LEE COUNTY BOARD OF COUNTY COMMISSIONERS PUBLIC WORKS ADMINISTRATION DEPARTMENT OF TRANSPORTATION CONTRACT PLANS PLANS OF PROPOSED

Size: px
Start display at page:

Download "LEE COUNTY BOARD OF COUNTY COMMISSIONERS PUBLIC WORKS ADMINISTRATION DEPARTMENT OF TRANSPORTATION CONTRACT PLANS PLANS OF PROPOSED"

Transcription

1 LEE COUNTY BOARD OF COUNTY COMMISSIONERS PUBLIC WORKS ADMINISTRATION 10 CHIPLEY 95 PENSACOLA FORT WALTON BEACH TALLAHASSEE 10 LAKE 295 JACKSONVILLE CONTRACT PLANS PANAMA CITY CITY GAINESVILLE ST AUGUSTINE INDEX OF LIGHTING PLANS PLANS OF PROPOSED OCALA DELAND 4 DAYTONA BEACH L-1 KEY L-2 TABULATION OF QUANTITIES L-3 GENERAL NOTES L-4 POLE DATA AND LEGEND L-5 - L-7 LIGHTING PLAN L-8 SERVICE POINT/LOAD CENTER DETAIL L-9 POLE DETAIL GOVERNING DESIGN STANDARDS: Florida Department of Transportation, FY Standard Plans for Road and Bridge Construction and applicable Interim Revisions (IRs) Standard Plans for Road Construction and associated IRs are available at the following website: GOVERNING STANDARD SPECIFICATIONS: Florida Department of Transportation, July 2018 Standard Specifications LITTLETON / KISMET REALIGNMENT COUNTY PROJECT LIGHTING PLANS LOCATION OF PROJECT NEW PORT RICHEY TAMPA ST PETERSBURG 2 SARASOTA - BRADENTON ORLANDO 4 LAKELAND BARTOW NAPLES EXPRESSWAY TURNPIKE FT MYERS KEY WEST 60% PLANS IN PROGRESS LIGHTING PLANS BEACH LINE FLORIDA'S ENGINEER OF RECORD: VINCENT J. MILLER, P.E. MELBOURNE - COCOA 95 FT PIERCE WEST PALM BEACH FT LAUDERDALE MIAMI P.E. No.: CORPORATE LAKE DRIVE, SUITE 150 TAMPA, FL CONTRACT No.: C-9E24 VENDOR No.: CERTIFICATE OF AUTHORIZATION No.: 5564 LEE COUNTY PROJECT MANAGER: THE OFFICIAL RECORD OF THIS IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G , F.A.C. for Road and Bridge Construction at the following website: L-1 3:50:42 PM S:\CF_TOPS\06xxxx - AIM-LeeCo Littleton-Kismet\Project Working\Plans\lighting\KEYSLT01.DGN

2 TABULATION OF QUANTITIES PAY ITEM CONDUIT, FURNISH & INSTALL, OPEN TRENCH LF UNIT L-5 L-6 L-7 NUMBERS TOTAL THIS GRAND TOTAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL CONDUIT, FURNISH & INSTALL, DIRECTIONAL BORE LF PULL & SPLICE BOX, F&I, 13" x 24" COVER SIZE EA LIGHTING CONDUCTORS, F&I, INSULATED, 8-6 LF LIGHTING CONDUCTORS, F&I, INSULATED, NO 4-2 LF LIGHT POLE COMPLETE, FURNISH & INSTALL STANDARD POLE STANDARD FOUNDATION, 35' MOUNTING HEIGHT EA LUMINAIRE & BRACKET ARM- ALUMINUM, FURNISH & INSTALL NEW LUMINAIRE AND ARM ON NEW/EXISTING POLE EA LOAD CENTER, F&I, SECONDARY VOLTAGE EA POLE CABLE DISTRIBUTION SYSTEM, CONVENTIONAL EA P.E. : ROAD COUNTY FINANCIAL PROJECT ID TABULATION OF QUANTITIES L-2 3:50:46 PM S:\CF_TOPS\06xxxx - AIM-LeeCo Littleton-Kismet\Project Working\Plans\lighting\TABQLT01.DGN

3 GENERAL NOTES 1) BEFORE ANY PROJECT WORK BEGINS THERE SHALL BE A MAINTENANCE TRANSFER. THE MAINTENANCE WILL TRANSFER FROM LEE COUNTY DOT/TRAFFIC TO AN FDOT QUALIFIED ELECTRICAL CONTRACTOR NO LATER THAN THE DAY BEFORE THE PROJECT BEGINS. THE CONTRACTOR IS REQUIRED TO HAVE AN AUTHORIZED REPRESENTATIVE ONSITE TO ACCEPT THE MAINTENANCE TRANSFER AND TO WITNESS THE EXISTING CONDITION OF THE STREET LIGHTING SYSTEM. 2) ANY DEFICIENCIES THAT MAY BE FOUND ON THE DAY OF THE MAINTENANCE TRANSFER SHALL BE REPAIRED BY LEE COUNTY TRAFFIC AT THAT TIME. AFTER ANY DEFICIENCIES HAVE BEEN CORRECTED ON THE DAY OF THE TRANSFER, ANY AND ALL DEFICIENCIES FOUND FROM THAT DAY AND TIME SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 3) CONTRACTOR MAINTENANCE RESPONSIBILITIES: CONTRACTOR SHALL PROVIDE 24- HOUR CONTACT PERSON(S), TELEPHONE NUMBERS AND ADDRESSES AT THE TIME OF TRANSFER. FAILURE TO RESPOND TO MAINTENANCE RESPONSIBILITIES IN A TIMELY MANNER WILL TRIGGER A VENDOR/CONTRACTOR COMPLAINT NOTICE TO LEE COUNTY CONTRACTS AS WELL AS FDOT. TIMELY MANNER IN RESPONSE TO MAINTENANCE RESPONSIBILITIES IS DEFINED AS RESPONSE TO SITE NO LATER THAN TWO (2) HOURS AFTER NOTIFICATION. IN THE EVENT THAT LEE COUNTY FORCES ARE CALLED OUT TO RESPOND, THE CONTRACTOR WILL BE BILLED THE ENTIRE COST AS A DEDUCT ON THE NEXT PAYMENT REQUEST. BEING AN OUT OF TOWN CONTRACTOR DOES NOT RELIEVE THIS RESPONSIBILITY. 4) LOCATES: ONE (1) COURTESY LOCATE SHALL BE PERFORMED BY LEE COUNTY SIGNALS AT THE START OF THE PROJECT AT THE CONTRACTOR S REQUEST. THE CONTRACTOR SHALL DOCUMENT THE LOCATION OF THE EXISTING UNDERGROUND AND ABOVE GROUND FACILITIES. AFTER THE COURTESY LOCATE, ALL LOCATES WITHIN THE PROJECT LIMITS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE PERFORMED IN A TIMELY MANNER. TIMELY MANNER IN RESPONSE TO LOCATES IS DEFINED AS LOCATE SHALL BE PERFORMED NO LATER THAN TWENTYFOUR (24) HOURS AFTER NOTIFICATION OR AS REQUIRED BY FLORIDA STATUTE. LEE COUNTY SIGNALS WILL ADVISE THE CONTRACTOR VIA OR FAX OF SUNSHINE LOCATE REQUESTS WITHIN THE WORK ZONE. ANY DAMAGE INCURRED DUE TO CONTRACTOR FAILURE TO LOCATE SHALL BE REPAIRED BY THE CONTRACTOR. SHOULD LEE COUNTY FORCES BE CALLED OUT TO MAKE REPAIRS DUE TO CONTRACTOR REFUSAL OR INABILITY TO MAKE REPAIRS, THE CONTRACTOR WILL BE BILLED THE ENTIRE COST AS A DEDUCT ON THE NEXT PAYMENT REQUEST AND WILL TRIGGER A VENDOR/CONTRACTOR COMPLAINT NOTICE TO BE FILED WITH LEE COUNTY CONTRACTS AS WELL AS FDOT. BEING AN OUT OF TOWN CONTRACTOR DOES NOT RELIEVE THIS RESPONSIBILITY. 5) DAMAGE TO EXISTING FACILITIES: ANY DAMAGE TO LEE COUNTY FACILITIES SHALL BE REPAIRED BY THE CONTRACTOR. REPAIRS SHALL BE MADE TO ENSURE FACILITIES ARE LIKE NEW OR BETTER. ANY DAMAGE TO EXISTING COMMUNICATION LINES SHALL NECESSITATE THE REMOVAL OF ALL DAMAGED LINES AND THE REPULLING OF NEW CABLE. SPLICING OF COMMUNICATION LINES WILL NOT BE ALLOWED. CAUTION SHALL BE EXERCISED DURING EXCAVATION NEAR EXISTING LEE COUNTY FIBER OPTIC LINES, SINCE MANY ENTITIES USE THESE FACILITIES. SHOULD DAMAGE OCCUR TO FIBER OPTIC LINES, LEE COUNTY WILL DECIDE WHICH QUALIFIED FIBER OPTIC SPLICING COMPANY WILL BE USED TO MAKE REPAIRS. CONTRACTOR WILL BE RESPONSIBLE FOR ALL REPAIR COSTS INCURRED, WHETHER REPAIRS ARE MADE BY LEE COUNTY OR A THIRD PARTY. 6) EXISTING EQUIPMENT: SHALL BE RETURNED TO LEE COUNTY DOT/TRAFFIC IN GOOD OPERATING CONDITION AND IN THE SAME CONDITION AS ON THE DAY OF THE MAINTENANCE TRANSFER AT 5650 ENTERPRISE PARKWAY, FORT MYERS, FL IN A TIMELY MANNER. TIMELY MANNER FOR EXISTING EQUIPMENT IS DEFINED AS NO LATER THAN 72 HOURS AFTER DISCONNECTION. THE CONTRACTOR SHALL NOTIFY LEE COUNTY OF THE DISCONNECTION 24 HOURS IN ADVANCE TO SCHEDULE THE DELIVERY OF THE EQUIPMENT SO THAT DELIVERY TAKES PLACE DURING A REGULAR BUSINESS DAY AND HOURS. FAILURE TO PERFORM AS OUTLINED IN THIS PARAGRAPH WILL RESULT IN NO INSPECTION AT COMPLETION UNTIL CONTRACTOR IS IN COMPLIANCE WITH THIS REQUIREMENT. LEE COUNTY SIGNALS WILL WITHHOLD PAYMENT REQUESTS UNTIL LEE COUNTY PROPERTY IS DELIVERED TO 5650 ENTERPRISE PARKWAY, FORT MYERS, FL ) TWENTY-FOUR (24) HOUR NOTICE IS REQUIRED TO THE INSPECTOR SHOWN IN THE PLAN SET GENERAL NOTES. SHOULD THE INFORMATION BE MISSING, THE CONTRACTOR IS HEREBY DIRECTED TO CALL LEE COUNTY SIGNALS AT AND ASK FOR THE SIGNAL INSPECTION DEPARTMENT. P.E. : ROAD COUNTY FINANCIAL PROJECT ID GENERAL NOTES L-3 3:50:48 PM S:\CF_TOPS\06xxxx - AIM-LeeCo Littleton-Kismet\Project Working\Plans\lighting\GNNTLT01.DGN

4 CONVENTIONAL POLE DATA LIGHTING DESIGN CRITERIA POLE CIRCUIT STATION DIST. OR ARM LUMINAIRE WATTAGE MOUNTING HEIGHT POLE SETBACK PAY ITEM OPTION Average Initial Horizontal Intensity 3.0 Foot Candles 1 A ' ' 4' FROM EOP 2 3 A-1 A ' 8.0' ' 30' 17' FROM EOP 10' FROM EOP NEW NEW 4-EXT UNK NA 8.0' 149 TBD NA RETRO Average Initial Vertical Intensity Uniformity Ratio Avg./Min. Max./Min. Wind Speed 2.3 Foot Candles 4:1 Or Less 10:1 Or Less 170 MPH 1 A ' ' 16' FROM EOP NEW 2 A ' ' 18' FROM EOP NEW 3 A ' ' 24' FROM EOP 4 5 A ' ' 24' FROM EOP A ' ' 18' FROM EOP LEGEND 6 7 A ' ' 18' FROM EOP A ' ' 10' FROM EOP SYMBOLS 8 9 A ' ' 20' FROM EOP A ' ' 19' FROM EOP Single arm conventional LED luminaire. Designed for Type distribution. Luminaire wired for volt operation. Pole mounting height ft. Use curve or equal. Single arm conventional LED luminaire. Designed for Type distribution. Luminaire wired for volt operation. Pole mounting height ft. Use curve or equal. Schedule 40 PVC conduit with THW or THWN conductors inside (conduit and conductor size as shown on plan sheets). Run one (1) 6 AWG copper bond conductor (TW green insulation) inside conduit with other conductors. Galvanized metal conduit with THW or THWN conductors inside (conduit and conductor size as shown on plan sheets). Pull box. For specifications see Section 635 of Standard Specifications For Road And Bridge Construction. Distribution point. For requirements see Index No. 104 of Design Standards. P.E. : ROAD COUNTY COUNTY PROJECT NO POLE DATA AND LEGEND L-4 9/28/ :12:06 PM S:\CF_TOPS\06xxxx - AIM-LeeCo Littleton-Kismet\Project Working\Plans\lighting\PLDTLT01.DGN

5 SAN WATER WATER WATER NE 24TH AVE NE 24TH AVE SAN SAN KISMET PKWY E POT STA STA CKT A-1-1 RETROFIT EXISTING CONCRETE LIGHT POLE POT STA STA CKT A-1-2 OLD LITTLETON RD PC STA STA CKT A-1-4 LITTLETON RD 0 10 N Feet 50 MATCH LINE A, SEE? P.E. : ROAD COUNTY COUNTY PROJECT NO LIGHTING PLAN L-5 3:51:48 PM S:\CF_TOPS\06xxxx - AIM-LeeCo Littleton-Kismet\Project Working\Plans\lighting\PLANLT01.DGN

6 N OLD LITTLETON RD 0 10 Feet 50 MATCH LINE A, SEE? STA LOAD CENTER EXISTING SERIVCE POINT LITTLETON RD PI STA MATCH LINE B, SEE? PI STA P.E. : ROAD COUNTY COUNTY PROJECT NO LIGHTING PLAN L-6 3:51:56 PM S:\CF_TOPS\06xxxx - AIM-LeeCo Littleton-Kismet\Project Working\Plans\lighting\PLANLT02.DGN

7 POT STA PI STA PT STA STA CKT A-2-2 STA CKT A-2-3 STA CKT A-2-4 N OLD LITTLETON RD LITTLETON RD 0 10 Feet 50 MATCH LINE B, SEE? LITTLETON RD STA CKT A-2-1 PRC STA PRC STA STA CKT A-2-5 POT STA PI STA STA CKT A-2-6 STA CKT A STA CKT A-2-8 PT STA CORBETT RD STA CKT A PI STA P.E. : ROAD COUNTY COUNTY PROJECT NO LIGHTING PLAN L-7 3:51:57 PM S:\CF_TOPS\06xxxx - AIM-LeeCo Littleton-Kismet\Project Working\Plans\lighting\PLANLT03.DGN

8 PHOTOCELL RATED FOR 480V 100 AMP, 480V 3 POLE S/N CONCRETE POLE PRESTRESS TYPE P-II, 16'-0" LONG (SEE NOTE 9) F.P.L. PHOTOCELL SHALL BE PROVIDED, WIRED SERVICE AND INSTALLED BY THE MANUFACTURER 480V TO GROUND N H COMBINATION LIGHTING CONTACTOR AND DISCONNECT SWITCH RATED FOR SERVICE ENTRANCE IN NEMA 4X ENCLOSURE, LABEL MUST BE FACTORY INSTALL MANUFACTURED BY SQUARE-D (SHORT VERSION) OR SIEMENS INDUSTRY INC. OR APPROVED EQUAL DISTRIBUTION LINE PHOTOCELL RATED FOR 480V SERVICE LOAD CENTER 100 AMPS,480V 3 POLE AND S/N HEAVY DUTY SAFETY SWITCH IN NEMA 4X ENCLOSURE W/40 AMP FUSE H O A KEY OPERATED SWITCH LIGHTNING PROTECTOR RATED FOR SERVICE ENTRANCE WITH CONTACTOR AND PHOTOCELL NIGHT MASTER AS MANUFACTURED BY SQUARE D. OR SIEMENS INDUSTRY INC. OR APPROVED EQUAL. F.P.L. TRANSFORMER 480V, 1 PHASE 2W LIGHTNING PROTECTOR TERMINATE CONDUIT WITH INSULATED GROUNDING BUSHING WITH SOLDERLESS LUGS F.P.L. POLE 40 AMPS FUSE (TYPE RK5) COPPER NEUTRAL BUS #6 AWG INSULATED COPPER GROUND WIRE IN 3 4" / RIGID GALVANIZED STEEL CONDUIT. AT TOP OF POLE THE GROUNDING PIG TAIL MUST BE DETACHED COPPER GROUND BUS LIGHTING CONTACTOR 4 POLES RATED FOR 480V AND 100 AMPS BRANCH CKT'S IN 2" RIGID GALVANIZED STEEL COND. (FOR NUMBER OF BRANCH CKT'S REFER TO PLAN) CABLE & PVC U-GUARD AND BOOT BY F.P.L. CONDUIT CLAMP (TYP.) PULL BOX (27-1/2" X 18" X 12") COVER MARKED "ELECTRIC" 8'-0" 2#2 IN 2" RIGID GALVANIZED STEEL COND. EXIST. BARE WIRE #6 INHERENT TO THE POLE AT BOTTOM THE GRD. (PIG TAIL) TO CIRCUIT #1 CIRCUIT #2 SPARE PULL BOX (MARKED STREET LIGHTING) BE CONNECTED TO THE GROUND ROD TERMINATE RIGID STEEL CONDUIT AT PULL BOX CONCRETE EXOTHERMICAL THERMOWELD CONNECTION 6" MIN. COND. STUPUP PULL BOX (27-1/2" X 18" X 12") COVER MARKED "STREET LIGHTING" CONCRETE 6'-0" 1'' BED OF CRUSHED STONE FOR DRAINAGE. 12" 30" MIN. WIRING DIAGRAM 3" WARNING TAPE 5 8" / DIA. X 20' GRD. ROD DPX CONNECTION BY F.P.L. N.T.S 5 / 8" DIA. X 20' GRD. ROD 6'-0" 1#6 GRD. IN 3/4" PVC CONDUIT BRANCH CKT'S AND 1#6 GRD. IN 2" PVC CONDUIT TO LIGHT POLE TRANSITION FITTING FROM RIGID STEEL TO PVC AFTER 90 RIGID STEEL ELBOW 2#2 IN 2" PVC CONDUIT. (SEE NOTE 8 TYP.) NOTES: SERVICE POINT DETAIL N.T.S 1. THE ENCLOSURE SHALL BE NEMA 4X (STAINLESS STEEL), POLE MOUNTED, RIGIDLY ATTACHED TO THE POLE FACE. 2. THE ENCLOSURE DOOR SHALL BE SECURED BY LOCKABLE LATCH. SERVICE ENTRANCE PANEL 3. A 600V LIGHTNING PROTECTOR SHALL BE WIRED INSIDE THE ENCLOSURE. NO SPLICING IN ENCLOSURE. 4. ALL SERVICE EQUIPMENT SHALL BE U.L. APPROVED. 5. CONTRACTOR SHALL COORDINATE WITH F.P.L. ENGINEERS FOR THE INSTALLATION OF THE F.P.L. RISER WHICH INCLUDES A CONNECTION FEE OF $ (THIS FEE SHALL BE INCLUDED IN BID ITEM ) THIS LAYOUT HAVE BEEN APPROVED BY THE MAINTENANCE AGENCY (MIAMI-DADE COUNTY). 11. LIGHTNING PROTECTOR TO BE WIRED ON LOAD SIDE OF DISCONNECT SWITCH. 6. ALL GROUND ROD SHALL BE INTERCONNECTED (USING #6 GROUND WIRE). 7. PROVIDE SUPPLEMENTARY GROUND ELECTRODE SPACE AT LEAST 6FT. 8. ALL CONDUCTOR SHALL BE TYPE THWN-2. (OTHER TYPE OF CONDUCTOR IS NOT ALLOWED. EXCEPT GROUND WIRE WHICH SHALL BE TYPE THWN.) 9. CONTRACTOR SHALL SUBMIT STRUCTURAL CALCULATIONS OF THE POLE, SIGNED AND SEALED BY A PROFESSIONAL ENGINEER. 10. CONTRACTOR SHALL COORDINATE WITH F.P.L. ENGINEERS FOR THE INSTALLATION OF THE F.P.L. RISER WHICH INCLUDES A CONNECTION FEE OF DOLLARS. (THIS FEE SHALL BE INCLUDED IN BID ITEM ) THIS LAYOUT HAVE BEEN APPROVED BY THE MAINTENANCE AGENCY (MIAMI-DADE COUNTY AND F.D.O.T. DISTRICT SIX) *NOTE TO DESIGNER: TO BE USED FOR 2 CIRCUITS ONLY. P.E. : ROAD COUNTY COUNTY PROJECT NO SERVICE POINT/ LOAD CENTER DETAIL L-8 3:52:00 PM S:\CF_TOPS\06xxxx - AIM-LeeCo Littleton-Kismet\Project Working\Plans\lighting\SRPTLT01.DGN

9 DANGER DO NOT TAMPER HIGH VOLTAGE 8' BRACKET ARM EXTRUDED ARM CLAMPS TRUSS ARM (RISE ARM SHALL BE NO MORE THAN 5 FEET) TAPERED ALUMINUM POLE 30' OR 35' LUMINAIRE CABLE SOWA 14/3 CONDUCTOR INTERNAL GROUND LUG MOLDED PLUG AND CONNECTOR (ORANGE) POWER CABLE CABLE STRAIN RELIEF GROUND WIRE CONCRETE SIDEWALK INTERNAL GROUND LUG OR OPPOSITE DOOR WALL POWER CABLE IN 2" COND. TRANSFORMER BASE GALV. STEEL ANCHOR BOLTS WITH NUTS AND WASHERS 1-#6 GRD. WIRE IN 1/2" CONDUIT P.V.C. COUPLER 6" MIN. POLE DETAIL N.T.S. FOR ADDITIONAL DETAILS SEE INDEX 100 DISTRIBUTION BLOCK (RED) WITH 10 AMP. FNQ TYPE FUSE SURGE ARRESTOR MOLDED PLUG AND CONNECTOR (RED) THERMOWELD (EXOTHERMIC CONNECTION) 27 1/2" x 18" x 12" PULL BOX 12" BED OF PEAROCK OR CRUSHED STONE FOR DRAINAGE 5/8" DIA. 10" LONG GRD. ROD P.E. : ROAD COUNTY COUNTY PROJECT NO LUMINAIRE DETAIL L-9 3:52:12 PM S:\CF_TOPS\06xxxx - AIM-LeeCo Littleton-Kismet\Project Working\Plans\lighting\CNPLLT01.DGN