Transcription

1 .0 EXTERIOR SKIN PROFILES: A. SHADOWLINE - 68mm (46") PANEL MODULE.0 EXTERIOR SKIN PROFILES: B. MICRORIB - 68mm (46") PANEL MODULE 02mm 25mm 02mm EXPOSED SURFACE 38.mm 38.mm 38.mm EXPOSED SURFACE.52mm.52mm 46" FIXED WIDTH SHADOW LINE PROFILE 46" FIXED WIDTH MICRORIB PROFILE GENERAL NOTES FOR SPI ISOWALL PANEL.0 Material: Panel: - 0" (50.8mm - 254mm) thick Core: Rigid Expanded Polystyrene (EPS) Exterior Siding Sheet: Fabricated from Z275 steel material conforming to ASTM A653M grade 230 steel VARIES TO SUIT VARIES TO SUIT Interior Liner Sheet: Fabricated from Z275 steel material conforming to ASTM A653M grade 33 steel GENERAL NOTES FOR SPI ROCKWALL PANEL.0 Material: Panel: 2.5" - 0" (63.5mm - 254mm) thick Core: PERMANENTLY BONDED MINERAL WOOL Exterior Siding Sheet: Fabricated from Z275 steel material conforming to ASTM A653M grade 230 steel Interior Liner Sheet: Fabricated from Z275 steel material conforming to ASTM A653M grade 33 steel 207 STANDARD DETAILS - PANEL PROFILE.

2 3.0 Typical Corner Installation -/X-/ 3.0 Once Structural Panels Inc panels have been erected and secured into place flashing must be installed to complete the installation Apply Adfast Adseal 4800 silicone sealant in one continuous bead to inside of flashing so an air tight seal is achieved Flashing is secured to the panel with #8 Tek self-drilling screws installed ½ from outside edge at 2 OC increments along the length. NOTE: CORNERS MUST BE PLUMB AND STRAIGHT WITH ADJACENT PANELS CONTACTING EACH OTHER. IF THESE CONDITIONS ARE NOT MET IT IS POSSIBLE THAT ANY SUPPLIED CORNER FLASHINGS WILL NOT FIT PROPERLY. Varies (2.5" Rockwall) - 0" 68mm panel butt joint corner PLAN VIEW 68mm panel butt joint OC TYPICAL INSIDE CORNER PANEL AND FLASHING ASSEMBLY TYPICAL OUTSIDE CORNER PANEL AND FLASHING ASSEMBLY STANDARD DETAILS - BUTT JOINT CORNER.0

3 Panel Thickness EPS or Rockwall core CFIA accepted 26ga min G-90 Hot Dipped Galvanized steel pre-coated with standard finish [both interior and exterior] * panel joint Female Joint Varies (2.5" Rockwall) - 0" Male Joint Field applied silicone in panel joint Internally caulked panel joint 46" Fixed Panel Width PLAN VIEW CFIA accepted 26ga min G-90 Hot Dipped Galvanized steel pre-coated with standard finish [both interior and exterior] EPS or Rockwall core Female Joint Varies (2.5" Rockwall) - 0" Male Joint Field applied silicone on surface of panel joint Externally caulked panel joint 46" Fixed Panel Width * NONCOMBUSTIBLE ROCKWALL CONSTRUCTION ONLY. FOR FIRE RATED SYSTEM DETAILS PLEASE REFER TO FIRE RATED DRAWING SET. PLAN VIEW STANDARD DETAILS - PANEL JOINT.2

4 Varies Varies Galvanized or colour matched base drip flashing U-channel base flashing Colour matched to panel OC AdFast 802 Urethane Colour matched base trim Nail-in anchor AdFast sealant Tek screw #8 x 3/4 "U" channel base *varies Tek 5 through panel fastener Tek screw #8 x 3/4 Nail-in anchor 2 " Gauged steel base 'L' with drip Fastened with nail-in anchors Sealed with AdFast sealant Varies to suit panel SECTION VEIW SECTION VEIW Varies to suit panel INSTALLING ISOWALL OR ROCKWALL PANELS FROM INSTALLING ISOWALL OR ROCKWALL PANELS FROM CONCRETE FLOOR:.0 PANEL INSTALLATION:. Apply AdFast sealant to concrete floor as shown beneath U-channel base..2 Install U-channel base in desired location, fastening U-channel to concrete floor using ¼ X nail in fasteners at 6 OC minimum. Special care should be taken to ensure a straight run is maintained for proper installation..3 Stand panel into place and fasten bottom of panel to U-channel using s at 2 OC..4 Stand each additional panel and slide into position and engage lips of adjacent panel. Maintain uniform side joints in order to maintain panel module. Once panel is engaged and in position, repeat step.3..5 Repeat steps.3 and.4 until all wall panels are standing and secured in desired position. CONCRETE CURB:.0 PANEL INSTALLATION:. Apply AdFast sealant to concrete curb as shown beneath drip base..2 Install drip base in desired location, fastening drip to concrete floor using ¼ X nail in fasteners at 6 OC minimum. Special care should be taken to ensure a straight run is maintained for proper installation..3 Stand panel into place and fasten bottom of panel to drip base using Tek 5 screws, 3 screws per panel minimum..4 Stand each additional panel and slide into position and engage lips of adjacent panel. Maintain uniform side joints in order to maintain panel module. Once panel is engaged and in position, repeat step.3..5 Repeat steps.3 and.4 until all wall panels are standing and secured in desired position. OC Offset base flashing. Colour matched to panel Galvanized or colour matched base drip flashing AdFast 802 Urethane Nail-in anchor STANDARD DETAILS - BASE CONNECTIONS 0

5 WALL TO CEILING CORNER WALL TO CEILING CONNECTION Varies (2.5" Rockwall) - 0" Varies (2.5" Rockwall) - 0" -/X-/ -/X-/ -/X-/ Varies (2.5" Rockwall) - 0" Varies (2.5" Rockwall) - 0" SECTION VIEW SECTION VIEW -/X-/ OC -/X-/ OC STANDARD DETAILS - WALL TO CEILING 0

6

7 Seal flashing to penetrant using urethane sealant. Install flashing around penetrant. Fasten flashing to panel using self drilling trim scres. Install penetrant through cut-out Urethane sealant around perimeter of cut-out Urethane sealant in panel joint, continous into cut-out STANDARD DETAILS - Penetration Flashing 0