1 4809 W. Hwy 290 Sunset Valley, TX October 27, Permit Ph: Fax: Ph: Fax:

2 A B 36" Channel Letters: 68.9 SF 3'-9" x 5'-3" Steer Logo: 19.7 SF Site Plan C 36" Channel Letters: 68.9 SF D 36" Channel Letters: 68.9 SF E 4'-0" x 12'-0" Monument at 8'-0" OAH: 48 SF A Red LED illuminated band to be mounted to cornice on all elevations. B E C D Ph: Fax: Page 2 of 14

3 Front Elevation 89'-9 ½" 16'-2" 12'-10 3/4" 23'-1" 21'-1" 17'-0 ½" 19'-2 ½" 5'-7" Red LED illuminated band to be mounted to cornice. Scale: 1/16"=1' 15'-5 3/8" 4'-5 ½" 36" 12" A 36" Channel Letters (Internally Illuminated w/led) Utilized Square Footage: 68.9 Scale: ¼"=1' Ph: Fax: Page 3 of 14

4 Front Elevation 89'-9 ½" 16'-2" 12'-10 3/4" 5'-3" 3'-9" 23'-1" 21'-1" 17'-0 ½" 19'-2 ½" 5'-7" Red LED illuminated band to be mounted to cornice. Scale: 1/16"=1' B Steer Logo (Halo Illuminated w/led) Utilized Square Footage: 19.7 Scale: 3/8"=1' Ph: Fax: Page 4 of 14

5 Left Elevation 78-2" 16'-2" 19'-2 ½" 21'-1" 23'-1" 5'-7" Red LED illuminated band to be mounted to cornice. Scale: 1/16"=1' 15'-5 3/8" 4'-5 ½" 36" 12" C 36" Channel Letters (Internally Illuminated w/led) Utilized Square Footage: 68.9 Scale: ¼"=1' Ph: Fax: Page 5 of 14

6 Right Elevation 78-2" 16'-8 5/8" 15'-5 3/8" 4'-5 ½" 23'-1" 21'-1" 19'-2 ½" 5'-7" Red LED illuminated band to be mounted to cornice. Scale: 1/16"=1' 36" 12" 36" Channel Letters (Internally Illuminated w/led) Utilized Square Footage: 68.9 Scale: ¼"=1' D Ph: Fax: Page 6 of 14

7 48 SF Monument 12'-0" 11'-1 ½" 3'-10" 2" 8'-0" 8 5/8" 4'-0" 2'-2" 48 SF Monument (Internally Illuminated) Utilized Square Footage: 48.0 Scale: 3/8"=1' E Ph: Fax: Page 7 of 14

8 15'-5 3/8" MATERIAL FINISH COLORS Returns Faces Faces Trimcap 4'-5 ½" 1'-0" 3'-0" 5 ½" SIGN TYPE: LH-36RMLTR-XLED / INTERNALLY ILLUMINATED CHANNEL LETTERS / 68.9 SQ.FT. 3" WHITE ACRYLIC DISC W/ BLACK VINYL REGISTRATION MARK SCALE : ½" = 1'-0" Pre-finished Black Aluminum 7328 White Acrylic 2283 Red Acrylic w/ White Perforated Vinyl Black ELECTRICAL REQUIREMENTS Total: 4.0 Amps ( ) 1 120V 20A Circuit Required. ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS (INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS. "LONGHORN": FACES: #2283 RED ACRYLIC W/ WHITE PERFORATED VINYL APPLIED 1ST SURFACE (LETTERS TO APPEAR WHITE DURING DAY & RED AT NIGHT). RETURNS: 5" DEEP, PRE-FINISHED BLACK ALUMINUM W/ BLACK TRIMCAP. NOTE: INTERIOR OF LETTERS TO BE PAINTED W/ WHITE LIGHT ENHANCEMENT PAINT. ILLUMINATION: GE RED LED MODULES POWERED BY REMOTE POWER SUPPLIES. "STEAKHOUSE": FACES: #7328 WHITE ACRYLIC. RETURNS: 5" DEEP, PRE-FINISHED BLACK ALUMINUM W/ BLACK TRIMCAP. NOTE: INTERIOR OF LETTERS TO BE PAINTED W/ WHITE LIGHT ENHANCEMENT PAINT. ILLUMINATION: GE WHITE LED MODULES POWERED BY REMOTE POWER SUPPLIES. PRE-FINISHED.040 BLACK ALUMINUM RETURNS WITH BLACK 1" TRIM CAP.063 ALUM BACKS (BLACK) GE RED LED MODULES 120V/12VDC POWER SUPPLY IN BOXES BEHIND WALL 14 AWL WIRING FROM POWER SUPPLY TO LED MODULES 5" PRE-FINISHED.040 BLACK ALUMINUM RETURNS WITH BLACK 1" TRIM CAP.063 ALUM BACKS (BLACK) GE WHITE LED MODULES 120V/12VDC POWER SUPPLY IN BOXES BEHIND WALL 14 AWL WIRING FROM POWER SUPPLY TO LED MODULES 5" CUSTOMER TO PROVIDE: (For New / Remodel Construction) ADEQUATE BEHIND THE WALL BACKING AND ACCESS AS REQUIRED TO INSTALL SIGNAGE. CUSTOMER TO FORWARD COPY OF FINAL APPROVED SIGNAGE DRAWINGS TO BUILDING SITE CONTACT SO THAT THESE PROVISIONS CAN BE MADE DURING CONSTRUCTION AND PRIOR TO SIGN INSTALLATION. #2283 RED ACRYLIC FACES W/ WHITE PERFORATED VINYL CONDUIT THRU WALL TO LETTERS BY SIGN INSTALLER #7328 WHITE ACRYLIC FACES CONDUIT THRU WALL TO LETTERS BY SIGN INSTALLER ALL BRANCH (PRIMARY ELECTRICAL SERVICE) CIRCUIT S & FINAL CONNECTION TO EACH SIGN (WITHIN 5 FT.) TO BE BY CERTIFIED ELECTRICIAN: A. All branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit). B. Sign circuits must not be shared with other loads such as lighting, air conditioning, and other equipment. C. Properly sized ground wire that can be traced back to the breaker panel must be provided. D. Number and size of circuits for each sign to meet Federal Heath Sign's requirement. Any deviation from the above recommendations may result in: 1. Damage to or improper operation of the sign(s). 2. Delays and additional costs. Notes: Á Certain electrical components of signs will fail prematurely if signs are not shut-off for a period of time, once, each day. For best performance, we recommend signs to be connected to an automatic controlling device such as an Energy Management System, Time Clock or Photo Cell that will automatically shut-off the sign for a period of time, each day. Failure to do so will cause damage to the electrical components of the sign and will void the warranty. Á Some dimming devices will also adversely affect sign electrical components, causing failure. Any dimming of the sign without consultation with Federal Heath Sign Co. will void the warranty. INSTALLER IS RESPONSIBLE FOR: PROVIDING AND INSTALLING ALL COMPONENTS REQUIRED TO RUN SECONDARY WIRING (CONNECTORS, GTO CONDUIT, ETC.) TO BE DETERMINED BY LOCAL CODE AND SITE CONDITIONS. PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS. SEALING BUILDING PENETRATIONS WITH SILICONE TO PREVENT MOISTURE EXTERIOR LOCATIONS. ¼ WEEP HOLES IN BOTTOM OF LETTERS (2 MIN.) GALVANIZED OR STAINLESS STEEL TOGGLE BOLTS. IF WALL CONDITIONS ARE NOT CONDUCIVE TO TOGGLE BOLT MOUNTING, ALTERNATE MOUNTING METHODS WILL BE NEEDED. J-BOX BY OTHERS TYPICAL L.E.D. CHANNEL LETTER / "Longhorn" GE LED LOW VOLTAGE LIGHTING SYSTEM U.L. LISTED - CLASS 2 - CONFORMS TO U.L N.E.C. 600 STANDARDS GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY WALL CONDITIONS IN THE FIELD. 2. TYPE, SIZE & NUMBER OF FASTENERS TO BE DETERMINED. 3. ALL BOLT TO BE DRILLED AND OR PUNCHED. 4. ISOLATE ALUMINUM FROM STEEL. ¼ WEEP HOLES IN BOTTOM OF LETTERS (2 MIN.) GALVANIZED OR STAINLESS STEEL TOGGLE BOLTS. IF WALL CONDITIONS ARE NOT CONDUCIVE TO TOGGLE BOLT MOUNTING, ALTERNATE MOUNTING METHODS WILL BE NEEDED. J-BOX BY OTHERS TYPICAL L.E.D. CHANNEL LETTER / "Steakhouse" GE LED LOW VOLTAGE LIGHTING SYSTEM U.L. LISTED - CLASS 2 - CONFORMS TO U.L N.E.C. 600 STANDARDS GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY WALL CONDITIONS IN THE FIELD. 2. TYPE, SIZE & NUMBER OF FASTENERS TO BE DETERMINED. 3. ALL BOLT TO BE DRILLED AND OR PUNCHED. 4. ISOLATE ALUMINUM FROM STEEL. Page 8 of 14

9 SIGN TYPE: LH-36RMLTR-XLED / INTERNALLY ILLUMINATED CHANNEL LETTERS Page 9 of 14

10 5'-3" MATERIAL FINISH COLORS Face & Returns Logo Back Black Painted Aluminum White Polycarbonate 3'-9" ELECTRICAL REQUIREMENTS Total: 1.0 Amps ( ) 1 120V 20A Circuit Required. ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS (INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS. SIGN TYPE: LH-45STEER-LED / HALO-ILLUMINATED REVERSE CHANNEL STEER / SQ.FT. SCALE : 1" = 1'-0" "LONGHORN": FACE & RETURNS: FABRICATED FROM ALUMINUM & PAINTED BLACK NOTE: INTERIOR OF LETTERS TO BE PAINTED W/ WHITE LIGHT ENHANCEMENT PAINT. ILLUMINATION: GE WHITE LED MODULES POWERED BY REMOTE POWER SUPPLIES..063 BLACK ALUMINUM RETURNS.125 ALUM FACE (BLACK) 3" 2" GE WHITE LED MODULES 120V/12VDC POWER SUPPLY IN BOXES BEHIND WALL 14 AWL WIRING FROM POWER SUPPLY TO LED MODULES CUSTOMER TO PROVIDE: (For New / Remodel Construction) ADEQUATE BEHIND THE WALL BACKING AND ACCESS AS REQUIRED TO INSTALL SIGNAGE. CUSTOMER TO FORWARD COPY OF FINAL APPROVED SIGNAGE DRAWINGS TO BUILDING SITE CONTACT SO THAT THESE PROVISIONS CAN BE MADE DURING CONSTRUCTION AND PRIOR TO SIGN INSTALLATION. ALL BRANCH (PRIMARY ELECTRICAL SERVICE) CIRCUIT S & FINAL CONNECTION TO EACH SIGN (WITHIN 5 FT.) TO BE BY CERTIFIED ELECTRICIAN: A. All branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit). B. Sign circuits must not be shared with other loads such as lighting, air conditioning, and other equipment. C. Properly sized ground wire that can be traced back to the breaker panel must be provided. D. Number and size of circuits for each sign to meet Federal Heath Sign's requirement. Any deviation from the above recommendations may result in: 1. Damage to or improper operation of the sign(s). 2. Delays and additional costs. Notes: Á Certain electrical components of signs will fail prematurely if signs are not shut-off for a period of time, once, each day. For best performance, we recommend signs to be connected to an automatic controlling device such as an Energy Management System, Time Clock or Photo Cell that will automatically shut-off the sign for a period of time, each day. Failure to do so will cause damage to the electrical components of the sign and will void the warranty. Á Some dimming devices will also adversely affect sign electrical components, causing failure. Any dimming of the sign without consultation with Federal Heath Sign Co. will void the warranty. INSTALLER IS RESPONSIBLE FOR: PROVIDING AND INSTALLING ALL COMPONENTS REQUIRED TO RUN SECONDARY WIRING (CONNECTORS, GTO CONDUIT, ETC.) TO BE DETERMINED BY LOCAL CODE AND SITE CONDITIONS. PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS. SEALING BUILDING PENETRATIONS WITH SILICONE TO PREVENT MOISTURE EXTERIOR LOCATIONS..177 WHITE POLY CONDUIT THRU WALL TO LETTERS BY SIGN INSTALLER ¼ WEEP HOLES IN BOTTOM OF LETTERS (2 MIN.) GALVANIZED OR STAINLESS STEEL TOGGLE BOLTS. IF WALL CONDITIONS ARE NOT CONDUCIVE TO TOGGLE BOLT MOUNTING, ALTERNATE MOUNTING METHODS WILL BE NEEDED. J-BOX BY OTHERS TYPICAL L.E.D. REVERSE CHANNEL "STEER" GE LED LOW VOLTAGE LIGHTING SYSTEM U.L. LISTED - CLASS 2 - CONFORMS TO U.L N.E.C. 600 STANDARDS GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY WALL CONDITIONS IN THE FIELD. 2. TYPE, SIZE & NUMBER OF FASTENERS TO BE DETERMINED. 3. ALL BOLT TO BE DRILLED AND OR PUNCHED. 4. ISOLATE ALUMINUM FROM STEEL. Page 10 of 14

11 SIGN TYPE: LH-45STEER-LED / HALO-ILLUMINATED REVERSE CHANNEL STEER Page 11 of 14

12 METAL COPING PASS THRU WALL W/ WATERPROOFED SYSTEM (BY: INSTALLER) RED L.E.D STRIPE (BY: GE) EIFS CORNICE POWER SUPPLIES IN W/P BOX MOUNTED TO WALL (BY: INSTALLER) CUT-OFF SOURCE TO BE ABLE TO DISCONNECT ALL L.E.D. EACH PRIMARY. SIGN TYPE: BORDER LED STRIPE / WALL CORNICE AREA NOT TO SCALE Page 12 of 14

13 12'-0" 5" 1'-0" 5" 4" RADIUS CORNERS 4'-0" 2'-2" 2 ½" 8 5/8" 3'-10" 8'-0" 2" REVEAL TYP. NOTE: BASE MATERIAL & SIZE WILL BE DETERMINED BY LONGHORN CORP. GENERAL CONTRACTOR IS RESPONSIBLE FOR SUPPLYING LABOR & MATERIAL TO INSTALL BASE. SIGN TYPE: LH-4X12MON-LED / INTERNALLY ILLUMINATED MONUMENT SIGN / SQ.FT. CABINET: CONVENTIONAL STEEL ANGLE & ALUMINUM SKIN PAINTED GLOSS BLACK ON ALL EXTERIOR SURFACES (INCLUDING REVEAL). END VIEW SCALE : ½" = 1'-0" "LONGHORN": INTERNALLY ILLUMINATED CHANNEL LETTERS. FACES: #2283 RED ACRYLIC W/ WHITE PERFORATED VINYL APPLIED 1ST SURFACE. (LETTERS TO APPEAR WHITE DURING DAY & RED AT NIGHT). RETURNS: 5" DEEP, PRE-FINISHED GLOSS BLACK ALUMINUM W/ BLACK TRIMCAP. NOTE: INTERIOR OF LETTERS TO BE PAINTED W/ WHITE LIGHT ENHANCEMENT PAINT. ILLUMINATION: RED GE LED MODULES. "STEAKHOUSE": COPY TO BE ROUTED OUT OF ALUMINUM FACE & BACKED UP W/ 7328 WHITE LEXAN. ILLUMINATION: DAYLIGHT H.O. FLUORESCENT LAMPS. : WHITE OPAQUE VINYL. Gloss Black Paint MATERIAL FINISH COLORS Cabinet Returns Faces Faces Trimcap Pre-finished Black Aluminum 7328 White Lexan 2283 Red Acrylic w/ White Perforated Vinyl Black NOTE: THERE WILL BE A STUB PIPE OUT OF THE MAIN CABINET THAT WILL BE USED IN THE MOUNTING IN THE FIELD FOR THE STUB CONNECTION. Page 13 of 14

14 C/L LAYOUT FOR SIGN TYPE: LH-4X12MON-LED / INTERNALLY ILLUMINATED MONUMENT SIGN Page 14 of 14