IMEX SLIM IMEX+SPACE B.R. SOLUTION B.R. SOLUTION

Size: px
Start display at page:

Download "IMEX SLIM IMEX+SPACE B.R. SOLUTION B.R. SOLUTION"

Transcription

1 IMEX SLIM IMEX+SPACE B.R. SOLUTION B.R. SOLUTION

2 IMEX+SPACE B.R. SOLUTION IMEX SLIM

3 IMEX+SPACE MINIMALISM ADVANTAGE TEChNICAL ChARACTERISTICS 6MM 13MM ThINNESS LARGE 60CM X 120CM LARgE SIzE STRONG STRONg COMPRESSIvE STRENgTh 900N 13 MM TRADITIONAL TILES 13MM ThINNESS THIN 6MM ThINNESS EASY LOw COST & EASy TRANSPORTATION 01 THIN AND LIGHT develops and manufactures ceramic sheets with a thickness of only 6mm and offers applications for Slim Tiles. 02

4 IMEX+SPACE MINIMALISM IMEX SLIM PRODUCT CATALOg ARTIFICIAL STONE GRANITE MARBLE Combined with traditional ceramic process and emerging technology of IMEX Slim, IMEX Slim has the characteristics of large specifications, thin thickness, light weight, high-hardness and environmental protection. In inherited the rich decorative effect and excellent physical properties of ceramic tiles, IMEX Slim can not only cut down the consumption of natural resources, AMOUSTONE RIVERSTONE GRANITE CALACATTA MALIAN MALISAN MARADO MATINO BRENDA CLUNIA which is in complienced with the concept of ecological and environmental protection, but are also easier to decorate construction and helpful in reducing the weight of the buildings. In the pursuit of lighter and thinner, IMEX Slim using the high quality materials and advanced production technology show the strong material strength, wide range practical performance and superior decoration effect. WSPINTER CLARENCE ONAX CREMARFIL HAZIO MALMA LIGIO ROCKY FABRIC JADESTONE SANDSTONE 04 04

5 AMOUSTONE AMOUSTONE BEIGE PANEL P AMOUSTONE BLUE PANEL P 05 AMOUSTONE Wall: AMOUSTONE GREY PANEL P AMOUSTONE IVORY PANEL P cm Floor: AMOUSTONE IVORY PANEL P cm AMOUSTONE GREY PANEL P AMOUSTONE IVORY PANEL P 06

6 RIVERSTONE RIVERSTONE BEIGE PANEL P RIVERSTONE BEIGE PANEL M 07 RIVERSTONE Wall: RIVERSTONE BEIGE PANEL P cm Floor: RIVERSTONE BEIGE PANEL P cm RIVERSTONE GREY PANEL P RIVERSTONE GREY PANEL M 08

7 GRANITE GRANITE BEIGE PANEL P GRANITE BROWN PANEL P 09 GRANITE Wall: GRANITE GREY PANEL P cm Floor: GRANITE GREY PANEL P cm GRANITE GREY PANEL P 10

8 WSPINTER WSPINTER L GREY PANEL M WSPINTER D GREY PANEL M 11 WSPINTER Wall: WSPINTER L GREY PANEL M cm Floor: WSPINTER D GREY PANEL M cm WSPINTER NATURAL PANEL M WSPINTER ORANGE PANEL M 12

9 CLARENCE ONAX CLARENCE L GREY PANEL P CLARENCE APRICOT PANEL P ONAX BROWN PANEL P CLARENCE BROWN PANEL P CLARENCE Y BROWN PANEL P ONAX GREY PANEL P

10 CALACATTA MALIAN CALACATTA W PANEL P CALACATTA B PANEL P MALIAN IVORY PANEL P MALIAN BLUE PANEL P MALIAN GREY PANEL P

11 MALISAN MARADO MALISAN IVORY PANEL P MALISAN APRICOT PANEL P MARADO D COFFEE PANEL P MALISAN BEIGE PANEL P MALISAN BROWN PANEL P MARADO L COFFEE PANEL P 17 MALISAN B YELLOW PANEL P 18 18

12 MATINO MATINO BEIGE PANEL P. MATINO L GREY PANEL P MATINO Wall: MATINO L GREY PANEL P cm MATINO STONE YELLOW PANEL P MATINO D GREY PANEL P 19 20

13 BRENDA CLUNIA BRENDA IVORY PANEL P BRENDA BEIGE PANEL P CLUNIA L GREY PANEL P CLUNIA M GREY PANEL P BRENDA GREY PANEL P CLUNIA PANEL P

14 CREMARFIL HAZIO CREMARFIL PANEL P HAZIO IVORY PANEL P HAZIO BEIGE PANEL P HAZIO GREY PANEL P

15 MALMA MALMA IVORY PANEL M MALMA BEIGE PANEL M MALMA MALMA GREY PANEL M Wall: MALMA GREY PANEL M cm 25 Floor: MALMA GREY PANEL M cm 26 26

16 LIGIO LIGIO L GREY PANEL M LIGIO M GREY PANEL M LIGIO Wall: LIGIO PANEL M cm LIGIO PANEL M

17 ROCKY ROCKY BEIGE PANEL M ROCKY Wall: ROCKY BEIGE PANEL M cm ROCKY GREY PANEL M 5x80cm ROCKY GREY PANEL M 29 30

18 imex slim advantages - ENERGY SAVING - SPACE SAVING - WEIGHT SAVING - ECONOMIC BENEFITS - EASIER CONSTRUCTION - DURABLE PERFORMANCE - LUXURY DESIGNS Development Construction system Ground installation process STEP ONE : BASE SURFACE TREATMENT STEP TWO: PAVING CONSTRUCTION STEP THREE: FILLING CONSTRUCTION INSTALLATION SPECIFICATION SLIM TILE JOINT GROUT ADHESIVE CEMENT BASE SURFACE 1. The base surface shall not have dust, oil and other substances that affect the adhesion of the adhesive to the base surface. leveling the uneven ground perpendicularity and surface flatness deviation should be less than or equal to 3mm. 2. Paving instruction: Mix the water and the dry powder in the proportion of 1:4, and set aside for 15 minutes,can be used after the secondary mixing ; paste thickness 5-8mm. 3. Filling instruction: The filling shall be carried out after 24 hours of construction. Development Construction system renovation process STEP ONE: CHECK THE BOND STRENGTH OF OLD TILE,MAKE PULL TEST IF NECESSARY STEP TWO: THE OLD TILE SURFACE MUST BE MADE ROUGH WITH AREA MORE THAN 80% STEP THREE: PAVING CONSTRUCTION STEP FOUR: FILLING CONSTRUCTION INSTALLATION SPECIFICATION 1. The base surface shall not have dust, oil and other substances that affect the adhesion of the adhesive to the base surface. Leveling the uneven surface, Perpendicularity and surface flatness deviation should be less than or equal to 3mm. 2. The old tile surface must be made rough with area more than 80%. 3. Paving instruction: Mix the water and the dry powder in the proportion of 1:4, and set aside for 15 minutes,can be used after the secondary mixing ; paste thickness 5-8mm 4. Filling instruction: The filling shall be carried out after 24 hours of construction. CEMENT BASE SURFACE ADHESIVE OLD TILE ADHESIVE JOINT GROUT SLIM TILE ExtErior wall installation process STEP ONE : BASE SURFACE TREATMENT STEP TWO: PAVING CONSTRUCTION STEP THREE: FILLING CONSTRUCTION CEMENT BASE SURFACE ADHESIVE SLIM TILE JOINT GROUT interior wall installation process STEP ONE : BASE SURFACE TREATMENT STEP TWO: COATING WATERPROOF MATERIAL STEP TWO: PAVING CONSTRUCTION CEMENT BASE SURFACE WATERPROOF COATING ADHESIVE JOINT GROUT SLIM TILE STEP THREE: FILLING CONSTRUCTION INSTALLATION SPECIFICATION 1. The base surface shall not have dust, oil and other substances that affect the adhesion of the adhesive to the base. surface leveling the uneven surface, Perpendicularity and surface flatness deviation should be less than or equal to 3mm. 2. Paving instruction: Mix the water and the dry powder in the proportion of 1:4, and set aside for 15 minutes,can be used after the secondary mixing ; paste thickness 5-8mm. 3. Filling instruction: The filling shall be carried out after 24 hours of construction. INSTALLATION SPECIFICATION 1. The base surface shall not have dust, oil and other substances that affect the adhesion of the adhesive to the base surface Leveling the uneven surface Perpendicularity and surface flatness deviation should be less than or equal to 3MM. 2. Waterproofing: coat two times, thickness 0.5mm each time. 4-8hours interval till the surade is dry. 3. Paving instruction: Mix the water and the dry powder in the proportion of 1:4, and set aside for 15 minutes,can be used after the secondary mixing ; paste thickness 5-8mm. 4. Filling instruction: The filling shall be carried out after 24 hours of construction

19 IMEX Slim Technical Parameters type of product : imex +space slim size : 600x1200MM thickness : 5.5MM Group : Bia PROPERTIES TEST METHOD REQUIREMENTS ISO RESULTS VERDICTS "Length The deviation, in percent, of the average size for each tile(2 or 4 ±0.5% 0.00 ~ P sides) from the work size " "Width ISO The deviation, in percent, of the average size for each tile(2 or 4 ±0.5% ~ P sides) from the work size " "Thickness The deviation, in percent,of the average thickness of each tile from the work size thickness " ISO ±5% +0.4 ~ +2.5 P "Surface quality A minimum of 95% of the tiles shall be free from visible defects that would impair A minimum of 95% of the tiles shall be free from visible defects that ISO the appearance of a major area of tiles would impair the appearance of a major area of tiles" Pass P Water absorption ISO "Average: 0.5% "0.1% Individual max: 0.6%" 0.1%" P Breaking strength ISO "Thickness <7.5mm Not less than 700N" "Average 736N " P Modulus of rupture ISO "Min 35MPa "Average 40MPa Individual min 32MPa" Minimum 38Mpa" P Abrasion resistance ISO Resistance to surface abrasion of glazed tiles intended for use on floors: Report the "Abrasion class: 3 abrasion class and cycles passed Failure visible at revolutions:1500" P Thermal shock resistance ISO Test method available "No defect was found after being tested " P Crazing resistance ISO Required "No defect was found after being tested " P Frost resistance ISO Required "No defect was found after being tested " P Resistance to staining ISO For galzed tiles, Minimum Class 3 "Class 5 " P Resistance to low concentration of acids and alkalis:manufacturer to state classification Class GLA P Resistance to chemicals ISO Resistance to high concentration of acids and alkalis:test method available Class GHA P Resistance to household chemicals and swimming pool salts: Minimum class B "Class GA " P 33 34

20 B.R. SOLUTION IMEX+SPACE B.R. SOLUTION