AHERA/NESHAP ASBESTOS INSPECTION REPORT

Size: px
Start display at page:

Download "AHERA/NESHAP ASBESTOS INSPECTION REPORT"

Transcription

1 AHERA/NESHAP ASBESTOS INSPECTION REPORT CLIENT: Julie M. Wilkie City of Greenwood Assistant City Manager 520 Monument St., PO Box 40 Greenwood, SC (864) LOCATION: 807 Neel St Greenwood, SC DATE OF INSPECTION: September 13, 2017 DATE OF REPORT: September 30, 2017 PREPARED BY: Michael D. Zavislak, NRCC-EAC, CHMM, CIH, PE (NC) & Robert Smith SUMMIT Engineering, Laboratory & Testing, P.C. (SUMMIT) 3575 Centre Circle Fort Mill, SC SUMMIT Job No

2 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Neel St, Greenwood, South Carolina September 30, 2017 AHERA/NESHAP ASBESTOS INSPECTION REPORT 807 Neel St Greenwood, SC TABLE OF CONTENTS SECTION PAGE TABLE OF CONTENTS... i LIST OF APPENDICES... i 1.0 REPORT CERTIFICATION EXECUTIVE SUMMARY SUSPECT MATERIALS Window Glazing Wallboard and Joint Compound Flooring Roofing CONCLUSIONS AND RECOMMENDATIONS... 4 FIGURES 1.0 Site Location Map LIST OF APPENDICES A Analytical Results B Asbestos Inspector s License C SUMMIT Documentation i

3 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Neel St, Greenwood, South Carolina September 30, REPORT CERTIFICATION SUMMIT is pleased to provide environmental consulting services for City of Greenwood. Please contact this office at with any questions or comments regarding the findings submitted in this report. This document, entitled AHERA/NESHAP Asbestos Inspection Report, was prepared for City of Greenwood and the South Carolina Department of Health and Environmental Control (SCDHEC) with sound practices and procedures and in accordance with Asbestos Hazard Emergency Response Act (AHERA), Title II of the Toxic Substance Control Act (TSCA), SCDHEC Regulation , 40 CFR 61, and 40 CFR 763 for Asbestos Containing Materials (ACM) guidance. The results obtained by the work documented in this report fulfill the requirements of federal, state, and local regulations regarding Asbestos Containing Materials Michael D. Zavislak, NRCC-EAC, CHMM, PE (NC) Date SC DHEC AHERA Asbestos Inspector No. BI Expiration Date: November 4, 2017 SC DHEC AHERA Asbestos Management Planner No. MP SC DHEC AHERA Asbestos Project Designer No. PD SC DHEC AHERA Asbestos Air Sampler No. AS SC DHEC AHERA Asbestos Supervisor No. SA C:\Users\rsmith\Desktop\Greenwood\807 Neel St\R - Asbestos Inspection.doc 1

4 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Neel St, Greenwood, South Carolina September 30, EXECUTIVE SUMMARY On September 13, 2017, SUMMIT Engineering, Laboratory & Testing, P.C. (SUMMIT) performed an AHERA/NESHAP Asbestos Inspection for City of Greenwood located at 807 Neel St, Greenwood, SC. The purpose of this inspection was to investigate available records for the specification of asbestos containing material (ACM), inspect for suspect materials, sample and analyze suspect materials to test for asbestos, and assess the condition and location of the ACM and other characteristics of the structure. A homogeneous material is a material that appears to be uniform when properties such as age, color, and texture are compared. Four (4) homogeneous areas were sampled. The homogeneous areas are described in detail in section 3.0 of this report. The wallboard and joint compound appears to be in damaged condition with a low potential for damage. The material is friable and is classified as a surfacing material. The material was sampled and the results indicated that the material is classified as Asbestos Containing Materials (ACM). The wallboard and joint compound contains 2% Chrysotile asbestos and there is approximately 5,000 square feet of this material. The sheet flooring appears to be in damaged condition with a low potential for damage. The material is non-friable and is classified as a miscellaneous material. The material was sampled and the results indicated that the material is classified as Asbestos Containing Materials (ACM). The sheet flooring contains 15% Chrysotile asbestos and there is approximately 250 square feet of this material. C:\Users\rsmith\Desktop\Greenwood\807 Neel St\R - Asbestos Inspection.doc 2

5 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Neel St, Greenwood, South Carolina September 30, SUSPECT MATERIALS 3.1 Window Glazing The window glazing appears to be in damaged condition with a low potential for damage. The material is friable and is classified as a miscellaneous material. The material was sampled and the results indicated that the material is classified as not Asbestos Containing Materials (ACM). The sample analysis of the material is enclosed in Appendix A. A detailed map showing the locations of the sampling locations can be found in the SUMMIT Documentation. 3.2 Wallboard and Joint Compound The wallboard and joint compound appears to be in damaged condition with a low potential for damage. The material is friable and is classified as a surfacing material. The material was sampled and the results indicated that the material is classified as Asbestos Containing Materials (ACM). The wallboard and joint compound contains 2% Chrysotile asbestos and there is approximately 5,000 square feet of this material. The sample analysis of the material is enclosed in Appendix A. A detailed map showing the locations of the sampling locations can be found in the SUMMIT Documentation. 3.3 Flooring The sheet flooring appears to be in damaged condition with a low potential for damage. The material is non-friable and is classified as a miscellaneous material. The material was sampled and the results indicated that the material is classified as Asbestos Containing Materials (ACM). The sheet flooring contains 15% Chrysotile asbestos and there is approximately 250 square feet of this material. The sample analysis of the material is enclosed in Appendix A. A detailed map showing the locations of the sampling locations can be found in the SUMMIT Documentation. 3.4 Roofing The roofing appears to be in damaged condition with a low potential for damage. The material is non-friable and is classified as a miscellaneous material. The material was sampled and the results indicated that the material is not classified as Asbestos Containing Materials (ACM). The sample analysis of the material is enclosed in Appendix A. A detailed map showing the locations of the sampling locations can be found in the SUMMIT Documentation. C:\Users\rsmith\Desktop\Greenwood\807 Neel St\R - Asbestos Inspection.doc 3

6 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Neel St, Greenwood, South Carolina September 30, CONCLUSIONS AND RECOMMENDATIONS On September 13, 2017, SUMMIT Engineering, Laboratory & Testing, P.C. (SUMMIT) performed a AHERA/NESHAP Asbestos Inspection for 807 Neel St, Greenwood, SC. SUSPECT MATERIAL ACM (Y/N) FRIABLE (Y/N) AMOUNT (Square feet) Window Glazing N Y 10 Windows Wallboard and Joint Y Y 5,000 Compound Sheet Flooring Y Y 250 Roofing N N 1,200 The wallboard and joint compound appears to be in damaged condition with a low potential for damage. The material is friable and is classified as a surfacing material. The material was sampled and the results indicated that the material is classified as Asbestos Containing Materials (ACM). The wallboard and joint compound contains 2% Chrysotile asbestos and there is approximately 5,000 square feet of this material. The sheet flooring appears to be in damaged condition with a low potential for damage. The material is non-friable and is classified as a miscellaneous material. The material was sampled and the results indicated that the material is classified as Asbestos Containing Materials (ACM). The sheet flooring contains 15% Chrysotile asbestos and there is approximately 250 square feet of this material. An Asbestos Project Design will be required prior to removal demolition of the structure. If the structure is to be renovated or demolished, a copy of this report and a notification of demolition or renovation forms must be submitted to The South Carolina Department of Health and Environmental Control (SCDHEC) at least ten working days prior to these activities taking place. Bidders are responsible for their own calculations and estimates of quantities. Actual quantities may be more or less than indicated. Though every effort was made to examine wall cavities and other areas for pipe insulation, spray-applied or trowel applied miscellaneous material or other miscellaneous materials and other Presumed Asbestos Containing Material (PACM), this survey and report only deals with accessible areas of the building. There may be additional inaccessible areas above ceiling, behind walls and below floors that become evident during demolition or renovation activities. If suspect materials are found, additional asbestos testing may be required. C:\Users\rsmith\Desktop\Greenwood\807 Neel St\R - Asbestos Inspection.doc 4

7 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Neel St, Greenwood, South Carolina September 30, 2017 FIGURES C:\Users\rsmith\Desktop\Greenwood\807 Neel St\R - Asbestos Inspection.doc

8 Figure 1 Site Location Map 807 Neel St Greenwood, SC SUMMIT ELT, PC Project: C:\Users\rsmith\Desktop\Greenwood\807 Neel St\R - Figure 1 Site Map.doc

9 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Neel St, Greenwood, South Carolina September 30, 2017 APPENDIX A ANALYTICAL RESULTS C:\Users\rsmith\Desktop\Greenwood\807 Neel St\Appendix A.rtf

10 Asbestos Laboratory Report Prepared for SUMMIT Engineering, Laboratory & Testing, P.C. Project: 807 Neel St Summit #: Date Analyzed: 9/22/2017 Date Reported: 9/22/2017 Total Samples Analyzed: 11 # Samples >1% Asbestos: 2 Method of Analysis: EPA 600 / R93 / 116 Page 1 of 4

11 Summit Laboratories 3575 Centre Circle, Fort Mill, SC Phone: (704) Summit Order: SUMMIT Engineering, Laboratory & Testing, P.C Centre Circle Drive Fort Mill, SC Date Received: 9/14/2017 Date Analyzed: 9/22/2017 Date Reported: 9/22/2017 Project : 807 Neel St Asbestos Sample ID Description Appearance % Fibrous % Non-Fibrous % Asbestos SF SF SF-3 Test Report: Asbestos Analysis of Bulk Material via EPA 600/R-93/116 Method using Polarized Light Microscopy DW-1-Drywall DW-1-Joint Compound A DW-2-Drywall DW-2-Joint Compound A DW-3-Drywall DW-3-Joint Compound A DW-4-Drywall DW-4-Joint Compound A DW-5-Drywall DW-5-Joint Compound A WG WG Sheet Flooring Sheet Flooring Sheet Flooring Drywall & Joint Compound Drywall & Joint Compound Drywall & Joint Compound Drywall & Joint Compound Drywall & Joint Compound Drywall & Joint Compound Drywall & Joint Compound Drywall & Joint Compound Drywall & Joint Compound Drywall & Joint Compound Window Glazing Window Glazing White,Blue,Brown Fibrous Homogeneous Gray,Brown Fibrous Homogeneous Tan Non-fibrous Homogeneous Gray,Brown Fibrous Homogeneous Gray,Brown Fibrous Homogeneous Gray,Brown Fibrous Homogeneous Gray,Brown Fibrous Homogeneous White,Gray Non-fibrous Homogeneous White,Gray Non-fibrous Homogeneous 5% Cellulose 80% Non-fibrous (other) 10% Cellulose 1% Glass 10% Cellulose 1% Glass 10% Cellulose 1% Glass 10% Cellulose 1% Glass 10% Cellulose 1% Glass Non-Asbestos 89% Non-fibrous (other) 98% Non-fibrous (other) 89% Non-fibrous (other) 89% Non-fibrous (other) 89% Non-fibrous (other) 89% Non-fibrous (other) 100% Non-fibrous (other) 100% Non-fibrous (other) 15% Chrysotile Positive Stop (not analyzed) Positive Stop (not analyzed) None Detected 2% Chrysotile None Detected Positive Stop (not analyzed) None Detected Positive Stop (not analyzed) None Detected Positive Stop (not analyzed) None Detected Positive Stop (not analyzed) None Detected None Detected Analyst(s): Chris Estes Page 2 of 4

12 Summit Laboratories 3575 Centre Circle, Fort Mill, SC Phone: (704) Summit Order: SUMMIT Engineering, Laboratory & Testing, P.C Centre Circle Drive Fort Mill, SC Date Received: 9/14/2017 Date Analyzed: 9/22/2017 Date Reported: 9/22/2017 Project : 807 Neel St Test Report: Asbestos Analysis of Bulk Material via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample ID Description Appearance % Fibrous % Non-Fibrous % Asbestos Roof Roof Asphalt Shingle Asphalt Shingle Black,Gray Fibrous Homogeneous Black,Gray Fibrous Homogeneous 5% Glass 95% Non-fibrous (other) 5% Glass 95% Non-fibrous (other) None Detected None Detected Analyst(s): Chris Estes Page 3 of 4

13 METHOD: EPA 600 / R93 / 116 For samples easily separated into homogeneous layers, each component will be analyzed separately. The sample may not be representative of the larger material in question. Interpretation and use of test results are the responsibility of the client. Due to the limitations of the EPA 600 Method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles, mastic and roofing can be difficult to analyze by PLM. Reanalysis by Transmission Electron Microscopy (TEM) to verify results of <1% or None Detect for these materials is recommended. This sheet may not be reproduced except with permission from Summit Laboratories. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Analyst(s): Chris Estes Approved By: Michael Zavislak, Approved Signatory NVLAP Lab Code Summit Laboratories, 3575 Centre Circle, Fort Mill, SC 29715, Phone: (704) Page 4 of 4 This is the last page of the report

14

15

16 September 22, 2017 SUMMIT Engineering, Laboratory & Testing, Inc Centre Circle Fort Mill, SC CLIENT PROJECT: 807 Neel St; CEI LAB CODE: T Dear Customer: Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on September 18, The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield Method. Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield method is <1% depending on the processed weight and constituents of the sample. Thank you for your business and we look forward to continuing good relations. If you have any questions, please feel free to call our office at Kind Regards, Tianbao Bai, Ph.D., CIH Laboratory Director 730 SE Maynard Road Cary, NC

17 ASBESTOS ANALYTICAL REPORT By: Transmission Electron Microscopy Prepared for SUMMIT Engineering, Laboratory & Testing, Inc. CLIENT PROJECT: 807 Neel St; CEI LAB CODE: T TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 REPORT DATE: 09/22/17 TEL:

18 ASBESTOS BULK ANALYSIS By: TRANSMISSION ELECTRON MICROSCOPY Client: SUMMIT Engineering, Laboratory & Testing, Inc Centre Circle Fort Mill, SC Project: 807 Neel St; TEM BULK CHATFIELD / EPA 600 / R93 / 116 Client ID Lab ID Material Description Sample Weight (g) Organic Material % Acid Soluble Material % Acid Insoluble Material % Asbestos % WG-3 Window Glazing None T68170 Detected Roof-3 Asphalt Shingle None T68171 Detected Page 1 of 2

19 LEGEND: None METHOD: CHATFIELD & EPA/600/R-93/116 LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%) REGULATORY LIMIT: >1% by weight This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by CEI Labs, Inc. CEI Labs makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request. Samples were received in acceptable condition unless otherwise noted. ANALYST: Jennifer Turner APPROVED BY: Tianbao Bai, Ph.D., CIH Laboratory Director Page 2 of 2

20

21

22 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Neel St, Greenwood, South Carolina September 30, 2017 APPENDIX B INSPECTOR S LICENSES C:\Users\rsmith\Desktop\Greenwood\807 Neel St\Appendix B.rtf

23 SGDHEltrTSSUED Asbestos ld Card Michael Zavislak CONSULTPD PD.OOO92 AIRSAMPLER AS.O0296 SUPERAHERA SA-OI5'I5 GONSULTIIP MP.OO.I04 consultbt Bl E\piration Date,l,llo4l,l7 11t03t17 1,uou,t7,l,llo2l,l7 1,,1o2r,7

24 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Neel St, Greenwood, South Carolina September 30, 2017 APPENDIX C SUMMIT DOCUMENTATION C:\Users\rsmith\Desktop\Greenwood\807 Neel St\Appendix C.rtf

25 AHERA/NESHAP Asbestos Inspection SUMMIT Project No Neel Street, Greenwood, South Carolina September 30, 2017 SITE PHOTOGRAPHS Front of structure. C:\Users\rsmith\Desktop\Greenwood\807 Neel St\R-Ph I - Site Photographs.doc 1