1 Contents Architectural Basic Unit Details Single-Hung Basic Unit Details Double-Hung Suggested Product Applications Factory-applied 5-1/4, 6-9/16, 7-1/8 and custom width extension jambs Insect screens Curved interior casings Curved exterior aluminum and wood casings in matching radii and a variety of profiles 14-1

2 Basic Unit Details Aluminum Clad Monumental Springline Single-Hung Basic Unit Scale 3" = 1'-0" (1:4) 3-13/32" (87) CURVED HEAD DETAIL Half insect screen shown 4- rough Opening extension unit Dimension 4-3/16" (106) 6-1/8" (156) 14-2 A r c h i t e c t u r a l D e t a i l F i l e rev.02/08

3 Basic Unit Details Aluminum Clad Monumental Lineal & Archtop Double-Hung Basic Unit Scale 3" = 1'-0" (1:4) 6-1/8" (156) 6-1/8" (156) 1-9/16" (40) 1-9/16" (40) Full insect screen shown, half insect screen available 2-11/32" (60) Full insect screen shown, half insect screen available 2-11/32" (60) LINEAL HEAD DETAIL CURVED HEAD DETAIL 4-4- rough Opening extension jambs unit Dimension 4-3/16" (106) 6-1/8" (156) 14-3

4 Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) all at head 1/2" (13)* minimum all Wood Siding / 2 x 4 Wood Stud Framing *1/2" (13) minimum to accommodate differential shrinkage/expansion when brick is applied to wood framing. Brick Veneer / 2 x 6" Metal Stud Framing Importance of Proper Proper and maintenance of products are essential if optimum performance is to be fully attained. Written instructions which provide guidelines for proper are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN or by visiting our website at Remember that every is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the of any Andersen product. of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer. Construction by Others Andersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others. all 14-4 Membrane flashing over (by others) E.I.F.S. / Concrete Masonry Unit (CMU) NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint the perimeter of the window. NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. may be removed where construction sequence/ detailing requires no. A r c h i t e c t u r a l D e t a i l F i l e rev.02/08

5 Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) at head Trim s at head and jambs vinyl trim board Existing frame wall at sill & side jambs Brick / Concrete Masonry Unit (CMU) at sill Stucco / Concrete Masonry Unit (CMU) Inset Window all Existing Stud Wall vinyl trim board. Trim to fit as required. Finish trimmed edge with rigid vinyl channel Existing masonry wall Importance of Proper Proper and maintenance of products are essential if optimum performance is to be fully attained. Written instructions which provide guidelines for proper are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN or by visiting our website at Remember that every is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the of any Andersen product. of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer. Construction by Others Andersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others. NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint the perimeter of the window. all Existing Masonry Wall NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. may be removed where construction sequence/ detailing requires no. 14-5