LEAD-BASED PAINT ABATEMENT SPECIFICATIONS

Size: px
Start display at page:

Download "LEAD-BASED PAINT ABATEMENT SPECIFICATIONS"

Transcription

1 BARR & CLARK Independent Environmental Testing Asbestos Lead Mold Phase I LEAD-BASED PAINT ABATEMENT SPECIFICATIONS OF 5 BUILDINGS 1400 E. MISSION BOULEVARD POMONA, CA PROJECT NO JUNE 23, 2017 Prepared For: City of Pomona 505 S. Garey Avenue Pomona, CA Prepared By: Reviewed By: Matt Crochet State of California Certified Lead Inspector / Risk Assessor Project Monitor Jeremy Nguyen State of California Certified Lead Inspector / Risk Assessor B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

2 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page 2 TABLE OF CONTENTS 1.0 GENERAL SUMMARY OF THE SCOPE OF WORK STANDARDS AND GUIDELINES OWNER S REPRESENTATIVE SUBMITTALS AND NOTICES QUALIFICATIONS CONTRACTOR WORKERS MATERIALS WORKER HEALTH AND SAFETY MEDICAL SURVEILLANCE PERSONAL PROTECTIVE EQUIPMENT EXECUTION SITE SECURITY EMERGENCY PLANNING WORK SCHEDULE PREPARATION OF WORK AREA DISPOSAL OF WASTE MATERIALS DAMAGES CLEARANCE TESTING AND STANDARDS ABATEMENT OF LBP COMPONENTS APPENDICES APPENDIX A - APPENDIX B - APPENDIX C - APPENDIX D - MAP(S) XRF FIELD DATA PROJECT MONITOR / INSPECTOR / RISK ASSESSOR CERTIFICATE(S) INSURANCE CERTIFICATES B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

3 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page GENERAL 1.01 SUMMARY OF THE SCOPE OF WORK 1. A lead-based paint inspection by Barr & Clark Environmental on June 20, 2017 in accordance with EPA and HUD guidelines was prepared for the sole use of the City of Pomona and any regulatory agencies directly involved with the project. No other party should rely on the information contained within this report, without the prior written consent of the City of Pomona. 2. These specifications are for the above mentioned property located in Pomona, CA. The scope covered herein is for LEAD ABATEMENT only. It is not intended to be used for any other work scheduled. 3. The abatement activities will be coordinated with and integrated into planned rehabilitation activities for this property STANDARDS AND GUIDELINES 1. The current issues of each document shall govern, and where conflicts may exist, the more stringent requirements shall apply. 2. The Contractor shall assume full responsibility and liability for compliance with all Federal, State and local regulations pertaining to lead abatement on this project including medical examinations, monitoring and personal protective measures. 3. The Contractor shall indemnify the Owner and his Representative and save from any and all losses, costs and expenses including fines, judgments and reasonable attorney s fees incurred by the Owner for negligence on the part of the Contractor or any of his agents, whether accidental or intentional. 4. Compliance with the requirements of the applicable standards will be strictly enforced by the Owner or the Owner s Representative. 5. The Contractor shall comply with all provisions and/or responsibilities, as applicable, contained in the Guidelines for the Evaluation and Control of Lead-based Paint Hazards in Housing, June 1995, Department of Housing and Urban Development and with Federal OSHA Sec B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

4 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page 4 6. The Contractor shall comply with the requirements of the California General Industry Safety and Health Standards, and the Safety and Health Regulations for Construction, Title 8, California Code of Regulations (CCR) including but not limited to the following sections: Sec Sec Sec. 1637, 1640, 1658 Sec Sec Sec Sec & 3220 Sec Sec Sec. 1684, 3555 & 3556 Sec Sec Sec Sec & 3366 Sec Sec & 5143 Sec Sec Sec Sec Sec Respiratory Protection Electrical Scaffolding Housekeeping Hazard Communication (Employee Right to Know) Ladders Egress & Emergency Plans Protective Equipment Sanitation Powered Hand Tools Contractors Responsibility General Safety & Health Education Safety Training & Education Washing Facilities Gases, Vapors, Fumes, Dusts and Mists Ventilation Injury and Illness Prevention Program Access to Employee s Exposure and Medical Records Accident Prevention Signs Fire Prevention Plan Ventilation, Welding, Cutting or Heating of Metals of Toxic Significance 7. The Contractor shall comply with the Federal Environmental Protection Regulations pertaining to disposal of lead-containing materials as well the State of California and any local agencies which have delegated responsibility for the administration and enforcement of Federal Regulations. 8. The Contractor shall comply with all requirements of the EPA-approved landfill, which is selected as the disposal site and with RCRA waste requirements B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

5 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page OWNER S REPRESENTATIVE 1. The Owner may secure the services of an independent third party to monitor the work activities of the abatement Contractor. 2. The Representative shall have sufficient experience with similar projects and be certified as a Project Monitor with the State of California Department of Health Services. 3. The Representative may conduct visual inspections of the work area before, during, and after abatement activities. 4. The Representative may inspect the site preparation and submittals, and give approval for work to proceed on behalf of the owner and may inspect the removal work and work area upon completion, and give final visual clearance before the Contractor may proceed with the next phase of work. 5. Inspections may be on a daily basis, or randomly as needed to insure the Owner s interest. 6. The Representative may take field samples as needed for clearance purposes SUBMITTALS AND NOTICES 1. Within seven (7) calendar days after notice to proceed, the Contractor will provide to the Owner or Owner s Representative the following: a. All required permits for lead abatement work and/or disposal of potentially-hazardous wastes and construction debris including but not limited to, the following: b. Designated transporter s licenses and insurance certificates. c. Designated waste disposal facility certifications/licenses. d. Shop drawing indicating areas to be used for Staging of equipment and decon facilities, storage areas etc. e. Abatement work plan. f. A written respiratory protection plan as required by 29 CFR g. A written medical examination including all items required by 29 CFR h. Employee training certifications for lead exposure for every employee expected to be on this job. i. Weekly work schedule. j. Manufacturer s information, including MSDS, for all materials and worker protection equipment. k. Copies of all OSHA Form 101 reports or equivalent B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

6 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page QUALIFICATIONS 2.01 CONTRACTOR 1. The contractor shall be currently licensed for the intended activities with the California Contractors State License Board (CSLB). 2. The Contractor performing the LBP abatement work shall have a minimum of one (1) year of experience performing LBP removal or abatement work on similar projects in scope and size. Documented proof of past experience will be requested consisting of a list of projects with references for confirmation. Insurance, according to the Owner s requirements, including workers compensation, general liability and abatement liability in the amount of $500,000 per occurrence and $1,000,000 aggregate shall be provided. 3. The Contractor performing the work must be familiar with all applicable regulations covering LBP removal work. This includes all permits, licenses, and certifications required to perform this type of hazardous work as well as related disposal requirements. 4. The contractor shall employ at least one individual who has received certification as a California Department of Health Services Contractor/Supervisor WORKERS 1. All personnel must have minimum training, as established by the EPA-sanctioned emergency LBP Worker Training Standards, and in accordance with CFR All abatement workers on this project must also be certified through the State of California Department of Health Services, as a Lead Worker MATERIALS 1. Encapsulants - All encapsulating materials must have ASTM certification. All applications must be according to manufacturer s specifications. Any encapsulant without ASTM certification must receive approval in writing from either the owner or owner s representative. 2. Primers - All paint primers used on this job must be suitable for the intended substrate and compatible with the underlying paint and the intended paint. All applications must be according to manufacturer s specifications. 3. Color s - Any coating used as the final coating must have the color approved by the owner or owner s representative prior to application. 4. Architectural Component s - Any component that is replaced by the abatement contractor must be approved by the owner or owner s representative prior to installation B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

7 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page WORKER HEALTH AND SAFETY 3.01 MEDICAL SURVEILLANCE 1. Workers must be properly trained and fitted in the care, use, and maintenance of respirators, with fit tests performed every 6 months. 2. A formal respiratory protection program must be implemented in accordance with 29 CFR PERSONAL PROTECTIVE EQUIPMENT 1. The minimum respiratory protection required for this project is as follows: a. Negative pressure half face air purifying respirators equipped with HEPA filters for airborne lead levels not in excess of 500 g/m 3 (10 X pel 1 ). 2. All workers in the LBP abatement area will wear the proper respirator for the lead concentration generated. 3. Disposable suits with hoods and booties shall be worn at all times that lead abatement is taking place. Goggles with a side shield are to be worn when working with power tools or liquid materials that could injure the eyes. 4. Additional respirator filters or protective clothing may be needed when using chemicals. Consult MSDS for requirements. 4.0 EXECUTION 4.01 SITE SECURITY 1. Contractor shall be responsible for all security related to all work and storage areas. 2. All Hazardous materials must be stored in enclosed and locked areas at the end of each work shift, and when no personnel are present. This area must be labeled, in English and Spanish, with proper warning labels. 3. The Contractor shall maintain control of the site security at all times during the course of work to protect the work area and equipment, Contractor shall also be responsible for the proper storage and security of all equipment and materials left on site during off hours. 1 Permissible Exposure Level B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

8 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page EMERGENCY PLANNING 1. Emergency planning and procedures shall be developed by the Contractor, and presented in written form, and prominently posted and approved by the Owner or his Representative, and shall include: a. Written notification to Police, Fire, and Emergency Medical personnel of planned lead abatement activities. b. Work schedules and layout of barriers which could impede response capabilities. c. Emergency telephone numbers, and locations of nearest emergency facilities, posted for all workers to see easily. d. Evacuation procedures shall also be written, and posted with the signatures of all workers, to acknowledge their receipt of training in such procedures WORK SCHEDULE 1. The Contractor shall furnish to the Owner or his Representative a schedule showing the anticipated starting and completion dates for each phase or area of abatement. The schedule shall be furnished seven (7) calendar days from issuance of the Owner s written Notice to Proceed. This schedule shall be reviewed weekly and updated as required. The work shall be carried out diligently to completion. 2. If it becomes necessary to maintain the projected schedule, the Owner may request additional manpower to complete the work on time. The Contractor is obligated to comply with this written request from the Owner or his Representative. 3. Site work shall begin immediately upon the Owner s approval of Contractor s LBP Work Plan. A pre-abatement safety meeting shall be held before beginning work. 4. During the abatement, other work can be phased and coordinated to facilitate the completion of concurrent projects PREPARATION OF WORK AREA 1. Preparation of the work area is dependent on the type of abatement to be performed, the expected levels of airborne lead concentrations, and is subject to change if the lead concentrations exceed anticipated levels. 2. The Contractor is responsible for the posting of all warning signs and submittals at the entrances and exits to the work area. 3. The Owner will provide all necessary power and water unless otherwise specified in writing. 4. A two-stage decontamination (decon) area, consisting of a clean room with sufficient wash facilities and a tool room/work area, shall be provided. A mini-containment system may be used for abatement consisting of the following, but not limited to: B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

9 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page 9 a. (2) Layers of 6 mil polyethylene (poly) on floors where removal is needed. b. Critical barriers around the inside of all windows throughout. c. Z flaps over the entrances to all areas where removal occurs. d. Pre-Cleaning of interior by HEPA vacuuming and wet wiping with TSP throughout. 5. Sufficient signage in the form of pre-printed barrier tape shall be placed around the perimeter of the immediate work area in such a way as to prevent accidental encroachment by unauthorized personnel. 6. For exterior abatement, a double layer of 6 mil poly shall be securely attached to the perimeter of the building, at a minimum distance of 10 feet where possible. This barrier may be attached in increments as work progresses around the building. All poly will be removed daily and cleaned and disposed of properly before leaving the work site. In the event of winds in excess of 20 mph, work will stop and all debris cleaned up immediately. 7. No work may proceed without the approval of the Owner or his Representative after all preparation has been met. 8. Toilet facilities sufficient for the number of workers on this project shall be the responsibility of the Contractor. 9. Disposal bins of the proper type shall be the responsibility of the Contractor and shall be securely locked at the end of each day. All bins upon being filled shall be removed to the proper landfill as soon as possible. 10. A secure, locked storage area for all volatile chemicals is to be used. 11. In addition the Contractor must comply with the directions of the Owner or the Owner s Representative as the situation dictates B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

10 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page DISPOSAL OF WASTE MATERIALS 1. Building components on which the lead based paint is intact may be disposed of as nonhazardous construction debris, according to EPA and Cal EPA officials. 2. The following materials may be classified as non-hazardous for this project. The Owner or his Representative may reverse this presumption, based on contractor work practices or test results. a. Disposable work clothes and respirator filters. b. Filtered wash water. c. Wet-wiped or HEPA-vacuumed plastic sheeting. 3. The following materials are presumed to be hazardous. a. Paint chips b. HEPA vacuum debris and filters, dust from air filters and paint dust. c. Unfiltered liquid waste. d. Sludge from stripping. e. Rags, sponges, mops, scrapers and other materials used. 4. It is the responsibility of the Contractor to comply with all RCRA, EPA and DOT regulations and any State or local regulations. In the case of conflict, the more stringent rule applies. 5. The contractor will be responsible for assisting the property owner in obtaining and completing all relevant permits, licenses, manifests, etc. for hazardous waste disposal DAMAGES 1. The Contractor shall be responsible for the protection of all areas impacted by the scope of work, and the areas adjacent to substrates that are disturbed or damaged by this work. Damages to non-protected areas, either accidental or from lack of due diligence, shall be repaired or replaced at the Abatement Contractor s expense B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

11 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page CLEARANCE TESTING AND STANDARDS Two separate post abatement clearance inspections will be conducted at this property. The first inspection will consist of a visual inspection to verify that all lead related work was completed as specified. After passing the visual inspection, the general contractor will be allowed to begin general construction activities. The second inspection will consist of collecting wipe samples to quantify the amount of residual lead in dust that remains on horizontal surfaces. Since this second test will be conducted after general construction activities, THE ABATEMENT CONTRACTOR SHOULD PLAN ON PERFORMING FINAL CLEAN-UP ACTIVITIES AFTER ALL CONSTRUCTION HAS BEEN COMPLETED. 1. After the abatement, clean-up, and waste removal, the Owner, Owner s representative, or General Contractor will conduct a visual inspection before any other rehabilitation activities begin. It is strongly recommended that the Abatement Contractor is present for this inspection. 2. The visual inspection will: Verify that visible dust or paint chips are not present in any of the work areas or adjacent to the work areas. Verify that all work was completed as specified. Survey any collateral damages caused by the abatement contractor and establish a timetable for repairs. 3. Clearance samples will be collected by the Owner or Owner s Representative after ALL construction activities have been completed. Clearance samples shall be taken according to HUD LBP Guidelines and analyzed by a qualified laboratory. The cost of initial clearance sampling will be the responsibility of the client. 4. Wipe sample clearance is as follows (see note*): a. Interior Floors 10 µg / ft 2 (micrograms per square foot) b. Interior Window Sills 100 µg / ft 2 c. Window Wells/Troughs 100 µg / ft 2 d. Exterior Porches/Floors 40 µg / ft 2 *NOTE: Per the U.S. Department of Housing and Urban Development (HUD) Guidelines for the Evaluation and Control of Lead-Based Paint Hazards (Office of Healthy Homes and Lead Hazard Control Second Edition, July 2012), if Federal standards differ from State, Tribal or local standards, the most stringent (protective) standards must be applied. The U.S. Department of Housing and Urban Development (HUD) has revised the Dust-Lead Action Levels for Risk Assessment and Clearance; Clearance of Porch Floors (Policy Guidance Number: Date: January 31, 2017). Effective April 1, 2017, the following lead dust hazard and clearance action levels (or lower levels if required by their state regulations) should be followed: B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

12 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page 12 New Lead Dust Hazard Action Levels: Floors: 10 μg/ft2 and Window Sills: 100 μg/ft2, New Lead Clearance Action Levels: Interior Floors: <10 μg/ft2; Porch Floors: <40 μg/ft2, Window Sills: <100 μg/ft2, and Window Troughs: <100 μg/ft2 5. Depending on the nature of the abatement and the types of methods employed, other clearance criteria may be established before the work begins. 6. If the test results are higher than permissible, the Abatement Contractor will be directed to re-clean until acceptable levels are met. The cost of any subsequent clearance inspections (including re-sampling costs) will be charged back to the abatement contractor through the property owner B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

13 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page ABATEMENT OF LBP COMPONENTS The following treatments, except as noted on a room by room basis, will be utilized at this property. Removal - The specified component(s) will be removed. Removal must be done in a manner that minimizes damage to adjacent surfaces. ANY REMOVAL OF DOORS OR WINDOWS MUST BE COORDINATED WITH THE GENERAL CONTRACTOR (GC) SO THAT THE PROPERTY IS NOT LEFT UNSECURED. Enclosure - The specified surface shall be enclosed with a durable building material that is suitable for the intended application. Encapsulation - All loose paint will be removed followed by covering with an acceptable encapsulant. Any surface treated in this manner MUST BE PAINT READY. Paint Removal - All paint on the specified component must be removed down to bare substrate followed by sealing with a high quality primer that is compatible with the underlying substrate and the intended paint. Paint Stabilization (Intacting) - All loose and peeling paint that can be lifted with thumbnail pressure will be removed. Any nails, screws, or other protrusions will be removed. All cavities/pits will be filled and sharp edges will be feathered. Any broken, rotten, or termite damaged wood shall be replaced. All affected areas will be sealed with a suitable encapsulant. All surfaces treated in this manner MUST BE PAINT READY. Sampling during the lead inspection/risk assessment was representative and any components that were not tested but similar to those components that tested positive for LBP should be considered and treated as lead laden B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

14 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page 14 Work Requested - 1) Building 1 - Exterior - Door Frame at the Electrical Room All paint on the friction portions of the lead-laden door components must be removed down to bare substrate. All loose and peeling paint that can be lifted with thumbnail pressure will be removed. Any nails, screws, or other protrusions will be removed. All cavities/pits will be filled and sharp edges will be feathered. This will be followed by sealing the door components with a suitable encapsulant. Any surface treated in this manner - MUST BE PRIMED AND REPAINTED. Alternatively - The lead-laden door components may be removed and replaced. Removal must be done in a manner that minimizes damage to adjacent surfaces. ANY REMOVAL OF DOOR COMPONENTS MUST BE COORDINATED WITH THE GENERAL CONTRACTOR (GC) SO THAT THE PROPERTY IS NOT LEFT UNSECURED. Estimated Cost $ $ 2) Building 1 - Exterior - Window Frames - All paint on the friction portions of the lead-laden window components must be removed down to bare substrate. All loose and peeling paint that can be lifted with thumbnail pressure will be removed from the entire window (friction and non-friction surfaces). Any nails, screws, or other protrusions will be removed. All cavities/pits will be filled and sharp edges will be feathered. This will be followed by sealing all areas of the window components with a suitable encapsulant. Any surface treated in this manner MUST BE PRIMED AND REPAINTED. Alternatively - The lead-laden window components may be removed and replaced. Removal must be done in a manner that minimizes damage to adjacent surfaces. ANY REMOVAL OF WINDOWS MUST BE COORDINATED WITH THE GENERAL CONTRACTOR (GC) SO THAT THE PROPERTY IS NOT LEFT UNSECURED. $ $ B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

15 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page 15 Work Requested - 3) Building 1 - Exterior - Metal Bollards on South Side - All loose and peeling paint that can be lifted with thumbnail pressure will be removed. Any nails, screws, or other protrusions will be removed. All cavities/pits will be filled and sharp edges will be feathered. Any broken, rotten, or termite damaged wood shall be replaced. All affected areas will be sealed with a suitable encapsulant. All surfaces treated in this manner MUST BE PRIMED AND REPAINTED. Estimated Cost $ 4) Building 1 Interior - Because the dust wipe samples indicated a level of lead above the specified regulatory limit, all floors, window sills, and window wells should be properly cleaned (HEPA / TSP Equivalent / HEPA). $ 5) Building 2 Interior Hall - Closet Shelf Supports Remove all closet shelf supports utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 6) Building 2 Interior Bathroom - Door Components Remove all door components utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 7) Building 2 Interior & Exterior Room 3 - Window Components Remove all casement window components utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 8) Building 2 Interior Room 3 - Wood Wall ( A Side White) Remove the wood wall utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

16 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page 16 Work Requested - Estimated Cost 9) Building 2 Exterior - Door Frame at Room 1 Remove the door frame utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 10) Building 2 Exterior Eaves, Rafters & Fascia Remove the eaves, rafters and fascia utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 11) Building 2 Exterior Corner Boards Remove the corner boards utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 12) Building 2 Exterior Window Components Remove the window components utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 13) Building 2 Exterior Beams at East Side Porch Remove the beams utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 14) Building 3 Interior & Exterior Room 2 Door Frame (Northeast Doorway) Remove the door frame utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

17 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page 17 Work Requested - Estimated Cost 15) Building 3 Exterior Window Components Remove the window components utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 16) Building 3 Exterior Wooden Walls & Corner Boards Remove the wooden walls and corner boards utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 17) Building 3 Exterior Eaves, Rafters & Fascia Remove the eaves, rafters and fascia utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 18) Building 3 Exterior Vents (Upper) Remove the vents utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 19) Building 3 Exterior Columns, Beams & Ceilings at the Patio and West Porch Remove the columns, beams and ceilings utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 20) Building 4 Exterior Door Frames to Room 1 & Room 2 Remove the door frames utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

18 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page 18 Work Requested - Estimated Cost 21) Building 4 Exterior Window Components Remove the window components utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 22) Building 4 Exterior Eaves, Rafters & Fascia Remove the eaves, rafters and fascia utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 23) Building 4 Exterior Columns at Patio Remove the columns utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 24) Building 4 Exterior Vents Remove the vents utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 25) Building 4 Exterior Bollards on East Side Remove the bollards utilizing proper abatement, containment, clean up and disposal procedures. These items should be segregated for lead waste characterization analysis for disposal purposes. *See the Waste Characterization Testing Flow Chart below. 26) Waste Disposal (Hazardous & Non-hazardous) $ 27) Total Lead Abatement Cost $ B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

19 Lead Based Paint Abatement Specifications 5 Buildings 1400 E. Mission Boulevard Project Number Page 19 All work must be in compliance with these Abatement Specifications, current HUD Guidelines, and California DHS/CDPH Title 17. Any additional work or changes that the Contractor deems appropriate to enhance the competitiveness of this bid may be added as an addendum to this form. Please fill out all requested information that follows: Company Name: Company Phone #: Contact Person: Date of Bid: Total amount of Bid: $ Estimated Time of Completion: I hereby acknowledge that any work performed by on the above listed property will be done in compliance with these abatement specifications as well as all laws and regulations governing this type of activity. Authorized Signature B o l s a C h i c a, S u i t e H u n t i n g t o n B e a c h, C A w w w. b a r r a n d c l a r k. c o m

20 NOTE: mg/kg = ppm *Waste Characterization Testing Flow Chart

21 APPENDIX A MAP(S)

22 SITE MAP C BUILDING 5 BUILDING 4 B D BUILDING 3 BUILDING 1 BUILDING 2 A N E. Mission Boulevard Pomona Project#

23 BUILDING 1 C AL TR DH FH BATHROOM ROOM 2 ROOM 3 B D HALLWAY AL ROOM 1 ROOM 4 ROOM 5 AL AL AL DH AL AL FX Window Key: AL = Aluminum DH = Double Hung TR = Transom A E. Mission Boulevard Pomona Project# N

24 C BUILDING 2 CS CS DH ROOM 3 ROOM 4 DH B DH D ROOM 1 HALLWAY BATHROOM DH CL ROOM 2 FX Window Key: CS = Casement DH = Double Hung FX = Fixed A E. Mission Boulevard Pomona Project# N

25 C BUILDING 3 FX DH DH AL BATHROOM 1 AL ROOM 4 HALLWAY B D ROOM 2 ROOM 3 FX CS AL AL ROOM 1 BATHROOM 2 FX DH A N Window Key: AL = Aluminum CS = Casement DH = Double Hung FX = Fixed E. Mission Boulevard Pomona Project#

26 C BUILDING 4 FX AL FX ROOM 3 ROOM 4 ROOM 5 FX DH AL BATHROOM 2 CS HALLWAY BATHROOM 1 DH B D ROOM 2 DH FX ROOM 1 FX A N Window Key: AL = Aluminum CS = Casement DH = Double Hung FX = Fixed E. Mission Boulevard Pomona Project#

27 BUILDING 5 C B MAIN ROOM D E. Mission Boulevard Pomona Project# A N

28 APPENDIX B XRF FIELD DATA

29 Project Name:5 Buildings Address:1400 E. Mission Boulevard Pomona CA, Component SUMMARY OF INTERIOR Number Tested Number Positive Percent Positive Number Negative Percent Negative Acoustic Ceiling Concrete Floor Gypsum Attic Access Gypsum Ceiling Gypsum Wall Gypsum Window Sill Metal Closet Door Metal Door Metal Electrical Panel Metal Heater Vent Metal Trim Plaster Ceiling Plaster Wall Tile Floor Tile Wall Wood Attic Access Wood Attic Access Frame Wood Baseboard Wood Beam Wood Cabinet Door Wood Cabinet Frame Wood Cabinet Shelf Wood Ceiling Wood Closet Door Frame Wood Closet Shelf Wood Closet Shelf Support % % Wood Counter Top Wood Crown Molding Wood Deck Wood Door % % Wood Door Frame % % Wood Frame Wood Horizontal Trim Wood Shelf Wood Shelf Supports Wood Stringer Wood Tread Wood Wall % % Wood Window Frame % % Testing done in compliance with current L.A. County DHS guidelines for XRF. 1 6/22/2017 2:26:44 PM

30 Project Name:5 Buildings Address:1400 E. Mission Boulevard Pomona CA, Component Wood Window Sash % % Wood Window Sill % % Totals: SUMMARY OF INTERIOR Number Tested Number Positive Percent Positive Number Negative Percent Negative Testing done in compliance with current L.A. County DHS guidelines for XRF. 2 6/22/2017 2:26:44 PM

31 Project Name:5 Buildings Address:1400 E. Mission Boulevard Pomona CA, Component SUMMARY OF EXTERIOR Number Tested Number Positive Percent Positive Number Negative Percent Negative Asphalt Parking Stripe Concrete Floor Concrete Trim Metal Access Panel Metal Awning Metal Beam Metal Bollard % % Metal Ceiling Metal Column Metal Door Metal Door Frame Metal Downspout Metal Electric Utility Box Metal Fire Ext. Box Metal Garage Door Metal Gutter Metal Pipe Metal Post Metal Roof Trim Metal Trim Metal Vent Metal Wall Metal Window Bars Metal Window Frame Stucco Ceiling Stucco Wall Vinyl Gutter Wood Beam % % Wood Bench Wood Ceiling % % Wood Column % % Wood Corner Board % % Wood Door Wood Door Frame % % Wood Eaves % % Wood Fascia % % Wood Frame Wood Garage Door Frame Wood Horizontal Trim Testing done in compliance with current L.A. County DHS guidelines for XRF. 3 6/22/2017 2:26:44 PM

32 Project Name:5 Buildings Address:1400 E. Mission Boulevard Pomona CA, Component Wood Lattice Wood Post Wood Rafters % % Wood Trim Wood Vent Wood Vertical Trim Wood Wall % % Wood Window Frame % % Wood Window Sash % % Wood Window Well % % Totals: SUMMARY OF EXTERIOR Number Tested Number Positive Percent Positive Number Negative Percent Negative Testing done in compliance with current L.A. County DHS guidelines for XRF. 4 6/22/2017 2:26:44 PM

33 Project Name:5 Buildings Address:1400 E. Mission Boulevard Pomona CA, Component Wood 0.0 mg/cm2 Standard Wood 1.0 mg/cm2 Standard Totals: SUMMARY OF COMMON Number Tested Number Positive Percent Positive Number Negative Percent Negative Testing done in compliance with current L.A. County DHS guidelines for XRF. 5 6/22/2017 2:26:44 PM

34 LEAD CONTAINING COMPONENTS LIST

35 Interior Lead Containing Components List Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Side Testing Combination Room Equivalent Lead Results Condition Comments 217 A Wood Closet Shelf Support Building 2 Interior Hall 0.7 POSITIVE Intact 223 B Wood Door Building 2 Interior Bathroom 0.9 POSITIVE Intact 224 B Wood Door Frame Building 2 Interior Bathroom 1.2 POSITIVE DETERIORATED 260 C Wood Window Sill Building 2 Interior Room POSITIVE DETERIORATED Casement 263 D Wood Window Sill Building 2 Interior Room POSITIVE Intact Casement 264 D Wood Window Sash Building 2 Interior Room POSITIVE Intact Casement 265 D Wood Window Frame Building 2 Interior Room POSITIVE Intact Casement 266 A Wood Wall Building 2 Interior Room POSITIVE Intact White 367 B Wood Door Frame Building 3 Interior Room POSITIVE DETERIORATED 400 C Wood Window Sash Building 3 Interior Bathroom POSITIVE Intact Double Hung L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 1 of 6 6/22/2017 2:26:45 PM

36 Exterior Lead Containing Components List Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Side Testing Combination Room Equivalent Lead Results Condition Comments 159 C Wood Door Frame Building 1 Perimeter Exterior South Side 0.7 POSITIVE DETERIORATED Electrical Room 161 C Wood Window Frame Building 1 Perimeter Exterior South Side 1.4 POSITIVE DETERIORATED Aluminum 164 C Wood Window Frame Building 1 Perimeter Exterior South Side 0.7 POSITIVE DETERIORATED Plywood 167 C Wood Window Frame Building 1 Perimeter Exterior South Side 0.7 POSITIVE DETERIORATED Double Hung 180 C Metal Bollard Building 1 Perimeter Exterior South Side 2.4 POSITIVE DETERIORATED 181 C Metal Bollard Building 1 Perimeter Exterior South Side 2.5 POSITIVE DETERIORATED 185 D Wood Window Frame Building 1 Perimeter Exterior West Side 0.7 POSITIVE DETERIORATED Double Hung 200 B Wood Door Frame Building 2 Exterior Room POSITIVE DETERIORATED 292 A Wood Eaves Building 2 Perimeter Exterior North Side 3.2 POSITIVE DETERIORATED 293 A Wood Fascia Building 2 Perimeter Exterior North Side 0.7 POSITIVE DETERIORATED 294 A Wood Corner Board Building 2 Perimeter Exterior North Side 2.5 POSITIVE DETERIORATED 295 B Wood Window Well Building 2 Perimeter Exterior East Side 1.3 POSITIVE DETERIORATED Double Hung 296 B Wood Window Sash Building 2 Perimeter Exterior East Side 1.3 POSITIVE DETERIORATED Double Hung 297 B Wood Window Frame Building 2 Perimeter Exterior East Side 1.1 POSITIVE DETERIORATED Double Hung 299 B Wood Window Well Building 2 Perimeter Exterior East Side 1.0 POSITIVE DETERIORATED Double Hung 300 B Wood Window Sash Building 2 Perimeter Exterior East Side 1.5 POSITIVE DETERIORATED Double Hung 301 B Wood Window Frame Building 2 Perimeter Exterior East Side 1.2 POSITIVE DETERIORATED Double Hung 304 B Wood Eaves Building 2 Perimeter Exterior East Side 1.0 POSITIVE DETERIORATED 305 B Wood Rafters Building 2 Perimeter Exterior East Side 1.3 POSITIVE DETERIORATED 306 B Wood Eaves Building 2 Perimeter Exterior East Side 1.5 POSITIVE DETERIORATED 307 B Wood Fascia Building 2 Perimeter Exterior East Side 1.0 POSITIVE DETERIORATED 308 B Wood Beam Building 2 Perimeter Exterior East Side 4.1 POSITIVE DETERIORATED Side Porch 318 C Wood Window Frame Building 2 Perimeter Exterior South Side 0.9 POSITIVE DETERIORATED No Window 324 C Wood Eaves Building 2 Perimeter Exterior South Side 1.6 POSITIVE DETERIORATED 325 C Wood Rafters Building 2 Perimeter Exterior South Side 1.2 POSITIVE DETERIORATED 326 C Wood Fascia Building 2 Perimeter Exterior South Side 1.0 POSITIVE DETERIORATED 327 C Wood Eaves Building 2 Perimeter Exterior South Side 1.2 POSITIVE DETERIORATED 328 C Wood Fascia Building 2 Perimeter Exterior South Side 1.3 POSITIVE DETERIORATED 332 D Wood Window Frame Building 2 Perimeter Exterior West Side 2.9 POSITIVE DETERIORATED No Window L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 2 of 6 6/22/2017 2:26:45 PM

37 Exterior Lead Containing Components List Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Side Testing Combination Room Equivalent Lead Results Condition Comments 334 D Wood Window Well Building 2 Perimeter Exterior West Side 4.7 POSITIVE DETERIORATED Double Hung 336 D Wood Window Frame Building 2 Perimeter Exterior West Side 0.7 POSITIVE Intact Double Hung 342 D Wood Eaves Building 2 Perimeter Exterior West Side 1.6 POSITIVE DETERIORATED 343 D Wood Rafters Building 2 Perimeter Exterior West Side 1.5 POSITIVE DETERIORATED 344 D Wood Eaves Building 2 Perimeter Exterior West Side 1.2 POSITIVE DETERIORATED 348 D Wood Corner Board Building 2 Perimeter Exterior West Side 9.9 POSITIVE DETERIORATED 365 B Wood Door Frame Building 3 Exterior Room POSITIVE DETERIORATED 456 A Wood Window Well Building 3 Perimeter Exterior North Side 2.8 POSITIVE DETERIORATED Aluminum 457 A Wood Window Frame Building 3 Perimeter Exterior North Side 1.6 POSITIVE DETERIORATED Aluminum 459 A Wood Wall Building 3 Perimeter Exterior North Side 0.7 POSITIVE DETERIORATED 460 A Wood Wall Building 3 Perimeter Exterior North Side 0.7 POSITIVE DETERIORATED 464 A Wood Rafters Building 3 Perimeter Exterior North Side 1.3 POSITIVE DETERIORATED 465 A Wood Eaves Building 3 Perimeter Exterior North Side 1.3 POSITIVE DETERIORATED 466 A Wood Rafters Building 3 Perimeter Exterior North Side 1.2 POSITIVE DETERIORATED 467 A Wood Fascia Building 3 Perimeter Exterior North Side 0.9 POSITIVE DETERIORATED 468 A Wood Eaves Building 3 Perimeter Exterior North Side 2.1 POSITIVE DETERIORATED 469 A Wood Fascia Building 3 Perimeter Exterior North Side 1.3 POSITIVE DETERIORATED 472 A Wood Vent Building 3 Perimeter Exterior North Side 0.7 POSITIVE DETERIORATED Upper 473 A Wood Corner Board Building 3 Perimeter Exterior North Side 0.7 POSITIVE DETERIORATED 475 B Wood Window Well Building 3 Perimeter Exterior East Side 2.0 POSITIVE DETERIORATED Boarded Up 476 B Wood Window Frame Building 3 Perimeter Exterior East Side 1.3 POSITIVE DETERIORATED Boarded Up 477 B Wood Wall Building 3 Perimeter Exterior East Side 1.0 POSITIVE DETERIORATED 478 B Wood Wall Building 3 Perimeter Exterior East Side 1.0 POSITIVE DETERIORATED 479 B Wood Wall Building 3 Perimeter Exterior East Side 1.2 POSITIVE DETERIORATED 480 B Wood Wall Building 3 Perimeter Exterior East Side 1.0 POSITIVE DETERIORATED 481 B Wood Eaves Building 3 Perimeter Exterior East Side 0.9 POSITIVE DETERIORATED 482 B Wood Fascia Building 3 Perimeter Exterior East Side 0.9 POSITIVE DETERIORATED 483 B Wood Column Building 3 Perimeter Exterior East Side 0.9 POSITIVE DETERIORATED Patio 484 B Wood Beam Building 3 Perimeter Exterior East Side 2.0 POSITIVE DETERIORATED Patio L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 3 of 6 6/22/2017 2:26:45 PM

38 Exterior Lead Containing Components List Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Side Testing Combination Room Equivalent Lead Results Condition Comments 485 B Wood Ceiling Building 3 Perimeter Exterior East Side 0.9 POSITIVE DETERIORATED Patio 487 C Wood Window Well Building 3 Perimeter Exterior South Side 1.3 POSITIVE DETERIORATED Aluminum 488 C Wood Window Frame Building 3 Perimeter Exterior South Side 1.4 POSITIVE DETERIORATED Aluminum 494 C Wood Window Sash Building 3 Perimeter Exterior South Side 0.7 POSITIVE DETERIORATED Double Hung 498 C Wood Wall Building 3 Perimeter Exterior South Side 1.6 POSITIVE DETERIORATED 499 C Wood Wall Building 3 Perimeter Exterior South Side 1.5 POSITIVE DETERIORATED 500 C Wood Wall Building 3 Perimeter Exterior South Side 1.5 POSITIVE DETERIORATED 501 C Wood Wall Building 3 Perimeter Exterior South Side 1.4 POSITIVE DETERIORATED 502 C Wood Eaves Building 3 Perimeter Exterior South Side 1.2 POSITIVE DETERIORATED 503 C Wood Fascia Building 3 Perimeter Exterior South Side 1.0 POSITIVE DETERIORATED 504 C Wood Eaves Building 3 Perimeter Exterior South Side 1.4 POSITIVE DETERIORATED 505 C Wood Rafters Building 3 Perimeter Exterior South Side 1.4 POSITIVE DETERIORATED 506 C Wood Fascia Building 3 Perimeter Exterior South Side 0.7 POSITIVE DETERIORATED 507 C Wood Vent Building 3 Perimeter Exterior South Side 1.0 POSITIVE DETERIORATED Upper 512 D Wood Window Frame Building 3 Perimeter Exterior West Side 2.3 POSITIVE DETERIORATED Aluminum 514 D Wood Wall Building 3 Perimeter Exterior West Side 1.2 POSITIVE DETERIORATED 515 D Wood Wall Building 3 Perimeter Exterior West Side 1.2 POSITIVE DETERIORATED 516 D Wood Wall Building 3 Perimeter Exterior West Side 1.3 POSITIVE DETERIORATED 517 D Wood Wall Building 3 Perimeter Exterior West Side 1.4 POSITIVE DETERIORATED 518 D Wood Eaves Building 3 Perimeter Exterior West Side 1.2 POSITIVE DETERIORATED 519 D Wood Rafters Building 3 Perimeter Exterior West Side 1.3 POSITIVE DETERIORATED 520 D Wood Fascia Building 3 Perimeter Exterior West Side 0.9 POSITIVE DETERIORATED 522 D Wood Beam Building 3 Perimeter Exterior West Side 0.7 POSITIVE DETERIORATED Porch 523 D Wood Ceiling Building 3 Perimeter Exterior West Side 0.7 POSITIVE DETERIORATED Porch 524 D Wood Corner Board Building 3 Perimeter Exterior West Side 1.4 POSITIVE DETERIORATED 534 A Wood Door Frame Building 4 Exterior Room POSITIVE DETERIORATED 548 C Wood Door Frame Building 4 Exterior Room POSITIVE DETERIORATED 650 A Wood Window Well Building 4 Perimeter Exterior North Side 0.7 POSITIVE Intact Boarded Up 651 A Wood Window Frame Building 4 Perimeter Exterior North Side 0.7 POSITIVE DETERIORATED Boarded Up L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 4 of 6 6/22/2017 2:26:45 PM

39 Exterior Lead Containing Components List Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Side Testing Combination Room Equivalent Lead Results Condition Comments 657 A Wood Eaves Building 4 Perimeter Exterior North Side 1.5 POSITIVE DETERIORATED 658 A Wood Fascia Building 4 Perimeter Exterior North Side 1.0 POSITIVE DETERIORATED 665 B Wood Window Well Building 4 Perimeter Exterior East Side 1.0 POSITIVE DETERIORATED Fixed 666 B Wood Window Sash Building 4 Perimeter Exterior East Side 0.7 POSITIVE DETERIORATED Fixed 667 B Wood Window Frame Building 4 Perimeter Exterior East Side 1.3 POSITIVE DETERIORATED Fixed 671 B Wood Window Frame Building 4 Perimeter Exterior East Side 0.7 POSITIVE Intact Boarded Up 676 B Wood Eaves Building 4 Perimeter Exterior East Side 1.2 POSITIVE DETERIORATED 677 B Wood Rafters Building 4 Perimeter Exterior East Side 1.3 POSITIVE DETERIORATED 678 B Wood Column Building 4 Perimeter Exterior East Side 1.1 POSITIVE DETERIORATED Patio 687 B Wood Vent Building 4 Perimeter Exterior East Side 0.7 POSITIVE DETERIORATED 689 B Metal Bollard Building 4 Perimeter Exterior East Side 1.2 POSITIVE DETERIORATED 690 B Metal Bollard Building 4 Perimeter Exterior East Side 1.3 POSITIVE DETERIORATED 699 C Wood Window Frame Building 4 Perimeter Exterior South Side 1.4 POSITIVE DETERIORATED Aluminum 711 D Wood Window Well Building 4 Perimeter Exterior West Side 0.7 POSITIVE DETERIORATED Boarded Up 712 D Wood Window Frame Building 4 Perimeter Exterior West Side 0.7 POSITIVE DETERIORATED Boarded Up 717 D Wood Window Sash Building 4 Perimeter Exterior West Side 0.7 POSITIVE DETERIORATED Double Hung 718 D Wood Window Frame Building 4 Perimeter Exterior West Side 0.9 POSITIVE DETERIORATED Double Hung 725 D Wood Eaves Building 4 Perimeter Exterior West Side 0.7 POSITIVE DETERIORATED 726 D Wood Rafters Building 4 Perimeter Exterior West Side 1.0 POSITIVE DETERIORATED 729 D Wood Vent Building 4 Perimeter Exterior West Side 0.7 POSITIVE Intact L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 5 of 6 6/22/2017 2:26:45 PM

40 Common Lead Containing Components List Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Side Testing Combination Room Equivalent Lead Results Condition Comments 4 Wood 1.0 mg/cm2 Standard Calibration Common Start of Job 1.0 POSITIVE Intact 5 Wood 1.0 mg/cm2 Standard Calibration Common Start of Job 1.1 POSITIVE Intact 6 Wood 1.0 mg/cm2 Standard Calibration Common Start of Job 1.0 POSITIVE Intact 798 Wood 1.0 mg/cm2 Standard Calibration Common End of Job 1.0 POSITIVE Intact 799 Wood 1.0 mg/cm2 Standard Calibration Common End of Job 1.0 POSITIVE Intact 800 Wood 1.0 mg/cm2 Standard Calibration Common End of Job 1.0 POSITIVE Intact L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 6 of 6 6/22/2017 2:26:45 PM

41 FIELD DATA

42 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 1 Calibration Common Start of Job 0.0 mg/cm2 Standard Wood Intact 0.1 Negative 2 Calibration Common Start of Job 0.0 mg/cm2 Standard Wood Intact 0.0 Negative 3 Calibration Common Start of Job 0.0 mg/cm2 Standard Wood Intact 0.0 Negative 4 Calibration Common Start of Job 1.0 mg/cm2 Standard Wood Intact 1.0 POSITIVE 5 Calibration Common Start of Job 1.0 mg/cm2 Standard Wood Intact 1.1 POSITIVE 6 Calibration Common Start of Job 1.0 mg/cm2 Standard Wood Intact 1.0 POSITIVE 7 Buidling 1 Exterior Room 1 A Door Wood Intact 0.2 Negative 8 Buidling 1 Exterior Room 1 A Door Frame Wood DETERIORATED 0.2 Negative 9 Building 1 Interior Room 1 A Door Wood Intact 0.0 Negative 10 Building 1 Interior Room 1 A Door Frame Wood DETERIORATED 0.1 Negative 11 Building 1 Interior Room 1 A Window Sill Wood Intact 0.2 Negative Aluminum 12 Building 1 Interior Room 1 A Window Frame Wood Intact 0.1 Negative Aluminum 13 Building 1 Interior Room 1 B Window Sill Wood Intact 0.3 Negative Aluminum 14 Building 1 Interior Room 1 B Window Frame Wood Intact 0.2 Negative Aluminum 15 Building 1 Interior Room 1 C Window Sill Wood Intact 0.0 Negative Aluminum 16 Building 1 Interior Room 1 C Window Frame Wood Intact 0.1 Negative Aluminum 17 Building 1 Interior Room 1 A Wall Plaster Intact 0.2 Negative 18 Building 1 Interior Room 1 B Wall Plaster Intact 0.2 Negative 19 Building 1 Interior Room 1 C Wall Plaster Intact 0.1 Negative 20 Building 1 Interior Room 1 D Wall Plaster Intact 0.1 Negative 21 Building 1 Interior Room 1 Ceiling Acoustic Intact 0.3 Negative 22 Building 1 Interior Room 1 Heater Vent Metal Intact 0.1 Negative 23 Building 1 Interior Hall A Door Wood Intact 0.1 Negative 24 Building 1 Interior Hall A Door Frame Wood DETERIORATED 0.2 Negative 25 Building 1 Interior Hall D Cabinet Frame Wood Intact 0.2 Negative 26 Building 1 Interior Hall D Cabinet Door Wood Intact 0.2 Negative 27 Building 1 Interior Hall D Cabinet Shelf Wood Intact 0.3 Negative 28 Building 1 Interior Hall A Wall Plaster Intact 0.2 Negative 29 Building 1 Interior Hall B Wall Plaster Intact 0.2 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 1 of 28 6/22/2017 2:26:46 PM

43 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 30 Building 1 Interior Hall C Wall Plaster Intact 0.1 Negative 31 Building 1 Interior Hall D Wall Plaster Intact 0.1 Negative 32 Building 1 Interior Hall Heater Vent Metal Intact 0.1 Negative 33 Building 1 Interior Hall Ceiling Acoustic Intact 0.1 Negative 1x1 Tiles 34 Building 1 Interior Hall Attic Access Wood Intact 0.0 Negative 35 Building 1 Interior Hall Attic Access Frame Wood Intact 0.1 Negative 36 Building 1 Exterior Room 2 B Door Metal DETERIORATED 0.0 Negative 37 Building 1 Exterior Room 2 B Door Frame Wood DETERIORATED 0.1 Negative 38 Building 1 Interior Room 2 B Door Metal Intact 0.0 Negative 39 Building 1 Interior Room 2 B Door Frame Wood Intact 0.1 Negative 40 Building 1 Interior Room 2 B Window Sill Wood Intact 0.0 Negative Fixed 41 Building 1 Interior Room 2 B Window Sash Wood Intact 0.1 Negative Fixed 42 Building 1 Interior Room 2 B Window Frame Wood Intact 0.1 Negative Fixed 43 Building 1 Interior Room 2 C Window Sill Wood Intact 0.2 Negative Aluminum 44 Building 1 Interior Room 2 C Window Frame Wood Intact 0.2 Negative Aluminum 45 Building 1 Interior Room 2 A Wall Plaster Intact 0.1 Negative 46 Building 1 Interior Room 2 B Wall Plaster Intact 0.2 Negative 47 Building 1 Interior Room 2 C Wall Plaster Intact 0.2 Negative 48 Building 1 Interior Room 2 D Wall Plaster Intact 0.1 Negative 49 Building 1 Interior Room 2 Heater Vent Metal Intact 0.0 Negative 50 Building 1 Interior Room 2 Ceiling Acoustic Intact 0.3 Negative 51 Building 1 Interior Room 2 D Trim Metal Intact 0.0 Negative 52 Building 1 Interior Room 2 Horizontal Trim Wood Intact 0.0 Negative 53 Building 1 Interior Bathroom A Door Wood Intact 0.0 Negative 54 Building 1 Interior Bathroom A Door Frame Wood DETERIORATED 0.1 Negative 55 Building 1 Interior Bathroom C Window Sash Wood DETERIORATED 0.1 Negative Transom 56 Building 1 Interior Bathroom C Window Frame Wood Intact 0.2 Negative Transom 57 Building 1 Interior Bathroom B Cabinet Frame Wood DETERIORATED 0.2 Negative 58 Building 1 Interior Bathroom B Cabinet Door Wood DETERIORATED 0.2 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 2 of 28 6/22/2017 2:26:46 PM

44 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 59 Building 1 Interior Bathroom B Cabinet Shelf Wood DETERIORATED 0.1 Negative 60 Building 1 Interior Bathroom A Wall Plaster Intact 0.3 Negative 61 Building 1 Interior Bathroom B Wall Plaster Intact 0.3 Negative 62 Building 1 Interior Bathroom C Wall Plaster Intact 0.2 Negative 63 Building 1 Interior Bathroom D Wall Plaster Intact 0.2 Negative 64 Building 1 Interior Bathroom Ceiling Plaster Intact 0.3 Negative 65 Building 1 Interior Room 3 A Door Wood Intact 0.1 Negative 66 Building 1 Interior Room 3 A Door Frame Wood DETERIORATED 0.1 Negative 67 Building 1 Interior Room 3 C Window Sill Wood Intact 0.0 Negative Double Hung 68 Building 1 Interior Room 3 C Window Sash Wood Intact 0.1 Negative Double Hung 69 Building 1 Interior Room 3 C Window Frame Wood Intact 0.1 Negative Double Hung 70 Building 1 Interior Room 3 D Window Sill Wood Intact 0.0 Negative Double Hung 71 Building 1 Interior Room 3 D Window Sash Wood Intact 0.2 Negative Double Hung 72 Building 1 Interior Room 3 D Window Frame Wood Intact 0.1 Negative Double Hung 73 Building 1 Interior Room 3 A Closet Door Frame Wood Intact 0.2 Negative 74 Building 1 Interior Room 3 A Cabinet Frame Wood Intact 0.2 Negative 75 Building 1 Interior Room 3 A Cabinet Door Wood Intact 0.2 Negative 76 Building 1 Interior Room 3 A Wall Plaster Intact 0.2 Negative 77 Building 1 Interior Room 3 B Wall Plaster Intact 0.2 Negative 78 Building 1 Interior Room 3 C Wall Plaster Intact 0.1 Negative 79 Building 1 Interior Room 3 D Wall Plaster Intact 0.1 Negative 80 Building 1 Interior Room 3 Heater Vent Metal Intact 0.0 Negative 81 Building 1 Interior Room 3 Ceiling Acoustic Intact 0.3 Negative 82 Building 1 Interior Room 4 C Door Wood Intact 0.1 Negative 83 Building 1 Interior Room 4 C Door Frame Wood Intact 0.2 Negative 84 Building 1 Interior Room 4 A Window Sill Wood Intact 0.0 Negative Double Hung 85 Building 1 Interior Room 4 A Window Sash Wood Intact 0.1 Negative Double Hung 86 Building 1 Interior Room 4 A Window Frame Wood Intact 0.3 Negative Double Hung 87 Building 1 Interior Room 4 C Closet Door Frame Wood Intact 0.1 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 3 of 28 6/22/2017 2:26:46 PM

45 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 88 Building 1 Interior Room 4 C Closet Shelf Wood Intact 0.1 Negative 89 Building 1 Interior Room 4 C Closet Shelf Support Wood Intact 0.2 Negative 90 Building 1 Interior Room 4 C Cabinet Frame Wood Intact 0.0 Negative 91 Building 1 Interior Room 4 C Cabinet Door Wood Intact 0.0 Negative 92 Building 1 Interior Room 4 A Wall Wood Intact 0.0 Negative 93 Building 1 Interior Room 4 B Wall Wood Intact 0.0 Negative 94 Building 1 Interior Room 4 C Wall Plaster Intact 0.1 Negative 95 Building 1 Interior Room 4 D Wall Wood Intact 0.1 Negative 96 Building 1 Interior Room 4 Heater Vent Metal Intact 0.0 Negative 97 Building 1 Interior Room 4 Ceiling Acoustic Intact 0.3 Negative 98 Building 1 Exterior Room 5 A Door Wood DETERIORATED 0.0 Negative 99 Building 1 Exterior Room 5 A Door Frame Wood DETERIORATED 0.4 Negative 100 Building 1 Interior Room 5 A Door Wood Intact 0.2 Negative 101 Building 1 Interior Room 5 A Door Frame Wood Intact 0.2 Negative 102 Building 1 Interior Room 5 A Window Sill Wood Intact 0.1 Negative Fixed 103 Building 1 Interior Room 5 A Window Sash Wood Intact 0.1 Negative Fixed 104 Building 1 Interior Room 5 A Window Frame Wood Intact 0.1 Negative Fixed 105 Building 1 Interior Room 5 B Window Sill Wood Intact 0.0 Negative Aluminum 106 Building 1 Interior Room 5 B Window Frame Wood Intact 0.1 Negative Aluminum 107 Building 1 Interior Room 5 D Window Sill Wood DETERIORATED 0.1 Negative Aluminum 108 Building 1 Interior Room 5 D Window Frame Wood DETERIORATED 0.1 Negative Aluminum 109 Building 1 Interior Room 5 A Wall Wood Intact 0.0 Negative 110 Building 1 Interior Room 5 B Wall Wood Intact 0.1 Negative 111 Building 1 Interior Room 5 C Wall Wood Intact 0.1 Negative 112 Building 1 Interior Room 5 D Wall Wood Intact 0.1 Negative 113 Building 1 Interior Room 5 Heater Vent Metal Intact 0.0 Negative 114 Building 1 Interior Room 5 Ceiling Acoustic Intact 0.3 Negative 2x2 Tiles 115 Building 1 Perimeter Exterior North Side A Window Well Wood Intact 0.1 Negative Fixed 116 Building 1 Perimeter Exterior North Side A Window Sash Wood Intact 0.2 Negative Fixed L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 4 of 28 6/22/2017 2:26:46 PM

46 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 117 Building 1 Perimeter Exterior North Side A Window Frame Wood Intact 0.1 Negative Fixed 118 Building 1 Perimeter Exterior North Side A Window Bars Metal DETERIORATED 0.1 Negative 119 Building 1 Perimeter Exterior North Side A Window Well Wood Intact 0.2 Negative Double Hung 120 Building 1 Perimeter Exterior North Side A Window Sash Wood Intact 0.2 Negative Double Hung 121 Building 1 Perimeter Exterior North Side A Window Frame Wood Intact 0.1 Negative Double Hung 122 Building 1 Perimeter Exterior North Side A Window Well Wood DETERIORATED 0.2 Negative Aluminum 123 Building 1 Perimeter Exterior North Side A Window Frame Wood DETERIORATED 0.4 Negative Aluminum 124 Building 1 Perimeter Exterior North Side A Window Well Wood Intact 0.3 Negative Aluminum 125 Building 1 Perimeter Exterior North Side A Window Frame Wood Intact 0.4 Negative Aluminum 126 Building 1 Perimeter Exterior North Side A Wall Stucco Intact 0.5 Negative 127 Building 1 Perimeter Exterior North Side A Wall Stucco DETERIORATED 0.5 Negative 128 Building 1 Perimeter Exterior North Side A Wall Stucco DETERIORATED 0.4 Negative 129 Building 1 Perimeter Exterior North Side A Wall Wood DETERIORATED 0.1 Negative 130 Building 1 Perimeter Exterior North Side A Eaves Wood DETERIORATED 0.2 Negative 131 Building 1 Perimeter Exterior North Side A Rafters Wood DETERIORATED 0.1 Negative 132 Building 1 Perimeter Exterior North Side A Fascia Wood DETERIORATED 0.1 Negative 133 Building 1 Perimeter Exterior North Side A Column Wood DETERIORATED 0.2 Negative 134 Building 1 Perimeter Exterior North Side A Beam Wood DETERIORATED 0.1 Negative 135 Building 1 Perimeter Exterior North Side A Ceiling Wood Intact 0.0 Negative 136 Building 1 Perimeter Exterior North Side A Gutter Metal Intact 0.0 Negative 137 Building 1 Perimeter Exterior North Side A Downspout Metal Intact 0.1 Negative 138 Building 1 Perimeter Exterior North Side A Frame Wood Intact 0.1 Negative 139 Building 1 Perimeter Exterior North Side A Horizontal Trim Wood DETERIORATED 0.1 Negative Between Stucco And Wood Siding 140 Building 1 Perimeter Exterior North Side A Parking Stripe Asphalt DETERIORATED 0.2 Negative Blue 141 Building 1 Perimeter Exterior North Side A Parking Stripe Asphalt DETERIORATED 0.2 Negative White 142 Building 1 Perimeter Exterior East Side B Window Well Wood DETERIORATED 0.1 Negative Aluminum 143 Building 1 Perimeter Exterior East Side B Window Frame Wood DETERIORATED 0.2 Negative Aluminum 144 Building 1 Perimeter Exterior East Side B Window Bars Metal Intact 0.2 Negative 145 Building 1 Perimeter Exterior East Side B Window Frame Metal Intact 0.1 Negative Aluminum L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 5 of 28 6/22/2017 2:26:46 PM

47 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 146 Building 1 Perimeter Exterior East Side B Wall Stucco Intact 0.5 Negative 147 Building 1 Perimeter Exterior East Side B Wall Stucco Intact 0.4 Negative 148 Building 1 Perimeter Exterior East Side B Eaves Wood DETERIORATED 0.2 Negative 149 Building 1 Perimeter Exterior East Side B Rafters Wood DETERIORATED 0.2 Negative 150 Building 1 Perimeter Exterior East Side B Fascia Wood DETERIORATED 0.3 Negative 151 Building 1 Perimeter Exterior East Side B Eaves Wood DETERIORATED 0.2 Negative 152 Building 1 Perimeter Exterior East Side B Rafters Wood DETERIORATED 0.1 Negative 153 Building 1 Perimeter Exterior East Side B Fascia Wood DETERIORATED 0.1 Negative 154 Building 1 Perimeter Exterior East Side B Gutter Metal Intact 0.0 Negative 155 Building 1 Perimeter Exterior East Side B Electric Utility Box Metal DETERIORATED 0.1 Negative 156 Building 1 Perimeter Exterior East Side B Frame Wood Intact 0.1 Negative For A/C 157 Building 1 Perimeter Exterior East Side B Parking Stripe Asphalt DETERIORATED 0.0 Negative 158 Building 1 Perimeter Exterior South Side C Door Wood DETERIORATED 0.3 Negative Electrical Room 159 Building 1 Perimeter Exterior South Side C Door Frame Wood DETERIORATED 0.7 POSITIVE Electrical Room 160 Building 1 Perimeter Exterior South Side C Window Well Wood DETERIORATED 0.3 Negative Aluminum 161 Building 1 Perimeter Exterior South Side C Window Frame Wood DETERIORATED 1.4 POSITIVE Aluminum 162 Building 1 Perimeter Exterior South Side C Window Well Wood DETERIORATED 0.2 Negative Plywood 163 Building 1 Perimeter Exterior South Side C Window Sash Wood DETERIORATED 0.1 Negative Plywood 164 Building 1 Perimeter Exterior South Side C Window Frame Wood DETERIORATED 0.7 POSITIVE Plywood 165 Building 1 Perimeter Exterior South Side C Window Well Wood DETERIORATED 0.1 Negative Double Hung 166 Building 1 Perimeter Exterior South Side C Window Sash Wood DETERIORATED 0.3 Negative Double Hung 167 Building 1 Perimeter Exterior South Side C Window Frame Wood DETERIORATED 0.7 POSITIVE Double Hung 168 Building 1 Perimeter Exterior South Side C Wall Stucco DETERIORATED 0.2 Negative 169 Building 1 Perimeter Exterior South Side C Wall Stucco Intact 0.2 Negative 170 Building 1 Perimeter Exterior South Side C Wall Stucco Intact 0.4 Negative 171 Building 1 Perimeter Exterior South Side C Wall Stucco Intact 0.4 Negative 172 Building 1 Perimeter Exterior South Side C Eaves Wood DETERIORATED 0.4 Negative 173 Building 1 Perimeter Exterior South Side C Rafters Wood DETERIORATED 0.3 Negative 174 Building 1 Perimeter Exterior South Side C Fascia Wood DETERIORATED 0.2 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 6 of 28 6/22/2017 2:26:46 PM

48 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 175 Building 1 Perimeter Exterior South Side C Eaves Wood DETERIORATED 0.1 Negative 176 Building 1 Perimeter Exterior South Side C Rafters Wood DETERIORATED 0.3 Negative 177 Building 1 Perimeter Exterior South Side C Fascia Wood DETERIORATED 0.3 Negative 178 Building 1 Perimeter Exterior South Side C Fire Ext. Box Metal Intact 0.0 Negative 179 Building 1 Perimeter Exterior South Side C Awning Metal Intact 0.1 Negative 180 Building 1 Perimeter Exterior South Side C Bollard Metal DETERIORATED 2.4 POSITIVE 181 Building 1 Perimeter Exterior South Side C Bollard Metal DETERIORATED 2.5 POSITIVE 182 Building 1 Perimeter Exterior South Side C Frame Wood Intact 0.1 Negative For A/C Unit 183 Building 1 Perimeter Exterior West Side D Window Well Wood DETERIORATED 0.3 Negative Double Hung 184 Building 1 Perimeter Exterior West Side D Window Sash Wood DETERIORATED 0.3 Negative Double Hung 185 Building 1 Perimeter Exterior West Side D Window Frame Wood DETERIORATED 0.7 POSITIVE Double Hung 186 Building 1 Perimeter Exterior West Side D Window Frame Wood Intact 0.3 Negative Aluminum 187 Building 1 Perimeter Exterior West Side D Wall Stucco Intact 0.5 Negative 188 Building 1 Perimeter Exterior West Side D Wall Stucco Intact 0.5 Negative 189 Building 1 Perimeter Exterior West Side D Wall Stucco Intact 0.4 Negative 190 Building 1 Perimeter Exterior West Side D Wall Stucco Intact 0.5 Negative 191 Building 1 Perimeter Exterior West Side D Eaves Wood DETERIORATED 0.2 Negative 192 Building 1 Perimeter Exterior West Side D Rafters Wood DETERIORATED 0.2 Negative 193 Building 1 Perimeter Exterior West Side D Fascia Wood DETERIORATED 0.3 Negative 194 Building 1 Perimeter Exterior West Side D Eaves Wood DETERIORATED 0.1 Negative 195 Building 1 Perimeter Exterior West Side D Rafters Wood DETERIORATED 0.3 Negative 196 Building 1 Perimeter Exterior West Side D Fascia Wood DETERIORATED 0.3 Negative 197 Building 1 Perimeter Exterior West Side D Gutter Metal Intact 0.0 Negative 198 Building 1 Perimeter Exterior West Side D Awning Metal DETERIORATED 0.0 Negative 199 Building 2 Exterior Room 1 B Door Wood DETERIORATED 0.0 Negative 200 Building 2 Exterior Room 1 B Door Frame Wood DETERIORATED 1.9 POSITIVE 201 Building 2 Interior Room 1 B Door Wood DETERIORATED 0.2 Negative 202 Building 2 Interior Room 1 B Door Frame Wood DETERIORATED 0.3 Negative 203 Building 2 Interior Room 1 A Window Frame Wood Intact 0.0 Negative Fixed L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 7 of 28 6/22/2017 2:26:46 PM

49 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 204 Building 2 Interior Room 1 B Window Sill Wood Intact 0.2 Negative Double Hung 205 Building 2 Interior Room 1 B Window Sash Wood Intact 0.2 Negative Double Hung 206 Building 2 Interior Room 1 B Window Frame Wood Intact 0.3 Negative Double Hung 207 Building 2 Interior Room 1 A Wall Gypsum Intact 0.1 Negative 208 Building 2 Interior Room 1 B Wall Gypsum Intact 0.2 Negative 209 Building 2 Interior Room 1 C Wall Gypsum Intact 0.1 Negative 210 Building 2 Interior Room 1 D Wall Gypsum Intact 0.1 Negative 211 Building 2 Interior Room 1 D Heater Vent Metal Intact 0.0 Negative 212 Building 2 Interior Room 1 Ceiling Acoustic Intact 0.3 Negative 213 Building 2 Interior Hall B Door Frame Wood DETERIORATED 0.0 Negative 214 Building 2 Interior Hall A Closet Door Metal Intact 0.0 Negative 215 Building 2 Interior Hall A Closet Door Frame Wood Intact 0.0 Negative 216 Building 2 Interior Hall A Closet Shelf Wood Intact 0.1 Negative 217 Building 2 Interior Hall A Closet Shelf Support Wood Intact 0.7 POSITIVE 218 Building 2 Interior Hall A Wall Gypsum Intact 0.1 Negative 219 Building 2 Interior Hall B Wall Gypsum Intact 0.2 Negative 220 Building 2 Interior Hall C Wall Gypsum Intact 0.0 Negative 221 Building 2 Interior Hall D Wall Gypsum Intact 0.0 Negative 222 Building 2 Interior Hall Ceiling Gypsum Intact 0.1 Negative 223 Building 2 Interior Bathroom B Door Wood Intact 0.9 POSITIVE 224 Building 2 Interior Bathroom B Door Frame Wood DETERIORATED 1.2 POSITIVE 225 Building 2 Interior Bathroom D Window Sill Wood Intact 0.1 Negative Double Hung 226 Building 2 Interior Bathroom D Window Sash Wood Intact 0.2 Negative Double Hung 227 Building 2 Interior Bathroom D Window Frame Wood Intact 0.2 Negative Double Hung 228 Building 2 Interior Bathroom D Cabinet Frame Wood Intact 0.1 Negative 229 Building 2 Interior Bathroom D Cabinet Door Wood Intact 0.2 Negative 230 Building 2 Interior Bathroom D Cabinet Shelf Wood Intact 0.2 Negative 231 Building 2 Interior Bathroom A Wall Gypsum Intact 0.0 Negative 232 Building 2 Interior Bathroom B Wall Gypsum Intact 0.0 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 8 of 28 6/22/2017 2:26:46 PM

50 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 233 Building 2 Interior Bathroom C Wall Gypsum Intact 0.1 Negative 234 Building 2 Interior Bathroom D Wall Gypsum Intact 0.0 Negative 235 Building 2 Interior Bathroom Baseboard Wood Intact 0.0 Negative 236 Building 2 Interior Bathroom Ceiling Gypsum Intact 0.1 Negative 237 Building 2 Interior Bathroom A Shelf Wood Intact 0.1 Negative 238 Building 2 Interior Bathroom A Shelf Supports Wood Intact 0.2 Negative 239 Building 2 Interior Room 2 B Door Frame Wood Intact 0.0 Negative 240 Building 2 Interior Room 2 C Closet Shelf Wood Intact 0.1 Negative 241 Building 2 Interior Room 2 C Closet Shelf Support Wood Intact 0.2 Negative 242 Building 2 Interior Room 2 A Wall Gypsum Intact 0.1 Negative 243 Building 2 Interior Room 2 B Wall Gypsum Intact 0.1 Negative 244 Building 2 Interior Room 2 C Wall Gypsum Intact 0.0 Negative 245 Building 2 Interior Room 2 D Wall Gypsum Intact 0.0 Negative 246 Building 2 Interior Room 2 Baseboard Wood Intact 0.2 Negative 247 Building 2 Interior Room 2 Ceiling Gypsum Intact 0.1 Negative 248 Building 2 Interior Room 2 Attic Access Wood Intact 0.1 Negative 249 Building 2 Interior Room 2 Shelf Wood Intact 0.0 Negative 250 Building 2 Interior Room 2 Shelf Supports Wood Intact 0.0 Negative 251 Building 2 Exterior Room 3 D Door Wood DETERIORATED 0.0 Negative 252 Building 2 Exterior Room 3 D Door Frame Wood DETERIORATED 0.2 Negative 253 Building 2 Interior Room 3 D Door Wood Intact 0.1 Negative 254 Building 2 Interior Room 3 D Door Frame Wood Intact 0.2 Negative 255 Building 2 Interior Room 3 B Window Sill Wood Intact 0.2 Negative Double Hung 256 Building 2 Interior Room 3 B Window Sash Wood Intact 0.1 Negative Double Hung 257 Building 2 Interior Room 3 B Window Frame Wood Intact 0.3 Negative Double Hung 258 Building 2 Interior Room 3 C Window Sill Wood Intact 0.5 Negative Fixed 259 Building 2 Interior Room 3 C Window Frame Wood Intact 0.5 Negative Fixed 260 Building 2 Interior Room 3 C Window Sill Wood DETERIORATED 1.0 POSITIVE Casement 261 Building 2 Interior Room 3 C Window Sash Wood DETERIORATED 0.5 Negative Casement L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 9 of 28 6/22/2017 2:26:46 PM

51 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 262 Building 2 Interior Room 3 C Window Frame Wood DETERIORATED 0.5 Negative Casement 263 Building 2 Interior Room 3 D Window Sill Wood Intact 1.0 POSITIVE Casement 264 Building 2 Interior Room 3 D Window Sash Wood Intact 0.9 POSITIVE Casement 265 Building 2 Interior Room 3 D Window Frame Wood Intact 0.9 POSITIVE Casement 266 Building 2 Interior Room 3 A Wall Wood Intact 0.9 POSITIVE White 267 Building 2 Interior Room 3 B Wall Gypsum Intact 0.1 Negative 268 Building 2 Interior Room 3 C Wall Wood Intact 0.0 Negative 269 Building 2 Interior Room 3 D Wall Wood Intact 0.1 Negative 270 Building 2 Interior Room 3 A Wall Wood Intact 0.0 Negative Brown 271 Building 2 Interior Room 3 B Wall Wood Intact 0.0 Negative 272 Building 2 Interior Room 3 D Wall Wood Intact 0.0 Negative 273 Building 2 Interior Room 3 Baseboard Wood Intact 0.0 Negative 274 Building 2 Interior Room 3 Ceiling Wood Intact 0.2 Negative 275 Building 2 Interior Room 3 Ceiling Gypsum Intact 0.0 Negative 276 Building 2 Interior Room 4 C Door Wood Intact 0.0 Negative 277 Building 2 Interior Room 4 C Door Frame Wood DETERIORATED 0.4 Negative 278 Building 2 Interior Room 4 D Window Sill Wood DETERIORATED 0.3 Negative Double Hung 279 Building 2 Interior Room 4 D Window Sash Wood Intact 0.3 Negative Double Hung 280 Building 2 Interior Room 4 D Window Frame Wood DETERIORATED 0.1 Negative Double Hung 281 Building 2 Interior Room 4 A Wall Gypsum Intact 0.2 Negative 282 Building 2 Interior Room 4 B Wall Gypsum Intact 0.0 Negative 283 Building 2 Interior Room 4 C Wall Gypsum Intact 0.0 Negative 284 Building 2 Interior Room 4 D Wall Gypsum Intact 0.1 Negative 285 Building 2 Interior Room 4 Baseboard Wood Intact 0.2 Negative 286 Building 2 Interior Room 4 Ceiling Acoustic Intact 0.3 Negative 287 Building 2 Perimeter Exterior North Side A Window Well Wood DETERIORATED 0.0 Negative No Window 288 Building 2 Perimeter Exterior North Side A Wall Stucco DETERIORATED 0.4 Negative 289 Building 2 Perimeter Exterior North Side A Wall Stucco DETERIORATED 0.5 Negative 290 Building 2 Perimeter Exterior North Side A Wall Stucco Intact 0.5 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 10 of 28 6/22/2017 2:26:46 PM

52 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 291 Building 2 Perimeter Exterior North Side A Wall Stucco Intact 0.4 Negative 292 Building 2 Perimeter Exterior North Side A Eaves Wood DETERIORATED 3.2 POSITIVE 293 Building 2 Perimeter Exterior North Side A Fascia Wood DETERIORATED 0.7 POSITIVE 294 Building 2 Perimeter Exterior North Side A Corner Board Wood DETERIORATED 2.5 POSITIVE 295 Building 2 Perimeter Exterior East Side B Window Well Wood DETERIORATED 1.3 POSITIVE Double Hung 296 Building 2 Perimeter Exterior East Side B Window Sash Wood DETERIORATED 1.3 POSITIVE Double Hung 297 Building 2 Perimeter Exterior East Side B Window Frame Wood DETERIORATED 1.1 POSITIVE Double Hung 298 Building 2 Perimeter Exterior East Side B Window Bars Metal Intact 0.0 Negative 299 Building 2 Perimeter Exterior East Side B Window Well Wood DETERIORATED 1.0 POSITIVE Double Hung 300 Building 2 Perimeter Exterior East Side B Window Sash Wood DETERIORATED 1.5 POSITIVE Double Hung 301 Building 2 Perimeter Exterior East Side B Window Frame Wood DETERIORATED 1.2 POSITIVE Double Hung 302 Building 2 Perimeter Exterior East Side B Wall Stucco Intact 0.5 Negative 303 Building 2 Perimeter Exterior East Side B Wall Stucco Intact 0.5 Negative 304 Building 2 Perimeter Exterior East Side B Eaves Wood DETERIORATED 1.0 POSITIVE 305 Building 2 Perimeter Exterior East Side B Rafters Wood DETERIORATED 1.3 POSITIVE 306 Building 2 Perimeter Exterior East Side B Eaves Wood DETERIORATED 1.5 POSITIVE 307 Building 2 Perimeter Exterior East Side B Fascia Wood DETERIORATED 1.0 POSITIVE 308 Building 2 Perimeter Exterior East Side B Beam Wood DETERIORATED 4.1 POSITIVE Side Porch 309 Building 2 Perimeter Exterior East Side B Ceiling Stucco Intact 0.5 Negative Side Porch 310 Building 2 Perimeter Exterior East Side B Electric Utility Box Metal Intact 0.0 Negative 311 Building 2 Perimeter Exterior East Side B Corner Board Wood DETERIORATED 0.1 Negative 312 Building 2 Perimeter Exterior East Side B Parking Stripe Asphalt DETERIORATED 0.3 Negative 313 Building 2 Perimeter Exterior South Side C Window Well Wood DETERIORATED 0.3 Negative Casement 314 Building 2 Perimeter Exterior South Side C Window Sash Wood DETERIORATED 0.3 Negative Casement 315 Building 2 Perimeter Exterior South Side C Window Frame Wood DETERIORATED 0.4 Negative Casement 316 Building 2 Perimeter Exterior South Side C Window Bars Metal DETERIORATED 0.1 Negative 317 Building 2 Perimeter Exterior South Side C Window Well Wood DETERIORATED 0.1 Negative No Window 318 Building 2 Perimeter Exterior South Side C Window Frame Wood DETERIORATED 0.9 POSITIVE No Window 319 Building 2 Perimeter Exterior South Side C Trim Wood DETERIORATED 0.1 Negative Plywood L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 11 of 28 6/22/2017 2:26:46 PM

53 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 320 Building 2 Perimeter Exterior South Side C Wall Stucco Intact 0.2 Negative 321 Building 2 Perimeter Exterior South Side C Wall Stucco Intact 0.2 Negative 322 Building 2 Perimeter Exterior South Side C Wall Stucco Intact 0.4 Negative 323 Building 2 Perimeter Exterior South Side C Wall Stucco Intact 0.4 Negative 324 Building 2 Perimeter Exterior South Side C Eaves Wood DETERIORATED 1.6 POSITIVE 325 Building 2 Perimeter Exterior South Side C Rafters Wood DETERIORATED 1.2 POSITIVE 326 Building 2 Perimeter Exterior South Side C Fascia Wood DETERIORATED 1.0 POSITIVE 327 Building 2 Perimeter Exterior South Side C Eaves Wood DETERIORATED 1.2 POSITIVE 328 Building 2 Perimeter Exterior South Side C Fascia Wood DETERIORATED 1.3 POSITIVE 329 Building 2 Perimeter Exterior South Side C Vent Metal Intact 0.2 Negative 330 Building 2 Perimeter Exterior South Side C Corner Board Wood DETERIORATED 0.3 Negative 331 Building 2 Perimeter Exterior West Side D Window Well Wood DETERIORATED 0.3 Negative No Window 332 Building 2 Perimeter Exterior West Side D Window Frame Wood DETERIORATED 2.9 POSITIVE No Window 333 Building 2 Perimeter Exterior West Side D Trim Wood DETERIORATED 0.1 Negative Plywood 334 Building 2 Perimeter Exterior West Side D Window Well Wood DETERIORATED 4.7 POSITIVE Double Hung 335 Building 2 Perimeter Exterior West Side D Window Sash Wood DETERIORATED 0.1 Negative Double Hung 336 Building 2 Perimeter Exterior West Side D Window Frame Wood Intact 0.7 POSITIVE Double Hung 337 Building 2 Perimeter Exterior West Side D Window Bars Metal Intact 0.0 Negative 338 Building 2 Perimeter Exterior West Side D Wall Stucco Intact 0.3 Negative 339 Building 2 Perimeter Exterior West Side D Wall Stucco Intact 0.5 Negative 340 Building 2 Perimeter Exterior West Side D Wall Stucco Intact 0.5 Negative 341 Building 2 Perimeter Exterior West Side D Wall Stucco Intact 0.3 Negative 342 Building 2 Perimeter Exterior West Side D Eaves Wood DETERIORATED 1.6 POSITIVE 343 Building 2 Perimeter Exterior West Side D Rafters Wood DETERIORATED 1.5 POSITIVE 344 Building 2 Perimeter Exterior West Side D Eaves Wood DETERIORATED 1.2 POSITIVE 345 Building 2 Perimeter Exterior West Side D Fascia Wood DETERIORATED 0.5 Negative 346 Building 2 Perimeter Exterior West Side D Gutter Vinyl Intact 0.0 Negative 347 Building 2 Perimeter Exterior West Side D Electric Utility Box Metal DETERIORATED 0.0 Negative 348 Building 2 Perimeter Exterior West Side D Corner Board Wood DETERIORATED 9.9 POSITIVE L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 12 of 28 6/22/2017 2:26:46 PM

54 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 349 Building 2 Perimeter Exterior West Side D Post Wood Intact 0.0 Negative 350 Building 2 Perimeter Exterior West Side D Pipe Metal Intact 0.0 Negative 351 Building 3 Exterior Room 1 A Door Wood DETERIORATED 0.2 Negative 352 Building 3 Exterior Room 1 A Door Frame Wood DETERIORATED 0.1 Negative 353 Building 3 Interior Room 1 A Door Wood Intact 0.1 Negative 354 Building 3 Interior Room 1 A Door Frame Wood Intact 0.1 Negative 355 Building 3 Interior Room 1 A Window Sill Gypsum Intact 0.1 Negative Fixed 356 Building 3 Interior Room 1 B Window Sill Gypsum Intact 0.1 Negative Aluminum 357 Building 3 Interior Room 1 A Wall Gypsum Intact 0.0 Negative 358 Building 3 Interior Room 1 B Wall Gypsum Intact 0.0 Negative 359 Building 3 Interior Room 1 C Wall Gypsum Intact 0.1 Negative 360 Building 3 Interior Room 1 D Wall Gypsum Intact 0.0 Negative 361 Building 3 Interior Room 1 Ceiling Gypsum Intact 0.1 Negative 362 Building 3 Interior Room 1 B Heater Vent Metal Intact 0.0 Negative 363 Building 3 Interior Room 1 C Crown Molding Wood Intact 0.0 Negative 364 Building 3 Exterior Room 2 B Door Wood DETERIORATED 0.3 Negative 365 Building 3 Exterior Room 2 B Door Frame Wood DETERIORATED 3.5 POSITIVE 366 Building 3 Interior Room 2 B Door Wood Intact 0.0 Negative 367 Building 3 Interior Room 2 B Door Frame Wood DETERIORATED 3.6 POSITIVE 368 Building 3 Exterior Room 2 B Door Metal Intact 0.0 Negative 369 Building 3 Exterior Room 2 B Door Frame Wood Intact 0.1 Negative 370 Building 3 Interior Room 2 B Door Metal Intact 0.0 Negative 371 Building 3 Interior Room 2 B Door Frame Wood Intact 0.2 Negative 372 Building 3 Interior Room 2 A Window Sash Wood DETERIORATED 0.1 Negative Casement 373 Building 3 Interior Room 2 A Window Frame Wood DETERIORATED 0.2 Negative Casement 374 Building 3 Interior Room 2 B Window Sill Wood Intact 0.1 Negative Fixed 375 Building 3 Interior Room 2 C Window Frame Wood Intact 0.1 Negative Fixed 376 Building 3 Interior Room 2 D Cabinet Frame Wood Intact 0.0 Negative 377 Building 3 Interior Room 2 D Cabinet Shelf Wood Intact 0.1 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 13 of 28 6/22/2017 2:26:46 PM

55 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 378 Building 3 Interior Room 2 A Wall Wood Intact 0.0 Negative 379 Building 3 Interior Room 2 B Wall Wood Intact 0.0 Negative 380 Building 3 Interior Room 2 C Wall Gypsum Intact 0.1 Negative 381 Building 3 Interior Room 2 D Wall Gypsum Intact 0.0 Negative 382 Building 3 Interior Room 2 Baseboard Wood Intact 0.1 Negative 383 Building 3 Interior Room 2 B Heater Vent Metal Intact 0.0 Negative 384 Building 3 Interior Room 2 Ceiling Acoustic Intact 0.3 Negative 385 Building 3 Interior Room 2 Attic Access Wood Intact 0.0 Negative 386 Building 3 Interior Room 2 Attic Access Frame Wood Intact 0.1 Negative 387 Building 3 Interior Hall A Door Wood Intact 0.0 Negative 388 Building 3 Interior Hall A Door Frame Wood Intact 0.1 Negative 389 Building 3 Interior Hall B Cabinet Shelf Wood Intact 0.0 Negative 390 Building 3 Interior Hall B Counter Top Wood Intact 0.1 Negative 391 Building 3 Interior Hall A Wall Gypsum Intact 0.1 Negative 392 Building 3 Interior Hall B Wall Gypsum Intact 0.0 Negative 393 Building 3 Interior Hall C Wall Gypsum Intact 0.0 Negative 394 Building 3 Interior Hall D Wall Gypsum Intact 0.1 Negative 395 Building 3 Interior Hall Ceiling Gypsum Intact 0.1 Negative 396 Building 3 Interior Hall Crown Molding Wood Intact 0.2 Negative 397 Building 3 Interior Bathroom 1 A Door Wood Intact 0.0 Negative 398 Building 3 Interior Bathroom 1 A Door Frame Wood Intact 0.2 Negative 399 Building 3 Interior Bathroom 1 C Window Sill Wood Intact 0.2 Negative Double Hung 400 Building 3 Interior Bathroom 1 C Window Sash Wood Intact 2.4 POSITIVE Double Hung 401 Building 3 Interior Bathroom 1 C Window Frame Wood Intact 0.1 Negative Double Hung 402 Building 3 Interior Bathroom 1 C Cabinet Frame Wood Intact 0.1 Negative 403 Building 3 Interior Bathroom 1 C Cabinet Door Wood Intact 0.1 Negative 404 Building 3 Interior Bathroom 1 C Cabinet Shelf Wood Intact 0.2 Negative 405 Building 3 Interior Bathroom 1 A Wall Gypsum Intact 0.0 Negative 406 Building 3 Interior Bathroom 1 B Wall Wood Intact 0.0 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 14 of 28 6/22/2017 2:26:46 PM

56 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 407 Building 3 Interior Bathroom 1 C Wall Wood Intact 0.1 Negative 408 Building 3 Interior Bathroom 1 D Wall Gypsum Intact 0.1 Negative 409 Building 3 Interior Bathroom 1 Baseboard Wood Intact 0.0 Negative 410 Building 3 Interior Bathroom 1 Ceiling Gypsum Intact 0.1 Negative 411 Building 3 Interior Bathroom 1 Floor Tile Intact 0.0 Negative 412 Building 3 Exterior Room 3 D Door Wood Intact 0.0 Negative 413 Building 3 Exterior Room 3 D Door Frame Wood DETERIORATED 0.1 Negative 414 Building 3 Interior Room 3 D Door Wood Intact 0.0 Negative 415 Building 3 Interior Room 3 D Door Frame Wood Intact 0.0 Negative 416 Building 3 Interior Room 3 B Door Wood Intact 0.1 Negative 417 Building 3 Interior Room 3 B Door Frame Wood Intact 0.1 Negative 418 Building 3 Interior Room 3 A Window Sill Wood Intact 0.0 Negative Aluminum 419 Building 3 Interior Room 3 A Window Frame Wood Intact 0.1 Negative Aluminum 420 Building 3 Interior Room 3 A Wall Wood Intact 0.1 Negative 421 Building 3 Interior Room 3 B Wall Wood Intact 0.0 Negative 422 Building 3 Interior Room 3 C Wall Wood Intact 0.1 Negative 423 Building 3 Interior Room 3 D Wall Wood Intact 0.0 Negative 424 Building 3 Interior Room 3 C Wall Gypsum Intact 0.0 Negative 425 Building 3 Interior Room 3 Baseboard Wood Intact 0.2 Negative 426 Building 3 Interior Room 3 D Heater Vent Metal Intact 0.0 Negative 427 Building 3 Interior Room 3 Ceiling Acoustic Intact 0.2 Negative 428 Building 3 Interior Bathroom 2 B Door Wood Intact 0.0 Negative 429 Building 3 Interior Bathroom 2 B Door Frame Wood Intact 0.1 Negative 430 Building 3 Interior Bathroom 2 A Window Sill Wood Intact 0.1 Negative Double Hung 431 Building 3 Interior Bathroom 2 A Window Sash Wood Intact 0.3 Negative Double Hung 432 Building 3 Interior Bathroom 2 A Window Frame Wood Intact 0.1 Negative Double Hung 433 Building 3 Interior Bathroom 2 A Wall Gypsum Intact 0.1 Negative 434 Building 3 Interior Bathroom 2 B Wall Gypsum Intact 0.2 Negative 435 Building 3 Interior Bathroom 2 C Wall Gypsum Intact 0.1 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 15 of 28 6/22/2017 2:26:46 PM

57 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 436 Building 3 Interior Bathroom 2 D Wall Gypsum DETERIORATED 0.1 Negative 437 Building 3 Interior Bathroom 2 C Wall Wood Intact 0.2 Negative 438 Building 3 Interior Bathroom 2 Baseboard Wood Intact 0.2 Negative 439 Building 3 Interior Bathroom 2 Ceiling Gypsum Intact 0.1 Negative 440 Building 3 Interior Bathroom 2 Floor Tile Intact 0.1 Negative Shower 441 Building 3 Interior Bathroom 2 Floor Concrete DETERIORATED 0.0 Negative Shower 442 Building 3 Exterior Room 4 C Door Wood DETERIORATED 0.0 Negative 443 Building 3 Exterior Room 4 C Door Frame Wood DETERIORATED 0.0 Negative 444 Building 3 Interior Room 4 C Door Wood Intact 0.1 Negative 445 Building 3 Interior Room 4 C Door Frame Wood Intact 0.2 Negative 446 Building 3 Interior Room 4 C Window Sill Gypsum Intact 0.1 Negative Aluminum 447 Building 3 Interior Room 4 D Window Sill Gypsum Intact 0.0 Negative Aluminum 448 Building 3 Interior Room 4 A Wall Gypsum Intact 0.1 Negative 449 Building 3 Interior Room 4 B Wall Gypsum Intact 0.2 Negative 450 Building 3 Interior Room 4 C Wall Gypsum Intact 0.2 Negative 451 Building 3 Interior Room 4 D Wall Gypsum Intact 0.0 Negative 452 Building 3 Interior Room 4 Ceiling Acoustic Intact 0.2 Negative 453 Building 3 Interior Room 4 Beam Wood Intact 0.0 Negative 454 Building 3 Interior Room 4 Crown Molding Wood Intact 0.0 Negative 455 Building 3 Interior Room 4 C Frame Wood Intact 0.1 Negative For A/C Unit 456 Building 3 Perimeter Exterior North Side A Window Well Wood DETERIORATED 2.8 POSITIVE Aluminum 457 Building 3 Perimeter Exterior North Side A Window Frame Wood DETERIORATED 1.6 POSITIVE Aluminum 458 Building 3 Perimeter Exterior North Side A Window Bars Metal DETERIORATED 0.1 Negative 459 Building 3 Perimeter Exterior North Side A Wall Wood DETERIORATED 0.7 POSITIVE 460 Building 3 Perimeter Exterior North Side A Wall Wood DETERIORATED 0.7 POSITIVE 461 Building 3 Perimeter Exterior North Side A Wall Stucco Intact 0.4 Negative 462 Building 3 Perimeter Exterior North Side A Wall Stucco Intact 0.5 Negative 463 Building 3 Perimeter Exterior North Side A Eaves Wood DETERIORATED 0.3 Negative Newer 464 Building 3 Perimeter Exterior North Side A Rafters Wood DETERIORATED 1.3 POSITIVE L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 16 of 28 6/22/2017 2:26:46 PM

58 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 465 Building 3 Perimeter Exterior North Side A Eaves Wood DETERIORATED 1.3 POSITIVE 466 Building 3 Perimeter Exterior North Side A Rafters Wood DETERIORATED 1.2 POSITIVE 467 Building 3 Perimeter Exterior North Side A Fascia Wood DETERIORATED 0.9 POSITIVE 468 Building 3 Perimeter Exterior North Side A Eaves Wood DETERIORATED 2.1 POSITIVE 469 Building 3 Perimeter Exterior North Side A Fascia Wood DETERIORATED 1.3 POSITIVE 470 Building 3 Perimeter Exterior North Side A Gutter Metal DETERIORATED 0.1 Negative 471 Building 3 Perimeter Exterior North Side A Electric Utility Box Metal Intact 0.2 Negative 472 Building 3 Perimeter Exterior North Side A Vent Wood DETERIORATED 0.7 POSITIVE Upper 473 Building 3 Perimeter Exterior North Side A Corner Board Wood DETERIORATED 0.7 POSITIVE 474 Building 3 Perimeter Exterior North Side A Post Metal Intact 0.0 Negative 475 Building 3 Perimeter Exterior East Side B Window Well Wood DETERIORATED 2.0 POSITIVE Boarded Up 476 Building 3 Perimeter Exterior East Side B Window Frame Wood DETERIORATED 1.3 POSITIVE Boarded Up 477 Building 3 Perimeter Exterior East Side B Wall Wood DETERIORATED 1.0 POSITIVE 478 Building 3 Perimeter Exterior East Side B Wall Wood DETERIORATED 1.0 POSITIVE 479 Building 3 Perimeter Exterior East Side B Wall Wood DETERIORATED 1.2 POSITIVE 480 Building 3 Perimeter Exterior East Side B Wall Wood DETERIORATED 1.0 POSITIVE 481 Building 3 Perimeter Exterior East Side B Eaves Wood DETERIORATED 0.9 POSITIVE 482 Building 3 Perimeter Exterior East Side B Fascia Wood DETERIORATED 0.9 POSITIVE 483 Building 3 Perimeter Exterior East Side B Column Wood DETERIORATED 0.9 POSITIVE Patio 484 Building 3 Perimeter Exterior East Side B Beam Wood DETERIORATED 2.0 POSITIVE Patio 485 Building 3 Perimeter Exterior East Side B Ceiling Wood DETERIORATED 0.9 POSITIVE Patio 486 Building 3 Perimeter Exterior East Side B Corner Board Wood DETERIORATED 0.1 Negative 487 Building 3 Perimeter Exterior South Side C Window Well Wood DETERIORATED 1.3 POSITIVE Aluminum 488 Building 3 Perimeter Exterior South Side C Window Frame Wood DETERIORATED 1.4 POSITIVE Aluminum 489 Building 3 Perimeter Exterior South Side C Window Bars Metal Intact 0.0 Negative 490 Building 3 Perimeter Exterior South Side C Window Well Wood DETERIORATED 0.4 Negative No Window 491 Building 3 Perimeter Exterior South Side C Window Frame Wood DETERIORATED 0.2 Negative No Window 492 Building 3 Perimeter Exterior South Side C Trim Wood DETERIORATED 0.1 Negative Plywood 493 Building 3 Perimeter Exterior South Side C Window Well Wood DETERIORATED 0.5 Negative Double Hung L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 17 of 28 6/22/2017 2:26:46 PM

59 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 494 Building 3 Perimeter Exterior South Side C Window Sash Wood DETERIORATED 0.7 POSITIVE Double Hung 495 Building 3 Perimeter Exterior South Side C Window Frame Wood DETERIORATED 0.5 Negative Double Hung 496 Building 3 Perimeter Exterior South Side C Window Well Wood DETERIORATED 0.3 Negative Boarded Up 497 Building 3 Perimeter Exterior South Side C Window Frame Wood DETERIORATED 0.3 Negative Boarded Up 498 Building 3 Perimeter Exterior South Side C Wall Wood DETERIORATED 1.6 POSITIVE 499 Building 3 Perimeter Exterior South Side C Wall Wood DETERIORATED 1.5 POSITIVE 500 Building 3 Perimeter Exterior South Side C Wall Wood DETERIORATED 1.5 POSITIVE 501 Building 3 Perimeter Exterior South Side C Wall Wood DETERIORATED 1.4 POSITIVE 502 Building 3 Perimeter Exterior South Side C Eaves Wood DETERIORATED 1.2 POSITIVE 503 Building 3 Perimeter Exterior South Side C Fascia Wood DETERIORATED 1.0 POSITIVE 504 Building 3 Perimeter Exterior South Side C Eaves Wood DETERIORATED 1.4 POSITIVE 505 Building 3 Perimeter Exterior South Side C Rafters Wood DETERIORATED 1.4 POSITIVE 506 Building 3 Perimeter Exterior South Side C Fascia Wood DETERIORATED 0.7 POSITIVE 507 Building 3 Perimeter Exterior South Side C Vent Wood DETERIORATED 1.0 POSITIVE Upper 508 Building 3 Perimeter Exterior South Side C Pipe Metal DETERIORATED 0.0 Negative 509 Building 3 Perimeter Exterior South Side C Frame Wood Intact 0.1 Negative For A/C Unit 510 Building 3 Perimeter Exterior South Side C Corner Board Wood DETERIORATED 0.0 Negative 511 Building 3 Perimeter Exterior West Side D Window Well Wood DETERIORATED 0.3 Negative Aluminum 512 Building 3 Perimeter Exterior West Side D Window Frame Wood DETERIORATED 2.3 POSITIVE Aluminum 513 Building 3 Perimeter Exterior West Side D Window Bars Metal Intact 0.1 Negative 514 Building 3 Perimeter Exterior West Side D Wall Wood DETERIORATED 1.2 POSITIVE 515 Building 3 Perimeter Exterior West Side D Wall Wood DETERIORATED 1.2 POSITIVE 516 Building 3 Perimeter Exterior West Side D Wall Wood DETERIORATED 1.3 POSITIVE 517 Building 3 Perimeter Exterior West Side D Wall Wood DETERIORATED 1.4 POSITIVE 518 Building 3 Perimeter Exterior West Side D Eaves Wood DETERIORATED 1.2 POSITIVE 519 Building 3 Perimeter Exterior West Side D Rafters Wood DETERIORATED 1.3 POSITIVE 520 Building 3 Perimeter Exterior West Side D Fascia Wood DETERIORATED 0.9 POSITIVE 521 Building 3 Perimeter Exterior West Side D Column Wood DETERIORATED 0.0 Negative Porch 522 Building 3 Perimeter Exterior West Side D Beam Wood DETERIORATED 0.7 POSITIVE Porch L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 18 of 28 6/22/2017 2:26:46 PM

60 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 523 Building 3 Perimeter Exterior West Side D Ceiling Wood DETERIORATED 0.7 POSITIVE Porch 524 Building 3 Perimeter Exterior West Side D Corner Board Wood DETERIORATED 1.4 POSITIVE 525 Building 3 Perimeter Exterior West Side D Lattice Wood DETERIORATED 0.1 Negative 526 Building 3 Perimeter Exterior Shed B Door Metal Intact 0.0 Negative 527 Building 3 Perimeter Exterior Shed B Door Frame Metal Intact 0.1 Negative 528 Building 3 Perimeter Exterior Shed A Wall Metal Intact 0.0 Negative 529 Building 3 Perimeter Exterior Shed B Wall Metal Intact 0.0 Negative 530 Building 3 Perimeter Exterior Shed C Wall Metal Intact 0.1 Negative 531 Building 3 Perimeter Exterior Shed D Wall Metal Intact 0.1 Negative 532 Building 3 Perimeter Exterior Shed Roof Trim Metal Intact 0.0 Negative 533 Building 4 Exterior Room 1 A Door Wood DETERIORATED 0.3 Negative 534 Building 4 Exterior Room 1 A Door Frame Wood DETERIORATED 1.2 POSITIVE 535 Building 4 Interior Room 1 A Door Wood Intact 0.3 Negative 536 Building 4 Interior Room 1 A Door Frame Wood DETERIORATED 0.4 Negative 537 Building 4 Interior Room 1 B Window Sill Wood DETERIORATED 0.0 Negative Fixed 538 Building 4 Interior Room 1 B Window Sash Wood Intact 0.2 Negative Fixed 539 Building 4 Interior Room 1 B Window Frame Wood DETERIORATED 0.1 Negative Fixed 540 Building 4 Interior Room 1 D Window Sill Wood Intact 0.0 Negative No Window 541 Building 4 Interior Room 1 D Window Frame Wood Intact 0.1 Negative No Window 542 Building 4 Interior Room 1 A Wall Gypsum Intact 0.1 Negative 543 Building 4 Interior Room 1 B Wall Gypsum Intact 0.2 Negative 544 Building 4 Interior Room 1 C Wall Gypsum Intact 0.1 Negative 545 Building 4 Interior Room 1 D Wall Gypsum Intact 0.1 Negative 546 Building 4 Interior Room 1 Ceiling Gypsum Intact 0.1 Negative 547 Building 4 Exterior Room 2 C Door Wood Intact 0.1 Negative 548 Building 4 Exterior Room 2 C Door Frame Wood DETERIORATED 1.1 POSITIVE 549 Building 4 Interior Room 2 C Door Wood Intact 0.0 Negative 550 Building 4 Interior Room 2 C Door Frame Wood Intact 0.3 Negative 551 Building 4 Interior Room 2 B Window Sill Wood Intact 0.1 Negative No Window L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 19 of 28 6/22/2017 2:26:46 PM

61 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 552 Building 4 Interior Room 2 B Window Frame Wood Intact 0.1 Negative No Window 553 Building 4 Interior Room 2 D Window Sill Wood Intact 0.3 Negative Double Hung 554 Building 4 Interior Room 2 D Window Sash Wood Intact 0.2 Negative Double Hung 555 Building 4 Interior Room 2 D Window Frame Wood Intact 0.3 Negative Double Hung 556 Building 4 Interior Room 2 A Wall Gypsum Intact 0.0 Negative 557 Building 4 Interior Room 2 B Wall Gypsum Intact 0.0 Negative 558 Building 4 Interior Room 2 C Wall Gypsum Intact 0.1 Negative 559 Building 4 Interior Room 2 D Wall Gypsum Intact 0.1 Negative 560 Building 4 Interior Room 2 Ceiling Gypsum Intact 0.1 Negative 561 Building 4 Interior Hall A Door Frame Wood DETERIORATED 0.1 Negative 562 Building 4 Interior Hall B Window Sash Wood Intact 0.3 Negative Casement 563 Building 4 Interior Hall B Window Frame Wood Intact 0.3 Negative Casement 564 Building 4 Interior Hall A Wall Wood Intact 0.1 Negative 565 Building 4 Interior Hall B Wall Wood Intact 0.2 Negative 566 Building 4 Interior Hall C Wall Wood Intact 0.0 Negative 567 Building 4 Interior Hall D Wall Wood Intact 0.0 Negative 568 Building 4 Interior Hall Ceiling Gypsum Intact 0.1 Negative 569 Building 4 Interior Hall Floor Tile Intact 0.0 Negative 570 Building 4 Interior Hall Attic Access Gypsum Intact 0.0 Negative 571 Building 4 Interior Hall Attic Access Frame Wood Intact 0.0 Negative 572 Building 4 Interior Bathroom 1 B Door Wood Intact 0.0 Negative 573 Building 4 Interior Bathroom 1 B Door Frame Wood Intact 0.1 Negative 574 Building 4 Interior Bathroom 1 D Window Sill Wood Intact 0.1 Negative Double Hung 575 Building 4 Interior Bathroom 1 D Window Sash Wood Intact 0.3 Negative Double Hung 576 Building 4 Interior Bathroom 1 D Window Frame Wood Intact 0.3 Negative Double Hung 577 Building 4 Interior Bathroom 1 C Cabinet Frame Wood Intact 0.0 Negative 578 Building 4 Interior Bathroom 1 C Cabinet Door Wood Intact 0.0 Negative 579 Building 4 Interior Bathroom 1 C Cabinet Shelf Wood Intact 0.0 Negative 580 Building 4 Interior Bathroom 1 A Wall Wood Intact 0.1 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 20 of 28 6/22/2017 2:26:46 PM

62 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 581 Building 4 Interior Bathroom 1 B Wall Wood Intact 0.1 Negative 582 Building 4 Interior Bathroom 1 C Wall Wood Intact 0.2 Negative 583 Building 4 Interior Bathroom 1 D Wall Wood Intact 0.2 Negative 584 Building 4 Interior Bathroom 1 Ceiling Gypsum Intact 0.1 Negative 585 Building 4 Interior Bathroom 1 Floor Tile Intact 0.0 Negative 586 Building 4 Exterior Room 3 C Door Metal Intact 0.0 Negative 587 Building 4 Exterior Room 3 C Door Frame Wood Intact 0.0 Negative 588 Building 4 Interior Room 3 C Door Metal Intact 0.0 Negative 589 Building 4 Interior Room 3 C Door Frame Wood Intact 0.1 Negative 590 Building 4 Interior Room 3 B Window Sill Wood Intact 0.2 Negative Fixed 591 Building 4 Interior Room 3 B Window Sash Wood Intact 0.0 Negative Fixed 592 Building 4 Interior Room 3 B Window Frame Wood Intact 0.0 Negative Fixed 593 Building 4 Interior Room 3 C Window Sill Wood Intact 0.2 Negative Fixed 594 Building 4 Interior Room 3 C Window Sash Wood Intact 0.0 Negative Fixed 595 Building 4 Interior Room 3 C Window Frame Wood Intact 0.1 Negative Fixed 596 Building 4 Interior Room 3 A Wall Gypsum Intact 0.1 Negative 597 Building 4 Interior Room 3 B Wall Gypsum Intact 0.2 Negative 598 Building 4 Interior Room 3 C Wall Gypsum Intact 0.0 Negative 599 Building 4 Interior Room 3 D Wall Gypsum Intact 0.0 Negative 600 Building 4 Interior Room 3 D Wall Wood Intact 0.0 Negative 601 Building 4 Interior Room 3 Ceiling Gypsum Intact 0.1 Negative 602 Building 4 Interior Room 3 Horizontal Trim Wood Intact 0.1 Negative 603 Building 4 Exterior Room 4 C Door Metal Intact 0.1 Negative 604 Building 4 Exterior Room 4 C Door Frame Wood Intact 0.0 Negative 605 Building 4 Interior Room 4 C Door Metal Intact 0.0 Negative 606 Building 4 Interior Room 4 C Door Frame Wood Intact 0.0 Negative 607 Building 4 Interior Room 4 B Door Wood Intact 0.0 Negative 608 Building 4 Interior Room 4 B Door Frame Wood DETERIORATED 0.1 Negative 609 Building 4 Interior Room 4 C Window Sill Wood DETERIORATED 0.0 Negative Aluminum L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 21 of 28 6/22/2017 2:26:46 PM

63 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 610 Building 4 Interior Room 4 C Window Frame Wood Intact 0.1 Negative Aluminum 611 Building 4 Interior Room 4 A Window Sill Wood DETERIORATED 0.2 Negative Double Hung 612 Building 4 Interior Room 4 A Window Sash Wood Intact 0.0 Negative Double Hung 613 Building 4 Interior Room 4 A Window Frame Wood DETERIORATED 0.1 Negative Double Hung 614 Building 4 Interior Room 4 A Wall Gypsum Intact 0.1 Negative 615 Building 4 Interior Room 4 B Wall Gypsum Intact 0.1 Negative 616 Building 4 Interior Room 4 C Wall Gypsum Intact 0.2 Negative 617 Building 4 Interior Room 4 D Wall Gypsum Intact 0.0 Negative 618 Building 4 Interior Room 4 Ceiling Gypsum Intact 0.1 Negative 619 Building 4 Exterior Room 5 C Door Wood DETERIORATED 0.2 Negative 620 Building 4 Exterior Room 5 C Door Frame Wood DETERIORATED 0.3 Negative 621 Building 4 Interior Room 5 C Door Wood DETERIORATED 0.1 Negative 622 Building 4 Interior Room 5 C Door Frame Wood DETERIORATED 0.1 Negative 623 Building 4 Exterior Room 5 D Door Wood DETERIORATED 0.1 Negative 624 Building 4 Exterior Room 5 D Door Frame Wood DETERIORATED 0.2 Negative 625 Building 4 Interior Room 5 D Door Wood Intact 0.1 Negative 626 Building 4 Interior Room 5 D Door Frame Wood Intact 0.3 Negative 627 Building 4 Interior Room 5 A Window Sill Gypsum Intact 0.1 Negative Aluminum 628 Building 4 Interior Room 5 A Wall Gypsum Intact 0.1 Negative 629 Building 4 Interior Room 5 B Wall Wood Intact 0.0 Negative 630 Building 4 Interior Room 5 C Wall Wood Intact 0.0 Negative 631 Building 4 Interior Room 5 D Wall Wood Intact 0.1 Negative 632 Building 4 Interior Room 5 Ceiling Gypsum Intact 0.1 Negative 633 Building 4 Interior Room 5 Baseboard Wood Intact 0.1 Negative 634 Building 4 Exterior Bathroom 2 B Door Wood DETERIORATED 0.3 Negative 635 Building 4 Exterior Bathroom 2 B Door Frame Wood DETERIORATED 0.5 Negative 636 Building 4 Interior Bathroom 2 B Door Wood DETERIORATED 0.2 Negative 637 Building 4 Interior Bathroom 2 B Door Frame Wood DETERIORATED 0.4 Negative 638 Building 4 Interior Bathroom 2 D Window Frame Wood Intact 0.1 Negative Aluminum L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 22 of 28 6/22/2017 2:26:46 PM

64 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 639 Building 4 Interior Bathroom 2 A Wall Gypsum Intact 0.1 Negative 640 Building 4 Interior Bathroom 2 B Wall Gypsum Intact 0.2 Negative 641 Building 4 Interior Bathroom 2 C Wall Gypsum Intact 0.2 Negative 642 Building 4 Interior Bathroom 2 D Wall Gypsum Intact 0.1 Negative 643 Building 4 Interior Bathroom 2 A Wall Tile Intact 0.0 Negative 644 Building 4 Interior Bathroom 2 B Wall Tile Intact 0.1 Negative 645 Building 4 Interior Bathroom 2 C Wall Tile Intact 0.2 Negative 646 Building 4 Interior Bathroom 2 D Wall Tile Intact 0.1 Negative 647 Building 4 Interior Bathroom 2 Ceiling Gypsum DETERIORATED 0.1 Negative 648 Building 4 Interior Bathroom 2 Floor Tile Intact 0.0 Negative 649 Building 4 Perimeter Exterior North Side A Window Frame Metal Intact 0.0 Negative Aluminum 650 Building 4 Perimeter Exterior North Side A Window Well Wood Intact 0.7 POSITIVE Boarded Up 651 Building 4 Perimeter Exterior North Side A Window Frame Wood DETERIORATED 0.7 POSITIVE Boarded Up 652 Building 4 Perimeter Exterior North Side A Trim Wood DETERIORATED 0.1 Negative Plywood 653 Building 4 Perimeter Exterior North Side A Wall Stucco Intact 0.4 Negative 654 Building 4 Perimeter Exterior North Side A Wall Stucco Intact 0.3 Negative 655 Building 4 Perimeter Exterior North Side A Wall Stucco Intact 0.3 Negative 656 Building 4 Perimeter Exterior North Side A Wall Stucco Intact 0.5 Negative 657 Building 4 Perimeter Exterior North Side A Eaves Wood DETERIORATED 1.5 POSITIVE 658 Building 4 Perimeter Exterior North Side A Fascia Wood DETERIORATED 1.0 POSITIVE 659 Building 4 Perimeter Exterior North Side A Eaves Wood DETERIORATED 0.4 Negative Newer Addition 660 Building 4 Perimeter Exterior North Side A Rafters Wood DETERIORATED 0.3 Negative Newer Addition 661 Building 4 Perimeter Exterior North Side A Ceiling Stucco Intact 0.5 Negative 662 Building 4 Perimeter Exterior North Side A Corner Board Wood DETERIORATED 0.4 Negative 663 Building 4 Perimeter Exterior East Side B Window Frame Wood DETERIORATED 0.1 Negative Fixed 664 Building 4 Perimeter Exterior East Side B Window Bars Metal DETERIORATED 0.1 Negative 665 Building 4 Perimeter Exterior East Side B Window Well Wood DETERIORATED 1.0 POSITIVE Fixed 666 Building 4 Perimeter Exterior East Side B Window Sash Wood DETERIORATED 0.7 POSITIVE Fixed 667 Building 4 Perimeter Exterior East Side B Window Frame Wood DETERIORATED 1.3 POSITIVE Fixed L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 23 of 28 6/22/2017 2:26:46 PM

65 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 668 Building 4 Perimeter Exterior East Side B Window Frame Wood DETERIORATED 0.2 Negative Boarded Up 669 Building 4 Perimeter Exterior East Side B Trim Wood DETERIORATED 0.1 Negative Plywood 670 Building 4 Perimeter Exterior East Side B Window Well Wood DETERIORATED 0.0 Negative Boarded Up 671 Building 4 Perimeter Exterior East Side B Window Frame Wood Intact 0.7 POSITIVE Boarded Up 672 Building 4 Perimeter Exterior East Side B Wall Stucco Intact 0.4 Negative 673 Building 4 Perimeter Exterior East Side B Wall Stucco Intact 0.3 Negative 674 Building 4 Perimeter Exterior East Side B Wall Stucco Intact 0.3 Negative 675 Building 4 Perimeter Exterior East Side B Wall Wood DETERIORATED 0.5 Negative 676 Building 4 Perimeter Exterior East Side B Eaves Wood DETERIORATED 1.2 POSITIVE 677 Building 4 Perimeter Exterior East Side B Rafters Wood DETERIORATED 1.3 POSITIVE 678 Building 4 Perimeter Exterior East Side B Column Wood DETERIORATED 1.1 POSITIVE Patio 679 Building 4 Perimeter Exterior East Side B Beam Wood DETERIORATED 0.3 Negative Patio 680 Building 4 Perimeter Exterior East Side B Ceiling Metal Intact 0.1 Negative Patio 681 Building 4 Perimeter Exterior East Side B Column Wood DETERIORATED 0.1 Negative Patio 682 Building 4 Perimeter Exterior East Side B Beam Wood DETERIORATED 0.2 Negative Patio 683 Building 4 Perimeter Exterior East Side B Ceiling Wood DETERIORATED 0.1 Negative Patio 684 Building 4 Perimeter Exterior East Side B Gutter Metal Intact 0.0 Negative 685 Building 4 Perimeter Exterior East Side B Ceiling Stucco Intact 0.3 Negative 686 Building 4 Perimeter Exterior East Side B Beam Wood DETERIORATED 0.5 Negative 687 Building 4 Perimeter Exterior East Side B Vent Wood DETERIORATED 0.7 POSITIVE 688 Building 4 Perimeter Exterior East Side B Access Panel Metal DETERIORATED 0.0 Negative 689 Building 4 Perimeter Exterior East Side B Bollard Metal DETERIORATED 1.2 POSITIVE 690 Building 4 Perimeter Exterior East Side B Bollard Metal DETERIORATED 1.3 POSITIVE 691 Building 4 Perimeter Exterior East Side B Parking Stripe Asphalt DETERIORATED 0.5 Negative 692 Building 4 Perimeter Exterior East Side B Parking Stripe Asphalt DETERIORATED 0.5 Negative 693 Building 4 Perimeter Exterior East Side B Corner Board Wood Intact 0.2 Negative 694 Building 4 Perimeter Exterior East Side B Frame Wood Intact 0.1 Negative For A/C Unit 695 Building 4 Perimeter Exterior East Side B Bench Wood DETERIORATED 0.3 Negative 696 Building 4 Perimeter Exterior East Side B Horizontal Trim Wood DETERIORATED 0.0 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 24 of 28 6/22/2017 2:26:46 PM

66 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 697 Building 4 Perimeter Exterior East Side B Vertical Trim Wood DETERIORATED 0.1 Negative 698 Building 4 Perimeter Exterior South Side C Window Well Wood Intact 0.3 Negative Aluminum 699 Building 4 Perimeter Exterior South Side C Window Frame Wood DETERIORATED 1.4 POSITIVE Aluminum 700 Building 4 Perimeter Exterior South Side C Window Frame Wood DETERIORATED 0.1 Negative Boarded Up 701 Building 4 Perimeter Exterior South Side C Wall Stucco Intact 0.4 Negative 702 Building 4 Perimeter Exterior South Side C Wall Stucco DETERIORATED 0.3 Negative 703 Building 4 Perimeter Exterior South Side C Wall Stucco Intact 0.3 Negative 704 Building 4 Perimeter Exterior South Side C Wall Stucco Intact 0.5 Negative 705 Building 4 Perimeter Exterior South Side C Eaves Wood Intact 0.3 Negative 706 Building 4 Perimeter Exterior South Side C Rafters Wood DETERIORATED 0.3 Negative 707 Building 4 Perimeter Exterior South Side C Column Metal DETERIORATED 0.3 Negative 708 Building 4 Perimeter Exterior South Side C Electric Utility Box Metal Intact 0.1 Negative 709 Building 4 Perimeter Exterior South Side C Trim Concrete DETERIORATED 0.3 Negative Yellow Stripe 710 Building 4 Perimeter Exterior South Side C Floor Concrete DETERIORATED 0.3 Negative 711 Building 4 Perimeter Exterior West Side D Window Well Wood DETERIORATED 0.7 POSITIVE Boarded Up 712 Building 4 Perimeter Exterior West Side D Window Frame Wood DETERIORATED 0.7 POSITIVE Boarded Up 713 Building 4 Perimeter Exterior West Side D Window Bars Metal DETERIORATED 0.2 Negative 714 Building 4 Perimeter Exterior West Side D Window Well Wood DETERIORATED 0.2 Negative Aluminum 715 Building 4 Perimeter Exterior West Side D Window Frame Wood DETERIORATED 0.2 Negative Aluminum 716 Building 4 Perimeter Exterior West Side D Window Well Wood DETERIORATED 0.5 Negative Double Hung 717 Building 4 Perimeter Exterior West Side D Window Sash Wood DETERIORATED 0.7 POSITIVE Double Hung 718 Building 4 Perimeter Exterior West Side D Window Frame Wood DETERIORATED 0.9 POSITIVE Double Hung 719 Building 4 Perimeter Exterior West Side D Wall Stucco Intact 0.4 Negative 720 Building 4 Perimeter Exterior West Side D Wall Stucco Intact 0.5 Negative 721 Building 4 Perimeter Exterior West Side D Wall Stucco Intact 0.5 Negative 722 Building 4 Perimeter Exterior West Side D Wall Stucco Intact 0.5 Negative 723 Building 4 Perimeter Exterior West Side D Eaves Wood DETERIORATED 0.3 Negative Newer 724 Building 4 Perimeter Exterior West Side D Fascia Wood DETERIORATED 0.2 Negative Newer 725 Building 4 Perimeter Exterior West Side D Eaves Wood DETERIORATED 0.7 POSITIVE L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 25 of 28 6/22/2017 2:26:46 PM

67 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 726 Building 4 Perimeter Exterior West Side D Rafters Wood DETERIORATED 1.0 POSITIVE 727 Building 4 Perimeter Exterior West Side D Fascia Wood DETERIORATED 0.5 Negative 728 Building 4 Perimeter Exterior West Side D Electric Utility Box Metal Intact 0.0 Negative 729 Building 4 Perimeter Exterior West Side D Vent Wood Intact 0.7 POSITIVE 730 Building 4 Perimeter Exterior West Side D Post Metal Intact 0.2 Negative 731 Building 4 Perimeter Exterior West Side D Pipe Metal DETERIORATED 0.0 Negative 732 Building 4 Perimeter Exterior West Side D Corner Board Wood DETERIORATED 0.5 Negative 733 Building 4 Perimeter Exterior Shed 1 D Door Metal Intact 0.1 Negative 734 Building 4 Perimeter Exterior Shed 1 D Door Frame Metal Intact 0.1 Negative 735 Building 4 Perimeter Exterior Shed 1 A Wall Metal Intact 0.0 Negative 736 Building 4 Perimeter Exterior Shed 1 B Wall Metal Intact 0.0 Negative 737 Building 4 Perimeter Exterior Shed 1 C Wall Metal Intact 0.1 Negative 738 Building 4 Perimeter Exterior Shed 1 D Wall Metal Intact 0.0 Negative 739 Building 4 Perimeter Exterior Shed 1 Roof Trim Metal Intact 0.1 Negative 740 Building 4 Perimeter Exterior Shed 2 D Door Metal Intact 0.0 Negative 741 Building 4 Perimeter Exterior Shed 2 D Door Frame Metal Intact 0.1 Negative 742 Building 4 Perimeter Exterior Shed 2 A Wall Metal Intact 0.1 Negative 743 Building 4 Perimeter Exterior Shed 2 B Wall Metal Intact 0.0 Negative 744 Building 4 Perimeter Exterior Shed 2 C Wall Metal Intact 0.0 Negative 745 Building 4 Perimeter Exterior Shed 2 D Wall Metal Intact 0.0 Negative 746 Building 4 Perimeter Exterior Shed 2 Roof Trim Metal Intact 0.0 Negative 747 Building 5 Interior Main Room A Wall Plaster DETERIORATED 0.0 Negative 748 Building 5 Interior Main Room B Wall Plaster DETERIORATED 0.1 Negative 749 Building 5 Interior Main Room C Wall Plaster DETERIORATED 0.2 Negative 750 Building 5 Interior Main Room D Wall Plaster DETERIORATED 0.2 Negative 751 Building 5 Interior Main Room B Wall Gypsum DETERIORATED 0.1 Negative 752 Building 5 Interior Main Room Ceiling Wood DETERIORATED 0.1 Negative 753 Building 5 Interior Main Room Beam Wood DETERIORATED 0.1 Negative 754 Building 5 Interior Main Room D Electrical Panel Metal Intact 0.0 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 26 of 28 6/22/2017 2:26:46 PM

68 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 755 Building 5 Interior Main Room Tread Wood Intact 0.0 Negative 756 Building 5 Interior Main Room Stringer Wood Intact 0.1 Negative 757 Building 5 Interior Main Room Deck Wood Intact 0.0 Negative 758 Building 5 Interior Main Room Shelf Wood DETERIORATED 0.1 Negative 759 Building 5 Perimeter Exterior North Side A Door Wood DETERIORATED 0.1 Negative To Shed 760 Building 5 Perimeter Exterior North Side A Door Frame Wood DETERIORATED 0.2 Negative To Shed 761 Building 5 Perimeter Exterior North Side A Wall Stucco Intact 0.3 Negative 762 Building 5 Perimeter Exterior North Side A Wall Stucco Intact 0.5 Negative 763 Building 5 Perimeter Exterior North Side A Wall Stucco Intact 0.4 Negative 764 Building 5 Perimeter Exterior North Side A Wall Wood DETERIORATED 0.2 Negative Shed 765 Building 5 Perimeter Exterior North Side A Column Metal DETERIORATED 0.0 Negative 766 Building 5 Perimeter Exterior North Side A Beam Metal Intact 0.2 Negative 767 Building 5 Perimeter Exterior North Side A Ceiling Metal Intact 0.2 Negative 768 Building 5 Perimeter Exterior North Side A Floor Concrete DETERIORATED 0.2 Negative 769 Building 5 Perimeter Exterior East Side B Wall Stucco Intact 0.5 Negative 770 Building 5 Perimeter Exterior East Side B Wall Stucco Intact 0.5 Negative 771 Building 5 Perimeter Exterior East Side B Wall Stucco Intact 0.2 Negative 772 Building 5 Perimeter Exterior East Side B Wall Stucco Intact 0.2 Negative 773 Building 5 Perimeter Exterior East Side B Garage Door Metal Intact 0.0 Negative 774 Building 5 Perimeter Exterior East Side B Garage Door Frame Wood DETERIORATED 0.2 Negative 775 Building 5 Perimeter Exterior East Side B Garage Door Metal Intact 0.0 Negative 776 Building 5 Perimeter Exterior East Side B Garage Door Frame Wood DETERIORATED 0.2 Negative 777 Building 5 Perimeter Exterior East Side B Column Metal DETERIORATED 0.1 Negative 778 Building 5 Perimeter Exterior East Side B Beam Metal Intact 0.2 Negative 779 Building 5 Perimeter Exterior East Side B Ceiling Metal Intact 0.2 Negative 780 Building 5 Perimeter Exterior East Side B Trim Metal DETERIORATED 0.0 Negative Car Lift 781 Building 5 Perimeter Exterior East Side B Bollard Metal DETERIORATED 0.1 Negative 782 Building 5 Perimeter Exterior East Side B Parking Stripe Asphalt DETERIORATED 0.2 Negative 783 Building 5 Perimeter Exterior South Side C Wall Stucco Intact 0.5 Negative L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 27 of 28 6/22/2017 2:26:46 PM

69 FIELD DATA REPORT Project Name: 5 Buildings Address: 1400 E. Mission Boulevard Pomona,CA Protocol:LA County Sample Unit ID / Location Room Equivalent Side Component Substrate Condition Lead Results Comments 784 Building 5 Perimeter Exterior South Side C Wall Stucco Intact 0.5 Negative 785 Building 5 Perimeter Exterior South Side C Wall Stucco Intact 0.4 Negative 786 Building 5 Perimeter Exterior South Side C Wall Stucco Intact 0.2 Negative 787 Building 5 Perimeter Exterior West Side D Wall Stucco Intact 0.5 Negative 788 Building 5 Perimeter Exterior West Side D Wall Stucco Intact 0.4 Negative 789 Building 5 Perimeter Exterior West Side D Wall Stucco Intact 0.4 Negative 790 Building 5 Perimeter Exterior West Side D Wall Wood DETERIORATED 0.3 Negative Shed 791 Building 5 Perimeter Exterior West Side D Column Wood DETERIORATED 0.1 Negative Shed 792 Building 5 Perimeter Exterior West Side D Beam Wood DETERIORATED 0.2 Negative Shed 793 Building 5 Perimeter Exterior West Side D Ceiling Wood DETERIORATED 0.1 Negative Shed 794 Building 5 Perimeter Exterior West Side D Electric Utility Box Metal DETERIORATED 0.1 Negative 795 Calibration Common End of Job 0.0 mg/cm2 Standard Wood Intact 0.0 Negative 796 Calibration Common End of Job 0.0 mg/cm2 Standard Wood Intact 0.0 Negative 797 Calibration Common End of Job 0.0 mg/cm2 Standard Wood Intact 0.1 Negative 798 Calibration Common End of Job 1.0 mg/cm2 Standard Wood Intact 1.0 POSITIVE 799 Calibration Common End of Job 1.0 mg/cm2 Standard Wood Intact 1.0 POSITIVE 800 Calibration Common End of Job 1.0 mg/cm2 Standard Wood Intact 1.0 POSITIVE L.A. County DHS action level for lead paint is 0.7 mg/cm2. Positive is defined as XRF sampling with levels at or above 0.7 mg/cm2. 28 of 28 6/22/2017 2:26:46 PM

70 APPENDIX C PROJECT MONITOR / INSPECTOR / RISK ASSESSOR CERTIFICATE(S)

71

72 APPENDIX D INSURANCE CERTIFICATES

73

74