111 K STREET, NORTH EAST

Size: px
Start display at page:

Download "111 K STREET, NORTH EAST"

Transcription

1 W AS H ING TO N, D.C. 111 K STREET, NORTH EAST Washington, D.C. BUILDING FEATURES Boutique 8,980 SF floors with 9-foot ceilings, ideal for full & partial floor users Full height glass on all sides A 3,000 square-foot conference center Stunning rooftop terrace Exclusive underground parking Lobby concierge Fitness center and showers Designed to LEED Platinum standards Spec suites planned FULL FLOOR AVAILABILITIES ON FLOORS 5th & 11th LEASING OPPORTUNITIES: Adam Biberaj abiberaj@lpc.com Merrill Turnbull Mturnbull@lpc.com Beth Wilzbach BWilzbach@lpc.com

2 US CUSTOMS CAPITOL PLAZA NEW YORK AVE. METRO STATION NEIGHBORHOOD FEATURES NPR DC HOUSING AUTHORITY SMITHSONIAN ONE NOMA STATION WASHINGTON COLISEUM 70 Restaurants 50 Shops NORTH CAPITOL STR E ET KAISER PERMANENTE 1ST STREET GREYHOUND 2N D STREET 3N D STREET K STREET 6 hotels 111 2,400 new high-end residential properties FEDERAL ENERGY REGULATORY COMMISSION Direct Access to Metro, VRE, Amtrak and MARC trains Easy Access to 395 CNN AMERICAN PSYCHOLOGICAL ASSOCIATION CAREFIRST H STR E ET 10 minutes from Reagan National Airport AMTRAK HOTE LS POSTAL SQUARE BE ENERGIZED 111 K Street SEC RESTAU RANTS MASSACHUSETTS AVE. UNION STATION OFFICE BUILDI NG S E NTE RTAI NME NT FEDERAL JUDICIARY BUILDING E STR E ET M ETRO LOUISIANA AVE. COLUMB US DE L. AVE. CI RCLE 1ST STREET

3 TYPICAL FLOOR PLAN

4 K STREET TEST FIT No 2 TYPICAL FLOOR PLAN TYPICAL FLOOR PLAN TEST FIT 1 Executive Office 11 Offices 15 Workstations 2 Conference Rooms 4 Collaboration Areas FIRST STREET

5 BUILDING SPECIFICATIONS BUILDING SIZE Total Area: 84,264 gross square feet Number Of Floors: 11 Typical Floor Plate: 8,980 rentable square feet BUILDING STRUCTURE Structural System:: Cast-in-place reinforced concrete Structural Capacity: 80 lbs/sf live load, 20 lbs/sf dead load Column Spacing: 30 Typical Slab-to-Slab: 11-4 FINISHED CEILING HEIGHT Typical Floors: : 9-0 Main Lobby:: 24-0 ELEVATORS Number: Two passenger, one of which may be used as a swing service cab. Both elevators serve the parking garage Capacity: 3,500 lbs. Speed: 350 feet per minute PARKING Levels: 2 Spaces: 44 SECURITY ACCESS SYSTEM Perimeter and Elevator key-card access control ON-SITE PERSONNEL Security Guard/Concierge during business hours LIFE SAFETY SYSTEMS SPRINKLER SYSTEM Fully sprinklered building FIRE ALARM SYSTEM ADA compliant building fire detection and alarm system and public address system, ULapproved addressable fire management/alarm system compliant with all applicable code requirements AMENITIES Ground-floor Retail Conference Center at second floor Rooftop Terrace with dramatic 270 degree views, including to the U.S. Capitol Building Near the New York Avenue Red Line MetroRail station, adjacent to Union Station which is served by the Metro Red Line, Amtrak and MARC & VRE commuter rail lines, and located on the Metropolitan Branch Bicycle Trail Bicycle storage and locker / shower facilities for cyclists and runners Fitness facility GREEN FEATURES Curtainwall all around allows unrestricted access to daylight and views Location near public and alternative transportation routes Bicycle commuter facilities provided Storm water management plan, including a green roof, to reduce runoff Water conserving plumbing fixtures to reduce water usage Efficient mechanical equipment, high performance curtainwall and building systems management to reduce energy consumption A portion of electricity may be purchased from green sources Many building materials will have high recycled content and will be sourced locally EXTERIOR MATERIALS Clear low-e insulated glazing in custom aluminum curtainwall, with sound attenuation provided at the east façade on floors 3, 4 & 5 Painted architectural metal panels INTERIOR MATERIALS Main Lobby Floor Honed Marble Walls Double-height wood feature wall, lacquered panels, etched patterned glass, stone base and stainless steel reveals & accents Doors Ultra narrow stile stainless steel with clear glazing Ceiling Large luminescent panels with down lights in stainless steel accent strips, accent and wall-wash lights in soffits Main Elevator Lobby walls Back-painted glass, lacquered panels, stone base and stainless steel reveals & accents Ceiling floating gypsum board ceiling plane with accent down lights and cove wall-wash lighting PROJECT TEAM Developer: Architect: Structural Engineer: MEP Engineer: J Street Development Gensler KCE TOLK