1 SECTION _ SUMMARY University Cntact: Structural Services, Maintenance & Operatins (302) PART 1 GENERAL 1.1 SUMMARY A. The drawings and General Prvisins f the cntract, including the Cnditins f the Cntract (General, Supplementary, and ther Cnditins, if any) and Divisins 1 as apprpriate, apply t the Wrk specified in this sectin. 1.2 WORK INCLUDED A. Hardware fr Exterir and Interir Drs ther than specified in specific dr sectins. B. Threshlds and Weather stripping fr Exterir Drs. C. Specialties as listed herein. 1.3 RELATED WORK A. Sectin 08100: Hllw Metal Drs and Frames. B. Sectin 08210: Wd Drs. C. Sectin 08400: Aluminum Entrances. 1.4 SUBSTITUTIONS A. Apprval f alternative and/r substitute prducts will be cnsidered nly under terms and cnditins specified in Sectin This paragraph applies when specific manufacturer s names fllw a specified manufacturers name in Part 2.02, r when n manufacturer s names fllw a specified manufacturers name in Part B. Alternate and/r substitute prducts will be cnsidered nly when request includes dcumented prf prduct cmplies with IBC std (2003) r UL10C. C. Requests fr substitutin are t be in writing and received by the Architect at least ten days prir t the bid date. The acceptance f any substitutins will be by addendum. Unauthrized substitutins will nt be accepted. D. The quality f all items f hardware has been clearly indicated by the manufacturer s name and prduct number. Certain prducts are specified withut substitutin and are t be furnished exactly as specified. 1.5 REFERENCE STANDARDS A. DHI Recmmended lcatins fr Builders Hardware fr Standard Steel Drs and Frames B. DHI Scheduling Sequence and Scheduling Frmat Divisin 8: Openings SECTION Page 1

2 C. DHI Prcessing Hardware Schedules and Templates D. IBC 2003 Editin, Hinges E. IBC Sectin F. NFPA 80 Fire Drs & Windws 1999 G. NFPA 101 Life Safety Cde 2000 H. ANSI A Material and Finishes I. ANSI A Electrmagnetic Lcks J. ANSI A Delayed Egress lcks K. ANSI A117.1 Accessible and Usable Buildings and Facilities, 1998 L. Gverning Cdes: When cnflict ccurs between cdes and standards the mst stringent requirement gverns. 1.6 SUBMITTALS A. Submit in accrdance with Sectin B. Dr hardware Schedule & Frmat 1. Submit 6 cpies f schedule n 8.5 x 1 sheets numbered cnsecutively and n a 3.5 cmputer disk in a pdf file. The schedule shall be reviewed prir t submissin by a certified Architectural Hardware Cnsultant, wh shall affix his r her seal attesting t the cmpleteness and crrectness f the schedule. 2. Furnish cver sheet listing name f prject as shwn n Cntract Dcuments, Owner, Architect, Cntractr, Architectural hardware Cnsultant (AHC) wh prepared the hardware submittal and date f submittal. 3. Furnish a vertical listing f hardware items used fllwed by manufacturer s name either n cver sheet r immediately fllwing cver sheet. Hrizntal schedule is nt acceptable. 4. Schedule hardware items fr each dr separately in typed vertical frm. List each dr in numerical rder under a separate heading using dr number in sequence as shwn in dr Opening Schedule. The Finishing Hardware Schedule is t clearly indicate the swing, lcatin, number, size, and thickness f each dr, as well as type number and finish f each article f hardware required fr each pening. The Finishing Hardware Schedule is t fllw the guidelines and frmat as set frth in the DHI publicatin, Scheduling Sequence and Scheduling Frmat. Include with each submittal: a. Dcumentatin frm UL r apprved testing agency indicating hardware is apprved fr use n drs cmplying with IBC 2003, r UL10C. Divisin 8: Openings SECTION Page 2

3 b. Wiring diagrams: Elevatin, riser, pint t pint. c. Written descriptin f peratin at all headings with electric hardware. d. Schedules submitted withut the abve materials will be cnsidered incmplete and will nt be reviewed. e. Apprval f schedule des nt relieve Cntractr f prviding hardware specified fr prject. f. Tw cmplete sets f catalg cuts are t accmpany the Finishing Hardware Schedule. The list f cuts is t include the item, manufacturer, and item number. g. Name, address, and phne number f autmatic dr peratr installer. h. Letter frm autmatic dr peratr manufacturer certifying the abve listed installer is a factry authrized installer. 1.7 QUALITY ASSURANCE A. Rated Openings: Hardware used in labeled fire r smke rated penings t be listed fr thse types f penings and bear the identifying label r mark indicated. U.L. apprved fr fire. Exit devices in nn labeled penings t be listed fr panic. Prject requires dr assemblies and cmpnents that are cmpliant with psitive pressure and S label requirements. Specificatins must be crss referenced and crdinated t ensure that ttal pening engineering is cmpatible with UL 10C Standard fr Psitive Pressure Fire Tests f Dr Assemblies, and IBC Certificatin(s) f cmpliance shall be made available upn request by the Authrity Having Jurisdictin. B. Qualificatins: 1. Cntractr is respnsible fr: a. Prper applicatin and fit f dr and specialty hardware in lcatins as indicated n drawings r as specified. b. Items nt specifically mentined, but necessary t cmplete wrk are t be furnished matching in quality and finish f specified items in similar lcatins. c. Crdinate dimensins between hardware items. d. Furnish and install nly hardware items listed n apprved Dr hardware submittal. Divisin 8: Openings SECTION Page 3

4 2. Cntractr s selectin f hardware supplier: C. Electric Hardware: a. Prper applicatin and fit f dr and specialty hardware in area f prject fr perid n less than five years. b. Recgnized supplier t have, full time, n staff an Architectural Hardware Cnsultant (AHC) certified by the Dr and hardware Institute r persn f equal experience wh is acceptable t the Architect and GC. This cnsultant is t be registered in the Dr and Hardware Institute Seal Prgram. c. Hardware supplier s AHC t be available at all reasnable times during curse f wrk t meet persnally with Owner, Architect r Cntractr fr hardware cnsultatin. d. Supplier willing t agree in writing t maintain parts inventry f items supplied fr future service t Owner. e. Supplier t furnish all the hardware listed in this Sectin Finishing hardware. All material is t be furnished ttally, including the hardware fr Aluminum Drs, as listed in the sets. N items may be excluded. Any hardware listed as installed, is t be furnished and installed as part f the Finishing Hardware Bid. The installatin is t be by an authrized installer as listed in the sets r by Addendum. The successful bidder is t prvide a letter frm the factry certifying that the installer is a factry authrized installer. 1. Unless nted therwise in Divisin 16, prvide electric hardware items rated 24 VDC. 2. Crdinate electrical hardware requirements with Divisin 16 wrk fr electrical distributin, fire alarm, and security systems. D. Submittal Review Cnference: 1. Hardware supplier t arrange a meeting with Cntractr, Architect, and wner fr the review f hardware, hllw metal, and wd dr shp drawings. 2. The hardware supplier attendee is t be an AHC. 3. Representatives frm the hllw metal and wd dr manufacturers are als t attend. Representatives are t be factry emplyees, r factry sales agents. Whlesale warehuse emplyees are nt acceptable. 4. Meeting lcatin is t be determined by the Architect. E. Pre Installatin: 1. Hardware supplier t meet with installer and discuss installatin f hardware, templates and any unique hardware applicatins. Divisin 8: Openings SECTION Page 4

5 1.8 OERATION AND MAINTENANCE DATA A. Furnish manufacturer's parts list and maintenance instructins fr each type f hardware prvided and furnish the Owner with the necessary wrenches and tls required fr prper maintenance f installed hardware. 1.9 GENERAL REQUIREMENTS A. The hardware specified herein is intended t cver all necessary materials required t cmplete fully the hardware requirements f the building, except fr thse items f hardware that are cvered specifically under ther sectins f the specificatins. If hardware fr any particular lcatin is nt specified herein, furnish item f identical design, finish and functin required fr a similar lcatin, hardware shall be f suitable type and ample size and weight t perfrm the service required DELIVERY, STORAGE AND HANDLING A. Delivery: 1. Delivery f all hardware t the building site shall be its riginal package and prperly wrapped. Package each f hardware with crrect screws, installatin templates and blts fr fastening, free frm flaws and defects. 2. Deliver packages clearly identified with heading number and dr number as apprved n hardware schedule. B. Strage and handling: 1. General Cntractr and/r Cnstructin Manager t prvide strage area fr hardware, which is dry, secure, and cmplete with shelving and tables fr unpacking and string. A lcked rm is t be prvided by the General Cntractr and/r Cnstructin Manager f the finishing hardware. 2. All hardware t be delivered t the jbsite by emplyees f the finishing hardware supplier. N drp shipments are permitted. 3. Upn delivery, the General Cntractr and/r Cnstructin Manager and the hardware supplier t check in the hardware against the apprved Finishing hardware Schedule, and place the items n the shelves. 4. After delivery the General Cntractr and/r Cnstructin Manager is respnsible fr the hardware against theft, misplacement, defacements, etc. Divisin 8: Openings SECTION Page 5

6 1.11 REPRESENTATIVE A. Prvide a cmpetent representative t inspect and direct methd f setting, applying, and adjustment f all hardware. Representative shall nt be required t remain cnstantly at the site, but shall be readily available t cnsult with the Owner, Cntractr and Architect at the prject site. Representative shall peridically visit the site during installatin f the hardware, and shall make final inspectin, t assure that all items are crrectly installed and adjusted TEMPLATES A. All hardware fr pre machined wd, and hllw metal drs and frames shall be made t template. B. Furnish templates and apprved hardware schedules t all interested manufacturers in sufficient quantities fr preparatin f their wrk t receptive hardware. Templates will be required fr all hardware applied t hllw metal and steel. C. Where necessary fr prper installatin, furnish actual hardware t the manufacturer fr his installatin. Furnish samples t the manufacturer as required s that all prvisins fr attachment, clearance and ther requirements can be made WIRING DIAGRAMS A. Furnish wiring fr scheduled items requiring pwer. B. Prvide an elevatin drawing fr each dr shwing lcatin f electric hardware. Include pint t pint wiring and riser diagrams and pwer requirements. C. Submit wiring diagrams and dr elevatins with hardware submittal. PART 2 PROCEDURES 2.1 GENERAL A. Prvide items as listed in the schedule at the end f this sectin, cmplete t functin as intended. B. Items as same functin and perfrmance are acceptable in cnfrmance with Sectin and as listed herein. C. Finish: 1. Materials shall have finishes as listed in the schedule f hardware and as fllws: Exterir butt hinges where scheduled US26D (Dull Chrme Plated). Ball bearing nly. Interir butt hinges US26D (Dull Chrme Plated). Ball bearing nly. Divisin 8: Openings SECTION Page 6

7 Exterir and Interir lcksets US32D (Satin Stainless Steel). Cylinders US26D (Dull Chrme Plated). Panic Exit Devices US32D (Satin Stainless Steel). Push, Pull, and Kick Plates US32D (Satin Stainless Steel). Overhead Stps, Flush Blts, and Flr Stps US26D (Dull Chrme Plated). Mullins USP (Prime Cat fr Painting). Dr Clsers Sprayed Aluminum t match adjacent hardware. D. Fastenings: Furnish apprpriate screw attachments, thrugh blts, cncealed fasteners and machine screws. 1. Furnish threshlds with machine screw and expansin shields at bth ends and at six inches n centers. E. Hardware specified in these dcuments is intended t cver necessary material required t fully cmplete hardware requirements fr specified penings. It is the intentin and it shall be understd that hardware herein specified shall be figured in sufficient quantities t fill requirements f the cntract drawings even thugh every item necessary t d s is nt specified herein, except fr thse items f hardware that are specifically cvered under ther sectins f the specificatins. F. If hardware fr any particular lcatin is nt specified herein, it shall be furnished f similar design and quality equal t ther items specified fr similar lcatins. It shall be f suitable type and ample size and weight t perfrm services required. Where Underwriter's Label is nted n dr schedule, hardware fr the pening is t meet the labeling requirements. G. Where finish shape r size f member taking hardware is such t prevent use f, r make unsuitable exact types specified, suitable types shall be furnished having as near as practical same peratin as that which is specified. H. Hardware shall be delivered t building site prperly wrapped with crrect screws and blts fr fastening, and shall be free frm flaws and defects. It shall be prperly labeled fr lcatin with item number crrespnding with hardware schedule. Threshlds and flr type dr stps shall have "tamping shields". I. Munting requirements: Refer t Sectin fr requirements. J. It is the intent that hardware be furnished and installed s that it meets applicable Barrier Free Facilities Standards f the State f Delaware, IBC, A.N.S.I. A117.1, and ADA where applicable. Nte especially the fllwing: 1. Lever heights. 2. Knurled levers as required by Handicapped cde and where directed. 3. Clser clsing frce. Divisin 8: Openings SECTION Page 7

8 4. Pulls and Push Plate height. 2.2 ACCEPTABLE MANUFACTURERS A. Manufacturer and type: Butt hinges scheduled as manufactured by Hager Hinge Cmpany, and shall f Ball Bearing and Plain Bearing, five knuckle types as scheduled. 1. Hinges shall be f sizes as fllws: Drs 3 feet and less in width 4½ inch in height. Drs 3 feet and ver in width 5 inch in height. Drs 5 feet and less in height Prvide 1 Pair. Drs 7 feet and less in height Prvide 1½ Pairs. Drs 7 feet and ver in height Prvide ½ Pair f each 2 feet in height. Width f hinges shall be determined by jamb cnditins and shall be f sufficient width t clear trim. Hinges shall be f duty scheduled; sizes scheduled may vary depending n cnditins. Prvide N.R.P. (nn remvable pins) n all drs that are listed L.H.R. r R.H.R. that are equipped with butt hinges. 2. Dr Clsers: Shall be as manufactured by Nrtn and shall be f surface types1604 f regular and parallel type arms. Clsers shall be f sizes as recmmended by the manufacturer, and shall be equipped with a back check valve, and tw separate valves fr latch and clsing speeds. All clsers shall have a five year warranty. In residence halls LCN clsers are preferred, mdel 4040 unless apprved. Clsers shuld be thru blted. Special Ntes: Interir Husing LCN 1261 Exterir Husing LCN 4040 XP Interir Academics Nrtn 1604 Exterir Academics LCN 4040 XP 3. Handicap Operatrs: Shall be as manufactured by Nabc Entrances, Inc. Operatrs shall be Mdel GT 710 r Hrtn 7000 lw energy, f arm sizes as scheduled with buttns lcated 36" abve finish flr. Operatrs n all nnrated drs shuld be tied t EMERGENCY pwer. 4. Exit Devices: Shall be as manufactured by Sargent, and shall be Series 8800, f functins as scheduled. 5. Lcksets and Latchsets: Shall be as manufactured by Best Access Systems and shall be 45H Lever Series mrtise type, with Lever 15/Rse H trim, r Schlage L series, with lever 06 and A Rse trim. Lcksets shall be functins scheduled. Strikes shall be f sufficient length t clear trim. Divisin 8: Openings SECTION Page 8

9 6. Cylinders shall be as manufactured by Best Access Cmpany, and shall be extruded brass, and shall be f remvable cre type, equipped with n less than 7 pins. 7. Flush Blts, Wall Bumpers, and Flr Stp: Shall be as manufactured by Ives and shall be as scheduled. 8. Push Plates, Pull Plates, and Kick Plates: Shall be as manufactured by Ives and shall be f types, and sizes scheduled. Plates shall be.050 ga. and shall have edges beveled n all sides. 9. Overhead Stps: Shall be as manufactured by Glynn Jhnsn Crp., and shall be f the 80 r 100 series, f sizes as scheduled. 10. Balance f hardware items shall be scheduled. B. Acceptable Substitutins: 1. Butt Hinges: McKinney and Bmmer. Ball bearing nly. 2. Flush Blts, Stps, and Wall Bumpers: Triangle Brass Mfg. C., and Builders Brass Wrks. 3. Push, Pull and Kick Plates: Triangle Brass Mfg. C., Dr Cntrls Internatinal, Rckwd and Builders Brass Wrks. 4. Dr Clsers: Nrtn 1600 Series. 5. N substitutes will be permitted n the fllwing: a. Best Access Systems/ Schlage L series mrtise lcksets and latchsets. b. Glynn Jhnsn Hlders c. Best Lck Cylinders d. Nabc Entrances, Inc., Aut Operatrs 6. Equivalent prducts f ther manufacturers may be prpsed fr apprval during bidding. C. Templates: All hardware fr metal drs and frames shall be made t template. Furnish templates and hardware scheduled in sufficient quantities fr preparatin f all hardware. D. Gasketed Drs: Where nted n the schedule, prvide gasketing fr drs cnsisting f Natinal Guard Prducts. Clear andized aluminum finish. Divisin 8: Openings SECTION Page 9

10 2.3 KEYING A. Keying shall be factry engineered, prduced and recrded. B. All lcks shall be furnished with cylinders, f type (1E74) r (1E72) with mdificatins as required, manufactured by Best Access Systems. Cres shall be keyed t the Best Masterkey System f the University, standard in academics and premium in husing, as apprved by the University and crdinated by the University Lck and Hardware Services. C. Fr the cnstructin perid, lcks shall be prvided with black plastic plugs, fr cntractr's cnvenience. These shall be replaced, at time f substantial cmpletin f the building, by the University, with permanent cres keyed by the University. Exterir drs shall be keyed alike by the University t a Prject cre fr the cnvenience f the cntractr and the University at the time f hardware installatin t secure the cnstructin site. 2.4 HARDWARE SCHEDULE A. Each dr shall have hardware cnfrming t the freging specificatins gruped in sets accrding t the fllwing schedule. Manufacturers' numbers used in the schedule are nt cmplete and must be supplemented t indicate the hereinbefre specified features. B. Lcks: All lcks t be mrtise type with heavy gauge nickel plate steel case and heavy gauge steel beveled frnts. Armred scalp plate and strikes t be brnze. Latch blts t be twpiece mechanical anti frictin blt. All lcks t have an auxiliary dead lcking latch blt t prevent retractin f regular latch blt when dr is lcked. Lck finish t be US32D. All lcks t receive wrught bxes with strike. C. Surface Clsers: Surface type shall have a full rack and pinin mechanism prviding psitive cntinuus checking actin frm fully pen psitin. Key cntrlled adjusting valves t cntrl clsing speed, latching speed and back check. Surface type t be surface munted with case finished in aluminum. All clsers t be furnished with sex nuts and blts. Surface type t have 15% spring pwer adjustment. All clsers shall be munted in parallel arm cnfiguratin. D. Dr Operatrs: Dr peratrs and cntrls are t be hardwired. On all nn rated penings. E. Exit Device Rim Flat Bar: Exit devices t cnsist f rim devices with flat crss bar and straight thrugh peratin. Latch blts t have 3/4" thrw. Outside trim t be cast with thru blts. US32D finish. F. Dr Hlders and Stps: Overhead hlders and stps as specified t be architectural brnze. Surface hlders t be supplied with thru blts fr dr. Wall bumpers t be cast brnze r brass Divisin 8: Openings SECTION Page 10

11 (finished US26D) and furnished with prper attachments fr fastening the wall bumpers. G. Pulls and Plates: Pulls are t be f style and finish as indicated with thru blts. Push plates are t be stainless steel.050" thickness with sizes as indicated. H. Kick Plates and Mp Plates: Kick plates and mp plates t be.050 ga. with beveled edges (B4E). Width f kick plates t be 2" less than dr width n single dr and 1" less n pair f drs. I. Silencers: Interir frames withut gasketing will receive rubber silencers #20 r #21, tw (2) fr each duble and three (3) fr each single frame. PART 3 EXECUTION 3.1 EXAMINATION A. General Cntractr and/r Cnstructin Manager t verify drs and frames are ready t receive wrk, and dimensins are as indicated n shp drawings r as instructed by manufacturers. B. General Cntractr and/r Cnstructin Manager t verify pwer supply is available t electrically perated devices. 3.2 INSTALLATION A. Install finish hardware in accrdance with reviewed hardware schedule and manufacturer s printed instructins. Pre fit hardware befre finish is applied, remve and reinstall after finish is cmpleted. Install hardware s that parts perate smthly, clse tightly and d nt rattle. B. Installatin f hardware shall cmply with JFPA 80, UL10C, and NFPA 101 requirements. C. Set units level, plumb and true t line and lcatin. Adjust and reinfrce attachment t substrate as necessary fr prper installatin and peratin. D. Drill and cuntersink units which are nt factry prepared fr anchrage fasteners. Space fasteners and anchrs in accrdance with industry standards. E. Set threshlds fr exterir drs in full bed f butyl rubber r plyisbutylene mastic sealant, frming tight seal between threshld and surface t which set. Securely and permanently anchr threshlds, using cuntersunk nn ferrus screws t match clr f threshlds (stainless steel screws at aluminum threshlds). F. Lead Prtectin: Lead wrap hardware penetrating lead lined drs. Levers and rses t be lead lined. Apply kick and armr plates with 3M adhesive #1357, as recmmended by 3M C., n lead lined drs. Divisin 8: Openings SECTION Page 11

12 3.3 FIELD QUALITY CONTROL A. After installatin has been cmpleted, prvide services f qualified hardware cnsultant t check Prject t determine prper applicatin f finish hardware accrding t schedule. Als check peratin and adjustment f hardware items. B. Adjust dr cntrl devices t cmpensate fr final peratin f hearting and ventilating equipment. 3.4 ADJUSTING AND CLEANING A. At final cmpletin, hardware shall be left clean and free frm disfigurement. Make final adjustment t dr clsers and ther items f hardware. Where hardware is fund defective repair r replace r therwise crrect as directed. B. Adjust dr clsers t meet pening frce requirements f Unifrm Federal Accessibility Standards. C. Final Adjustment: Wherever hardware installatin is made mre than ne mnth prir t acceptance r ccupancy f space r area, return t wrk during week prir t acceptance r ccupancy, and make final check and adjustment f hardware items in such space r area. Clean perating items as necessary t restre prper functin and finish f hardware and drs. D. Instruct Owner s persnnel in prper adjustment and maintenance f dr hardware and hardware finishes. E. Clean adjacent surfaces siled by hardware installatin 3.5 PROTECTION A. Prvide fr prper prtectin f items f hardware until Owner accepts Prject as cmplete. 3.6 EXISTING OPENINGS A. Existing Openings: 1. The finishing hardware supplier is respnsible fr surveying all existing drs and frames in rder t verify the existing hardware preps and assure cmpatibility with specified hardware. 2. The survey is t be accmplished prir t submitting schedules and shp drawings. 3. Hardware supplier is t furnish a letter, certifying that the survey was cmpleted prir t preparing the shp drawings and schedules. A cpy f the survey list with dr numbers and survey infrmatin is t be included with this letter. Divisin 8: Openings SECTION Page 12

13 4. Hardware schedules nt cmplying with abve will nt be reviewed and will be returned fr prper cmpliance. 3.7 HARDWARE SETS A. The fllwing schedule f hardware sets shall be cnsidered a guide nly, and the supplier is cautined t refer t general cnditins, and the preamble t this sectin. It shall be the hardware supplier s respnsibility t furnish all required hardware. B. Prvide hardware as specified in the previus articles and the fllwing sets: Set #1 Drs: 1 pr. main entrance drs with surface verhead stp LHR/RHR Act. Each t have: 6 Hinges Hager BB ½ X 4 ½ NRP US32D 2 Exit Devices Sargent STS US32D 1 Mullin Sargent L 980S USP 1 Rim Cylinder Best 1ESPL 7 A05994 US26D 1 Mrtise Cylinder Best 1ESPL 7 A35124 X R709 US26D 2 Clsers LCN PA4040 XP AL 2 Kickplate Ives 8"x35"x.050 ga.b4e US32D 2 O.H. Stps Glynn Jhnsn 81S US26D 1 Threshlds Natinal Guard 425 x 72" AL 2 Silencers Ives 20(HM) r 21(WD) GR Set #2 Dr: 1 single main entrance dr with surface OH stp LHR/RHR Each t have: 3 Hinges Hager BB ½ X 4 ½ NRP US32D 1 Exit Device Sargent STS US32D 1 Rim Cylinder Best 1ESPL 7 A05994 US26D 1 Clser LCN PA 4040 XP AL 1 O.H. Stp Glynn Jhnsn 81S US26D 1 Threshld Natinal Guard 425 x 36" AL 3 Silencers Ives 20(HM) r 21(WD) GR Divisin 8: Openings SECTION Page 13

14 Set #3 Drs: 1 pr. vestibule drs nn lcking LHR/RHR Each t have: 6 Hinges Hager BB1168 US26D 2 Pull Plates Ives S32D 3½ x 15" US32D 2 Push Plates Ives 8200S32D 3½ x 15" US32D 2 Clsers LCN PA 4040 XP AL 2 Kickplate Ives 8"x35"x.050 ga.b4e US32D 2 O.H. Stp Glynn Jhnsn 81S US26D 4 Silencers Ives 20(HM) r 21(WD) GR Set #4 Drs: Office dr with wall stp may be a labeled pening LHR/RHR Each t have: 3 Hinges Hager BB1279 4½ x 4½ NRP US26D 1 Lck Set Best 45 H7 E 15 H US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 Wall Stp Ives 407½ US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #5 Drs: Classrm dr with mrtise verhead stp may be used n a labeled pening LHR/RHR Each t Have: 3 Hinges Hager BB1168 4½ x 4½ NRP US26D 1 Lck Set Best 45H7 R 15 H US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 Kickplate Ives 8"x 34"x.050 ga.b4e US32D 1 O.H. Stp Glynn Jhnsn 100S ADJ US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #6 Drs: Classrm dr with wall stp LH/RH Each t have: 3 Hinges Hager BB1168 4½ x 4½ US26D 1 Lck Set Best 45H7 R 15 H US32D 1 Stp Ives 407½ US26D Divisin 8: Openings SECTION Page 14

15 3 Silencers Ives 20(HM) r 21(WD) GR Set #7 Drs: Classrm dr with mrtise verhead stp LH/RH Each t have: 3 Hinges Hager BB1168 4½ x 4½ US26D 1 Lck Set Best 45H7 R 15 H US32D 1 O.H. Stp Glynn Jhnsn 100S ADJ US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #8 Drs: Classrm dr with wall stp LHR/RHR Each t have: 3 Hinges Hager BB1168 4½ x 4½ NRP US26D 1 Lck Set Best 45H7 R 15 H US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 Stp Ives 407½ US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #9 Drs: Strerm dr with surface stp may be used n labeled pening LHR/RHR Each t have: 3 Hinges Hager BB1279 4½ x 4½ NRP US26D 1 Lck Set Best 45H7 D 15 H US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 O.H.Stp Glynn Jhnsn 450S US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #10 Dr: Strerm dr with mrtise verhead stp may be used n labeled pening LHR/RHR Each t have: 3 Hinges Hager BB1279 4½ x 4½ NRP US26D 1 Lck Set Best 45H7 D 15 H US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 O.H. Stp Glynn Jhnsn 410S US26D 3 Silencers Ives 20(HM) r 21(WD) GR Divisin 8: Openings SECTION Page 15

16 Set #11 Drs: Strerm dr with wall stp may be used n a labeled pening LHR/RHR Each t have: 3 Hinges Hager BB1279 4½ x 4½ NRP US26D 1 Lck Set Best 45H7 D 15 H US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 Stp Ives 407½ US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #12 Drs: Strerm dr with wall stp LH/RH Each t have: 3 Hinges Hager BB1279 4½ x 4½ US26D 1 Lck Set Best 45H7 D 15 H US32D 1 Stp Ives 407½ US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set # 13 Drs: 1 pr. drs t strerm with surface verhead stp may be used n a labeled pening LHR/RHR Each t have: 6 Hinges Hager BB1279 4½ x 4½ NRP US26D 2 Flush Blts Ives 458 US26D 1 Lck Set Best 45H7 D 15 H US32D 1 Mrt.Cylinder Best 1E74 US26D 1 Clser Nrtn PA 1604 BC SNB AL 2 Kickplates Ives 8"x35"x.050 ga.b4e US32D 1 O.H. Stp Glynn Jhnsn 450S US26D 2 Silencers Ives 20(HM) r 21(WD) GR Divisin 8: Openings SECTION Page 16

17 Set #14 Drs: 1 pr. drs t strerm with wall stp may be used n a labeled pening LHR/RHR Each t have: 6 Hinges Hager BB1279 4½ x 4½ NRP US26D 2 Flush blts Ives 458 US26D 1 Lck Sets Best 45H7 D 15 H US32D 1 Clser Nrtn PA 1604 BC SNB AL 2 Kickplates Ives 8"x35"x.050 ga.b4e US32D 2 Stps Ives 407½ US26D 2 Silencers Ives 20(HM) r 21(WD) GR Set #15 Dr: Strerm dr with wall stp may be used n labeled pening LHR/RHR Each t have: 3 Hinges Hager BB1279 4½ x 4½ NRP US26D 1 Lck Set Best 45H7 D 15 H US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 Stp Ives 407½ US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #16 Drs: Interir dr t mechanical rm with wall stp, special lever fr handicap may be used n a labeled pening LHR/RHR Each t have: 3 Hinges Hager BB1279 4½ x 4½ NRP US26D 1 Lck Set Best 45H7 D 15 H TL US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 Stp Ives 407½ US26D 3 Silencers Ives 20(HM) r 21(WD) GR Divisin 8: Openings SECTION Page 17

18 Set #17 Dr: Mechanical rm dr with surface stp, special lever fr handicap may be used n a labeled pening LHR/RHR Each t have: 3 Hinges Hager BB1279 4½ x 4½ NRP US26D 1 Lck Set Best 45 H7 D 15 H TL US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 O.H. Stp Glynn Jhnsn 450S US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #18 Dr: Clset r passage dr with mrtise verhead stp (N Lck) LH/RH Each t have: 3 Hinges Hager BB1279 4½ x 4½ US26D 1 Latch Set Best 45H0 N 15 H US32D 1 O.H. Stp Glynn Jhnsn 410S US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #19 Dr: Passage set (N Lck) may be used n a labeled pening LHR/RHR Each t have: 3 Hinges Hager BB1279 4½ x 4½ US26D 1 Latch Set Best 45H0 N 15 H US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 Stp Ives 407½ US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #20 Dr: Bedrm r bathrm dr with wall stp LH/RH Each t have: 3 Hinges Hager BB1279 4½ x 4½ US26D 1 Privacy Set Best 45H0 L 15 H US32D 1 Stp Ives 407½ US26D Divisin 8: Openings SECTION Page 18

19 3 Silencers Ives 20(HM) r 21(WD) GR Set #21 Drs: Public bathrm dr with wall stp LHR/RHR Each t have: 3 Hinges Hager BB1168 4½ x 4½ NRP US26D 1 Deadlck Best 38H7 R US26D 1 Pull Plate Ives S32D 3½ x 15" US32D 1 Push Plate Ives 8200S32D 3½ x 15" US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 Stp Ives 407½ US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #22 Drs: Interir crridr with wall stp, dr cntrls t be hardwired n all nn rated drs LHR/RHR, LH/RH. Each t have: 3 Hinges Hager BB1168 4½ x 4½ NRP US26D 1 H.C. Operatr Nabc GT710 US26D 2 Wall switch Nabc (Wall) US32D Nabc (Frame) US32D 1 Pull Plate Ives S32D 3½ x 15" US32D 1 Push Plate Ives 8200S32D 3½ x 15" US32D 1 Kick plate Ives 8"x34"x.050 ga.b4e US32D 1 Stp Ives 407½ US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #23 Drs: Interir stair twer fire dr with wall stp will be used n a labeled pening LHR/RHR Each t have: 3 Hinges Hager BB1168 4½ x 4½ NPR US26D 1 Exit Device Sargent ETL US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 Kick plate Ives 8"x34"x.050 ga.b4e US32D 1 Stp Ives 407½ US26D Divisin 8: Openings SECTION Page 19

20 3 Silencers Ives 20(HM) r 21(WD) GR Set #24 Drs: Crridr/Bedrm with wall stp LH/RH Each t have: 3 Hinges Hager BB1279 4½ x 4½ US26D 1 Lck set Best 45H7 T 15 H US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 Stp Ives 407½ US26D 3 Silencers Ives 20(HM) r 21(WD) GR Set #25 Drs: Fire Cmmand Center dr with wall stp, lck t be 24VAC and cnnected t fire alarm system may be used n labeled pening. Each t have: 2 Hinges Hager BB1279 4½ x 4½ US26D 1 Hinge Hager BB1279 4½ x 4½ US26D 1 Lck Set Best 45H7 EWEU 15 H US32D 1 Clser Nrtn PA 1604 BC SNB AL 1 Stp Ives 407½ US26D 3 Silencers Ives 20 (HM) r 21 (WD) GR Set #26 Drs : Sliding dr (N lck) Each t have: 1 set B1 Passing hdw. F ' 2 Flush pulls Ives 227 US26D Set #27 Drs: A garage dr with n utside peratin Each t have: Hardware by dr manufacturer Divisin 8: Openings SECTION Page 20

21 Set #28 ALL ELECTRICAL PANELS WITH LOCK IN PUBLIC AREAS Each t have: 1 Lck Best 5L7RL Series US26D (Handing as required) Set #29 ALL CABINET DOORS REQUIRING LOCK ALL CABINET DRAWERS REQUIRING LOCK Each t have: 1 Lck Best 3L7RD Series US26D (Handing as required) Set #30 ALL ELEVATOR CONTROLS REQUIRING LOCK Each t have: 1 Cylinder Best Apprpriate Cylinder US26D Set #31 Drs t be held pen by electrmagnets labeled r nn labeled pening LHR/RHR, LH/RH. Each t have: 1 Electrmagnet Rixn 997 x 24 VDC US26D END OF SECTION Divisin 8: Openings SECTION Page 21