1 sectton SIGNAGE PART 1 GENERAL 1.01 SECTION INCLUDES A. Building identification signs and apartment unit identification signs SUBMITTALS A. See Section Administrative Requirements, for submittal procedures. B. Product Data: Manufacturer's printed product literature for each type of sign, indicating sign styles, font, foreground and background colors, locations, overall dimensions of each sign. C. Signage Schedule: Provide information sufficient to completely define each sign for fabrication, including building number, apartment number, and letter sizes, fonts, and colors. D. Manufacturer's Installation Instructions: Include installation templates and attachment devices. PART2 PRODUCTS 2.O1 MANUFACTURERS A. Individual Metal Letter Signs: 1. Gemini. 2. Substitutions: See Section Product Requirements SIGNAGEAPPLICATIONS A. Accessibility Compliance: All signs are required to comply with ADAAG and ANSI/ICC A and applicable building codes, unless otherwise indicated; in the event of conflicting requirements, comply with the most comprehensive and specific requirements. B. Apartment Door Letters: Provide a letter for every apartment entry doorway adjacent to door. Locate as directed by Owner. 1. Use individual f lat cut metal letters. 2. Character Height: 3 inch (75 mm). C. Building ldentification Signs: 1. Use individual Flat cut metal letters and numbers. 2. Character Height: 9 inch. Sign to read "Building #". 3. Mount on outside wall in location shown on drawings SIGN TYPES A. Color, Font and Mounting: Unless otherwise indicated: 1. Character Font: Helvetica, Arial, or other sans serif font. 2. Character Case: Upper case only. 3. Character Color: Painted finishas selected from Manufacturer's standard colors. 4. Mounting: Stud Mounted. PART 3 EXECUTION 3.01 EXAMINATION A. Verify that substrate surfaces are ready to receive work INSTALLATION A. lnstall in accordance with manufacturer's instructions. B. Install neatly, with horizontal edges level. C. Locate signs where indicated: 1. lf no location is indicated obtain Owner's instructions. D. Protect from damage until Substantial Completion; repair or replace damage items. END OF SECTION PWA SIGNAGE

2 THIS PAGE INTENTIONALLY LEFT BLANK.

3 sectton TOILET, BATH, AND LAUNDRY ACCESSORIES PART 1 GENERAL 1.01 SECTION INCLUDES A. Accessories for toilet rooms, showers. and tubs SUBMITTALS A. See Section Administrative Requirements, for submittal procedures. B. Product Data: Provide data on accessories describing size, finish, details of function, attachment methods. C. Manufacturer's Installation Instructions: Indicate special procedures and conditions requiring special attention. PART2 PRODUCTS 2.O1 MANUFACTURERS A. Products listed are made by Bobrick; B. OtherAcceptableManufacturers: 1. A & J Washroom Accessories Inc: 2. American Specialties, lnc: 3. Bradley Corporation: 4. Substitutions: Section Product Requirements. C. All items of each type to be made by the same manufacturer MATERIALS A. Accessories - General: Shop assembled, free of dents and scratches and packaged complete with anchors and fittings, steel anchor plates, adapters, and anchor components for installation. 1. Grind welded joints smooth. B. Stainless Steel Sheet: ASTM A 666, Type 304. C. Stainless SteelTubing: ASTM A 269, Type 304 or 316. D. Mirror Glass: Float glass, ASTM C 1036 Type l, Class 1, Quality Q2, with silvering, protective and physical characteristics complying with ASTM C E. Adhesive: Two component epoxy type, waterproof. F. Fasteners, Screws, and Bolts: Hot dip galvanized, tamper-proof, security type F N SHES A. Stainless Steel: No. 4 satin brushed finish, unless otherwise noted TOILET ROOM ACCESSORIES A. Toilet Paper Dispenser: Single roll,recessed,stainless steel unit. 1. Product: manufactured by Bobrick. B. Mirrors: 1/4" plate glass mirror. See drawings for size SHOWER AND TUB ACCESSORIES A. Towel Bar: Stainless steeltype 304, 3/4 inch (20 mm) square tubular bar; rectangular brackets, concealed attachment, satin finish. 1. Length: 1B inches (460 mm) and24". 2. Product: B-674x18 and B-674x24 manuf actured by Bobrick. 3. Quantity: 2-1B" bars-one each side of lavatory, 4-24" bars, stacked installation-2 on wall opposite lavatory mirror and 2 in WC/Tub Room. PWA ACCESSORIES TOILET, BATH, AND LAUNDRY

4 PART 3 EXECUTION 3.01 EXAMINATION A. Verify existing conditions before starting work. B. Verify exact location of accessories for installation. C. Verify that field measurements are as indicated on drawings. D. See Section for installation of blocking, reinforcing plates, and concealed anchors in walls and ceilings PREPARATION A. Deliver inserts and rough-in frames to site for timely installation. B. Provide templates and rough-in measurements as required INSTALLATION A. Install accessories in accordance with manufacturers' instructions. B. Install plumb and level, securely and rigidly anchored to substrate. C. Mounting Heights and Locations: As required by accessibility regulations, as indicated on drawings, and as follows: END OF SECTION PWA ACCESSORIES TOILET, BATH, AND LAUNDRY

5 sectton FIRE PROTECTION SPECIALTIES PART 1 GENERAL 1.01 SECTION INCLUDES A. Fire extinguishers SUBMITTALS A. See Section Administrative Requirements, for submittal procedures. B. Product Data: Provide extinguisher operational features. C. Manufacturer's Certificate: Certify that products meet or exceed specif ied requirements. D. Maintenance Data: Include test, refill or recharge schedules and re-certification requirements. PART2 PRODUCTS 2.O1 MANUFACTURERS A. Fire Extinguisher Cabinets and Accessories: 1. JL Industries, Inc; Product Cosmic 5E: wwr,v.jlindustries.com. 2. Substitutions: See Section Product Requirements FIRE EXTINGUISHERS A. Fire Extinguishers - General: Comply with product requirements of NFPA 10 and applicable codes, whichever is more stringent. B. Dry Chemical Type Fire Extinguishers: Carbon steel tank, with pressure gage. 1. Class: 3A:408C. 2. Size: 5 pound (2.27 kg). 3. Finish: Baked polyester powder coat, Red color. PART 3 EXECUTION 3.01 INSTALLATION A. Provide to Owner-1 per unit for installation by Owner atcompletion of Construction prior to occupancy. END OF SECTION PWA O44OO. 1 FIRE PROTECTION SPECIALTIES

6 THIS PAGE INTENTIONALLY LEFT BLANK.

7 sectlon MAIL BOXES PARTl GENERAL 1.01 SECTION INCLUDES A. Grouped mail boxes located outdoors SUBMITTALS A. See Section Administrative Requirements, for submittal procedures. B. Product Data: Provide manufacturer's standard catalog data for specified products. C. Shop Drawings: Prepared specifically for this project; show dimensions of mail boxes, wall cuts, and inteface with other products QUALITY ASSURANCE A. Comply with United States Postal Service Regulations DELIVERY, STORAGE, AND HANDLING A. Inspect the materials upon delivery to assure that specified products have been received. B. Store materials protected from exposure to harmful weather conditions. C. Handle materials to prevent damage or marring of finish. PART2 PRODUCTS 2.O1 MANUFACTURERS A. Acceptable Manufacturer: Auth-Florence Manufacturing Company; 591 Mitchell Road, Glendale Heights, ll 60139; ASD. Tel: (630) , Tel: (800) , Fa><: (630) B. Substitutions: See Section Product Requirements. C. Provide all mail boxes f rom a single manufacturer MA L BOXES A. Outdoor Mail Boxes: USPS-approved cluster box units, pedestal mounted, front loading, aluminum cabinet. 1. Model: Series Number of Compartments: 16,3-1/4 inches high, with 2parcel compartments, and 1 outgoing mail compartment. 3. Compartment Depth: 17 inches (430 mm). 4. Cabinet: 0.10 inch (2.5 mm) thick welded aluminum sheet. 5. Doors: Minimum inch (3 mm) thick aluminum, with stainless steel hardware and hinges. 6. Locks: 5-pin cylinder cam lock with spring-loaded cover on each unit, 3 keys each lock. 7. Pedestal Stand: Clear anodized aluminum, 32 inches (813 mm) high. 8. Finish: Manufacturer's standard powder coat finish. PART 3 EXECUTION 3.01 INSTALLATION A. Install mail boxes in accordance with shop drawings and manufacturer's printed installation instructions, B. Align, plumb, and level; anchor in accordance with requirements ADJUSTING A. Adjust doors and locks to operate correctly. END OF SECTION PWA MAIL BOXES

8 THIS PAGE INTENTIONALLY LEFT BLANK.

9 sectton WIRE STORAGE SHELVING PART 1 GENERAL 1.01 SECTION INCLUDES A. Wall mounted wire closet shelving. B. Accessories DELIVERY, STORAGE, AND HANDLING A. Store products in manufacturer's unopened packaging until ready for installation. B. Store products under cover and elevated above grade. C. Store flat to prevent warpage and bending. PART2 PRODUCTS 2.01 MANUFACTURERS A. Wire Storage Shelving: 1. ClosetMaid Corporation: 2. RubberMaid Closet and Organization Products: 3. Substitutions: See Section Product Requirements SHELVING APPLICATIONS A. Shelf Depth: 16 inches, unless othenruise indicated. B. Bedroom Closets: 1. Wall-to-wall shelf with free sliding hanger rod. C. Coat Closets: 1. Wall-to-wall shelf with integral hanger rod. D. Linen Closets: 1. Wall-to-wall shelves spaced at 13 inch (330 mm) vertically, not less than 16 inch (408 mm) deep MATERIALS A. Wire Shelving: Factory-assembled coated wire mesh shelf assemblies for wall-mounting, with all components and connections required to produce a rigid structure that is free of buckling and warping. 1. Construction: Cold-drawn steel wire with average tensile strength of 100,000 psi (690 MPa) resistance welded into uniform mesh units, square, rigid, flat, and free of dents or other distortions, with wires trimmed smooth. 2. Coating: PVC or epoxy, applied after fabrication, covering all surfaces. 3. PVC Coating: 9 to 11 mils (0.23 to mm) thick. 4. Epoxy Coating: Non-toxic epoxy-polyester powder coating baked-on finish, 3 to 5 mils (0.76 to 1.27 mm) thick. 5. Standard Mesh Shelves: Cross deck wires spaced at 1 inch (25.4 mm). 6. Shelf and Rod Units: Integral hanging rod at front edge of shelf. 7. Free-Sliding Hanging Rod: Integral hanging rod that permits uninterrupted sliding of hangers the full width of the shelf. B. Mounting Hardware: Provide manufacturer's standard mounting hardware; include support braces, wall brackets, back clips, end clips, poles, and other accessories as required for complete and secure installation; factory finished to match shelving. C. Fasteners: As recommended by manufacturer for mounting substrates. PWA WIRE STORAGE SHELVING

10 PART 3 EXECUTION 3.01 INSTALLATION A. Install in accordance with manufacturer's instructions. with shelf surfaces level. B. Cap exposed ends of cut wires. C. Install back clips, end clips at side walls, and support braces at open ends. Install intermediate support braces as recommended by manufacturer. END OF SECTION PWA WIRE STORAGE SHELVING

11 PART 1 GENERAL sectron EXTERIOR WINDOW SHUTTERS 1.01 SECTION INCLUDES A. Modular, shop fabricated, decorative window shutters to be mounted on structure SUBMITTALS A. See Section Administrative Requirements, for submittal procedures. B. Shop Drawings: Prior to commencement of fabrication, submit shop drawings, showing all fastening details, and manufacturer's technical and descriptive data. Include field dimensions of openings and elevations on shop drawings WARRANTY A. See Section Closeout Submittals, for additionalwarranty requirements. B. Shutters: Correct defective work within a one year period after date of Substantial Completion. C. Finish Warranty: Provide manufacturer's lifetime transferrable warranty on factory finish against cracking, peeling, and blistering. PART 2 PRODUCTS 2.01 MANUFACTURERS A. Shutters: 1. Mid-America Siding Components; 2. Substitutions: See Section Product Requirements SHUTTERS A. Raised Panel Shutters: Shop fabricated, shop finished, raised panel vinyl shutters. 1. Conf iguration: As indicated on drawings. 2. Product: Custom Style-A-Panel. 3. Sizes: As indicated on drawings. 4. Finish Color: As selected by Architect from manufacturer's standard range. PART 3 EXECUTION 3.01 EXAMINATION A. Examine substrates for conditions that might prevent satisfactory installation. B. Do not install until after all adjacent painting, roofing and masonry have been completed. C. Do not proceed with installation until all conditions are satisfactory INSTALLATION A. lnstall in accordance with manufacturer's installation instructions. B. Set units level, plumb, with uniform joints, and aligned with building elements. C. Anchor units to structure as recommended by manufacturer using fasteners that are compatible with installation in brick veneer. D. Touch-up damaged finish coating using material provided by manufacturer to match original coating TOLERANCES A. Maximum Variation from Level: Plus/Minus 1/8 inch (3.175 mm) CLEANING A. Clean exterior surfaces units of dust and debris; follow manufacturer's cleaning instructions for the finish used. PWA EXTERIOR WINDOW SHUTTERS

12 3.05 PROTECTION A. Protect units after installation to prevent damage due to other work until the Date of Substantial Com pletion. END OF SECTION PWA EXTERIOR WINDOW SHUTTERS