BlazeFrame product catalog STRONGER. clarkdietrich.com/blazeframe

Size: px
Start display at page:

Download "BlazeFrame product catalog STRONGER. clarkdietrich.com/blazeframe"

Transcription

1 BlazeFrame product catalog STRONGER T H A N S T E E L. SM I N T E G R AT E D F I R E S T O P S Y S T E M S /BlazeFrame

2 2 BlazeFrame Design Advantages What is BlazeFrame? BlazeFrame products are innovative steel framing profile/intumescent composites, that combine ease of installation, inspection, life safety and joint protection dependability into one unique product. How does it work? Using a cured factory metered dosage intumescent material, BlazeFrame profiles provide fire stopping, smoke and sound dampening that is effective immediately after framing components are installed. When exposed to heat above 375 F, the intumescent material expands up to 35 times its size. This provides additional protection from heat and flame passage during a fire event. What does it replace? BlazeFrame's factory metered dosage intumescent material eliminates elastomeric fire proofing caulks and spray. The cured intumescent tape eliminates VOC's and off gases associated with caulked spray fire proofing. With the intumescent tape factory applied it eliminates both overage and underage often associated with the messy caulks and sprays. BLAZEFRAME FIRE STOP DEEP LEG DEFLECTION TRACK (DL2, DSL2) One to three hour assembly CONCRETE DECK 1, 2, 3, LAYERS FOR 1, 2, 3 HR RATING BlazeFrame Advantages: Installed & inspected as "joint framing" (before obstructions) Unaffected by dirty, oily, wet or freezing conditions Cured intumescent effective immediately (no VOC) No fatigue to joint or substrate materials for life of assembly Pub. No. CD-BlazeFrame 9/12 The technical content of this literature is effective 9/10/12 and supersedes all previous information.

3 3 Fire Stopping UL 2079 Classified and listed for up to 3 hr assemblies Protection for up to 3" overall movement capability (1-1/2" up and 1-1/2" down) Eliminates fire proofing caulks and sprays Shaftwall Assemblies certified for use with all UL listed "liner" boards and finish side gypsum products Sound Dampening NVLAP certified to provide up to STC 62 (based on wall assembly) Open unencumbered joints (no caulk required) Fluted deck exposed with only BlazeFrame Deck Plug or Flute Cover STC = 50+ Expanded intumescent strip after fire test Smoke barrier-air leakage - IBC 2009 BlazeFrame assemblies have been UL Classified with the lowest possible L-Rating (less than 1 CFM/lft). Seismic Requirements BlazeFrame is UL 2079 Classified for Class III Cycling of 500 cycles at 30 cycles per minute of vertical movement which may be capable of meeting seismic design and building code requirements. Code Compliance BlazeFrame joint protection complies with up to date building codes and is listed by Underwriters Laboratories Inc. BlazeFrame deflection track & deck plugs in sound test UL 2079 ASTM E-1966 ASTM E-814 ULC S115-M95 ASTM E-119 ASTM E-2837 Tests for Fire Resistance of Building Joint Systems Standard Test Method for Fire Resistive Joint Systems Standard Method of Fire Tests of Fire Stop Systems Standard Method of Fire Tests of Fire Stop Systems Evaluation of a Non-Load Bearing Wall Assembly with a Control Joint Backer Rated Wall Assemblies Installed to Non-Rated Assemblies (pending) The technical content of this literature is effective 9/10/12 and supersedes all previous information. Pub. No. CD-BlazeFrame 9/12

4 4 BlazeFrame Design Advantages CONCRETE DECK CONDITION CONCRETE DECK BLAZEFRAME FIRE STOP DEEP LEG DEFLECTION TRACK (DL2, DSL2) 1, 2, 3, LAYERS FOR 1, 2, 3 HR RATING Clean transition from wall sheathing to substrate. Exposed and finished joints are fire and sound rated. METAL DECK CONDITION MINERAL WOOL FLUTE FILL BLAZEFRAME FIRE STOP DEEP LEG DEFLECTION TRACK (DL2, DSL2) 1, 2, 3, LAYERS FOR 1, 2, 3, HR RATING ATTACH GYPSUM PER UL DESIGN REQUIREMENT Head of Wall assembly complete before studs are installed. Mineral wool only needed for flute fill. Earlier, easier, and accurate inspection. Pub. No. CD-BlazeFrame 9/12 The technical content of this literature is effective 9/10/12 and supersedes all previous information.

5 5 BEAM PENETRATION CONDITION METAL PAN DECK ANGLE OR Z-CLIP CENTERED BLAZEFRAME FIRE STOP DEEP LEG DEFLECTION TRACK (DL2) FIRE PROOFING or MINERAL WOOL Eliminates contour cutting of wall sheathing, caulks/sprays. Spray fire proofing or mineral wool are the easy option for beam cavity fill. PARALLEL OFFSET CONDITION 14GA STRAP / ANGLE OUTRIGGER BLAZEFRAME OFFSET DEEP LEG DEFLECTION TRACK (ODL2, ODSL2) Eliminates z-clips, lath basket, voids in fire proofing. 14 ga angle outrigger/profile preassembled prior to installation. The technical content of this literature is effective 9/10/12 and supersedes all previous information. Pub. No. CD-BlazeFrame 9/12

6 6 BlazeFrame Sample Profiles DSL 2 (DEEP LEG - SLOTTED BOTH SIDES) Profile with two slotted legs w/ fire stop on both sides Composite Fire Stop/Framing for use in fire rated wall assemblies. Provides 100% unencumbered joint protection. Accommodates up to 1 1/2 overall movement with UL 2019 Level III Certification. Minimum CP60 coating. Legs with slots spaced 1 o.c. for positive attachment of studs per listed assemblies in UL Fire Resistance Directory. s: 2-1/2", 3-5/8", 4", 6" and 8" Thicknesses: 33mils (20ga), 43mils (18ga) and 54mils (16ga) Profile Leg Length Tape Slot Height (S) Joint Protection DSL DSLW DSLX * * 4 leg length is not available for 2-1/2 wide system (S) Fastener mid-height of exposed slot SL 1 (DEEP LEG - SLOTTED ONE SIDE) Profile with one slotted leg and one solid leg w/ fire stop on slotted side Composite Fire Stop/Framing for use in fire rated wall assemblies. Provides 100% unencumbered joint protection. Accommodates up to 1 1/2 overall movement with UL 2019 Level III Certification. Minimum CP60 coating. One leg with slots spaced 1 o.c. for positive attachment of studs per listed assemblies in UL Fire Resistance Directory. s: 2-1/2", 3-5/8", 4", 6" and 8" Thicknesses: 33mils (20ga), 43mils (18ga) and 54mils (16ga) Profile Slotted Leg Length (L1) Solid Leg Length (L2) Tape * 4 leg length is not available for 2-1/2 wide system Slot Height (S) Joint Protection SL SLW SLX * (L2) (L1) Pub. No. CD-BlazeFrame 9/12 The technical content of this literature is effective 9/10/12 and supersedes all previous information.

7 7 DL (DEEP LEG - SOLID) Composite Fire Stop/Framing for use in fire rated wall assemblies. Provides 100% unencumbered joint protection. Accommodates up to 3 overall movement with UL 2019 Level III Certification. Minimum CP60 coating. Two solid legs supporting free floating studs per listed assemblies in UL Fire Resistance Directory. s: 2-1/2", 3-5/8", 4", 6" and 8" Thicknesses: 33mils (20ga), 43mils (18ga) and 54mils (16ga) (DL 1 Series) Profile with two solid legs w/ fire stop on one side (DL 2 Series) Profile with two solid legs w/ fire stop on both sides (DL 1 Series) Profile Leg Length Tape Joint Protection DL DLW DLX DLZ DLY 4.00 * (DL 2 Series) * 4 leg length is not available for 2-1/2 wide system JR (J-RUNNER) Profile with two solid legs w/ fire stop on one side Composite Fire Stop/Framing for use in up to 3 hr fire rated shaft wall assemblies. Provides 100% unencumbered joint protection. Accommodates up to 1 1/2 overall movement with UL 2019 Level III Certification. Minimum CP60 coating. One leg (front) having intumescent per listed assemblies in UL Fire Resistance Directory. s: 2-1/2", 4" and 6" Thicknesses: 33mils (20ga), 43mils (18ga) and 54mils (16ga) Profile Front Leg Length (FL) Back Leg Length (BL) Tape Joint Protection JR JRW (BL) (FL) JRX The technical content of this literature is effective 9/10/12 and supersedes all previous information. Pub. No. CD-BlazeFrame 9/12

8 8 BlazeFrame Sample Profiles ODL 2 (OFFSET DEEP LEG) Profile with two solid legs w/ fire stop on both sides Composite Fire Stop/Framing with offset step accommodates 1-1/4 thick fireproofing in head of wall and wall to wall (column) assemblies. (Other offset depths available to accommodate other sprayed thicknesses). Provides 100% unencumbered joint protection. Accommodates up to 2 overall movement with UL 2079 Level III Certification. Minimum CP60 coating. Two solid legs per listed assemblies in UL Fire Resistance Directory. s: 3-5/8", 4", 6" and 8" Thicknesses: 33mils (20ga), 43mils (18ga) and 54mils (16ga) Profile Lower Leg Length Tape Joint Protection ODL ODLW ODLX ODLZ (1-1/4 )* * Other offset step depths available ODSL 2 (OFFSET DEEP SLOTTED LEG) Profile with two slotted lower legs w/ fire stop on both sides Composite Fire Stop/Framing with offset step accommodates 1-1/4 thick fireproofing in head of wall and wall to wall (column) assemblies. (Other offset depths available to accommodate other sprayed thicknesses). Provides 100% unencumbered joint protection. Accommodates up to 1-1/2 overall movement with UL 2079 Level III Certification. Minimum CP60 coating. Two legs with slots spaced 1 o.c. for positive attachment of studs per listed assemblies in UL Fire Resistance Directory. s: 3-5/8", 4", 6" and 8" Thicknesses: 33mils (20ga), 43mils (18ga) and 54mils (16ga) Profile Lower Leg Length Tape Slot Height (S) Joint Protection ODSL ODSLW (1-1/4 )* ODSLX * Other offset step depths available Pub. No. CD-BlazeFrame 9/12 The technical content of this literature is effective 9/10/12 and supersedes all previous information.

9 9 FC (FLUTE COVER) Profile strap for under fluted decks Corrugated strap for horizontal use to span fluted areas of unprotected or protected metal decks in up to 2 hr rated assemblies. Profile attached to deck valley surfaces a max 16 o.c. on both sides. Profiles provide a surface area for attachment of head of wall partition track profiles centered or offset underneath and parallel to deck fluted areas per listed assemblies in UL Fire Resistance Directory. FLUTED DECK Sizes: 675 (6-3/4 ) or 700 (7 ) Length: 10'-0" Thicknesses: 33mils (20ga) varies to match flute opening (DL2, DSL2) BLAZEFRAME (FC) FLUTE COVER (continuous) CJB (CONTROL JOINT BACKER) Profile for protection of control joints Composite Fire Stop/Control Joint Backer for use to protect Architectural design joints (optional control joint over gap) for up to 2 hr rated assemblies. Minimum G40 coating. Provides a metal profile which supports intumescent materials located inside and spanning gap between opposing drywall edge at control joint locations. Also eliminates the need for a second stud in the gypsum assembly. Wallboard Steel Stud : 3-1/4" Length: 10'-0" Thicknesses: 18mils (25ga) Packaging: 14 Pcs./Ctn. Eliminates the need for a second stud in the gypsum assembly Profile Intumescent Profile Thickness CJB " 3.25".018" 093 Control Joint CJB - Control Joint Backer The technical content of this literature is effective 9/10/12 and supersedes all previous information. Pub. No. CD-BlazeFrame 9/12

10 10 BlazeFrame Sample Details Post Tension or Structural Concrete Overhead PT-1 HW-D-0498 Chase Wall Post Tension or Structural Flat Concrete PT-2 HW-D-0505 BLAZEFRAME FIRE STOP DEEP LEG DEFLECTION TRACK (DL2, DSL2) CONCRETE DECK 1, 2, 3, LAYERS FOR 1, 2, 3 HR RATING TRACK/FIRE STOP (DL1, SL1) CONCRETE DECK Perpendicular Unprotected Deck (UD) Mineral Wool Fill UD-1 HW-D-0513 Head of Wall Beam Penetration SS-1 HW-D-0495 METAL PAN DECK MINERAL WOOL FLUTE FILL BLAZEFRAME FIRE STOP DEEP LEG DEFLECTION TRACK (DL2, DSL2) 1, 2, 3, LAYERS FOR 1, 2, 3, HR RATING ANGLE OR Z-CLIP CENTERED BLAZEFRAME FIRE STOP DEEP LEG DEFLECTION TRACK (DL2) ATTACH GYPSUM PER UL DESIGN REQUIREMENT FIRE PROOFING or MINERAL WOOL Pub. No. CD-BlazeFrame 9/12 The technical content of this literature is effective 9/10/12 and supersedes all previous information.

11 11 Centered Under Flute Unprotected Deck (UD) Flute Cover UD-6 HW-D-0544 Perpendicular Protected Deck (PD) Mineral Wool Flute Fill PD-12 HW-D-0513 FLUTED DECK FIRE PROOFING (DL2, DSL2) BLAZEFRAME (FC) FLUTE COVER (continuous) TRACK/FIRE STOP (DL2, DSL2) MINERAL WOOL Parallel Under Structural Support (Z-Clips) SS-16 HW-D-0502 Wall to Wall Gypsum to Protected Steel (I-Beam) VM-3 Design Based on WW-S-0055 HW-D-0558 FIRE PROOF COATING BLAZEFRAME OL PROFILE (ODL2) Z-CLIPS STEEL COLUMN TRACK/FIRE STOP (DL2, DSL2) The technical content of this literature is effective 9/10/12 and supersedes all previous information. Pub. No. CD-BlazeFrame 9/12

12 12 BlazeFrame Sample Details Wall to Wall Gypsum to Concrete Column/Wall VM-1 WW-S-0055 Hollow Steel Shape - Non Rated SS-21 Design Based on HW-D-0543 HW-D-0559 CONCRETE COLUMN / WALL CH, CT, OR I STUD 093 CONTROL JOINT (optional) TRACK / FIRESTOP (DL2) TRACK / FIRE STOP (JR1) SHAFT LINER BOARD Parallel Under Structural Support (Offset Leg Profile) SS-2 HW-D-0502 Edge of Structural Support with Angle (Offset Leg Profile) SS-28 HW-D GA STRAP / ANGLE OUTRIGGER TRACK / FIRE STOP OL - SERIES (ODL2, ODSL2) BLAZEFRAME OFFSET DEEP LEG DEFLECTION TRACK (ODL2, ODSL2) Pub. No. CD-BlazeFrame 9/12 The technical content of this literature is effective 9/10/12 and supersedes all previous information.

13 13 Under UL G500 Series Design VM-6 HW-D-0503 Bottom of Wall VM-12 BW-S-0021 FURRING CHANNEL TRACK / FIRE STOP (DL2, DSL2) TRACK / FIRE STOP (DL2) CONCRETE FLOOR ECA - End Cap Angle Exterior Corner Application Flat Strap Patch Vertical Cavity Obstructions FIELD MODIFIED - VERTICAL OBSTRUCTION TOP VIEW INSERT ECA TOP VIEW TOP VIEW SIDE VIEW SIDE VIEW INSERT ECA ECA ATTACHED WITH FASTENER INTERSECTING WALL BLAZEFRAME BUTTED BLAZEFRAME FSP (Flatstrap Patch) FASTEN FSP TO OUTER SURFACE OF TRACK LEG The technical content of this literature is effective 9/10/12 and supersedes all previous information. Pub. No. CD-BlazeFrame 9/12

14 14 BlazeFrame Sample Details Shaft Wall Post Tension or Structural Concrete PT-3 HW-D-0496 Shaft Wall Perpendicular to Unprotected Deck UD-10 HW-D-0504 MINERAL WOOL or FIRE PROOFING CONCRETE DECK TRACK / FIRE STOP (JR1) MINERAL WOOL BLAZEFRAME COMPOSITE TRACK / FIRE STOP (JR1) MINERAL WOOL LINER BOARD 3 LAYERS FOR 3 HOUR RATING LINER BOARD CH, CT, OR I STUD FASTENER AT BOTTOM OF OBSTRUCTION (when exists) CT, CH, OR I STUD CJB - Control Joint Backer one side 1-hour CJB - Control Joint Backer two sides 2-hour CONTROL JOINT BLAZEFRAME CJB CONTROL JOINT BACKER 093 CONTROL JOINT BLAZEFRAME CJB CONTROL JOINT BACKER Pub. No. CD-BlazeFrame 9/12 The technical content of this literature is effective 9/10/12 and supersedes all previous information.

15 Material: Material: Material: Dimensions: Address: City/ST/ZIP: Address: Dimensions: Project Information Address: City/ST/ZIP: Track length: 10-0 Lower Leg Length ASTM A1003, C955 UL2079, E814, E1966, E119 Length Tape Contact: Phone: Fax: Gap Tape Slot Height (S) (S) Contact: Phone: Fax: Flange Wallboard Contractor Information Contact: Phone: Fax: Slot Height (S) Joint Protection 1.00 Joint Protection Contact: Phone: Fax: (1-1/4 ) ** Contact: Phone: Fax: Architect Information Contact: Phone: Fax: (W) ** Other offset step depths available (W).22 exposed slot Sales: Code Approvals UL Approvals UL Control - R25833 (US)- 1, 2 and 3 hr designs - UL 2079 standard compliant UL Listings HW-D-0495 HW-D-0496 HW-D-0497 HW-D-0498 HW-D-0499 HW-D-0500 HW-D-0501 HW-D-0502 HW-D-0503 HW-D-0504 HW-D-0505 HW-D-0506 HW-D-0512 HW-D-0513 HW-D-0543 HW-D-0544 HW-D-0558 HW-D-0559 HW-D-0597 HW-D-0631 HW-D-0632 HW-D-0633 WW-S-0055 BW-S-0021 Protected Beam Penetration Under Flat Concrete (shaft wall) Parallel to Protected Beam (shaft wall) Under PT or Structural Concrete Parallel to Unprotected Fluted Metal Deck Perpendicular Unprotected Fluted Metal Deck Parallel to Beam (standard wall) Parallel & Edge Overlap Under Structural Support Under Layer Type C UL 500 Series Designs Under Unprotected Fluted Metal Deck (shaft wall) Under PT or Structural Concrete (chase wall) Under Fluted Metal Deck (chase wall) Perpendicular Protected Deck w/fire Proofing Flute Fill Perpendicular Unprotected Deck w/mineral Wool only Flute Fill Stair Shaft (093 Control Joint Optional) Parallel under Flute (Flute Cover Plate) Offset Leg Standard Wall Protected Roof Deck/Substrate Offset Leg Shaft Wall Protected Roof Deck/Substrate Parallel to Beam (Z-clip & Drywall Rip) Shaft Wall Parallel & Edge Overlap Under Structural Support PT or Structural Concrete Bare Slotted with Caulks Fluted Metal Deck Bare Slotted with Flute Plate/Caulks Vertical Wall to Wall Joint Bottom of Wall Details shown are a limited sample of assemblies based on UL certified and listed assemblies. Additional assembly details, submittal sheets, and constructability designs are periodically added upon design and approval. Information can be viewed, downloaded, and printed from (CJB) CJB (Control Joint Backer) Composite Fire Stop/Control Joint Backer for use to protect Architectural design joints (optional control joint over gap) for up to 2 hr rated assemblies. between opposing drywall edge at control joint locations. Also eliminates the need for a second stud in the gypsum assembly. Yield Strength: Grade 33ksi Coating: G40 18mils: 25 Gauge, Design Thickness, Min. Thickness Dimensions: : 3-1/4 Length: 10-0 Packaging: 14 Pieces/Carton Project Information Intumescent CJB ASTM A1003, C955 WFCI is www. Project Information City/ST/ZIP: Product Submittal Sheet Technical Services: Engineering Services: ODSL 2 (Offset Slotted Leg) Two offset slotted lower legs Composite F up to 1-1/2 thick in head of wall and wall to wall (column) assemblies. Provides 100% unencumbered joint protection. Accommodates up to 3 overall legs with slots spaced 1 o.c. for positive attachment of studs per listed assemblies in UL Fire Resistance Directory. provides air, smoke and sound seals. When exposed to heat above 325 degrees Fahrenheit, the intumescent material expands up to 35 times its size. Eliminates the need for a second stud in the gypsum assembly Yield Strength: Grade 33ksi for 33mils & 43mils, 50ksi for 54mils Coating: CP60 (G90 available) 33mils: 20 Gauge, Design Thickness, Min. Thickness 43mils: 18 Gauge, Design Thickness, Min. Thickness 54mils: 16 Gauge, Design Thickness, Min. Thickness Inside width: Equal to the outside width of the stud s (W): 3-5/8, 4, 6 and 8 Contractor Information Sales: Steel Stud 093 Control Joint CJB - Control Joint Backer CD-BlazeFrame-CJB 08/12 ClarkDietrich Building Systems Architect Information - ClarkDietrich products are manufactured from cold-formed steel. Steel is 100% recyclable, which helps divert debris from the waste stream. The contribution to LEED must be calculated by the contractor based on weight or volume. - ClarkDietrich s steel products have a minimum of 25.5% post-consumer recycled content, and 6.8% pre-consumer. If you wish to report a higher number for your project or seek Credit MR 5 please contact Technical Services at or visit ODSL ODSLW ODSLX * is www. * 4 leg length is not available for 2-1/2 wide system Product Submittal Sheet Technical Services: Engineering Services: Yield Strength: Grade 33ksi for 33mils & 43mils Grade 50ksi for 54mils Coating: CP60 (G90 available) 33mils: 20 Gauge, Design Thickness, Min. Thickness 43mils: 18 Gauge, Design Thickness, Min. Thickness 54mils: 16 Gauge, Design Thickness, Min. Thickness Inside width: Equal to the outside width of the stud s (W): 2-1/2, 3-5/8, 4, 6 and 8 Vertical slots: 0.22 wide & spaced every 1 o.c. Track length: 10-0 DSL DSLW DSLX * Technical Services: Engineering Services: Composite Fire Stop/Framing for 100% unencumbered joint protection. Accommodates up to 1 1/2 overall with slots spaced 1 o.c. for positive attachment of studs per listed assemblies in UL Fire Resistance Directory. provides air, smoke and sound seals. When exposed to heat above 325 degrees Fahrenheit, the intumescent material expands up to 35 times its size. Leg - ClarkDietrich products are manufactured from cold-formed steel. Steel is 100% recyclable, which helps divert debris from the waste stream. The contribution to LEED must be calculated by the contractor based on weight or volume. - ClarkDietrich s steel products have a minimum of 25.5% post-consumer recycled content, and 6.8% pre-consumer. If you wish to report a higher number for your project or seek Credit MR 5 please contact Technical Services at or visit * 4 leg length is not available for 2-1/2 wide system ASTM A1003, C955 UL2079, E814, E1966, E119 is www. - ClarkDietrich products are manufactured from cold-formed steel. Steel is 100% recyclable, which helps divert debris from the waste stream. The contribution to LEED must be calculated by the contractor based on weight or volume. - ClarkDietrich s steel products have a minimum of 25.5% post-consumer recycled content, and 6.8% pre-consumer. If you wish to report a higher number for your project or seek Credit MR 5 please contact Technical Services at or visit Contractor Information CD-BlazeFrame-DSL2 08/12 ClarkDietrich Building Systems Architect Information Product Submittal Sheet CD-BlazeFrame-ODSL2 08/12 ClarkDietrich Building Systems Fastener mid-height of Sales: NEED TO SEND PRODUCT SUBMITTALS? Build BlazeFrame Product Submittals for your next project. Use ClarkDietrich's SubmittalPro Product Submittal System to create and send a PDF package of BlazeFrame's product information and technical submittals based on your project's layout conditions. Launch SubmittalPro from The technical content of this literature is effective 9/10/12 and supersedes all previous information. Pub. No. CD-BlazeFrame 9/12

16 Turn to ClarkDietrich for a complete lineup of steel construction products and services nationwide: Interior Framing Exterior Framing Interior Finishing Clips/Connectors Metal Lath/Accessories Engineering 9100 Centre Pointe Dr. Suite 210 West Chester, OH P F Clarkwestern Dietrich Building Systems LLC CD-BlazeFrame 9/12 ClarkDietrich Building Systems. The technical content of this literature is effective 9/10/12 and supersedes all previous information.