BREEAM UK New Construction 2014 Pre Assessment Estimator

Size: px
Start display at page:

Download "BREEAM UK New Construction 2014 Pre Assessment Estimator"

Transcription

1 BREEAM UK New Construction 2014 Pre Assessment Estimator General information BRE Assessment reference no. Client name Building end user/occupier Assessor name Assessor organisation Building details Building name Country Building type (main description) Building type (sub group) Building floor area (GIA) m 2 Building floor area (NIFA) m 2 BREEAM scheme BREEAM version BREEAM UK 2014 technical manual issue number Project type Assessment stage Location type If applicable, does this industrial building have a heated or cooled operational area? Does water heating contribute less than 10% of the buildings total energy consumption? Commercial/industrial refrigeration and storage systems Building user transportation systems (lifts and/or escalators) Laboratory function/area and size category Laboratory containment level Fume cupboard(s) and/or other containment devices Unregulated water uses present? (e.g. vehicle wash system, irrigation) If applicable, will this healthcare building house inpatients? If applicable, does this industrial building have an office area? If applicable, does this building contain areas requiring SAP assessment? If SAP used, what proportion of the building's total floor area (GIA) does it apply to? Copyright The BREEAM name and logo are registered trademarks of the Building Research Establishment Limited (SD5076) Cat Level 1 only Yes Small/medium urban (>10,000 population) Copyright exists on the BREEAM logo and this may not be used or reproduced for any purpose without the prior written consent of the BRE Global Ltd. Disclaimer This Pre Assessment Estimator is the property of BRE Global Ltd and is made publicly available for information purposes only. Its use for testing, assessment, certification or approval is not permitted. The results presented are indicative only of a building's potential performance which is based on a simplified, informal assessment and unverified commitments. The results do not represent a formal certified BREEAM assessment or rating and must not be communicated as such. BRE Global Ltd accepts no responsibility for any actions taken as a result of information presented or interpreted by the BREEAM Pre Assessment Estimator. To carry out a formal BREEAM assessment contact a licensed BREEAM Assessor organisation. A list of licensed BREEAM Assessors is available from the Green Book Live website: to be confirmed No New Construction SD5076 Issue 3.0 England Industrial Industrial Process / manufacturing unit 8500 Rye House Energy from Waste Plant Option not applicable to building type Yes Yes Yes Laboratory present: <10% of building's Gross Internal Floor Area Lagan Construction Veolia Patrick Waterfield JCP Consulting Pre Assessment New Construction (Fully fitted) 8000 No Option not applicable to building type Yes Building Details Section 1 Page 1

2 BREEAM UK New Construction 2014 Pre Assessment Estimator: Assessment Issue Scoring MANAGEMENT Building name Rye House Energy from Waste Plant Building score (%) 79,80% Building rating Excellent Minimum standards level achieved Outstanding level Man 01 Project brief and design No. of BREEAM credits available 4 Available contribution to overall score 2,29% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will stakeholder consultation (project delivery) take place? Will stakeholder consultation (third party) take place? Will a sustainability champion (design) be assigned? Will a sustainability champion (monitoring progress) be assigned? Total BREEAM credits achieved 4 Total contribution to overall building score 2,29% 0 Full consultation credits including Sustainability Champion (contractor/client) Consultation RIBA Stage 2 Sustainability Champion (Design) to be appointed during RIBA Stage 1 Sustainability Champion (Monitoring Progress) to be appointed during RIBA Stage 2 Building Performance by Assessment Issue Section 3 Page 2

3 Man 02 Life cycle cost and service life planning No. of BREEAM credits available 4 Available contribution to overall score 2,29% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will an elemental life cycle cost (LCC)analyses be carried out? Yes 2 2 Will a component level LCC plan be developed? No 1 0 Will the predicted capital cost be reported? Expected capital cost of the project (if available) /m 2 Total BREEAM credits achieved 3 Total contribution to overall building score 1,71% Elemental and component level LCC assumed Capital cost reporting assumed (QS) RIBA Stage 2 Building Performance by Assessment Issue Section 3 Page 3

4 Man 03 Responsible construction practices No. of BREEAM credits available 6 Available contribution to overall score 3,43% No. of BREEAM innovation credits available 1 Minimum standards applicable Yes Is all site timber used in the project 'legally harvested and traded timber'? Yes Will/does the principal contractor operate a compliant Environmental Management System? Will a construction stage sustainability champion be assigned? Will a considerate construction scheme be used by the principal contractor? (One credit where compliance has been achieved. Two credits where compliance is significantly exceeded.) Will construction site impacts be metered/monitored? Will site utility consumption be metered/monitored? Will transport of construction materials and waste be metered/monitored? Will exemplary level criteria be met? Yes Key Performance Indicators: Construction site energy use Energy consumption (total) site processes INA Information not available at design stage Energy consumption (intensity) site processes INA Information not available at design stage Distance (total) materials transport to site INA Information not available at design stage Distance (total) waste transport from site INA Information not available at design stage Energy consumption (total) materials transport to site INA Information not available at design stage Energy consumption (total) waste transport from site INA Information not available at design stage Energy consumption (intensity) materials transport to site INA Information not available at design stage Energy consumption (intensity) waste transport from site INA Information not available at design stage Key Performance Indicators: Construction site greenhouse gas emissions Process greenhouse gas emissions (total) site processes INA Information not available at design stage Greenhouse gas emissions (intensity) site processes INA Information not available at design stage Greenhouse gas emissions (total) materials transport to site INA Information not available at design stage Greenhouse gas emissions (total) waste transport from site INA Information not available at design stage Greenhouse gas emissions (intensity) materials transport to site INA Information not available at design stage Greenhouse gas emissions (intensity) waste transport from site INA Information not available at design stage Key Performance Indicators: Construction site use of freshwater resources Use of freshwater resource (total) site processes INA Information not available at design stage Use of freshwater resource (intensity) site processes INA Information not available at design stage Total BREEAM credits achieved 6 Total contribution to overall building score 3,43% 1 Outstanding level Building Performance by Assessment Issue Section 3 Page 4

5 Credits assumed including exemplary and Sustainability Champion (contractor) Min req for Excellent 1 credit Building Performance by Assessment Issue Section 3 Page 5

6 Man 04 Commisioning and handover No. of BREEAM credits available 4 Available contribution to overall score 2,29% No. of BREEAM innovation credits available 0 Minimum standards applicable Yes Will commissioning schedule and responsibilities be developed & accounted for? Will a commissioning manager be appointed? Will the building fabric be commissioned? Will a training schedule for building occupiers/managers at Handover? Yes Will a building user guide be developed prior to handover? Yes 1 1 Total BREEAM credits achieved 4 Total contribution to overall building score 2,29% All commissioning/handover credits assumed (M+E, Archt, contractor) Min req for Excellent Building User Guide Outstanding level Building Performance by Assessment Issue Section 3 Page 6

7 Man 05 Aftercare No. of BREEAM credits available 3 Available contribution to overall score 1,71% No. of BREEAM innovation credits available 1 Minimum standards applicable Yes Will aftercare support be provided to building occupiers? Will seasonal commissioning occur over 12months once substantially occupied? Will a post occupancy evaluation be carried out 1 year after occupation? No 1 0 Will exemplary level criteria be met? No 1 0 Total BREEAM credits achieved 2 Total contribution to overall building score 1,14% 0 Outstanding level Aftercare support and seasonal commissioning assumed during normal defects liability period (M+E, archt, contractor) Post occupancy evaluation not assumed nor exemplary level (requires 3 years seasonal commissioning, targets and feedback to BRE, occupants, design team) Min req for Excellent 1 credit (seasonal commissioning) Building Performance by Assessment Issue Section 3 Page 7

8 HEALTH & WELLBEING Hea 01 Visual Comfort No. of BREEAM credits available 4 Available contribution to overall score 3,33% No. of BREEAM innovation credits available 1 Minimum standards applicable No Will the design provide adequate glare control for building users? Will relevant building areas be designed to achieve appropriate daylight factor(s)? Will the design provide adequate view out for building users? Will internal/external lighting levels, zoning and controls be specified in accordance with the relevant CIBSE Guides/British Standards? Will exemplary level criteria be met? No 1 0 Total BREEAM credits achieved 3 Total contribution to overall building score 2,50% 0 Glare, View Out and lighting levels/controls assumed but not daylight factors (archt, M+E) Daylight factor credit(s) may be available requires daylighting study Building Performance by Assessment Issue Section 3 Page 8

9 Hea 02 Indoor Air Quality No. of BREEAM credits available 5 Available contribution to overall score 4,17% No. of BREEAM innovation credits available 2 Minimum standards applicable No Will an air quality plan be produced and building designed to minimise air pollution? Will building be designed to minimise the concentration and recirculation of pollutants in the building? Will the relevant products be specified to meet the VOC testing and emission levels required? Will formaldehyde and total VOC levels be measured post construction? Will the building be designed to, or have the potential to provide, natural ventilation? Will exemplary level VOCs (products)criteria be met? Key Performance Indicators: Indoor air quality Concentration levels of formaldehyde INA Information not available at design stage Total volatile organic compound (TVOC) concentration INA Information not available at design stage Total BREEAM credits achieved 5 Total contribution to overall building score 4,17% 2 IAQ plan, recirculation minimisation, VOC spec/testing and natvent potential assumed (archt, M+E) Additional exemplary credits for testing of very low VOC/formldehyde levels assumed (contractor) Building Performance by Assessment Issue Section 3 Page 9

10 Hea 03 Safe containment in laboratories No. of BREEAM credits available 1 Available contribution to overall score 0,83% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will an objective risk assessment of proposed laboratory facilities' design be completed? Will the manufacture & installation of fume cupboards and containment devices meet best practice standards? Will containment level 2 & 3 labs meet best practice safety & performance criteria? Yes 0 0 Total BREEAM credits achieved 1 Total contribution to overall building score 0,83% Lab study and fume cupboard design credits assumed (contractor, M+E) Building Performance by Assessment Issue Section 3 Page 10

11 Hea 04 Thermal comfort No. of BREEAM credits available 3 Available contribution to overall score 2,50% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will thermal modelling of the design be carried out? Will the building design be adapted for a projected climate change scenario? Will the modelling inform the development of a thermal zoning and control strategy? Key Performance Indicators: Thermal comfort Predicted Mean Vote (PMV) Predicted Percentage Dissatisfied (PPD) Total BREEAM credits achieved 3 Total contribution to overall building score 2,50% Full thermal modelling and climate change scenario assumed (M+E) Building Performance by Assessment Issue Section 3 Page 11

12 Hea 05 Acoustic Performance No. of BREEAM credits available 3 Available contribution to overall score 2,50% No. of BREEAM innovation credits available 0 Minimum standards applicable No Assessment Criteria Credits Credits available Credits achieved Will the building meet the appropriate acoustic performance standards and testing requirements for: a. Sound insulation b. Indoor ambient noise level c. Reverberation times? Total BREEAM credits achieved 3 Total contribution to overall building score 2,50% Assumes acoustic report and testing confirming all 3 credits (Suitably Qualified Acoustician) Building Performance by Assessment Issue Section 3 Page 12

13 Hea 06 Safety and Security No. of BREEAM credits available 2 Available contribution to overall score 1,67% No. of BREEAM innovation credits available 0 Minimum standards applicable No Where external site areas are present, will safe access be designed for pedestrians and cyclists? Will a suitably qualified security consultant be appointed and security considerations accounted for? Total BREEAM credits achieved 2 Total contribution to overall building score 1,67% Security consultant and pedestrian/cyclist safety assumed (Suitably Qualified Security Specialist/Archt) RIBA Stage 2 for second credit (Security consultation) Building Performance by Assessment Issue Section 3 Page 13

14 ENERGY Ene 01 Reduction of energy use and carbon emissions No. of BREEAM credits available 12 Available contribution to overall score 7,83% No. of BREEAM innovation credits available 5 Minimum standards applicable Yes How do you wish to assess the number of BREEAM credits achieved for this issue? Select the target number of BREEAM credits for the Ene01 issue: Define a target number of BREEAM credits achieved 8 BREEAM Ene01 Innovation credits: Ene 01 Calculator Country of the UK where the building is located England Confirm building regulation and version to be used: New Construction (Fully fitted) Building floor area 8500 m2 Improvement Factor Notional building heating and cooling energy demand MJ/m2yr Actual building heating and cooling energy demand MJ/m2yr Notional building primary energy consumption kwh/m2yr Actual building primary energy consumption kwh/m2yr Target emission rate (TER) kgco2/m2yr Building emission rate (BER) kgco2/m2yr Building emission rate improvement over TER 0,0% Heating & cooling demand energy performance ratio (EPR ED ) 0,000 0,000 Primary consumption energy performance ratio (EPR PC ) 0,000 0,000 CO 2 Energy performance ratio (EPR CO2 ) 0,000 0,000 Overall building energy performance ratio (EPR NC ) 0,000 0,000 Number of BREEAM credits achieved 0 0 Where specified, please confirm the energy production from onsite or near site energy generation technologies Equivalent % of the building's regulated energy consumption generated by carbon neutral sources and used to meet energy demand from unregulated building systems or processes? Is the building designed to be 'carbon negative'? If the building is defined as 'carbon negative' what is the total (modelled) renewable/carbon neutral energy generated and exported? Total BREEAM credits achieved 8 Total contribution to overall building score 5,22% 0 Outstanding level Building Performance by Assessment Issue Section 3 Page 14

15 8 credits assumed (based on waste heat availability and specification of PV) (M+E) Needs confirmation via SBEM Min req for Excellent 5 credits Building Performance by Assessment Issue Section 3 Page 15

16 Ene 02 Energy monitoring No. of BREEAM credits available 2 Available contribution to overall score 1,30% No. of BREEAM innovation credits available 0 Minimum standards applicable Yes Assessment criteria Compliant? Credits available Credits achieved Will a BMS or sub meters be specified to monitor energy use from major building services systems? Will a BMS or sub meters be specified to monitor energy use by tenant/building function areas? Full sub metering credits assumed (M+E) Min req for Excellent 1 credit (first submetering) Total BREEAM credits achieved 2 Total contribution to overall building score 1,30% Outstanding level Building Performance by Assessment Issue Section 3 Page 16

17 Ene 03 External lighting No. of BREEAM credits available 1 Available contribution to overall score 0,65% No. of BREEAM innovation credits available 0 Minimum standards applicable No Assessment criteria Compliant? Credits available Credits achieved Will external light fittings and controls be specified in accordance with the BREEAM criteria? Total BREEAM credits achieved 1 Total contribution to overall building score 0,65% Compliant external lighting/controls assumed (M+E) Building Performance by Assessment Issue Section 3 Page 17

18 Ene 04 Low carbon design No. of BREEAM credits available 3 Available contribution to overall score 1,96% No. of BREEAM innovation credits available 0 Minimum standards applicable No Assessment criteria Compliant? Credits available Credits achieved Will passive design measures be used in line with an analysis be carried out during concept design stage (RIBA stage 2 or equivalent)? Will free cooling measures be implemented in the whole building in line with the passive design analysis? Will a LZC technology be specified in line with a feasibility study carried out by the completion of the Concept Design stage (RIBA Stage 2 or equivalent)? No 1 0 KPI Low and/or zero carbon energy generation Total on site and/or near site LZC energy generation INA kwh/yr Total BREEAM credits achieved 2 Total contribution to overall building score 1,30% Passive design study assumed and LZC (waste heat and PV) but not free cooling (M+E) NB Requires Hea04 1st credit LZC Study required RIBA Stage 2 Building Performance by Assessment Issue Section 3 Page 18

19 Ene 05 Energy efficient cold storage Assessment issue not applicable No. of BREEAM credits available Available contribution to overall score No. of BREEAM innovation credits available Minimum standards applicable Assessment criteria Compliant? Credits available Credits achieved Will the refrigeration system be designed, installed & commissioned in accrodance with BREEAM criteria? Will the refrigeration system demonstrate a saving in indirect greenhouse gas emissions? Total BREEAM credits achieved Total contribution to overall building score Building Performance by Assessment Issue Section 3 Page 19

20 Ene 06 Energy efficient transportation systems No. of BREEAM credits available 3 Available contribution to overall score 1,96% No. of BREEAM innovation credits available 0 Minimum standards applicable Assessment criteria Compliant? Credits available Credits achieved Will a transportation system analysis be carried out to determine and specify the optimum number, size and type of lifts that is most energy efficient? Compliant lift analysis and spec assumed (archt) Will the relevant energy efficient features criteria be met? Total BREEAM credits achieved 3 Total contribution to overall building score 1,96% Yes 2 2 Building Performance by Assessment Issue Section 3 Page 20

21 Ene 07 Energy efficient laboratory systems Assessment issue not applicable No. of BREEAM credits available Available contribution to overall score No. of BREEAM innovation credits available Minimum standards applicable Assessment criteria Compliant? Credits available Credits achieved Pre requisite: Criterion 1 of Hea 03 risk assessment of laboratory facilities Have the occupants' laboratory requirements & performance criteria been confirmed during the preparation of the initial project brief to minimise energy demand? Yes Yes 0 0 Best Practice Energy Practices in Laboratories (table 27) Yes 0 Will the laboratory meet criteria item b) Fan power? Will the laboratory criteria item c) Fume cupboard volume flow rates? Will the lab meet item d) Grouping / isolation of high filtration/ventilation activities? Will the laboratory meet criteria item e) Energy recovery heat? Will the laboratory meet criteria item f) Energy recovery cooling? Will the laboratory meet criteria item g) Grouping of cooling loads? Will the laboratory meet criteria item h) Free cooling? Will the laboratory meet criteria item i) Load responsiveness? Will the laboratory meet criteria item j) Cleanrooms? Will the laboratory meet criteria item k) Diversity? Will the laboratory meet criteria item l) Room air change rates? Total BREEAM credits achieved Total contribution to overall building score Building Performance by Assessment Issue Section 3 Page 21

22 Ene 08 Energy efficient equipment No. of BREEAM credits available 2 Available contribution to overall score 1,30% No. of BREEAM innovation credits available 0 Minimum standards applicable No Assessment criteria Which of the following will be present and likely to be a/the major contributor to 'unregulated' energy use? Present Major impact Ref A Small power and plug in equipment? Yes Yes Ref B Swimming pool? No No Ref C Communal laundry? No Ref D Data centre? Yes Yes Ref E IT intensive operation areas? No Select Ref F Residential areas? No Ref G Healthcare? No Ref H Kitchen and catering facilities? No Will the significant majority contributor(s) to 'unregulated' energy use above meet the BREEAM criteria? Compliant Credits available Credits achieved Yes 2 2 Total BREEAM credits achieved 2 Total contribution to overall building score 1,30% Significant unregulated energy uses assumed to comply (M+E, contractor/client) Building Performance by Assessment Issue Section 3 Page 22

23 Ene 09 Drying space Assessment issue not applicable No. of BREEAM credits available Available contribution to overall score No. of BREEAM innovation credits available Minimum standards applicable Assessment criteria Compliant? Credits available Credits achieved Will internal/external drying space and fixings be provided? 0 Total BREEAM credits achieved Total contribution to overall building score Building Performance by Assessment Issue Section 3 Page 23

24 TRANSPORT Tra 01 Public Transport Accessibility No. of BREEAM credits available 3 Available contribution to overall score 3,00% No. of BREEAM innovation credits available 0 Minimum standards applicable No Building type category (for purpose of Tra01 issue assessment) Other Building Type 1 Assessment Criteria Compliant Credits available Credits achieved Indicative public transport accessibility index (AI): 0, Will the building have a dedicated bus service? No 0 AI Indicative Accessibility Index for pre assessment Poor or no public transport provision A single BREEAM compliant public transport node available Some BREEAM compliant public transport nodes/services available A selection of BREEAM compliant public transport nodes/services available Good provision of public transport i.e. small urban centre / suburban area Very Good provision of public transport i.e. small/medium urban centre Excellent provision of public transport, i.e. medium urban centre Excellent provision of public transport, i.e. large urban/metropolitan city centre Total BREEAM credits achieved 0 Total contribution to overall building score 0,00% No public transport nodes nor dedicated bus service assumed Building Performance by Assessment Issue Section 3 Page 24

25 Tra 02 Proximity to Amenities No. of BREEAM credits available 1 Available contribution to overall score 1,00% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will the building be in close proximity of and accessible to applicable amenities? No 1 0 No nearby amenities assumed Total BREEAM credits achieved 0 Total contribution to overall building score 0,00% Building Performance by Assessment Issue Section 3 Page 25

26 Tra 03 Cyclist facilities No. of BREEAM credits available 2 Available contribution to overall score 2,00% No. of BREEAM innovation credits available 0 Minimum standards applicable No Building type category (for purpose of Tra03 issue assessment) Other Building transport type 1 How many compliant cycle storage spaces will be provided? 10 What cyclist facilities will be provided? Changing facilities and lockers and drying space compliant cyclist facilities assumed Cycle storage spaces Cyclist facilities Total BREEAM credits achieved 2 Total contribution to overall building score 2,00% Yes Yes Building Performance by Assessment Issue Section 3 Page 26

27 Tra 04 Maximum Car Parking Capacity No. of BREEAM credits available 2 Available contribution to overall score 2,00% No. of BREEAM innovation credits available 0 Minimum standards applicable No Building type category (for purpose of Tra04 issue) Other Building transport type 1 Building's indicative Accessibility Index (sourced from issue Tra01) 0 Will BREEAM's maximum parking capacity criteria for the building type/accessibility Index be met? Total BREEAM credits achieved 0 Total contribution to overall building score 0,00% Carparking assumed above minimum requirement (ie no credits) No 2 0 Building Performance by Assessment Issue Section 3 Page 27

28 Tra 05 Travel Plan No. of BREEAM credits available 1 Available contribution to overall score 1,00% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will a transport plan based on site specific travel survey/assessment be developed? Full travel plan assumed (archt) Total BREEAM credits achieved 1 Total contribution to overall building score 1,00% Building Performance by Assessment Issue Section 3 Page 28

29 WATER Wat 01 Water Consumption No. of BREEAM credits available 5 Available contribution to overall score 3,89% No. of BREEAM innovation credits available 1 Minimum standards applicable Yes How do you wish to assess the number of BREEAM credits to be achieved for this issue? Define a target % improvement over baseline sanitary fittings What is the target for % reduction in potable water consumption for sanitary use in the building? 40% three credits Please select the calculation procedure used Standard approach No Standard approach data Water Consumption from building micro components L/person/day Water demand met via greywater/rainwater sources L/person/day Total net water consumption L/person/day Improvement on baseline performance % Key Performance Indicator use of freshwater resource Total net Water Consumption Default building occupancy m3/person/yr Alternative approach data Please select: Overall microcomponent performance level achieved Water efficient sanitary appliances assumed (M+E) Min req for Excellent 1 credit Total BREEAM credits achieved 3 Total contribution to overall building score 2,33% 0 Outstanding level Building Performance by Assessment Issue Section 3 Page 29

30 Wat 02 Water Monitoring No. of BREEAM credits available 1 Available contribution to overall score 0,78% No. of BREEAM innovation credits available 0 Minimum standards applicable Yes Will there be a water meter on the mains water supply to the building(s)? Will metering/monitoring equipment be specified on the water supply to any relevant plant/building areas? Yes Will all specified water meters have a pulsed output? If the site/building has an existing BMS connection, will all pulsed meters be connected to the BMS? Full water metering assumed (M+E) Min req for Excellent water meter Total BREEAM credits achieved 1 Total contribution to overall building score 0,78% Outstanding level Yes Building Performance by Assessment Issue Section 3 Page 30

31 Wat 03 Water Leak Detection and Prevention No. of BREEAM credits available 2 Available contribution to overall score 1,56% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will a mains water leak detection system be installed on the building's mains water supply? Will flow control devices be installed in each sanitary area/facility? Total BREEAM credits achieved 2 Total contribution to overall building score 1,56% Compliant leak detection and shut off valves assumed (M+E) Building Performance by Assessment Issue Section 3 Page 31

32 Wat 04 Water Efficient Equipment No. of BREEAM credits available 1 Available contribution to overall score 0,78% No. of BREEAM innovation credits available No Minimum standards applicable No Has a meaningful reduction in unregulated water demand been achieved? Total BREEAM credits achieved 1 Total contribution to overall building score 0,78% Water efficient vehicle wash assumed (and no landscape irrigation) (contractor, M+E) Building Performance by Assessment Issue Section 3 Page 32

33 MATERIALS Mat 01 Life Cycle Impacts 6 No. of BREEAM credits available 2 Available contribution to overall score 2,70% No. of BREEAM innovation credits available 3 Minimum standards applicable No How do you wish to assess the number of BREEAM credits to be achieved for this issue? Assessment Criteria Predicted total Mat01 credits achieved 2 Predicted total Mat01 points achieved Number of building elements assessed Green Guide exemplary level compliant? No Has IMPACT compliant software been used? No Define the number of Mat 01 credits achieved Key Performance Indicator embodied green house gas emissions by element External walls Windows Roof Upper floor construction Internal wall Floor finishes/coverings Total area of element m 2 Total impact kgco 2 eq. Area of element impact data relevant to m 2 Key Performance Indicator embodied green house gas emissions for building (assessed elements only) Total embodied green house gas emissions for building (by assessed elements) Missing data kgco 2 eq. kgco 2 eq./m 2 Proportion of applicable building elements that data reported covers Total BREEAM credits achieved 2 Total contribution to overall building score 2,70% 0 Max credits assumed for Green Guide ratings (archt, civ eng, contractor) Possible additional exemplary credits available depending on construction elements Building Performance by Assessment Issue Section 3 Page 33

34 Mat 02 Hard Landscaping and Boundary Protection No. of BREEAM credits available 1 Available contribution to overall score 1,35% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will 80% of all external hard landscaping and boundary protection achieve a Green Guide A or A+ rating? Not assumed Total BREEAM credits achieved 0 Total contribution to overall building score 0,00% No 1 0 Building Performance by Assessment Issue Section 3 Page 34

35 Mat 03 Responsible Sourcing No. of BREEAM credits available 4 Available contribution to overall score 5,40% No. of BREEAM innovation credits available 1 Minimum standards applicable Yes Assessment Criteria Compliant Credits available Credits achieved All timber and timber based products are 'Legally harvested and trader timber' Yes Is there a documented sustainable procurement plan? Percentage of available responsible sourcing of materials points achieved 20,00% 3 1 Please confirm the route used to assess Mat03 Route 2: Proportion of materials responsibly sourced Total BREEAM credits achieved 2 Total contribution to overall building score 2,70% 0 Outstanding level Legally sourced timber, Sustainable procurement plan (1 credit) and 1 of 3 responsible sourcing credits assumed (contractor) Min req for Excellent legally sourced timber Building Performance by Assessment Issue Section 3 Page 35

36 Mat 04 Insulation No. of BREEAM credits available 1 Available contribution to overall score 1,35% No. of BREEAM innovation credits available 0 Minimum standards applicable No Assessment Criteria Credits available Credits achieved What is the building's targeted insulating index? 2, Note: An insulatio Total BREEAM credits achieved 1 Total contribution to overall building score 1,35% Compliant insulation assumed (archt, M+E, contractor) Building Performance by Assessment Issue Section 3 Page 36

37 Mat 05 Designing for durability and resilience No. of BREEAM credits available 1 Available contribution to overall score 1,35% No. of BREEAM innovation credits available 0 Minimum standards applicable Will suitable durability/protection measures be specified and installed to vulnerable areas of the building? Will suitable durability/protection measures be specified and installed to exposed parts of the building? Compliant durability measures assumed (archt) Total BREEAM credits achieved 1 Total contribution to overall building score 1,35% Yes Yes 1 1 Building Performance by Assessment Issue Section 3 Page 37

38 Mat 06 Material efficiency No. of BREEAM credits available 1 Available contribution to overall score 1,35% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will material efficiency measures be identified & implemented during all RIBA stages? Compliance assumed (archt) Total BREEAM credits achieved 1 Total contribution to overall building score 1,35% Building Performance by Assessment Issue Section 3 Page 38

39 WASTE Wst 01 Construction Waste Management No. of BREEAM credits available 4 Available contribution to overall score 4,25% No. of BREEAM innovation credits available 1 Minimum standards applicable Yes How do you wish to assess the number of BREEAM credits to be achieved for this issue? Select the number of BREEAM credits being targeted for issue Wst 01: Define a target number of BREEAM credits 2 BREEAM Wst01 Innovation credits: 0 Assessment Criteria Construction resource management plan Compliant Pre demolition audit Does the excavation waste meet the exemplary level requirements? Compliant? Key Performance Indicators Construction Waste Measure/units for the data being reported Non hazardous construction waste (excluding demolition/excavation) FALSE Total non hazardous construction waste generated INA FALSE Note: At the pre assessment stage this f Non hazardous non demolition const. waste diverted from landfill % Note: At this stage this will be a target b Total non hazardous non demolition const. waste diverted from landfill INA FALSE Note: At the pre assessment stage this f Total non hazardous demolition waste generated FALSE Note: At this stage this will be a target b Non hazardous demolition waste diverted from landfill % Note: At this stage this will be a target b Total non hazardous demolition waste to disposal INA FALSE Note: At the pre assessment stage this f Material for reuse FALSE Note: At this stage this will be a target b Material for recycling FALSE Note: At this stage this will be a target b Material for energy recovery FALSE Note: At this stage this will be a target b Hazardous waste to disposal FALSE Note: At this stage this will be a target b Total BREEAM credits achieved 2 Total contribution to overall building score 2,13% 0 Outstanding level 2 of 4 credits assumed for reduction of waste and diversion from landfill (contractor) Building Performance by Assessment Issue Section 3 Page 39

40 Wst 02 Recycled Aggregates No. of BREEAM credits available 1 Available contribution to overall score 1,06% No. of BREEAM innovation credits available 1 Minimum standards applicable No Assessment Criteria What is the target total % of high grade aggregate that will be recycled/secondary aggregate? Total 0% % of high grade aggregate that is recycled/secondary aggregate by application Not assumed Structural frame Bitumen/hydraulically bound base, binder and surface courses Building foundations Concrete road surfaces Pipe bedding Granular fill and capping Total BREEAM credits achieved 0 0 Total contribution to overall building score 0,00% 0 0 Building Performance by Assessment Issue Section 3 Page 40

41 Wst 03 Operational Waste No. of BREEAM credits available 1 Available contribution to overall score 1,06% No. of BREEAM innovation credits available 0 Minimum standards applicable Yes Will operational recyclable waste volumes be segregated and stored? Will static waste compactor(s) or baler(s) be specified where appropriate? Yes Will vessel(s) for composting suitable organic waste where appropriate? Yes Full credits assumed (contractor/client) Min req for Excellent 1 credit Total BREEAM credits achieved 1 Total contribution to overall building score 1,06% Outstanding level Building Performance by Assessment Issue Section 3 Page 41

42 Wst 04 Speculative Floor and Ceiling Finishes Assessment issue not applicable No. of BREEAM credits available Available contribution to overall score No. of BREEAM innovation credits available Minimum standards applicable No 0 Total BREEAM credits achieved Total contribution to overall building score Building Performance by Assessment Issue Section 3 Page 42

43 Wst 05 Adaption to climate change No. of BREEAM credits available 1 Available contribution to overall score 1,06% No. of BREEAM innovation credits available 1 Minimum standards applicable Will a climate change adaptation strategy appraisal for structural and fabric resilience be conducted by the end of Concept Design (RIBA Stage 2 or equivalent)? Will emexplary level criteria Responding to adaptation to climate change be met? Design stage study assumed (archt) RIBA Stage 2 Total BREEAM credits achieved 1 Total contribution to overall building score 1,06% 1 Building Performance by Assessment Issue Section 3 Page 43

44 Wst 06 Functional adaptability No. of BREEAM credits available 1 Available contribution to overall score 1,06% No. of BREEAM innovation credits available 0 Minimum standards applicable Will a building specific functional adaptation strategy appraisal be conducted by Concept Design (RIBA Stage 2 or equivalent) and will functional adaptation measures be implemented? Design stage study assumed (archt) RIBA Stage 2 Total BREEAM credits achieved 1 Total contribution to overall building score 1,06% Building Performance by Assessment Issue Section 3 Page 44

45 LAND USE & ECOLOGY LE 01 Site Selection No. of BREEAM credits available 2 Available contribution to overall score 2,00% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will at least 75% of the proposed development s footprint be located on previously occupied land? Is the site deemed to be significantly contaminated? Total BREEAM credits achieved 2 Total contribution to overall building score 2,00% Credits assumed (Suitably Qualified Ecologist) Building Performance by Assessment Issue Section 3 Page 45

46 LE 02 Ecological Value of Site and Protection of Ecological Features No. of BREEAM credits available 2 Available contribution to overall score 2,00% No. of BREEAM innovation credits available 0 Minimum standards applicable No Ecological value of the land defined using A Suitably Qualified Ecologist Can the land within the construction zone be defined as land of low ecological value? Will all features of ecological value surrounding the construction zone/site boundary be protected? Total BREEAM credits achieved 2 Total contribution to overall building score 2,00% Protection of any ecological features assumed (Suitably Qualified Ecologist/contractor) Building Performance by Assessment Issue Section 3 Page 46

47 LE 03 Mitigating Ecological Impact No. of BREEAM credits available 2 Available contribution to overall score 2,00% No. of BREEAM innovation credits available 0 Minimum standards applicable Yes Data sourced for calculating the change in ecological value from Suitably Qualified Ecologist site survey of plant species Assessment Criteria What is the likely change in ecological value as a result of the sites development? Total BREEAM credits achieved 2 Total contribution to overall building score 2,00% No negative change assumed (Suitably Qualified Ecologist/contractor) Min req for Excellent 1 credit Outstanding level 0 species (i.e. no negative change) Plant species richn Building Performance by Assessment Issue Section 3 Page 47

48 LE 04 Enhancing Site Ecology No. of BREEAM credits available 2 Available contribution to overall score 2,00% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will a suitably qualified ecologist be appointed to report on enhancing and protecting site ecology? Yes 2 2 Will the suitably qualified ecologist's general recommendations be implemented? Yes What is the targeted/intended improvement in ecological value as a result of enhancement actions? 6 species (large positive change) Plant species richn Total BREEAM credits achieved 2 Total contribution to overall building score 2,00% Large +ve change assumed (Suitably Qualified Ecologist/contractor) SQE appointed RIBA Stage 1 Report produced RIBA Stage 2 Building Performance by Assessment Issue Section 3 Page 48

49 LE 05 Long Term Impact on Biodiversity No. of BREEAM credits available 2 Available contribution to overall score 2,00% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will a Suitably Qualified Ecologist be appointed to monitor/minimise impacts of site activities on biodiversity? Will a landscape and habitat management plan be produced covering at least the first five years after project completion in accordance with British Standards? Number of applicable measures to improve biodiversity confirmed by SQE: Number of applicable measures implemented: Total BREEAM credits achieved 2 Total contribution to overall building score 2,00% Assumed (Suitably Qualified Ecologist/contractor/client) Yes 2 2 Yes 6 4 Building Performance by Assessment Issue Section 3 Page 49

50 POLLUTION Pol 01 Impact of Refrigerants No. of BREEAM credits available 3 Available contribution to overall score 2,50% No. of BREEAM innovation credits available 0 Minimum standards applicable No Assessment Criteria Credits available Credits achieved Refrigerant containing systems installed in the assessed building? Yes 2 0 Do all systems (with electric compressors) comply with the requirements of BS EN 378:2008 (parts 2 & 3) & where refrigeration systems containing ammonia are installed, the IoR Ammonia Refrigeration Systems Code of Practice? Yes Global Warming Potential of the specified refrigerant(s) 10 or less? What is the target range Direct Effect Life Cycle CO2eq. emissions for the system? No INA kgco2eq/kw coolth capacity Cooling/Heating capacity of the system INA kw Will a refrigerant leak detection and containment system be specified/installed? Total BREEAM credits achieved 1 Total contribution to overall building score 0,83% Refrigerant leak detection assumed but not compliant refrigerants (M+E) Building Performance by Assessment Issue Section 3 Page 50

51 Pol 02 NO x Emissions No. of BREEAM credits available 2 Available contribution to overall score 1,67% No. of BREEAM innovation credits available 0 Minimum standards applicable No Assessment Criteria Will office areas be compliant? No NO x emission level space heating 100,00 mg/kwh NO x emission level cooling 100,00 mg/kwh NOx emission level water heating 100,00 mg/kwh Does this building meet BREEAM's definition of a highly insulated building? Energy consumption: heating and hot water INA kwh/m2 yr Total BREEAM credits achieved 0 Total contribution to overall building score 0,00% No credits assumed due to assumption of waste heat utilisation rather than eg gas boiler Building Performance by Assessment Issue Section 3 Page 51

52 Pol 03 Surface Water Run off No. of BREEAM credits available 5 Available contribution to overall score 4,17% No. of BREEAM innovation credits available 0 Minimum standards applicable No What is the actual/likely annual probability of flooding for the assessed site? High Will a Flood Risk Assessment and ground level of the building and access be undertaken? Yes 2 1 Will the site meet the BREEAM criteria for peak rate surface water run off? Will the site meet the criteria for surface water run off volume, attenuation and/or limiting discharge? Will the site be designed to minimise watercourse pollution in accordance with the BREEAM criteria? Total BREEAM credits achieved 4 Total contribution to overall building score 3,33% Full FRA and compliance assumed (4 of 5 credits only achievable due to high flood risk location) (Civ Eng) Building Performance by Assessment Issue Section 3 Page 52

53 Pol 04 Reduction of Night Time Light Pollution No. of BREEAM credits available 1 Available contribution to overall score 0,83% No. of BREEAM innovation credits available 0 Minimum standards applicable No Will the external lighting specification be designed to reduce light pollution? Compliant external lighting/controls assumed (M+E) Total BREEAM credits achieved 1 Total contribution to overall building score 0,83% Building Performance by Assessment Issue Section 3 Page 53

54 Pol 05 Noise Attenuation No. of BREEAM credits available 1 Available contribution to overall score 0,83% No. of BREEAM innovation credits available 0 Minimum standards applicable No Assessment Criteria Compliant Credits available Credits achieved Will there be noise sensitive areas/buildings within 800m radius of the development? Will a noise impact assessment be carried out and, if applicable, noise attenuation measures specified? Total BREEAM credits achieved 1 Total contribution to overall building score 0,83% Acoustic report/testing assumed (Suitably Qualified Acoustician) Yes Building Performance by Assessment Issue Section 3 Page 54

55 INNOVATION Inn 01 Innovation No. of BREEAM innovation credits available 10 Available contribution to overall score 10,00% Minimum standards applicable No Man 03 Responsible construction practices Man 05 Aftercare No 1 0 Hea 01 Visual Comfort No 1 0 Hea 02 Indoor Air Quality Yes 2 2 Ene 01 Reduction of energy use and carbon emissions No 5 0 Wat 01 Water Consumption No 1 0 Mat01 Life Cycle Impacts No 3 0 Mat03 Responsible Sourcing of Materials No 1 0 Wst01 Construction Waste Management No 1 0 Wst02 Recycled Aggregates No 1 0 Wst 05 Adaption to climate change Number of 'approved' innovation credits achieved? See relevant credit headings for details and responsibilities 4 Total contribution to overall building score 4,00% Building Performance by Assessment Issue Section 3 Page 55

56 BREEAM UK New Construction 2014 Pre Assessment Estimator: Indicative Rating & Building Performance Overall Building Performance Building name Rye House Energy from Waste Plant Indicative BREEAM rating Excellent Indicative Total Score 79,8% Min. standards level achieved Outstanding level Building Performance by Environment Section 16% 14% 12% 10% 8% 6% 4% 2% 0% Management Health & Wellbeing Energy Transport Water Materials Waste Land Use & Ecology Pollution Section score available Section score achieved Environmental Section No. credits Indicative no. % credits Section Indicative available credits Achieved achieved Weighting Section Score Management ,5% 12,0% 10,9% Health & Wellbeing ,4% 15,0% 14,2% Energy ,3% 15,0% 11,7% Transport ,3% 9,0% 3,0% Water ,8% 7,0% 5,4% Materials ,0% 13,5% 9,5% Waste ,5% 8,5% 5,3% Land Use & Ecology ,0% 10,0% 10,0% Pollution ,3% 10,0% 5,8% Innovation ,0% 4 Assessment Rating KPIs Section 2 Page 56

57 Assessment Rating KPIs Section 2 Page 57

58 BREEAM UK New Construction 2014 Pre Assessment Estimator: Version Control Version Current Version 2, Previous Versions Release Date Description of changes/additions made to the BREEAM UK NC 2014 Pre Assessment Estimator Tool Added SD5076 Issue 3.0 to the assessment details tab Man 05 Made credits independent of POE Man 05 Unlocked summary box Hea 01 Amended wording in relation to lighting and shell & core/shell only buildings Hea 02 Made credits independent of IAQ Hea 02 Exemplary lever criteria is made not available when VOC emission levels (product) criteria are not met Hea 04 Made whole issue for industrial buildings with no offices Ene 01 The tool was not awarding the minimum standard correctly for buildings modelled using SAP and SBEM. The issue has been fixed Ene 01 Fixed issue calculation for non domestic buildings in Scotland Ene 07 One credit has been made available when the laboratory area accounts for less than 10% of building's Gross Internal Floor Area Ene 08 Fixed scoring when Residential areas are a major contributor to unregulated energy use Tra 03 The drop down list for 'cyclist facilities provided' has been amended and now includes all the options available Pol 02 The credits were awarded by default when cells were empty. The issue has been sorted Innovation table has been amended Assessment Details tab has been amended so that when all mandatory fields are filled in the warning message does not appear anymore 1, First version uploaded to Extranet