1 PROVIDE SEPARATION (ROOF UNDERLAY) UNDER METAL CAPPING AND 9mm MIN.H3 PLY - PACKED TO A FALL 5 PRE FINISHED METAL CAPPING TO PARAPET WITH 5 MIN.FALL Z Z REFER TABLE 7 - E2/AS1 CARRY MESH/RENDER UP TO TOP EDGE CONTINUOUS OVER TOP OF WALL FRAME 20mm DRAINED CAVITY RENDER SYSTEM 1. INSTALL METAL SADDLE FLASHING AT WALL JUNCTION 2. ENSURE TOP IS TEMPORARILY WATERPROOFED BEFORE COMMENCING RENDERING 3. METAL CAPPING EXCLUDING DRIP EDGE MUST OVERLAP SHEET BY 50mm MIN. IN LOW, MED or HIGH WIND ZONE, 70mm MIN. IN VERY HIGH, 90mm MIN. IN EXTRA HIGH WIND ZONES SYSTEM PARAPET/METAL FLASHING DETAIL PP 500

2 10 H3.1 CAPPING PLATE CUT TO 10 SLOPE WITH FLASHING TAPE OR ROOFING UNDERLAY CAP AT 10 OVERSEATS WALLS, GLUE TO WALL CLADDING STO PREMESHED upvc ADJUSTABLE CORNERS OVERLAY OF STO FLEXYL MEMBRANE UNDER MESH COAT TO TOP & SIDES, 100mm MIN.DOWNTURN OVER BASE COAT CONTINUOUS OVER TOP OF WALL FRAME 20mm DRAINED CAVITY RENDER SYSTEM NOTE: STOFLEXYL MESHED WATERPROOFING MEMBRANE HAS BEEN TESTED BY BRANZ TO MEET THE REQUIREMENTS OF AS/NZS4858 WATERPROOF MEMBRANE AS REQUIRED BY E2/AS1 EXTRA HIGH WIND ZONES REQUIRE A RIGID UNDERLAY. FLASHING MUST BE TAPED TO RIGID UNDERLAY SYSTEM PLASTERED PARAPET/BALUSTRADE DETAIL PP 501

3 WINDOW TRIMMING STUD 100mm MIN. 100mm MIN. DRAIN FORMED IN CORNERS mm MIN. TO FACE OF WINDOW OR DOOR JAMB STUD STOTHERM 20mm VH CAVITY BATTEN RENDER SYSTEM E2/AS1 COMPLIANT BACK FLASHING ON CAVITY BATTENS BALUSTRADE LAPPED AROUND CORNER 150mm MIN. POREN MINERAL PANEL ADHESIVE OR AAC 2 HR CONSTRUCTION GLUE ON ALL PANEL JOINTS SYSTEM PARAPET and/or ENCL.BALUSTRADE WALL JUNCTION - PLAN PP 502

4 WALL FRAMING FLEXIBLE FLASHING TAPE DRESSED UP AND SECURELY ADHERED TO WALL UNDERLAY AT REAR OF CAVITY CONTINUE FLASHING TAPE OR ROOF UNDERLAY OVER H3.1 CAPPING PLATE H3.1 CAPPING PLATE CUT AT 10 SLOPE DRAIN FORMED IN CORNER CAVITY BATTENS NOTE: PANEL CAP TO BE POSITIONED UNDER WALL 10mm OFF FRAMING E2/AS1 COMPLIANT BACK FLASHING REQUIRED ON TOP OF BATTENS IN CORNER TO COVER PANEL JOINT. SEE DETAIL 502 SYSTEM FLEXIBLE FLASHING INSTALL - ISOMETRIC PP 503

5 2 LINES OF SEALANT 50mm MIN 100mm MIN 50mm MIN Refer E2/AS1 for lengths 8mm EXPANSION GAP BETWEEN PARAPET CAP AND SADDLE FLASHING - USE MS SEALANT 5 o MIN SLOPE PARAPET CAP 5 o MIN SLOPE DASHED LINE INDICATES SADDLE FLASHING UNDER RIVET CAP THROUGH TOP OVER SEALANT BEADS TO SECURE SADDLE FLASHING, SOAKERS AND JOINS. A. SADDLE FLASHING METAL PARAPET CAP FLASHING FIXED THROUGH THE SIDES. B. PARAPET CAP PARAPETS TO FALL TO INTERIOR SIDE. COVER TO CLADDING AS PER E2/AS1 TABLE 7 PARAPETS MUST BE OFFSET FROM WALLS RUNNING PARALLEL TO PARAPET WALL TO ALLOW FOR INTERNAL CORNER BACKFLASHINGS SYSTEM STO 20mm VH CAVITY BATTENS PLACE CAP FLASHING OVER SADDLE FLASHING - REFER TO E2/AS1 FIGURE 12 FOR CAP FIXING DETAILS. H3.1 CAPPING PLATE CUT TO A FALL WITH FLASHING TAPE OR ROOFING UNDERLAY INTERNAL CLADDING BACK FLASHING UNDER CLADDING NOTE: SADDLE FLASHING INSTALLED OVER CLADDING. WITH BACK FLASHINGS REQUIRED ON TOP OF CAVITY BATTENS TO INTERNAL CORNERS UNDER CLADDING. CAP FLASHING JOINS INSTALLED OVER SOAKER FLASHINGS WITH MINIMUM 50mm OVER LAP BOTH SIDES WITH 5mm GAP AND 6mm SEALANT BEADS UNDER FLASHING OR 100mm OVERLAPPED JOINTS RIVETED THROUGH SEALANT. REFER FIG. 9 E2/AS1 SYSTEM METAL SADDLE FLASHING & CAP INSTALL PP 504

6 WALL FRAMING STO 20mm VH CAVITY BATTEN OVERLAY OF STOFLEXYL MEMBRANE UNDER MESH COAT TO TOP & SIDES 100mm MIN. DOWNTURN OVER LEVELITE BASE COAT RENDER LEVELLITE BASECOAT RENDER PANEL CAP FLASHING TAPE OR ROOF UNDERLAY OVER H3.1 TIMBER CAPPING PLATE WITH MIN. 10 O FALL STO 20mm VH CAVITY BATTENS 100mm NOTE: APPLY STOFLEXYL MESHED WATERPROOFING OVER BASECOAT STOFLEXYL MESHED WATERPROOFING HAS BEEN TESTED BY BRANZ TO MEET THE REQUIREMENTS OF AS/NZS4858 FOR A WATERPROOFING MEMBRANE AS REQUIRED BY E2/AS1 SYSTEM STOFLEXYL MESHED SADDLE FLASHING - ISOMETRIC PP 505

7 OVERLAY OF STOFLEXYL MEMBRANE UNDER MESH COAT TO TOP & SIDES 100mm MIN. DOWNTURN OVERBASE COAT RENDER E2/AS1 REQUIRES BALCONY & PARAPET WALLS TO BE OFFSET FROM MAIN WALL PLANE TO ALLOW FOR SADDLE FLASHINGS BASECOAT RENDER, CAP OVER H3.1 TIMBER CAPPING PLATE 10 FALL 100mm NOTE: APPLY STOFLEXYL MESHED WATERPROOFING OVER BASECOAT STOFLEXYL MESHED WATERPROOFING HAS BEEN TESTED BY BRANZ TO MEET THE REQUIREMENTS OF AS/NZS4858 FOR A WATERPROOFING MEMBRANE AS REQUIRED BY E2/AS1 SYSTEM STOFLEXYL MESHED WATERPROOFING CAP PP 506

8 10 10 MIN.FALL TO TOP OF PARAPET H3.1 TIMBER CAPPING PLATE - CUT TO 10 SLOPE WITH FLASHING TAPE OR ROOFING UNDERLAY OVER STOTHERM 20mm VH CAVITY BATTEN CONTINUOUS OVER TOP OF WALL FRAME RENDER SYSTEM STO PREMESHED PVC ADJUSTABLE CORNER ANGLES OVERLAY OF STO FLEXYL MEMBRANE UNDER MESH COAT TO TOP & SIDES, 100mm MIN. DOWNTURN OVER BASE COAT 20mm DRAINED CAVITY RENDER SYSTEM DRESS OVER MEMBRANE AND BASE CAP SOLID BLOCKING STO upvc VENTED BASE CAP FULLY SUPPORTED MEMBRANE UPSTAND 20mm MIN.ANGLE FILLET DECK FRAMING TO NZS3604 OR ENGINEERS DESIGN NOTE: HANDRAIL REQUIRED WHERE BALUSTRADE IS UNDER 1000mm. ALLOW EXTRA CLADDING CLEARANCE TO DECK AND INCREASE MEMBRANE UPSTAND WHERE TILING IS ANTICIPATED. SYSTEM BALUSTRADE ENCLOSED DECK DETAIL PP 507

9 150mm MIN. 100mm MIN. 35 RENDER SYSTEM FULLY SUPPORTED MEMBRANE TO RUN UP 150mm MIN.ABOVE DECK LEVEL MEMBRANE REINFORCING STRIP VENTED CAVITY BASE CLOSER STO upvc ADJUSTABLE FOOT TRAY SELECTED MEMBRANE FINISH OVER H3 "C" FACED PLYWOOD LAID TO 1:40 MIN.FALL. GLUE & SCREW TO TIMBER JOISTS, ALL EDGES SUPPORTED ON TIMBER 20mm MIN. ANGLE FILLET 35mm MIN. AT HIGHEST POINT OF DECK/ROOF AT 10mm DRIP EDGE NOTE: - 100mm MIN. FROM FLOOR LEVEL FOR ENCLOSED DECKS - MIN.FALLS: 1:40 FOR DECKS, 1:30 FOR ROOFS & 1:100 FOR GUTTERS - ALLOW FOR TILES IF REQUIRED - MAINTAIN CLEARANCES AND UPSTANDS FOR TILES SYSTEM ENCLOSED DECK DETAIL PP 508

10 12 20mm DRAINED CAVITY RENDER SYSTEM 6mm STO upvc FINISHING EDGE, SEAL END PANEL WITH S PROTECT WS mm MAX.DRAINAGE LINE OF CANTILEVER JOIST - SHOWN DASHED 5mm MIN. GAP BETWEEN RENDER SYSTEM AND SADDLE FLASHING SOLID BLOCKING BETWEEN JOISTS STO JOINT SEAL TAPE & MS SEALANT TO TOP AND SIDES 35 5 LINE OF CLADDING BETWEEN JOISTS - SHOWN DASHED, CUT AROUND JOIST 5 35 MIN.COVER CONTINUOUS INTER-STOREY FLASHING RENDER SYSTEM 6mm STO upvc FINISHING EDGE, SEAL END PANEL WITH S PROTECT WS 205 NOTE: REFER E2/AS1 Fig.16 FOR FLASHING REQUIREMENTS. PROVIDE 6-8mm WIDE SEALANT JOINT AT CLADDING/SADDLE FLASHING JUNCTION. 50mm MIN. SET DOWN FROM FLOOR OR THRESHOLD FOR CANTILEVERED SLATTED DECKS SYSTEM CANTILEVERED SLATTED DECK PP 509

11 FLOORING 12 STO 20mm VH CAVITY BATTEN RENDER SYSTEM DECKING FLOOR JOIST DECK FRAMING UNDERFLOOR INSULATION AS REQUIRED 50 ANGLED CAVITY SPACERS TO SUIT STO upvc VENTED ADJUSTABLE FOOT TRAY SYSTEM NON CANTILEVERED SLATTED DECK PP 510

12 20mm DRAINED CAVITY RENDER SYSTEM FLASHING TAPE 100mm ONTO WALL UNDERLAY 25mm ONTO BRACKET GALVANIZED OR STAINLESS STEEL L BRACKET ENGINEERED FOR LOAD TIMBER BEAM MS SEALANT ON STO JOINT SEAL TAPE LINE OF STO JOINT SEAL TAPE - SHOWN DASHED 12mm MIN.GAP NOTE: 'L' BRACKET ENGINEERED FOR LOAD. FLASHING TAPE TO BUILDING UNDERLAY IN ACCORDANCE WITH E2/AS1 FIG. 68 SYSTEM TIMBER BEAM / PERGOLA DETAIL SCALE 1:2 PP 511

13 20mm DRAINED CAVITY RENDER SYSTEM MS SEALANT OVER STO JOINT SEAL TAPE BETWEEN PANEL AND BRACKET FIXING CAPACITY AS PER ENGINEER 40 TIMBER BEAM TO BE FIXED AFTER RENDERING COMPLETE 40mm GAP RECOMMENDED (12mm MIN. GAP) GALVANIZED OR STAINLESS STEEL 'H' or 'U' BRACKET, SEAL BRACKET WITH MS SEALANT OVER PEF ROD ENGINEERED TO SPECIFIC STRUCTURAL REQUIREMENTS RENDER SYSTEM 20mm DRAINED CAVITY NOTE: INSTALL FLASHING TAPE OVER BRACKET ONTO BUILDING UNDERLAY AS PER E2/AS1 fig 68, ALSO REFER TO DETAIL 510 MANUFACTURED GALVANIZED STEEL 'H' OR 'U' BRACKET FOR PARALLEL JOISTS OR USE 'L' BRACKET FOR RIGHT ANGLE CONNECTIONS INSTALL DECK JOIST AFTER CLADDING IS RENDER FINISHED 40mm GAP RECOMMENDED FOR FIXINGS AND RENDERING SYSTEM PARALLEL DECK JOIST BRACKET PP 512

14 PRE FINISHED 0.55MM BMT STEEL CUSTOM FOLDED AND RIVETED RAIN WATER HEAD A mm LIP RWH HEAD FIXED DIRECTLY ABOVE & BELOW SCUPPER PENETRATION EPDM WASHERS REQUIRED AROUND FIXINGS AND PLATE TO PROVIDE WATERTIGHTNESS STOPLEX W SEALER & MS SEALANT AROUND OPENING/RHW MEMBRANE DRESSED OVER 50x50mm ALU.ANGLE REBATED INTO SUBSTRATE A LEAF SCREEN TO OVERFLOW. AREA OF OVERFLOW TO BE 1.5 X CROSS SECTION OF DOWNPIPE AREA. OVERFLOW BELOW OPENING LEVEL 200mm MIN. OUTLET THROUGH WALL LINE OF MEMBRANE LAPPED 150mm ABOVE DECK LINE OF UNDERLAY OUTLET THROUGH WALL SELECTED MEMBRANE FINISH OVER H3 "C" FACED PLYWOOD LAID TO 1:60MIN.FALL. GLUE & SCREW TO TIMBER JOISTS, ALL EDGES SUPPORTED ON TIMBER 20mm MIN.ANGLE FILLET 25mm MIN GUTTER WALLS, 75mm MIN. FROM GUTTER TO CLADDING SECTION A - A SYSTEM RWH/SCUPPER OPENING PP 513