1 RAILROAD COMMISSION OF TEXAS 1701 N. Congress P.O. Box Austin, Texas Status: Form W-2 OIL WELL POTENTIAL TEST, COMPLETION OR RECOMPLETION REPORT, AND LOG Date: Tracking.: Approved 01/31/ OPERATOR INFORMATION Operator Name: FDL OPERATING, LLC Operator.: Operator Address: ATTN ROBIN SWANNER PO BOX 472 JUDSON, TX API.: Well.: 1D Lease Name: UNIVERSITY 9-30 WELL INFORMATION County: REAGAN RRC District.: 7C Field Name: RRC Lease.: Field.: Location: Section: 30, Block: 9, Survey: UNIVERSITY LANDS, Abstract: SPRABERRY (TREND AREA) Latitude: This well is located 7.5 miles in a NW direction from BIG LAKE, which is the nearest town in the county. Longitude: Purpose of filing: Type of completion: Type of Permit Permit to Drill, Plug Back, or Deepen Rule 37 Exception Fluid Injection Permit O&G Waste Disposal Permit Other: Spud date: 10/20/2010 FILING INFORMATION Reclass Producing to Injection Date 05/24/2011 Permit COMPLETION INFORMATION Date of first production after rig released: Date plug back, deepening, recompletion, or Date plug back, deepening, recompletion, or drilling operation commenced: 11/13/2017 drilling operation ended: 11/17/2017 Number of producing wells on this lease in this field (reservoir) including this well: Total number of acres in lease: Total depth TVD (ft.): Plug back depth TVD (ft.): Was directional survey made other than inclination (Form W-12)? Yes Recompletion or reclass? Other/Recompletion Well Type: Active UIC Completion or Recompletion Date: 11/25/ Yes Type(s) of electric or other log(s) run: Electric Log Other Description: Neutron logs Distance to nearest well in lease & reservoir (ft.): 0.0 Elevation (ft.): Total depth MD (ft.): Plug back depth MD (ft.): Rotation time within surface casing (hours): Is Cementing Affidavit (Form W-15) attached? Multiple completion? 2731 GL F Location of well, relative to nearest lease boundaries Off Lease : of lease on which this well is located: Feet from the South Line and Feet from the East Line of the UNIVERSITY 9-30 Lease. 11/25/2017 Yes PACKET FORMER FIELD (WITH RESERVOIR) & GAS ID OR OIL LEASE NO. Field & Reservoir Gas ID or Oil Lease. Well. Prior Service Type SPRABERRY (TREND AREA) Producing Page 1 of 4

2 W2: N/A GAU Groundwater Protection Determination SWR 13 Exception Date of test: Number of hours tested: Was swab used during this test? Oil (BBLS): Gas - Oil Ratio: Water (BBLS): Oil (BBLS): Oil Gravity - API - 60.: Water (BBLS): 0 FOR NEW DRILL OR RE-ENTRY, SURFACE CASING DEPTH DETERMINED BY: Depth (ft.): Depth (ft.): Date: 07/26/2010 INITIAL POTENTIAL TEST DATA FOR NEW COMPLETION OR RECOMPLETION Production method: 24 Choke size: Oil produced prior to test: PRODUCTION DURING TEST PERIOD: Gas (MCF): Flowing Tubing Pressure: CALCULATED 24-HOUR RATE Gas (MCF): Casing Pressure: CASING RECORD Casing Hole Setting Multi - Multi - Cement Slurry Top of TOC Type of Size Size Depth Stage Tool Stage Shoe Cement Amount Volume Cement Determined Row Casing (in.) (in.) (ft.) Depth (ft.) Depth (ft.) Class (sacks) (cu. ft.) (ft.) By 1 Surface 11 3/4 14 3/4 752 C Circulated to Surface 2 Intermediate 8 5/ C & POZ Calculation 3 Conventional Production 5 1/2 7 7/ C & POZ Calculation 4 Conventional Production 5 1/2 7 7/ H & POZ Calculation LINER RECORD Row Liner Size (in.) Hole Size (in.) Liner Top (ft.) Liner Bottom (ft.) Cement Class Cement Amount (sacks) Slurry Volume (cu. ft.) Top of Cement (ft.) TOC Determined By N/A TUBING RECORD Row Size (in.) Depth Size (ft.) Packer Depth (ft.)/type 1 2 7/ / PRODUCING/INJECTION/DISPOSAL INTERVAL Row Open hole? From (ft.) To (ft.) 1 L Page 2 of 4

3 ACID, FRACTURE, CEMENT SQUEEZE, CAST IRON BRIDGE PLUG, RETAINER, ETC. Was hydraulic fracturing treatment performed? Is well equipped with a downhole actuation sleeve? Production casing test pressure (PSIG) prior to hydraulic fracturing treatment: Has the hydraulic fracturing fluid disclosure been reported to FracFocus disclosure registry (SWR29)? If yes, actuation pressure (PSIG): Actual maximum pressure (PSIG) during hydraulic fracturing: Row Type of Operation Amount and Kind of Material Used Depth Interval (ft.) 1 Cast Iron Bridge Plug CIBP WITH 3 SACKS CEMENT Cast Iron Bridge Plug CIBP WITH 3 SACKS (20') CEMENT Other 4 SHOTS PER FOOT/NO OTHER STIMULATION FORMATION RECORD Is formation Formations Encountered Depth TVD (ft.) Depth MD (ft.) isolated? SPRABERRY Yes Yes WOLFCAMP Yes Yes STRAWN Yes Yes Remarks Do the producing interval of this well produce H2S with a concentration in excess of 100 ppm (SWR 36)? Is the completion being downhole commingled (SWR 10)? REMARKS Page 3 of 4

4 PUBLIC COMMENTS: [RRC Staff :22:14.205] H-5 received 11/20/2017 RRC REMARKS CASING RECORD : TUBING RECORD: PRODUCING/INJECTION/DISPOSAL INTERVAL : ACID, FRACTURE, CEMENT SQUEEZE, CAST IRON BRIDGE PLUG, RETAINER, ETC. : POTENTIAL TEST DATA: Printed Name: Telephone.: OPERATOR'S CERTIFICATION Robin Swanner Title: Consulting Agent (903) Date Certified: 01/31/2018 Page 4 of 4

5 RAILROAD COMMISSION OF TEXAS,Form W N. Congress Rev. 08/2014 P.O. BoK Austin, TeKas Cementer: Fiil l.1 shaded areas. Operator: Fill in other items. District.: 7C Well.: 1 swo Lease Name: University 9-30 Field Name: Spraberry (Trend Area) Cementer P-5.: WEU IN>'ORMATIO~I., County: Reagan API.: le as e.: Field.: I D,1111 & P<,mlt., ~ I. CASING CEMENTING DATA : Type of casing: D Conductor D Surface D Intermediate D Liner D Production Drilled hole size (In.): Depth of drilled hole (ft.): Est. % wash-out or hole enlars :iment: Size of casing In O.D. (in.): Casing weight (lbs/ft) and grade:. of centralizers used: Was cement circulated to ground surface (or bottom of cellar) outside Setting depth shoe (ft.): Top of liner (ft.): casing? D VES D NO If no for surface casing, ekplaln In Remarks. Setting depth liner (ft, : Hrs. waiting on cement before drill-out: Calculated top of cement (ft.): Cementing date: SLURRY Sl_u_r., N_o_.._o_f_S_ac_k_s C_l_a_ ss -t- A_d_dl_tl_v_es V_o_lu_m_e-'-(c_u_. ft_..,.). Hei ht (ft.) Depth of drilled hole (ft.): Est. % wash-out or hole enlarg i_m_e_n_t_: Size of casing In O.D. (in.): Casing weight (lbs/ft) and grade:. of centralizers used: Tapered string drilled hole size (in.) Tapered string depth of drilled hole (ft.) U er: Lower: U per: Lower: ' Tapered string size of casing In 0.0. (In.) Tapered string casing weight{lbs/ft} and grade Tapered string no. of centrallz;!rs used Upper: Lower: Upper: Lower: U er: Low, _.r._ Was cement circulated to ground surface (or bottom of cellar) outside casing? DYES [] NO Setting depth shoe (ft.): Hrs. waiting on cement before drill-out: Calculated top of cement (ft.): Cementing date: SLURRY Slur.. of Sacks Class Additives Volume cu. ft.) Hei ht (ft.) 1 2 Type of casing: osurface Production 0Tapered production Multi-stage cement/ov tool OMultlt le parallel strings I Drilled hole size (In.): Depth of drilled hole (ft.): Est. % wash-out or hole enlar~~ment: Size of casing In 0.0. (In.): Casing weight (lbs/ft) and grade:. of centralizers used: ~ Tapered string drilled hole site (In.) Tapered string depth of drilled hole (ft.) Upper: Lower: U er: Lower: Tapered string size of casing in 0.0. (in.) Tapered string casing weight(lbs/ft) and 1rade Tapered string no. of centrallt?rs used U er: Lower: Upper: Lower: U er: Low ~_r_: Was cement circulated to ground surface (or bottom of cellar) outside casing? 0VES ONO Setting depth tool (ft.): ==--..;=' ;;'--.; - ;c...;,. -I Hrs. waiting on cement before drill-out: Calculated top of cement (ft.): Cementing date: SLURRY Slur.. of Sacks Class Additlvn Volume (cu. ft.) Hel ht (ft Total

6 P_LU_G_#1_+-_P_LU_G--#_2_+-_P_LU_G_#_3 -+--P_L_U_G_#4_+---P--LU"-G---#S'--+---P--LU;;..G;;..# '?_. -+--P_LU_G_#7_ -l Cementing Date I - Sl_z_e_o_f h- o-'1"'e_o_r _p-ip_e_(-in-.) t ,i--1' l t------; f Depth to bottom of tubing or drill pipe (ft.) Cement retainer setting depth (ft.) CIBP settln depth (ft. 4050' Amount of cement on top ofcibp (ft.) 20' Sacks of cement used 3 Slur, volume pumped (cu. ft.) 1--Ca_lc:_u_la_te_d_t_o.,_p_o_f p,_l"""ug"""-(ft..)' ' Measured top of plug, If tagged (ft.) Slurry weight (lbs/gal) 14,8 Class/t e of cement Class C! ' CEMENTER'S CERTIFICATE: I declare under penalties prescribed In Sec , Texas Natural Resources Code, that I am authi>rized to make this certification, that the cementing of casing and/or the placing of cement plugs In this well as shown in the report was performed.by me or under my supervision, and that the cementing data and facts presented on both sides of this form are true, correct, and complete, to the best of, my knowledge. This certification covers cementing data only. ~ ' Joe Stewart, Supervisor Renegade Services ~ ~~ Name and title of cementer's representative Cementing Company /Signature P.O. Box 707 Snyder, TX v(mber 16, 2017 Address City, State, Zip Code Tel: Area Code Number Date: mo. day yr. OPERATOR'S CERTIFICATE : I declare under penalties prescribed in Sec. 91,143, Texas Natural Resources Code, that I am authc:rited to make 1his certification, that I have knowledge of the well data and Information presented in this report, and that dat facts pre o 'i both sides of this form are true, correct, and complete, to the best of my knowledge. This certification covers all well data. Robin Swanner Typed or printed name of operator's representative P.O. Box 472 Judson, TX Consultant TIiie Address City, State, Zip Code Tei: Area Code 'Number yr. Instructions for Form W-15, Cementing Report NOTICE: The Form W-1S must be submitted as an attachment to a Form G l {Gas Well Back Pressure Test, Completion or Recompletion Report, and l :1g), Form W- 2 (Oil Well Potential Test, Completion or Recompletlon Report, and Log), Form W-3 (P lugging Record), or Form W 4 (Appllcatfon for Multiple Completion), any tiw e cement Is pumped in a wellbore. A. B. C. o. E. F. What to file: An operator should file an original and one copy of the completed Form W 1S for each cementing company used on a well. rte cementing of different casing strings on a well by one cementing company may be reported on one form. The Form W ls should be filed with the Form W-3, Plugging Record, unless the Form W-3 is signed by the cementing company representath '!. When reporting dry holes, operators must complete Form W-15, in addition to Form W-3, to show any casing cemented in the hole. ' How to file: An oil and gas completion report and form W-15 may be filed online using the Commissl on's Online System (https;//webapps.rrc.texas.gov/securlty/login.do) or a paper copy of the form may be malled to the Commission in Austln (P.O. Box Austin, Texas ). Surface casing: An operator must set and cement sufficient surface casing to protect ail usable-quality'water strata, as defined by, tl)e Grc>Jndwat\lr Advisory Unit In Austin. Sufficient cement shall be used to fill the annular space outside the casing from the shoe,to the ground surf.ice or to the.bottf,m of the cellar. Before drilling a well, an operator must obtain a letter from the Groundwater Advisory Unlt stating the protection depth. Surface casing should notrbe set deeper than 200 feet below the specified depth without prtor approval from the Commission. To plug and abandon a well, operators must use only cementers approved by the Commission's Director of Field Operations In accordance. with SWR 14. ( Cementing companies, service companies, or operators can qualify as approved cementers by demonsti'ating 'that they are able to mix and pump cer ~ent In compliance with Commission rules and regulations. Estimated% wash-out: If the estimated % wash-out is less than 20% (or 30% along the Gulf Coast), provide supporting documentation such as a caliper tog to show how the estimated % wash-out was obtained. \, Multi-stage cement: An operator must report the multi-stage cement shoe in II. Casing Cementing Data section by selecting the type o casing and Multi-stage. cement shoe. The operator must report the multi-stage cement tool in Ill. Caslng Cementing Data section py.selecting the type of casing ;ind Multi-stage cement/cv tool. Multiple parallel strings: An operator should file the Form W 1S as an attachment to the Form W-4, Appllcat.lon for Multiple Completlco., ' A11 operator may be. required to submit multiple Form W-15s to show all data for multiple parallel strings. G. Slurry data: If cement job exceeds three slurries, contlnue the list of slurries In the Slurry table in the subsequent Casing' Cementing Cata box.

7

8 GROUNDWATER PROTECTION DETERMINATION Form GW-2 Groundwater Advisory Unit Date Issued: 31 August 2017 GAU Number: Attention: Operator.: FDL OPERATING, LLC ATTN ROBIN SWANNER JUDSON, TX API Number: County: REAGAN Lease Name: University 9-30 Lease Number: Well Number: 1D Total Vertical Depth: Latitude: Longitude: Datum: NAD27 Purpose: Location: Injection into n-producing Zone (W-14) Survey-UL; Block-9; Section-30 To protect usable-quality groundwater at this location, the Groundwater Advisory Unit of the Railroad Commission of Texas recommends: The interval from the land surface to a depth of 675 feet must be protected. te: Unless stated otherwise, this recommendation is intended to apply only to the subject well and not for area-wide use. This recommendation is for normal drilling, production, and plugging operations only. It does not apply to saltwater disposal operation into a nonproductive zone (RRC Form W-14). This determination is based on information provided when the application was submitted on 08/30/2017. If the location information has changed, you must contact the Groundwater Advisory Unit, and submit a new application if necessary. If you have questions, please contact us at or gau@rrc.texas.gov. Groundwater Advisory Unit, Oil and Gas Division Form GW-2 Rev. 02/2014 P.O. Box Austin, Texas Internet address: