1 Proudly Made in the U.S.A. Surface Mount Tactile

2 Surface Mount Tactile

3 Proudly Made in the U.S.A.

4 Surface Mount Tactile Installation Procedure Be sure to read and understand all of these instructions before you begin. A. The installation area should be cleaned of all debris, oil and grease, making sure the area is completely free of moisture. Tactile Panel may be surface mounted on existing pre-cleaned substrate. B. Lay out the Tactile Panel on the substrate as it will appear when installed. If required, the Tactile Panel may be cut using a table saw and marble tipped blade. See web site for more details. C. Place a /8 bead of adhesive on the frame of the bottom of each Tactile Panel. Adhesive yield: 10SF per 10 ounce cartridge. D. Set the Tactile Panel in the installation area. Make all necessary adjustments prior to fastening. E. Fasteners shall be installed in pre-formed fastener locations. Holes shall be drilled using a hammer drill with 1/ x min SDS bits. The drilled holes must be a minimum of deep. Place fasteners in hole and hammer into place. If additional fasteners are required, use a 1/, six point, 8 degree countersink to add a new fastener location. Follow the same drilling method for installing the fastener. F. Caulk around perimeter of entire installation using BASF NP1 or equivalent. All concrete dust present on the Tactile Panel resulting from the drilling process must be cleaned off of the Tactile Panel prior to using any caulking materials. *Not recommended or warrantied for asphalt installation. PRODUCT SIZES x x x5 x x5 View additional photos, drawings and specifications on our website: Call (800) with any questions. APPLICATION Existing Concrete Ramps

5 DOME GEOMETRY In accordance with ADA Regulations for Detectable Warning on Curb Ramps: Raised truncated domes with a diameter of nominal 0.9, a height of nominal 0., and a centerto-center spacing of nominal 1.67 minimum and.5 maximum. PANEL DIMENSIONS Tactile Panels are available in x6, x8, x60, 6 x8 and 6 x60 sizes and measure /16 thick. Panels can be custom cut to fit field conditions. All four edges of each panel have a ½ beveled edge. Each panel has 1 to pre-formed fastener locations based upon panel size. A homogenous glass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass reinforced for enhanced durability. The Tactile panel color is uniform throughout and does not rely on any type of paint coating to achieve color stability. Standard colors include: Federal Yellow, Brick Red, Clay Red, Safety Red, Blue, Dark Gray and Black. PHYSICAL CHARACTERISTICS Compressive Strength 8,900 psi ASTM D 695 Flexural Strength 9,00 psi ASTM D 790 Water Absorption.07% ASTM D 570 Slip Resistance 1.18 Dry/1.05 Wet ASTM C 108 Flame Spread Index 0 ASTM E 8 Salt Spray No Change (00 hours) ASTM B 117 Chemical Stain Testing No Deterioration ASTM 108 Abrasion Resistance 59 ASTM C 501 Accelerated Weathering Delta E<5.0 (,000 hours) ASTM G 155 Tensile Strength 11,600 psi ASTM D 68 Adhesion to Conc. (0-180 degrees) No Delamination or Degradation ASTM C 90 Freeze/Thaw/Heat No Disintegration ASTM C 106 INSTALLATION ADA Surface Applied TWS Panel (Existing Concrete): TWS panel can be easily installed (adhered, fastened & sealed) in a matter of minutes. INCIDENTALS Fasteners: ¼ x 1⅝, composite sleeve anchor with stainless steel pins. Adhesive: One component structural elastomeric adhesive. Sealant: BASF NP1, Sikaflex 1A, or equivalent. Surface Mount Tactile Inline Dome Pattern 5-Year Warranty Color Throughout 5

6 79 1 Surface Mount Composite Tactile x6 Tile.5 Dome Spacing.0000 R EQUAL SPACES 0.5 WALL THICKNESS EQUAL SPACES 10 R.15 (TYP. 1 LOCATIONS) (TYP. 1 LOCATIONS) VIEW-A x SCALE HALF SCALE PL SIDES DIA. 18-PL. 18-PL DEG POINTS.05 HIGH SECTION X SCALE DOME 60 PL. TILE INSTALLATION VIEW-B x SCALE 1/" x 1 1/" LG. EXPANSION ANCHOR LIST ITEM DESCRIPTION QT'Y SCALE AS NOTED FULL SIZE TRADE DETECTABLE WARNING SURFACE SEE LIST PROJECT SURFACE APPLIED DETECTABLE WARNING SURFACE SYSTEM " x 6" SOUND ATTENUATING CURB RAMP TILE (INLINE DOME) PLANS AND DETAILS DRAWING NO. REV. NO. ADA SOLUTIONS, INC. PO Box N.Billerica, Ma

7 R.150 VIEW-A x SCALE (TYP. 15 LOCATIONS).900 SECTION X SCALE 1-1 EQUAL SPACES EQUAL SPACES WALL THICKNESS 18-PL. DOME 06 PL. R.15 (TYP. 15 LOCATIONS) HALF SCALE SIDES 18-PL.80 DIA. 18-PL DEG POINTS.05 HIGH TILE INSTALLATION VIEW-B x SCALE 1/" x 1 1/" LG. EXPANSION ANCHOR LIST ITEM DESCRIPTION QT'Y SCALE AS NOTED FULL SIZE TRADE DETECTABLE WARNING SURFACE SEE LIST PROJECT SURFACE APPLIED DETECTABLE WARNING SURFACE SYSTEM " x 8" SOUND ATTENUATING CURB RAMP TILE (INLINE DOME) PLANS AND DETAILS DRAWING NO. REV. NO. ADA SOLUTIONS, INC. PO Box N.Billerica, Ma Surface Mount Composite Tactile x8 Tile 1.67 Dome Spacing

8 79 1 Surface Mount Composite Tactile x8 Tile.5 Dome Spacing EQUAL SPACES EQUAL SPACES 10 R.150 WALL THICKNESS R.15 (TYP. 1 LOCATIONS) (TYP. 1 LOCATIONS) VIEW-A x SCALE HALF SCALE PL SIDES DIA. 18-PL. 18-PL.50 SECTION X SCALE.090 DEG POINTS.05 HIGH DOME 60 PL. TILE INSTALLATION VIEW-B x SCALE 1/" x 1 1/" LG. EXPANSION ANCHOR LIST ITEM DESCRIPTION QT'Y SCALE AS NOTED FULL SIZE TRADE DETECTABLE WARNING SURFACE SEE LIST PROJECT SURFACE APPLIED DETECTABLE WARNING SURFACE SYSTEM " x 8" SOUND ATTENUATING CURB RAMP TILE (INLINE DOME) PLANS AND DETAILS DRAWING NO. REV. NO. ADA SOLUTIONS, INC. 1 Survey Circle N.Billerica, Ma

9 79 R SIDES 18-PL DIA. 18-PL. DRAWING NO. REV. NO. ADA SOLUTIONS, INC. P.O. Box N.Billerica, Ma EQUAL SPACES WALL THICKNESS PL. DOME 60 PL. (TYP. 1 LOCATIONS) R VIEW-A x SCALE HALF SCALE SECTION X SCALE.090 DEG POINTS.05 HIGH TILE INSTALLATION VIEW-B x SCALE 1/" x 1 1/" LG. EXPANSION ANCHOR LIST ITEM DESCRIPTION QT'Y SCALE AS NOTED TRADE DETECTABLE WARNING SURFACE SEE LIST PROJECT SURFACE APPLIED DETECTABLE WARNING SURFACE SYSTEM " x 60" SOUND ATTENUATING CURB RAMP TILE (INLINE DOME) PLANS AND DETAILS 1 Surface Mount Composite Tactile x60 Tile.5 Dome Spacing EQUAL SPACES 10 (TYP. 1 LOCATIONS) 9

10 Surface Mount Composite Tactile 6 x8 Tile 1.67 Dome Spacing (TYP. 0 LOCATIONS) HALF SCALE PL DIA. 18-PL DEG POINTS.05 HIGH SECTION X SCALE TILE INSTALLATION VIEW-B x SCALE DOME 68 PL PL. WALL THICKNESS -SIDES EQUAL SPACES R.15 R (TYP. 0 LOCATIONS) 1/" x 1 1/" LG. EXPANSION ANCHOR 1 ITEM SCALE QT'Y REV. NO. SEE LIST AS NOTED FULL SIZE LIST DESCRIPTION TRADE DETECTABLE WARNING SURFACE PROJECT SURFACE APPLIED DETECTABLE WARNING SURFACE SYSTEM 6" x 8" SOUND ATTENUATING CURB RAMP TILE (INLINE DOME) PLANS AND DETAILS DRAWING NO. ADA SOLUTIONS, INC. PO Box N.Billerica, Ma VIEW-A x SCALE 1 - EQUAL SPACES

11 R (TYP. LOCATIONS) -SIDES PL VIEW-A x SCALE EQUAL SPACES 1-1 EQUAL SPACES WALL THICKNESS HALF SCALE DIA. 18-PL PL 79 SECTION X SCALE DEG POINTS.05 HIGH TILE INSTALLATION VIEW-B x SCALE R.15 (TYP. LOCATIONS) 1/" x 1 1/" LG. EXPANSION ANCHOR ADA SOLUTIONS, INC. PO Box N.Billerica, Ma DRAWING NO. QT'Y REV. NO. SEE LIST SURFACE APPLIED DETECTABLE WARNING SURFACE SYSTEM 6" x 60" SOUND ATTENUATING CURB RAMP TILE (INLINE DOME) PLANS AND DETAILS PROJECT AS NOTED FULL SIZE LIST DESCRIPTION TRADE DETECTABLE WARNING SURFACE SCALE 1 ITEM Surface Mount Composite Tactile 6 x60 Tile 1.67 Dome Spacing 11 DOME 79 PL..1975

12 /1