (MVF) ALTERNATE VALLEY VALLEY (MVF) 3 6 VALLEY FLASHING (MSVF) 12

15 MS200 Standard Gable TAYLOR METAL PRODUCTS NEOPRENE WASHERED SCREW OR RIVET 12" O.C. DOUBLE BEAD BUTYL TAPE STANDARD GABLE 1 3 4" SCREW 8" O.C. WITH SEALANT OVER TOP SUPPORT FLASHING UPEND PANEL 2" AT " 4 3 8" UNDERLAYMENT WRAPPED DOWN FACE 3" *WEATHERTIGHT WARRANTY ONLY SHEATHING NEOPRENE WASHERED SCREW 12" O.C. 5 8" KICK, 1 2" HEM, STD. GABLE FASCIA 1" STD. GABLE DETAIL 1 2 " 1 2 " 2 1 8" 3" SUPPORT FLASHING 13

16 MS200 Alternate Gable TAYLOR METAL PRODUCTS 2 1 2" 1" 1" 1 3 4" 1 2 " 1 2 " 2 1 8" 4 3 8" 1 2" HEM, 3" 5 8" KICK, 1 2" HEM, ALT. CLOSURE SUPPORT FLASHING ALT. GABLE DETAIL 1" NEOPRENE WASHERED SCREW OR RIVET 12" O.C. DOUBLE BEAD BUTYL TAPE STANDARD GABLE SCREW 8" O.C. WITH SEALANT OVER TOP SUPPORT FLASHING SKINNING GUNNABLE BUTYL UPEND PANEL 2" AT 90 UNDERLAYMENT WRAPPED DOWN FACE 2" *WEATHERTIGHT WARRANTY ONLY CLEAT SCREW 8" O.C. 1 2" KICK 4 1 4" GABLE SUPPORT CLEAT SHEATHING CONTINUOUS CLEAT FASCIA ALT. GABLE DETAIL 14

17 MS200 Side Wall TAYLOR METAL PRODUCTS 1" 4 1 4" 1 2 " 1 2 " 2 1 8" 3" 1 3 4" 1 2" HEM, 1 3 4" SUPPORT FLASHING SIDE WALL WALL PANEL NEOPRENE WASHERED SCREW OR RIVET 12" O.C. DOUBLE BEAD BUTYL TAPE UNDERLAYMENT TURN UP WALL 8" *WEATHERTIGHT WARRANTY ONLY SCREW 8" O.C. WITH SEALANT OVER TOP SIDE WALL UPTURN PANEL 2" AT 90 MS200 PANEL SUPPORT FLASHING SHEATHING UNDERLAYMENT *WEATHERTIGHT WARRANTY ONLY SIDE WALL DETAIL 15

18 RIDGE END CAP (MREC) RIDGE END CAP RIDGE END CAP (MREC) 3 RIDGE END CAP (MSREC) 16

19 6 6 VENTED ENDWALL (MEWV) VENTED RIDGE END CAP VENTED ENDWALL (MEWV) VENTED RIDGE END (MSRECV) 17

20 ENDWALL (MEW) ROOF PITCH TRANSITION END WALL (MEW) END WALL (MSEW) 18

21 ENDWALL (MEW) ROOF HEAD ENDWALL (MEW) END WALL (MSEW) 19

22 VENTED ENDWALL (MEWV) VENTED ROOF HEAD VENTED ENDWALL (MEWV) VENTED END WALL (MSWV) 20

23 ENDWALL (MEW) REGLET (MRF) SAW CUT ROOF HEAD ENDWALL (MEW) REGLET (MRF) 3 END WALL (MSEW) REGLET (MSRF) 21

24 BACK PAN MS200 TAB SIDE WALL TO RECEIVE BACK PAN BACK PAN (MSPAN) PAN FLASHING (MPAN) TAB SIDE WALL TO RECEIVE BACK PAN 22

25 CURB SIDEWALL (MCS) CURB SIDE WALL CURB SIDEWALL (MCS) TURN)SIDE)OF)PANEL)UP CURB SIDE WALL (MSSWC) ⅞ 23

26 CURB HEAD MS200 CURB HEAD (MSCH) (MCD) 24

27 Versa-Span Versa-Span Versa-Span Versa-Span CURB PAN/CRICKET 25

28 PIPE PENETRATION 26

29 PIPE PENETRATION 27

30 PIPE PENETRATION 28

31 END DAM 29

32 MS200 MS200 Flashings (10' Standard) TAYLOR METAL PRODUCTS EAVE STANDARD ( MS200ES ) EAVE HOOK ( MS200EH ) ALT EAVE ( MS200EA ) 3 3 8" 4 3 8" 1 2 " 1 1 2" 1" 1" 3" 1 1 2" SPECIFY PITCH 1 1 2" SPECIFY PITCH 1 1 2" SPECIFY PITCH 5 8" KICK, 1 2" HEM, 5 8" KICK, 1 2" HEM, 5 8" KICK, 1 2" HEM, SCALE 1:3 S.O. 6" WEIGHT: 4.9 LBS. SCALE 1:3 S.O. 8" WEIGHT: 6.5 LBS. SCALE 1:3 S.O " WEIGHT: 2.5 LBS. BOX GUTTER ( MS200BG ) SUPPORT FLASHING ( MS200SF ) GABLE STANDARD ( MS200GS ) 1 3 4" 1" 1" 1" 1 2" HEM, 3 1 4" 5 1 2" 1 2 " 1 2 " 1" 2 3 8" FM " MS " 4 3 8" 6" 2X 108 4" 3 8 " FM " MS200 3" 5 8 " KICK, 1 2 " HEM, SCALE 1:4 S.O " WEIGHT: 13.3 LBS. SCALE 1:3 S.O " / 7.125" WEIGHT: 6 LBS. SCALE 1:4 S.O. 9.5" WEIGHT: 7.6 LBS. ALT GABLE ( MS200AG ) GABLE SUPPORT CLEAT ( MS200GC ) ALT L CLOSURE ( MS200ALC ) 1 2 " 2 1 2" 4 3 8" 1" 4 1 4" 1 3 4" 1" 1 2" HEM, 5 8 " KICK, 1 2 " HEM, 1 2 " KICK SCALE 1:4 S.O. 8.5" WEIGHT: 7 LBS. SCALE 1:4 S.O. 5.75" WEIGHT: 4.7 LBS. SCALE 1:3 S.O. 3.25" WEIGHT: 2.5 LBS. 30

33 MS200 MS200 Flashings (10' Standard) TAYLOR METAL PRODUCTS RIDGE ( MS200RS ) VALLEY FLASHING ( MS200VF ) 7" SPECIFY PITCH 11" 1" SPECIFY PITCH 1" HEM, SCALE 1:5 S.O. 16" WEIGHT: 13.2 LBS. SCALE 1:6 S.O. 24" WEIGHT: 19.7 LBS. VENTED ENDWALL ( MS200EWV ) VENTED RIDGE ( MS200RFV ) SPECIFY PITCH 4 3 8" 8" 5" 1 1 2" 5 8 " SPECIFY PITCH 1 1 2" 5 8 " 2X " HEM, 4X " HEM, SCALE 1:5 S.O. 12" WEIGHT: 10.0 LBS. SCALE 1:6 S.O " WEIGHT: 17.5 LBS. ZEE CLOSURE ( MS200ZC ) SCALE 1:5 REGLET ( MS200RF ) SCALE 1:5 ENDWALL ( MS200EW ) SCALE 1:5 RIDGE END CAP SCALE 1:5 CLEAT ( MS200RECC / MS200VRECC ) 1" 1" 1" 1 2" HEM AT 30 5" 1 7 8" 3 5 8" 5 7 8" Vented 5 1 4" Standard 1" 1 2" HEM, 6" 1" HEM, SPECIFY PITCH 1 2" KICK AT 35 S.O " WEIGHT: 3.4 LBS. S.O " WEIGHT: 4.8 LBS. S.O. 12" WEIGHT: 10.0 LBS. S.O. 6.75" / 7.375" WEIGHT: 5.9 LBS. 31

34 MS200 MS200 Flashings (10' Standard) TAYLOR METAL PRODUCTS RIDGE END CAP MS200REC VENTED RIDGE END MS200RECV HAT FLASHING 7" 1 1 2" 6" SPECIFY PITCH SPECIFY PITCH 5 3 8" 5 8 " 6" 1 2 " 1 1 2" 3 8 " 1 2" HEM, 1" HEM, 3 4 " 5 8" KICK, 1 2" HEM, 5 8 " KICK, 1 2 " HEM, SCALE 1:4 S.O. 14.5" WEIGHT: 12.0 LBS. SCALE 1:5 S.O " WEIGHT: 13.0 LBS. SCALE 1:3 S.O. 4" WEIGHT: 2 LBS. BACK PAN MS200PAN SIDEWALL ( MS200SW ) CURB HEAD MS200CH 4 1 4" 5 1 2" 5" " 1 3 4" 1 2" HEM, 6" 1 3 4" 1" HEM, SCALE 1:10 S.O. 24" WEIGHT: 10.0 LBS. SCALE 1:3 S.O. 8.25" WEIGHT: 7.0 LBS. SCALE 1:5 S.O. 12" WEIGHT: 9.9 LBS. CURB SIDEWALL MS200CSW END DAM END DAM IS EXAMPLE ONLY SEE SPECIFIC END DAM DETAIL SHEET FOR DIMENSIONS (SEPARATE FORM) 4" PERFORATED STRIP MS200PS 1 1 2" 1 7 8" 19" 4" 4" " 1 1 2" 1 2" HEM, 4" 2" SCALE 1:5 S.O. 10" WEIGHT: 8.3 LBS. SCALE 1:10 S.O. VARIES WEIGHT: VARIES SCALE 1:5 S.O. 4" WEIGHT: 2.5 LBS. 32

35 Custom Trim Order Customer Name: Job Name: Drawing #: Pitch: # of Pieces: Description: Hems: Open Closed Slightly Open Drawing #: Pitch: # of Pieces: Description: Hems: Open Closed Slightly Open Drawing #: Pitch: # of Pieces: Description: Hems: Open Closed Slightly Open Drawing #: Pitch: # of Pieces: Description: Hems: Open Closed Slightly Open Please provide a drawing for each flashing with precise measurements and angles Fax to: Ridge Dr NE Salem OR Phone: or

36 Fax to: Order Form New Order Add-on Order PO# Date: Inside Sales: Sold To: Job Name: Ship To: Order Contact: Phone # Fax # Will Call Delivery Date: Panels with need Pattern Choice * Color: 12" Easy-Lock* Shadow Line* 16" Easy-Lock* Soffit* 16" StreamLine* Smoothwall* Pattern Choices: T-3 Flat Striations Tuff Rib Ribs Notched? Y N Panel & Flashing Items Marion R Panel HR-34 GR7 GR5 PBR 12-3/4" MS150* 2-1/2" Corrugated 16-5/8" MS150* Classic 7/8" Corrugated 14-5/8"MS200* Pattern Choices: Ribs Flat Pitch: Striations Gauge Clip Relief? Y N Sealant? Y N Notched? Y N 14-5/8" Versa Span* 18" Versa Span* 18" MS200* *All Kynar, Easy-Lock, Soffit, & Smoothwall, Clip Lock, MS150, Versa Span, MS200 flashings are 10' *All Armor Tech 26 and 29 Gauge. StreamLine, T-3, Tuff Rib, GR7, PBR, Corrugated, & GR5 flashings are 12'6" Quantity Length Item Description Quantity Length Item Description Forgetting Anything? Underlayment? Screws? Clips? Caulking? Closures? 4566 Ridge Dr NE Salem, OR F: P

37

38

39

40 TAYLOR METAL PRODUCTS QUALITY PRODUCTS EXCEPTIONAL SERVICE SALEM BRANCH 4566 Ridge Drive NE Salem, OR Office: Toll Free: Fax: MCCLELLAN BRANCH 5711 Perrin Ave McClellan, CA Office: Toll Free: Fax: WOODINVILLE BRANCH th St. SE Woodinville, WA Office: Toll Free: Fax: AUBURN BRANCH 710 A St. NW Suite 101 Auburn, WA Office: Toll Free: Fax: RIVERSIDE BRANCH 4880 Felspar St. Riverside, CA Office: Toll Free: MS-200 Installation Guide Taylor Metal Products