POSH BRISTOL TORBEX SHOWER BASE

Size: px
Start display at page:

Download "POSH BRISTOL TORBEX SHOWER BASE"

Transcription

1 page of imensions are nominal measurements only. SPEIFITIONS Recommended Use Material omestic, hotel and commercial Torbex High Strength omposite imensions mm x mm x 9mm mm x mm x 9mm 0mm x mm x 9mm mm x mm x mm mm x mm x mm Waste Outlet entre Rear To see the complete RISTOL range go to LENING REOMMENTIONS We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. amage caused by any improper treatment is not covered by the product warranty- refer to Warranty onditions. isclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. imensions are nominal measurements only. imensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors. Tech Page Version

2 page of ETIL SLE : ETIL SLE : ETIL SLE : RWN RO /0/0 HEKE Q TOREX SHOWER SE - x PPROVE RWN RO /0/0 WG NO OMPOSITE MTERILS ENGINEERING HEKE x - mm raised lip SLE 0. : Q TOREX SHOWER SE - x PPROVE SLE 0. : OMPOSITE MTERILS ENGINEERING SHEET OF WG NO x RWN - mm raised lip RO /0/0 HEKE Q SHEET OF PPROVE 0. Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference

3 page of ETIL SLE / ETIL SLE / ETIL SLE / RWN RO /0/0 OMPOSITE MTERILS ENGINEERING RWN HEKE RWN RO /0/0 RO OMPOSITE MTERILS /0/0 ENGINEERING OMPOSITE MTERILS ENGINEERING HEKE Q HEKE Q Q TOREX SHOWER SE - 0x TOREX SHOWER SE - 0x TOREX SHOWER SE - 0x PPROVE PPROVE PPROVE WG NO WG WG NO NO SLE SLE SLE 0. : SHEET OF 0. : 0. : SHEET SHEET OF OF ETIL SLE / ETIL SLE / RWN Ryan Oldfield //0 HEKE OMPOSITE MTERILS ENGINEERING Q PPROVE RWN Ryan Oldfield x SHOWER //0 SE HEKE Q SLE WG NO x OMPO SHEET OF x SH PPROVE SLE

4 ET SLE page of.90 ETIL SLE : 90 RWN Ryan Oldfield //0 HEKE Q OMPOSITE MTERILS ENGINEERING X SHOWER SE

5 page of INSTLLTION INSTRUTIONS The shower base should be visually checked for defects prior to installation. Failure to do so will void warranty. Note: Please check minimum/maximum adjustments of your shower screen before commencing the installation of base. The following points should be taken into account to determine if the installation method used will be suitable for the screen selected. Wall lining thickness heck in depth Tiled or crylic walls Front and return tile flange. Floorboards or sheet flooring must cover the entire underside of the Posh ristol shower base. ut a hole through the floor no greater than 00mm x 00mm. oncrete should be cut wider at 00mm x 00mm. If you are doing a renovation, the floorboards must be checked for durability as rotting may have occurred and the flooring may need to be replaced.. The Posh ristol shower base can be installed on silicone or building adhesive over the total base area. Lay the base on the floor and check that it is level on both sides as well as the front and the rear. This will ensure that the base drains effectively to the waste outlet. Note: If your floor is not level, use a cement based tile adhesive spread over the floor with a mm notched trowel to ensure the base is fully supported. ement based tile adhesive must be left to cure before installing the Posh ristol shower base.. It is essential to test for water run off to the waste outlet prior to commencing the installation of the shower walls. This will ensure the shower base is draining correctly. Failure to follow this step will void the guarantee.. It is highly recommended that you cover and protect the Posh ristol shower base throughout installation and until it comes into service.. Finally apply silicone to the bottom edge of the shower wall to the shower base before the screen is fitted. You will also require silicone around the shower base outlet. LENING: The surface of the Posh ristol shower base will resist most surface build up. To preserve the superior appearance of the shower based it is best cleaned with a soft cloth with warm soapy water, or general household detergent. VOI RSIVES Please avoid using abrasive cleaning products, as well as steel wool and abrasive cloths. WTER RESISTNT PLSTER-OR INSTLLTION: The Posh ristol shower base has a 9mm wide tile flange. Place the base against the framework, install water resistant plasterboard directly on top of the tile flange and seal the joint with silicone sealant. VILLOR INSTLLTION: When using Villaboard, the Posh ristol shower base will need to be checked into the framework at a minimum of mm. Install the Villaboard directly on top of the tile flange and seal the joint with a silicone sealant. WTER RESISTNT PLSTER OR VILL OR WTER RESISTNT PLSTER OR WLL SHEETING OR TILES SILIONE EXPNSIONS JOINT ETWEEN SE N WLL PLSTER SILIONE EXPNSIONS JOINT ETWEEN SE N WLL LINING VILL OR WLL SHEETING OR TILES SILIONE EXPNSIONS JOINT ETWEEN SE & VILL OR SILIONE EXPNSIONS JOINT ETWEEN SE & WLL LINING STU N OTTOM PLTE WITH MM HEKOUT (Wood Floor) (oncrete Floor) Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference

6 page of FITTING INSTRUTIONS FOR RISTOL WSTE OUTLETS over Silicone Ring pply silicone in this area to the fill the gap between the outlet and the shower base. pply a small amount of silicone on this surface Outlet Outer Tension Ring. Remove outer tension ring and silicone ring from the assembly.. pply a small amount of silicone onto the top flange and place silicone ring onto the silicone.. Place the outlet into the outlet hole, ensuring that the sealing ring is between the outlet and the outlet hole.. pply silicone to the underside of the hole filling the gap between the outlet and the base.. Replace the outer tension ring from the underside of the base screwing in a clockwise direction onto the outlet.. Tighten the outer tension ring with a spanner, do not over tighten.. ttach plumbing connections to the threaded outlet.. heck for water tightness, tighten further if necessary. on t risk it, use a licensed plumber.