Vijayawada Municipal Corporation

Size: px
Start display at page:

Download "Vijayawada Municipal Corporation"

Transcription

1

2 Vijayawada Municipal Corporation TOWN PLANNING SECTION BUILDING PERMIT ORDER To, Sri/Smt. V.BASAVAIAH, V. MADHUSUDAN & OTHERS, , PATAMATA, krishna FILE No. : 1073/0742/B/VMC/PAT/2016 PERMIT No. : 1073/0742/B/VMC/PAT/2016 DATE : - Sir / Madam, Sub: Building Permission - sanctioned - Reg Ref: Your Application dated: 10 February, 2016 u/s 388, 428 & 433 of HMC Act, 1955 & A.P. Urban Areas (Dev), Act, 1975 and A.P.Building Rules Your application submitted in the reference has been examined with reference to the rules and regulations in force and permission is hereby sanctioned conditionally as detailed below: A APPLICANT AND LICENSED PERSONNEL DETAILS: 1 Applicant V.BASAVAIAH, V. MADHUSUDAN & OTHERS, 2 Developer / Builder 3 Licensed Technical Person 4 Structural Engineer 5 Others B C SITE DETAILS 1 RS/TS No. 2 Premises No Ward 4 Block No. 5 Street 6 Locality PATAMATA 7 Town/ City Vijayawada 2 Use DETAILS OF PERMISSION SANCTIONED Building - PROP (BUILDING) (Height (m): 14.95) Kaushik Kumar T (Architect) Anjaneya Prasad Vattikuti Lic.No. Lic.No. Lic.No. CA/2010/50876 SE 80/14 1 Floors Ground Upper floors Parking floors No. Area (m2) No. Area (m2) Level No. Area (m2) a Residential 1 3, , Cellar b Commercial Stilt c Others U.Floors 2 6, d No of floors ( 8 ) 3 Set backs (m) 4 Site Area (m2) Road affected area (m2) 0 6 Net Area(m2) Tot-lot (m2) Height (m) No. of RWHPs 10 No. of Trees 11 Others D DETAILS OF FEES PAID (RS.) TOTAL : Front 7.61 Rear Side I Side II E OTHER DETAILS : 1 Contractor s all Risk Policy No /44/2016/665 Date 12/02/2016 Valid Upto 11/02/ Notarised Affidavit No Date 03/12/2015 Area (m2) 1, Enter Sr. No. in prohibitory Property Watch Register Date - 4 F G Floor handed over second floor Construction to be Commenced Before Construction to be Completed Before S.R.O. 26 April, April, 2019 TOTAL:.00

3 The Building permission is sanctioned subject to following conditions: 1. The permission accorded does not confer any ownership rights. The permission will be revoked at later stage, if it is found that the documents or information are false and fabricated. 2. If construction is not commenced within one year, building application shall be submitted afresh duly paying required fees. 3. Sanctioned Plan shall be followed strictly while making the construction & shall be displayed at the site. 4. Commencement Notice shall be submitted by the applicant before commencement of the building. 5. Completion Notice shall be submitted after completion of the building. 6. Occupancy Certificate is compulsory before occupying any building. 7. Public Amenities such as Water Supply, Electricity Connections will be provided only on production of occupancy certificate. 8. Prior Approval should be obtained separately for any modification in the construction. 9. Tree Plantation shall be done along the periphery and also in front of the premises. 10. Tot-lot shall be fenced and shall be maintained as greenery at owners cost before issue of occupancy certificate. 11. Rain Water Harvesting Structure (percolation pit) shall be constructed. 12. Space for Transformer shall be provided in the site keeping the safety of the residents in view. 13. Garbage House shall be made within the premises. 14. Cellar and stilts approved for parking in the plan should be used exclusively for parking of vehicles without partition walls & rolling shutters and the same should not be converted or misused for any other purpose. 15. This sanction is accorded on surrendering of Road affected portion of the site to Vijayawada Municipal Corporation at free of cost without claiming any compensation at any time as per the undertaking submitted. 16. Stocking of Building Materials on footpath and road margin causing obstruction to free movement of public & vehicles shall not be done, failing which permission is liable to be suspended. 17. This permission is given based on the inputs on pages, documents and drawing provided by Applicant. Applicant confirms that the documents/ drawings submitted electronically or inputs by them are correct. The final approvals of proceedings are subjected to verification of reports and documents by concerned official including site visit report. Any deviation identified will lead to modification/rejection of the proceedings. 18. The Developer/ Builder/ Owner to provide service road wherever required with specified standards at their own cost. 19. A safe distance from Electrical Lines shall be followed as per rules 20. If greenery is not maintained 10% additional property tax shall be imposed as penalty every year till the condition is fulfilled. 21. All Public and Semi Public buildings shall provide facilities to physically handicapped persons. 22. The mortgaged built up area shall be allowed for registration only after an Occupancy Certificate is produced. 23. The Registration authority shall register only the permitted built up area as per sanctioned plan. 24. The Financial Agencies and Institutions shall extend loans facilities only to the permitted built up area. 25. The Services like Sanitation, Plumbing, Fire Safety requirements, lifts, electrical installations etc., shall be executed under the supervision of Qualified Technical Personnel. 26. Architect / Structural Engineer if changed, the consent of the previous Architect / Structural Engineer is required and to be intimated to the Commissioner. 27. Construction shall be covered under the contractors all risk Insurance till the issue of occupancy certificate (wherever applicable). 28. As per the undertaking executed in terms of A.P. Building Rules-2012, a. The construction shall be done by the owner, only in accordance with sanctioned Plan under the strict supervision of the Architect, Structural Engineer and site engineer failing which the violations are liable for demolition besides legal action. b. The owner, builder, Architect, Structural Engineer and site engineer are jointly & severely responsible to carry out and complete the construction strictly in accordance with sanctioned plan. c. The Owner, Builder, Architect, Structural Engineer and Site Engineer are jointly and severely are held responsible for the structural stability during the building construction and should strictly adhere to all the conditions. d. The Owner Builder should not deliver the possession of any part of built up area of the building, by way of Sale / Lease unless and until Occupancy Certificate is obtained from Vijayawada Municipal Corporation after providing all the regular service connections to each portion of the building and duly submitting the following. (i) Building Completion Notice issued by the LTP duly certifying that the building is completed as per the sanctioned plan. (ii) Structural Stability Certificate issued by the Structural Engineer duly certifying that the building is structurally safe and the construction is in accordance with the specified designs. (iii) An extract of the site registers containing inspection reports of Site Engineer, Structural Engineer and Architect. (iv) Insurance Policy for the completed building for a minimum period of three years. 29. Structural Safety and Fire Safety Requirements shall be the responsibility of the Owner, Builder, Developer, Architect and St. Engineer to provide all necessary Fire Fighting installations as stipulated in National Building Code of India, 2005 like; (i) To provide one entry and one exit to the premises with a minimum width of 4.5 mts. and height clearance of 5 mts. (ii) Provide Fire resistant swing door for the collapsible lifts in all floors. (iii) Provide Generator, as alternate source of electric supply. (iv) Emergency Lighting in the Corridor / Common passages and stair case. (v) Two numbers water type fire extinguishers for every 600 Sq.mts. of floor area with minimum of four numbers fire extinguishers per floor and 5k DCP extinguishers minimum 2 Nos. each at Generator and Transformer area shall be provided as per I.S.I. specification No (vi) Manually operated and alarm system in the entire buildings; (vii) Separate Underground static water storage tank capacity of 25, 000 fits. Capacity. (viii) Separate Terrace Tank of 25,0001its capacity for Residential buildings. (ix) Hose Reel, Down Corner. (x) Automatic Sprinkler system is to be provided if the basement area exceed 200 Sq.mts. (xi) Electrical Wiring and installation shall be certified by the electrical engineers to ensure electrical fire safety. Transformers shall be protected with 4 hours rating fire resist constructions. (xii) To create a joint open spaces with the neighbors building / premises for maneuverability of fire vehicles. No parking or any constructions shall be made in setbacks area By order COMMISSIONER This is system generated report and does not require any signature. This is authorized document under rule 23 of AP building rules. For further confirmation anyone can access the department website with file number.

4 Annexure - III

5 SITE MAP SHOWING SURROUNDINGS OF PROJECT SITE Annexure - IV N Project site

6 TITLE : TREE STOREY C LIMITATION OF USE THIS DRAWING AND THE INFORMATION THERON IS THE PROPERTY OF "POOJA CRAFTED HOMES PVT LTD" AND SHOULD BE USED ONLY FOR THE PURPOSE FOR WHICH IT IS EXPRESSLY LOANED AND IS TO BE RETURNED UPON REQUEST OR COMPLETION OF THE WORK FOR WHICH IT WAS ISSUED. IT SHOULD NOT BE COPIED IN ANY MANNER NOR IS ANY INFORMATION TAKEN THEREFROM TO BE TRANSMITTED OR PASSED ON TO A THIRD PARTY. Security Boom barrier PLAN SHOWING THE PROPOSED COMMERCIAL & RESIDENTIAL BUILDING IN NTS.NO: 143/3 IN Block no: 7 REVENUE WARD NO:11 DOOR NO: , SITUATED AT PATAMATA, VIJAYAWADA TOWN, KRISH DISTRICT. ±000mm HOTEL ENTRY +150mm 7.03 TURAL GRADIENT mm BELONGING TO : 1) SRI. VALLURU MADHUSUDA RAO S/O LATE SRI.VALLURU KESHAVARAO 2) SRI. VALLURU ABHIV S/O SRI.VALLURU MADHUSUDA RAO 3) MISS. VALLURU SAHAJA D/O SRI.VALLURU MADHUSUDA RAO DEVELOPMENT AGREEMENT M/S. POOJA VENTURES PRAVATE LIMITED RESP: M.D SRI. D. SHOWRI REDDY S/O LATE SRI D. SOLOMON REDDY 8.10 ABUTTING ROAD +150mm (1) (2) ALL DIMENSIONS ARE IN METERS DO NOT SCALE OF THIS DRAWING OR AS SPECIFIED. (3) IF REQUIRED ANY FURTHER INFORMATION REQUESTING TO CONTACT PCH. (4) (5) (6) (7) ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE SPECIFIED. VERIFY THAT ALL DRAWINGS COMPILES WITH LOCAL BYELAWS AND NBC (National Building Code) REGULATION OF THE PROJECT CLEARLY. ALL DIMENSION TO BE CHECKED ON SITE BEFORE COMMENCEMENT OF ANY WORKS. VERIFY THAT ALL DRAWINGS FOLLOWS GFC ( Good For Construction ). ALL MOVABLE FURNITURE ARE NOT IN THE CONTRACT- OR'S SCOPE OF WORK. HOTEL EXIT ±000mm (8) (9) ALL ROAD MARKINGS, DIRECTION ARROWS & NUMBERING IN CAR PARKING AREAS SHALL BE DONE BY AS SPECIFIED. ANY CHANGE IN PROGRAMME OR OF ANY ALTERTIVES SHOULD IMMEDIATELY ADVISE TO PCH. (10) ALL THE EXTERL WALLS (IF APPLICABLE)SHALL BE INSULATED THERMALITE BLOCKS (AAC)/ THERMALITE CONCRETE BLOCKS UNLESS OTHERWISE SPECIFIED. THICKNESS AS INDICATED IN THE DRAWINGS (11) ALL GLAZED PANELS EXTERLLY SUCH AS DOORS, VISION PANELS, SPANDREL PANELS, SKYLIGHT & BALCONY HANDRAIL SHALL BE REFEREED TO THE PARTICULAR SPECIFICATION (12) ALL GLAZING PANELS INTERLLY FOR WINDOWS ON AIR WELLS SHALL BE 6MM OR SPECIFIED TOUGHENED THK. OBSCURED ANNEALED GLASS. DOORS, LOUVERED DOORS & WINDOWS SHALL FOLLOW THE DETAILS OF THE SPECIFIED SYSTEM ACCORDINGLY. (13) (14) (15) ALL PEDESTRIAN RAMPS AND STEPS SHALL BE PROVIDED WITH NON-SLIP CARBORANDOM MATERIAL AS FOLLOWS. STEPS SHALL HAVE 3 NOS. GROOVES FILLED WITH NON-SLIP CARBORANDOM MATERIALS. COLOR TO MATCH TREAD AND RISERS TILES. CONTRACTOR SHOULD SUBMIT ALL RELATED SHOP DRAWINGS REGARDING SPECIALIZED SUB-CONTRACTOR WORKS FOR ARCHITECTS/ENGINEERS APPROVAL. ALL EXTERL LANDSCAPE SERVICES (DRAINS, WATER & ELECTRICAL SUPPLY ETC.)SHALL BE REFFERED TO THE LANDSCAPE SPECIALIST TECHNICAL REQUIREMENTS. (16) ALL THE EXTERL AREAS IN THE GROUND FLOOR SHALL BE WATER PROOFED AS SPECIFIED PLUS SPECIAL WATER PROOFING MEMBER. ABUTTING ROAD TREE STOREY VIJAYAWADA Security RESIDENTIAL ENTRY/ EXIT +150mm -2400mm SITE PLAN ±000mm Boom barrier PROPOSED : MORTGAGE AREA : EXISTING : TO BE DISMANTLED : SCALE :- 1 : 150. SIGTURE OF THE OWNER'S SIGTURE OF THE ARCHITECT SIGTURE OF THE BUILDER STRUCTURAL ENGINEER