INSTALLATION INSTRUCTIONS SUPERPLANE 4. Mud-In. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Size: px
Start display at page:

Download "INSTALLATION INSTRUCTIONS SUPERPLANE 4. Mud-In. A nd Avenue, Unit 1 Oakland, CA P E W alwusa."

Transcription

1 INSTALLATION INSTRUCTIONS SUPERPLANE 4 Mud-In A nd Avenue, Unit 1 Oakland, CA P E TalkToUs@alwusa.com W alwusa.com

2 SP4R - Safety & Warnings! 1. Read all instructions. 2. Install in accordance with national and local electrical code regulations. 3. This product is intended to be installed and serviced by a qualified, licensed electrician. 4. Do not install in wet locations. For dry and damp use only. 5. Turn off electrical power before installing or servicing fixture in any way. 6. To reduce the risk of fire and overheating, make sure all connections are tight. 7. This product is type IC (insulation contact) rated, and suitable for continuous row mounting. 8. Handle ControRoll TM lens with care! Always wear protective eyewear while handling lens! Lens may chip/crack when handled roughly. SP4R - Attention! 1. Lisez toutes les instructions. 2. Installez conformément à la réglementation du code électrique national et local. 3. Ce produit est destiné à être installé et entretenu par un électricien agréé qualifié. 4. Ne pas installer à l extérieur ou dans des endroits humides. Pour une utilisation en intérieur et sec seulement. 5. Coupez l alimentation électrique avant de évoluer le système d éclairage en aucune façon. 6. Pour réduire le risque d incendie et de surchauffe, assurez-vous que toutes les connexions sont bien serrées. 7. Type IC. Pour emplacements secs seulement. Peut être monté en rangée continue. 8. Manipuler l objectif ControlRoll avec soin! Portez toujours des lunettes de protection lors de la manipulation de l objectif ControlRoll. SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. CONTROLROLL LENS HANDLING & SAFETY! ALWAYS WEAR PROTECTIVE EYEWEAR WHILE HANDLING LENS! LENS MAY CHIP/CRACK WHEN HANDLED ROUGHLY! Ø < 3.0 in. DO NOT CREASE LENS DO NOT TWIST LENS DO NOT BEND LENS TO A DIAMETER LESS THAN 3 INCHES. SP4R Mud-In Installation Guide 2 of IG A.0

3 Table of Contents Luminaire Overview 4 Diagram 4 Included Parts 4 Parts (by others) 4 Tools Required 4 Quick Specs 4 Installation 5 Mounting to Structure 5 Joining Straight Sections 6 Joining Mitered Corners 7 Inside Corners 8 Outside Corners 8 Finishing - Mud-In ControllRoll TM Lens Wiring Diagrams Traditional On/Off 0-10V Dimming DMX DALI Lutron LDE Troubleshooting SP4R Mud-In Installation Guide 3 of IG A.0

4 Luminaire Overview Diagram 4 3 4" 5 1 2" Opening in drywall " Distance between framing 9" Included Parts SP4R Fixture ControlRoll TM Lens Diffuser Shim (miters) Joiner kit (lengths > 8ft) Parts (by others) Wood screws 1/4-20 nuts Drywall tape Mud plaster Tools Required Drill #2 phillips bit Drywall cutting tool Mud trowel Wrench Wire strippers 1/8 Allen key Quick Specs Input Voltage / Frequency: See product label Rated Current: See engineering drawing Ambient Temperature: F ( C) Environment: Dry and damp locations SP4R Mud-In Installation Guide 4 of IG A.0

5 Installation: Mounting to Structure 6 1 2"! SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while joining sections or reattaching end caps. 1 Install framing Install framing with in. spacing for fixture. Check blocking for straightness, alignment, and consistent in. spacing along length. For vertical installations, add blocking across opening at bottom end of fixture. 4 Connect wiring Take off end cap window cover and punch knock-out. Make connections per wiring diagram on page 11 and secure conduit to window cover. Re-fasten cover back ensuring not to pinch wires between parts. 2 Raise fixture into blocking Raise fixture to blocking and ensure correct spacing along fixture length. 5 Remove protective film Remove protective film on fixture. You may reuse it after lens is installed to protect fixture from dust, scratches, and other debris until it is commissioned. 3 Screw fixture to blocking Screw fixture to blocking through attached flange. Check fixture for alignment. SP4R Mud-In Installation Guide 5 of IG A.0

6 Installation: Joining Straight Sections If joining straight sections, continue with steps 6-8. If joining miter sections, continue with steps If installing single-section fixtures, go to step 13. 7A Connect brackets Loosen set screws using 1/8 allen key and slide section connectors on one section until they are approximately 1/4 apart.! SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while joining sections or reattaching end caps. 7B Connect brackets Tighten set screws on connector bracket and attach both fixtures with included #8 screws. 6 Connect wiring Connect wiring quick-connects and move joining fixture section into place. 8 Screw fixture to blocking Screw fixture to blocking through attached flange. Check fixture for alignment. SP4R Mud-In Installation Guide 6 of IG A.0

7 Installation: Joining Mitered Corners! SHOCK HAZARD! May result in serious injury or death. Turn power OFF at circuit breaker prior to installation or servicing. DO NOT PINCH OR PUT EXCESSIVE TENSION ON WIRES while joining sections or reattaching end caps. 11 Connect brackets Screw connector brackets on top and sides with provided 8-32 screws avoiding any gaps between fixtures. 9 Connect wiring Connect wiring quick connects between fixtrue sections. 12A Insert diffuser shim Bend provided diffuser shim and insert it into the grooves in side walls of extrusion covering LEDs extending into miter joint. 10 Join miter sections Slide miter sections together and join section connectors. Adjust connectors with set screws as necessary. 12B Insert diffuser shim SP4R Mud-In Installation Guide 7 of IG A.0

8 Installation: Inside Corner Installation: Outside Corner Inside corner Install fixture sections, make connections, and install lenses. Outside corner Install fixture sections, make connections, and install lenses. Inside corner Outside corner Inside corner Outside corner SP4R Mud-In Installation Guide 8 of IG A.0

9 Installation: Mud-In Finishing 1 1 4" 13A Install drywall Install drywall around fixture. Drywall should sit against edge of perforated flange. Screw drywall to blocking. Screws should be drilled approximately 1 1 4" from edge of perforated flange. 15 Apply mud Apply mud with trowel. Once mud dries, sand for a smooth finish. Do not get mud onto lens or inside fixture. 13B Install drywall 16 Paint Finish with paint. Do not get paint onto exposed portions of fixture or lens. 14 Apply mud tape Apply mud tape. SP4R Mud-In Installation Guide 9 of IG A.0

10 Installation: ControlRoll TM Lens 17 Bring lens to fixture Raise ControlRoll lens to fixture. For longer fixture lengths, two people may be needed. Always wear protective eyewear while handling lens. 19A Press lens into lens channel With first edge of lens in lens channel, press other side of lens up toward opposite channel. It may be easier to begin installing lens 2 or more inches from end of fixture. Once inserted, lens can be slid to meet end cap. 18A Pop in ControlRoll TM lens Insert one edge ControlRoll lens into lens channel. 19B Press lens into lens channel Push lens upward until it snaps into second lens channel. 18B Insert ControlRoll lens into lens channel Insert lens into lens channel. 20 Snap lens along fixture Continue pressing both sides of lens into lens channel until lens is fully installed along length of fixture. Press lens into channel at offset positions as shown to limit stress on lens. SP4R Mud-In Installation Guide 10 of IG A.0

11 Wiring Diagrams Traditional On/Off L Hot N Neutral White AC 50/60Hz Green 0-10V Dimming L Hot N Neutral White AC 50/60Hz Green DIM- 0-10V DC Dimming - Grey DIM+ 0-10V DC Dimming + Purple DMX L Hot N Neutral White AC 50/60Hz Green DMX in Shield DMX in - DMX in + DMX in shield DMX in - DMX in + Clear RED DMX out Shield DMX out - DMX out + DMX out shield DMX out - DMX out + Clear White DALI L Hot N Neutral White AC 50/60Hz Green Data + Data - Data + Data - Purple Gray Lutron LDE L Hot N Neutral White AC 50/60Hz Green E2 E2 Gray E1 E1 Purple SP4R Mud-In Installation Guide 11 of IG A.0

12 Troubleshooting Only a certified electrician can service and troubleshoot product field issues. Always turn main power off before servicing fixture. Full Fixture does not illuminate Ensure fixture is wired correctly and power is on. Check that circuit breaker is on and not off or tripped. Internal LED driver may be defective. Ensure no wires are pinched between parts after joining sections or re-attaching end caps. Full fixture is flickering 0-10V, DMX, and DALI Dimming Models: Ensure polarity is correct for DATA + and - connections. Swapping DATA + and - connections can cause flickering. TRIAC Dimming Models: Ensure a compatible TRIAC Forward Phase dimmer is connected to fixture. Call tech support for further information. Possible loose DATA + and - connections from fixture to 0-10V, DMX, or DALI control. Possible loose low voltage DC + or - connection from driver to LED. Call customer support. Fixture section(s) do not illuminate Possible loose low voltage DC + or - connection between LED boards or from LED driver to LED boards. Some fixtures contain multiple LED drivers. In this case, it s possible one of the drivers is defective, which will cause the LED connected to the driver not to illuminate. Call tech support. Ensure no wires are pinched between parts after joining sections or re-attaching end caps. Fixture section(s) are flickering Possible loose low voltage DC + or - connection between LED boards. Fixture does not dim 0-10V, DMX, and DALI Dimming Models: Ensure polarity is correct for DATA + and - connections. Swapping DATA + and - connections can cause flickering. TRIAC Dimming Models: Ensure a compatible TRIAC Forward Phase dimmer is connected to fixture. Call tech support for further information. Possible loose DATA + and - connections from fixture to 0-10V, DMX, or DALI control. SP4R Mud-In Installation Guide 12 of IG A.0