VERTICALLY MOUNTED S210 BLOCKS (page 7.7) S210 TOWER SYSTEM (pages ) Mounting Options Wall 89D Bracket Wall 19 inch Rack 23 or 35 inch Frame

Size: px
Start display at page:

Download "VERTICALLY MOUNTED S210 BLOCKS (page 7.7) S210 TOWER SYSTEM (pages ) Mounting Options Wall 89D Bracket Wall 19 inch Rack 23 or 35 inch Frame"

Transcription

1 PRODUCTS CONNECTION SYSTEM (pages ) VERTICALLY MOUNTED BLOCKS (page 7.7) TOWER SYSTEM (pages ) FIELD TERMINATED 19 INCH PANELS (pages ) XLBET FRAMES (pages ) Racks Product Stard connectivity Mounts on S89D Medium to high Active equipment Ideal for high density s for telecommunications brackets, ideal for density applications eliminates need for applications where floor room or consolidation system upgrades requiring superior separate wall fields. space is at a premium. points. from fields. cable management. Ideal for mounting adjacent to modular patch panels. Category Mounting Options Wall 89D Bracket Wall 19 inch Rack 23 or 35 inch Frame Capacity Pair 32 Pair Pair Pair Pair 7 0

2 Racks SIEMON TECHNICAL SUPPORT ON PRODUCTS I talk to our customers every day about installation of our products in the field the response on the product line has been overwhelming. It s easy to work with, provides great installation flexibility, excellent transmission performance. One of the main advantages of the block is its ability to manage category 6 cables well. Since the outside diameter of cat 6 cable is larger than cat 5e cables, having enough room to route cable is a big consideration. Our blocks provide generous channels between connecting blocks to dress cables. This, the ability to have cables enter from the rear, helps minimize the amount of jacket that needs to be removed helps maintain pair geometry up to the point of termination. Once termination is complete, our designation label strips cover all cables, providing a clean, finished look to the installation. The solution also gives our installers greater flexibility on the job site. Siemon is the only manufacturer to offer field installable category 6 patch plugs. This lets Siemon installers make custom length assemblies right on the job site, eliminating the need to carry a variety of different assembly lengths cutting time required to complete a job. SECTION CONTENTS Connection System Field Termination Kits Connecting Block Designation Labels / Designation Label Sheets Tower System Tower Field Termination Kits Large-Scale Vertical Managers Small-Scale Vertical Managers Tower Optional Accessories Field-Terminated 19 Inch Panels Field-Terminated 19 Inch Panels with Managers Vertically Mounted Field Termination Kits Patch Plugs Assemblies to MC Assemblies XLBET Frames (See ) We ve also had very good feedback from customers who use the block in consolidation points. They like the flexibility cost savings it provides for work area Moves, Adds Changes. With the solution there s no need to re-pull horizontal cable from the telecommunications room to the work area. All changes can be made out at the work area, reducing time cost required for changes. Finally, we re very confident in the performance of our product. We like to refer to the as the stealth block because it s transparent when used in the consolidation point. It doesn t have any impact on channel performance. From a transmission stpoint, you don t even see it there! It s the best performing category 6 connecting block in the industry. 7 1

3 CONNECTION SYSTEM Racks INTERNAL CROSSTALK BARRIERS Achieve 360 pair isolation to provide superior NEXT performance (13dB NEXT margin over category 6 specifications).* PYRAMID WIRE ENTRY SYSTEM Separates paired conductors when lacing cables to simplify reduce installation time. UTILIZES SAME WIRING BASE FOOTPRINT AS STANDARD PRODUCTS TO BE FULLY COMPATIBLE WITH EXISTING MOUNTING AND CABLE MANAGEMENT SOLUTIONS CABLE ENTERING THROUGH ACCESS OPENINGS IN BASE IS CONCEALED BY DESIGNATION LABELS CABLE ACCESS OPENINGS Allow cables to be routed through the rear of the block directly to the point of termination. PATENTED STAND-OFF LEGS MAY BE DETACHED FROM THE BLOCK BEFORE, DURING, OR AFTER INSTALLATION ON 64-PAIR VERSION DESIGNATION STRIP WITH INTER- CHANGEABLE COLORED LABELS CAN BE MOUNTED BETWEEN EACH ROW OF CONNECTION SYSTEM HIGHLIGHTS *At the time of this catalog printing, category 6/class E specifications were under development. The Siemon Company s block is the highest performing connecting block in the telecommunications industry. The UTILIZES SAME TERMINATION PRACTICES AS EXISTING PRODUCT AND IS COMPATIBLE WITH ALL SINGLE-POSITION TERMINATION TOOLS block significantly exceeds proposed category 6 connecting hardware performance specifications. Its superior performance makes it ideal for consolidation point applications. 7 2

4 FIELD TERMINATION KITS Complete installation kits include wiring blocks with detachable legs*, connecting blocks, label holders with white designation labels. PART# AB2-64FT pair, field termination kit height: 45.7mm (1.80 in.), width: 272mm (10.71 in.), depth: 82.7mm (3.26 in.) AB2-128FT pair, field termination kit height: 91.4mm (3.60 in.), width: 272mm (10.71 in.), depth: 82.7mm (3.26 in.) AB2-192FT pair, field termination kit height: 275mm (10.81 in.), width: 272mm (10.71 in.), depth: 82.7mm (3.26 in.) Racks 4-pair impact tool seats connecting blocks terminates trims wires on both the cable cross-connect side of the connecting blocks. *Legs detachable on 64-pair version only / MULTI-PAIR IMPACT TOOL PAGE 11.6, CABLE ASSEMBLIES & PATCH PLUG PAGE CONNECTING BLOCK Siemon blocks terminate AWG (0.64mm 0.40mm) solid or 7-str wires. They also offer markings to designate tip ring conductors, color-coded pairs on each block Siemon s patent-pending Pyramid wire entry system to expedite lacing of pairs. C pair, connecting block DESIGNATION LABELS Siemon wiring blocks allow for designation labels to be mounted between each row of connecting blocks features markings on the side to clearly identify the termination type. Each label has 4-pair markings can also be used for color-coding. -HLDR Transparent plastic label holders, bag of six -LBL-(X) pair marked colored labels, bag of six Use (X) to specify color: 2 = white, 3 = red, 4 = gray, 5 = yellow, 6 = blue, 7 = green, 8 = violet, 9 = orange, 60 = brown / DESIGNATION LABEL SHEETS Siemon s / designation label sheets provide the ability to custom print labels used on or blocks. The sheets can be used to print 2-, 3-, 4-, or 5-pair labels eliminate the need to order separate sheets for different configurations. There are 20 labels per side both sides are marked so they can be reversed re-printed in case of an error. They are available in nine colors. -SHT-(X)* / Designation label sheets, package of six Use (X) to specify color: 2 = white, 3 = red, 4 = gray, 5 = yellow, 6 = blue, 7 = green, 8 = violet, 9 = orange, 60 = brown *Visit our web site or contact our Technical Support Department for labeling software. 7 3

5 Racks TOWER SYSTEM INCLUDES B1RMS CABLE MANAGERS WITH COVERS FOR HORIZONTAL CABLE DISTRIBUTION EACH TOWER COMES COMPLETE WITH THE APPROPRIATE QUANTITY OF CONNECTING BLOCKS AND MOUNTING HARDWARE BLOCK Features Siemon s high performance block for performance far exceeding proposed category 6 specifications. OPTIONAL VERTICAL CABLE MANAGERS CAN BE MOUNTED BETWEEN TOWERS AND PROVIDE GREATER ACCESS TO CABLES VERTICAL CABLE MANAGEMENT Tower assembly provides pathways for routing protecting cables from entry all the way to the point of termination. OPTIONAL CABLE DUCT AVAILABLE FOR PROVIDING A SINGLE, LARGE PATHWAY AT BASE OF TOWER FOR ROUTING CABLES HORIZONTALLY DESIGNATION LABEL HOLDERS WITH WHITE DESIGNATION STRIPS ARE PROVIDED FOR CIRCUIT IDENTIFICATION ROBUST DESIGN Screws are used to secure wiring bases cable managers to Tower frame. TOWER SYSTEM HIGHLIGHTS The Tower System provides a modular, high-density, cross-connect, cable management system. The towers are available in 192-, 256-, 320-pair sizes. Towers vertical cable managers are completely modular can be vertically stacked to accommodate a higher capacity in a single column. The modular design of the large-scale vertical cable managers allow a technician to easily install a high-density cross-connect system without spending valuable time laying out a termination field. DESIGNATION LABEL SHEETS PAGE 7.3, PATCH PLUGS PAGE 7.9, CABLE ASSEMBLIES PAGE

6 Racks TOWER FIELD TERMINATION KITS MB2-192FT pair, Tower field termination kit height: 406mm (16 in.), width: 216mm (8.50 in.), depth: 152mm (6 in.) MB2-256FT pair, Tower field termination kit height: 541mm (21.31 in.), width: 216mm (8.50 in.), depth: 152mm (6 in.) MB2-320FT pair, Tower field termination kit height: 676mm (26.62 in.), width: 216mm (8.50 in.), depth: 15mm (6 in.) Each kit includes adequate connecting blocks to fully populate Tower LARGE-SCALE VERTICAL CABLE MANAGERS S Large-scale vertical cable manager for use with 192-pair Tower height: 406mm (16 in.), width: 216mm (8.50 in.), depth: 152mm (6 in.) S Large-scale vertical cable manager for use with 256-pair Tower height: 541mm (21.31 in.), width: 216mm (8.50 in.), depth: 152mm (6 in.) S Large-scale vertical cable manager for use with 320-pair Tower height: 676mm (26.62 in.), width: 216mm (8.50 in.), depth: 152mm (6 in.) SMALL-SCALE VERTICAL CABLE MANAGERS M-WM Small-scale vertical cable manager, for use with 192-pair Tower height: 406mm (16 in.), width: 76.2mm (3.0 in.), depth: 152mm (6 in.) M-WM Small-scale vertical cable manager, for use with 256-pair Tower height: 541mm (21.31 in.), width: 76.2mm (3.0 in.), depth: 152mm (6 in.) M-WM Small-scale vertical cable manager, for use with 320-pair Tower height: 676mm (26.62 in.), width: 76.2mm (3.0 in.), depth: 152mm (6 in.) TOWER OPTIONAL ACCESSORIES S188-WD Metal duct for additional horizontal cable management at base of Tower height: 114.3mm (4.50 in.), width: 215.9mm (8.50 in.), depth: 203.2mm (8 in.) S188-GND Ground kit consists of one, 3-position grounding busbar height: 9.0mm (.35 in.), W: 50.8mm (2.0 in.), D: 12.3mm (.49 in.) S188-WD S188-GND 7 5

7 Racks FIELD TERMINATION 19 INCH PANELS FIELD-TERMINATED PANELS ARE AVAILABLE WITH OR WITHOUT / CABLE MANAGERS AND COVERS BLACK ANODIZED PANELS CAN BE MOUNTED DIRECTLY TO A 19 INCH EIA STANDARD RACK OR CABINET COVERS INCLUDED Panels with cable managers include covers to hide cables provide a clean appearance. EASILY ROUTE CABLES Patented cable access openings in base allow cables to be routed from behind the panel directly to the point of termination. EACH PANEL COMES COMPLETE WITH THE APPROPRIATE QUANTITY OF CONNECTING BLOCKS, MOUNTING HARDWARE, AND LABEL HOLDERS WITH WHITE DESIGNATION LABELS FEATURES SIEMON S BLOCKS FOR ULTIMATE PERFORMANCE FAR EXCEEDING CATEGORY 6* SPECIFICATIONS PYRAMID WIRE ENTRY SYSTEM Separates paired conductors when lacing cables to simplify reduce installation time. FIELD-TERMINATED 19 INCH PANELS HIGHLIGHTS panels allow Siemon s wiring blocks to be mounted directly to a 19 inch EIA rack. Panels can be ordered with or without integral cable managers. Use with Siemon st-off brackets (see page 5.8) panels can be mounted to a wall providing 152.4mm (6 in.) of space between the panel mounting surface for cable management. *At the time of this catalog printing, category 6/class E specifications were under development. DESIGNATION LABEL SHEETS PAGE 7.3, 19 INCH CABLE MANAGERS PAGE

8 Racks FIELD-TERMINATED 19 INCH PANELS RMS DB2-64RFT pair, 19 inch field termination kit DB2-128RFT pair, 19 inch field termination kit DB2-192RFT pair, 19 inch field termination kit Note: 1 RMS = 44.5mm (1.75 in.) Each kit includes adequate connecting blocks to fully populate panel. FIELD-TERMINATED 19 INCH PANELS WITH CABLE MANAGERS RMS DB2-64RWM pair, 19 inch field termination kit with cable managers covers DB2-128RWM pair, 19 inch field termination kit with cable managers covers Note: 1 RMS = 44.5mm (1.75 in.) Each kit includes adequate connecting blocks to fully populate panel. VERTICALLY MOUNTED FIELD TERMINATION KITS These 32-pair or 48-pair blocks can be mounted on the same S89B or S89D brackets that hold our blocks. The new, high density 48-pair kit provides category 6 performance in the same footprint as a stard M block. Field-terminated kits include the connecting blocks, designation label label holder. DB1-48FT pair field termination kit on an 89-type retainer.* 4-pair connecting blocks included DB1-32FT pair field termination kit on an 89-type retainer.* 4-pair connecting blocks included *S89 brackets are not included must be ordered separately (see page 9.8). DB1-48FT-89 DB1-32FT

9 Racks PATCH PLUGS ERGONOMIC HANDLE AIDS INSERTION AND REMOVAL OF PATCH PLUG TAPERED LACING DETAILS ENABLE EASY FIELD TERMINATION FIELD INSTALLABLE Siemon is the only company to offer a field installable category 6 patching solution. DIRECTIONAL ARROW PROVIDED TO ASSIST IN PROPER INSERTION ORIENTATION PERFORMANCE The 4-pair plug provides unparalleled performance, with 6.7dB NEXT (typical) 2.2dB NEXT (worst case) at 250 MHz. DURABLE, FLAME-RETARDANT, CLEAR THERMOPLASTIC HOUSING KEEPS CONDUCTORS VISIBLE DURING AND AFTER TERMINATION PATCH PLUGS CAN BE FIELD-TERMINATED TO 23 TO 26 AWG (0.40MM TO 0.51MM) SOLID OR 7-STRAND TWISTED-PAIR CABLE EACH PLUG HOUSING INCLUDES POLARIZATION TO ENSURE PROPER ORIENTATION OF THE PLUG WHEN CONNECTING TO THE CONNECTING BLOCK NEXT Performance for a Siemon Patch Plug mated to a Connecting Block:* (db) Limit Typical Worst Case Margin at 250 MHz Worst Case 2.2 db Typical 6.7 db Frequency (MHz) EASY TERMINATION Simply snap the base cover together to mass terminate all conductors. PATCH PLUG HIGHLIGHTS Siemon technology delivers the world s most advanced connection system. The patch plug utilizes internal pair isolation, pair-to-pair compensation layered contacts to improve crosstalk performance so that the mated plug connecting block far exceed category 6* connecting hardware transmission requirements. The clear housing keeps the conductor colors/positions visible to aid matching termination positions on the other end. *At the time of this catalog printing, category 6/class E specifications were under development. 4-PAIR STRANDED CABLE PAGE

10 PATCH PLUGS P Category 6* compatible, 4-pair, field-terminated, patch plug P pair, field-terminated, patch plug P pair, field-terminated, patch plug TECHNICAL TIP! When to MC6 cable assemblies are configured in the field, The Siemon Company recommends that Siemon MC6 modular cords be purchased (see pages ) cut in half. The cut end of the cord can then be field terminated to the P patch plug while the factory terminated tested modular plug end remains undisturbed. compatible Racks 4-PAIR STRANDED CABLE PAGE 6.7 *At the time of this catalog printing, category 6/class E specifications were under development by TIA/EIA ISO/IEC. CABLE ASSEMBLIES The cable assemblies utilize Siemon s P4 patch plugs for easy reliable connections between termination fields. These assemblies use high performance stred cable which exceeds proposed category 6 specifications are 100% factory transmission tested to ensure performance is compatible with proposed category 6 channel specifications. Colored icons are available for color-coding plugs. P4-P4-(XX) Category 6 compatible, 4-pair, double-ended, stred cable assembly P2-P2-(XX) pair, double-ended, stred cable assembly P1-P1-(XX) pair, double-ended, stred cable assembly compatible Use (XX) to specify cord length: 03 = 0.9m (3 ft.), 05 = 1.5m (5 ft.), 07 = 2.1m (7 ft.), 10 = 3.1m (10 ft.), 15 = 4.6m (15 ft.), 20 = 6.1m (20 ft.), 25 = 7.6m (25 ft.) Custom lengths colors are available upon request. Contact our Customer Service Department for more information. TO MC CABLE ASSEMBLIES The to MC cable assemblies combine Siemon s latest highest performing plugs for patching network equipment to connecting blocks or providing test access to termination fields. The combination of plugs, high performance cable 100% factory transmission testing ensures performance is compatible with proposed category 6 channel specifications. P4A4-(XX)-B(XX) Category 6 compatible, 4-pair, P4 to MC6 stred cable assembly, T568B wiring, white jacket with colored boot P4A4-(XX)-(XX) Category 6 compatible, 4-pair, P4 to MC6 stred cable assembly, T568B wiring, color matching jacket/boot P4T4-(XX)-B(XX) Category 6 compatible, 4-pair, P4 to MC6 stred cable assembly, T568A wiring, white jacket with colored boot P4T4-(XX)-(XX) Category 6 compatible, 4-pair, P4 to MC6 stred cable assembly, T568A wiring, color matching jacket/boot P2E2-(XX)-B(XX) pair, P2 to MC6 stred cable assembly, 10Base-T wiring, white jacket with colored boot P2UT-(XX)-B(XX) pair, P2 to MC6 stred cable assembly, Token Ring wiring, white jacket with colored boot compatible Use 1st (XX) to specify cord length: 03 = 0.9m (3 ft.), 05 = 1.5m (5 ft.), 07 = 2.1m (7 ft.), 10 = 3.1m (10 ft.), 15 = 4.6m (15 ft.), 20 = 6.1m (20 ft.), 25 = 7.6m (25 ft.) Use 2nd (XX) to specify color: 01 = black, 02 = white, 03 = red, 05 = yellow, 06 = blue, 07 = green Custom lengths are available upon request. Contact our Customer Service Department for more information. 7 9