ADDENDUM #1 NWIT#16-32 Sewer Separation Program New Westminster, BC

Size: px
Start display at page:

Download "ADDENDUM #1 NWIT#16-32 Sewer Separation Program New Westminster, BC"

Transcription

1 August 29, 2016 ADDENDUM #1 NWIT#16-32 Sewer Separation Program New Westminster, BC This addendum modifies the Invitation to Tender only as noted: Please refer to Addendum No. 1 from Opus DaytonKnight Consultants Ltd (6 pages following) Please acknowledge this addendum as indication in the Form of Tender. END OF ADDENDUM #1 Yours truly, Roy Moulder, SCMP Purchasing Manager Draft Addendum #1

2 CORPORATION OF THE CITY OF NEW WESTMINSTER CONTRACT No. NWIT SEWER SEPARATION PROGRAM ADDENDUM No. 1 (6 pages) This Addendum shall form part of the Contract No. NWIT A. Form of Tender: Schedule of Quantities and Prices Payment items A1 and A2 have been amended. New payment item A12 added to Section A- Storm Pipe. Payment item B2 has been amended. Replace FT-Page 4-5 with attached. NOTE 1: For Storm Pipe 375 mm diameter or greater, HDPE is allowed. NOTE 2: Payment item A12 has been added for the 200 mm storm service connection on Quebec Street. NOTE 3: All Fibre Optic Pull Boxes to be SYNERTECH , as per the attached product sheet. B. Supplementary Specifications Section S Communication and Fibre Optic Conduits Replace: 2.2 Plastic Junction Boxes.1 Plastic junction boxes to conform to the City Supplementary Standard Drawing SD-C.2. With: 2.2 Junction Boxes.1 Junction boxes shall be SYNERTECH 2436 Polymer Concrete Boxes with 36 depth. Page 1

3 Attach this Addendum to the Contract Documents. Date: August 24, 2016 Addendum No. 1 received. Signature of Tenderer Name of Tenderer (please print) Encl. - FT Page SYNERTECH 2436 Product Sheet OPUS DAYTONKNIGHT CONSULTANTS LTD. CITY OF NEW WESTMINSTER # Harbourside Drive 511 Royal Avenue North Vancouver, B.C. New Westminster, B.C. V7P 3S1 V3L 1H9 Page 2

4 (Addendum No. 1) FT PAGE 4 FORM OF TENDER Appendix 1 SCHEDULE OF QUANTITIES AND PRICES (See paragraph of the Instructions to Tenderers - Part II) (All prices and Quotations including the Contract Price shall include all Taxes, but shall not include GST. GST shall be shown separately.) ITEM NO. MMCD REF. Section A Storm Pipe A1 A2 A3 DESCRIPTION UNIT QUANTITY Storm Pipe 450 mm dia. DR PVC or HDPE, imported backfill Park Row First Street Between Vancouver Street & College Crt. Storm Pipe 375 mm dia. DR PVC or HDPE, imported backfill. First Street Between College Crt & Emory Street Storm Pipe 250 mm dia. DR PVC, imported backfill. First Street Between Emory Street & St. Patrick Street College Crt. Emory Street Arbutus Street Fourth Avenue Oakland Street Queens Avenue Third Avenue Quebec Street Gloucester Street Blackie Street UNIT PRICE AMOUNT Tenderer s Initials MMCD 2009 Edition Reference No. NWIT-16-32

5 ITEM NO. A4 A5 A6 A7 A8 MMCD REF DESCRIPTION UNIT QUANTITY Tie-in 250mm dia. to existing manhole (Park Row) Tie-in 250mm dia. to existing stub (Gloucester St. at Ash St. & Quebec St. at Eleventh St.) Service Connection 100mm dia. Service Connection 150mm dia S Manhole base, lid, slab, cover and frame 1050 mm dia. A S Manhole riser 1050 mm dia. A10 Catchbasin top inlet Std. Dwg S11. A11 Catchbasin lead mm diam., all lengths. A Service Connection 200mm dia. Subtotal (Item A1 to A12) Plus GST (5%) TOTAL AMOUNT OF SECTION A Section B Fibre Optic Conduit B1 B S Fibre Optic Conduit 100 mm dia. Park Row First Street Between Vancouver Street & Third Avenue S Fibre Optic Pull Box SYNERTECH Subtotal (Item B1 to B2) Plus GST (5%) TOTAL AMOUNT OF SECTION B Section C Optional Items Each 1 Each Each 28 Vert. 58 Each 30 Each Each 6 C S Mill and Overlay Mobilization & Demobilization Each 2 C S Square Mill and overlay 35 mm depth C Cubic Rock Removal Subtotal (Item C1 to C3) Plus GST (5%) TOTAL AMOUNT OF SECTION C (Addendum No. 1) FT PAGE 5 UNIT PRICE AMOUNT Tenderer s Initials MMCD 2009 Edition Reference No. NWIT-16-32

6 Electric & Communications 2436 COVER: Style: Material: Model: Weight: Std. Fasteners: Options: Surface: Coefficient of Friction: Performance: Flush Solid DuoMold Composite 24 x lbs 1/2-13 Stainless Steel Hex Head Bolt, Self-Locating Insert Logos and Special Markings Slip Resistant & Marked* >0.6 ASTM 1028 ANSI/SCTE-77 Tier 22, WUC 3.6, ASTM C857 A-16 BODY: Material: Model: Weight: Wall Type: Performance: DuoMold Composite 24 x Depth: 82 lbs 24 Depth: 92 lbs 36 Depth: 110 lbs Straight ANSI/SCTE-77 Tier 22, WUC 3.6, ASTM C857 A-16 Bodies are stackable** to Depths of: 36, 42, 48, 60, 72 A B C D E F G /8 26-1/ /2 35-1/4 29-1/8 17-1/ /8 26-1/ /2 35-1/4 29-1/8 17-1/ /8 26-1/ /2 35-1/4 29-1/8 17-1/2 Heavy Duty: Incidental, Non-deliberate Traffic For use in non-vehicular traffic situations only. * Cover comes standard with permanent markings for manufacturer, load rating, model size and manufacturing location. Contact your Oldcastle Enclosure Solutions Distribution Center for specific information and additional options. Actual load rating is determined by the box and cover combination. Weights and dimensions may vary slightly **Stacked body units are currently not rated. oldcastleprecast.com/enclosuresolutions Revision 9/ Oldcastle, Inc.

7 Electric & Communications Options: Available DuoMold Composite Covers: Flush Solid (Standard) 2436 Fastener Options for DuoMold Composite Covers: Hex Head Bolt (Standard) Penta Head Bolt Oldcastle Enclosures Vandal Resistant Bolt Add on Options: Larger Lift Hook Pocket EMS Marker (E) Mouseholes/Knockouts Rack Mount (A) Cable Racks/Cable Arms (B) Unistrut (C) Pulling Eye - 1,000 lb and 3,000 lb (D) Ground Buss (F) Dividers Racking Provision Lid Gaskets* Solid Bottom Bodies are Stackable (with tallest body on bottom) Composite Cover Hex Head Penta Head Vandal Resistant *Lid Gaskets inhibit water flow into the box, they do not make Enclosure fully waterproof. A B C D E F Raw Material Specifications: Standard Test Method Properties of Raw Material ASTM Designation Typical Value Compressive Strength of Polymer Concretes Compressive Strength C 469 > 17,000 psi Flexural Properties of Plastic Materials Flexural Strength D 790 > 14,000 psi Resistance of Plastics to Chemical Reagents Chemical Resistance Retain > 75% of original strength Impact Resistance by Means of a Falling Weight Impact Resistance D 2444 > 70 ft-lb Static Coefficient of Friction Friction Coefficient C 1028 > 0.6 ASTM Specifications shall be the current revision Test Reports available on request The Rural Utility Service (RUS) is a department of the US Department of Agriculture organized to facilitate rural developments. You will fi nd Oldcastle Enclosure Solutions brand enclosures listed by the RUS. All Oldcastle Enclosure Solutions brand enclosures conform to the RUS Tamper Resistant fastener design for buried pedestals. Product Load Rating: Note: Heavy Duty : Incidental, Non-deliberate Traffic For use in non-vehicular traffic situations only. Actual load rating is determined by the box and cover combination. Weights and dimensions may vary slightly All information contained on this sheet is current at the time of printing. Oldcastle Precast, Inc. reserves the right to discontinue or update product information without notice. oldcastleprecast.com/enclosuresolutions Revision 9/ Oldcastle, Inc.