Download "'Rose Avenue Project'"

Transcription

1

2

3

4 B1 B2 A1 A2 'Rose Avenue Project' Drafting & Design Tom Masters SITE PLAN A1 Kelowna, BC (250)

5 NOTES PROVIDE FIRE STOPS IN ACCORDANCE WITH BC BUILDING CODE REFERENCE AND SMOKE ALARMS IN ACCORDANCE WITH REFERENCE PROVIDE DAMPROOFING, WATERPROOFING AND SOIL GAS CONTROL IN ACCORDANCE WITH BC BUILDING CODE REFERENCE SECTION 9.13 & FOOTINGS ARE TO BE PLACED ON UNDISTURBED OR COMPACTED SOIL WITH AN ALLOWABLE BEARING PRESSURE OF 2000LBS/SQ.FT. OR GREATER. FOOTINGS ARE TO BE PLACED ON UNDISTURBED OR COMPACTED SOIL WITH AN ALLOWABLE BEARING PRESSURE OF 2000LBS/SQ.FT. OR GREATER.COMPACTION TO BE TESTED BY QUALIFIED PROFESSIONAL OR GEOTECHNICAL ENGINEER. 'Rose Avenue Project' SPECIFICATIONS EXTERIOR WALL: ACRYLIC STUCCO ON PAPER & WIRE BASE W/SCRATCH COAT 1 2" SHEATHING 2x6 16"O.C. R-24 BATT INSULATION 6 MIL POLY V.B. (U.V. RESISTANT) 5/8" GYPSUM BOARD GARAGE FLOOR: CONCRETE SLAB SLOPE 2" MIN FOR DRAINAGE EXTERIOR FOUNDATION: 2 COATS ASPHALT EMULSION 8" CONCRETE FOUNDATION WALL 3" RIGID INSULATION TO BELOW FROST LINE W/PROTECTION MIN 24" BELOW FINISH GRADE 24"x8" CONCRETE FOOTING INTERIOR FOUNDATION: 6" CONCRETE CURB 16" x 8" CONCRETE FOOTING DRAINAGE: 6" MIN DRAIN ROCK COVER 4" DIA. DRAIN TILE BELOW GRADE WALL ASSEMBLY DESCRIPTION 8" FOUNDATION WALLS W/2X6 W/R-24 BATT INSULATION NOMINAL RSI.2.66 EFFECTIVE (R-15.1) OTHER BUILDING ENCLOSURE LAYERS CONTRIBUTE TO EFFECT INSUL: 1. DAMPROOFING/INTERIOR AIR FILM TOTAL EFFECTIVE INSULATION VALUE (@24" O.C. FRAMING) MINIMUM EFFECTIVE THERMAL RESISTANCE FOR BELOW GRADE WALLS W/HRV MINIMUM EFFECTIVE THERMAL RESISTANCE FOR BELOW GRADE WALLS RSI 2.99 (R-17.0) RSI 2.98 (R-16.92) RSI 2.98 (R-16.92) Drafting & Design Tom Masters BASEMENT A4 PLAN Kelowna, BC (250) kelowna635@gmail.com

6 SPECIFICATIONS ROOF: TORCH-ON MEMBRANE 5 8" T&G PLYWOOD ON ENG'D ROOF 24"O.C. CEILING: R-50 BATT INSULATION 6 MIL V.B. (U.V. RESISTANT) 1/2" ANTI-SAG GYPSUM BOARD FASCIA/SOFFIT: EXTERIOR FINISH AS PER ELEVATIONS VENTED ALUM. SOFFIT/T&G WOOD SOFFIT EXTERIOR WALL: EXTERIOR FINISH AS PER ELEVATIONS 1/2" SHEATHING 2x6 16"O.C. R-24 BATT INSULATION 6 MIL POLY V.B. (U.V. RESISTANT) 1/2" GYPSUM BOARD (FRONT & REAR) 5/8" TYPE 'X' GYPSUM BOARD (SIDES) INTERIOR PARTITION: 1/2" GYPSUM BOARD 2x4 16" O.C. SLAB ON GRADE FLOOR: 4" CONCRETE SLAB 6 MIL POLY COMPACTED GRAVEL B1 A1 B2 A2 'Rose Avenue Project' ABOVE GRADE WALL ASSEMBLY (HARDI SIDING) DESCRIPTION R-24 BATT INSULATION IN 2X6 WOOD 24" O.C. NOMINAL RSI 4.23 EFFECTIVE (R-15.1) OTHER BUILDING ENCLOSURE LAYERS CONTRIBUTE TO EFFECT INSUL: 1. EXTERIOR AIR FILM 2. HARDI SIDING 3. BUILDING PAPER 4. N/A " PLYWOOD SHEATHING 6. POLYETHYLENE " TYPE X GYPSUM WALL BOARD 8. INTERIOR AIR FILM N/A N/A TOTAL EFFECTIVE INSULATION VALUE (@24" O.C. FRAMING) MINIMUM EFFECTIVE THERMAL RESISTANCE FOR ABOVE GRADE WALLS W/HRV MINIMUM EFFECTIVE THERMAL RESISTANCE FOR ABOVE GRADE WALLS RSI 4.42 (R-17.24) RSI 2.97 (R-16.86) RSI 3.08 (R-17.49) Drafting & Design Tom Masters MAIN FLOOR A3 PLAN Kelowna, BC (250) kelowna635@gmail.com

7 ROOF ASSEMBLY - CATHEDRAL CEILINGS DESCRIPTION R-50 BATT INSULATION IN ENG. 24" O.C. NOMINAL RSI 8.81 OTHER BUILDING ENCLOSURE LAYERS CONTRIBUTE TO EFFECT INSUL: 1. INTERIOR AIR FILM " GYPSUM BOARD SHEATHING 4. ROOF FINISH TOTAL EFFECTIVE INSULATION VALUE (@24" O.C. FRAMING) MINIMUM EFFECTIVE THERMAL RESISTANCE W/HRV MINIMUM EFFECTIVE THERMAL RESISTANCE EFFECTIVE (R-50.0) RSI 9.12 (R-51.75) RSI 4.67 (R-26.5) RSI 4.67 (R-26.5) 'Rose Avenue Project' ABOVE GRADE WALL ASSEMBLY (HARDI SIDING) DESCRIPTION R-24 BATT INSULATION IN 2X6 WOOD 24" O.C. NOMINAL RSI 4.23 EFFECTIVE (R-15.1) OTHER BUILDING ENCLOSURE LAYERS CONTRIBUTE TO EFFECT INSUL: 1. EXTERIOR AIR FILM 2. HARDI SIDING 3. BUILDING PAPER 4. N/A " PLYWOOD SHEATHING 6. POLYETHYLENE " TYPE X GYPSUM WALL BOARD 8. INTERIOR AIR FILM N/A N/A TOTAL EFFECTIVE INSULATION VALUE (@24" O.C. FRAMING) MINIMUM EFFECTIVE THERMAL RESISTANCE FOR ABOVE GRADE WALLS W/HRV MINIMUM EFFECTIVE THERMAL RESISTANCE FOR ABOVE GRADE WALLS RSI 4.42 (R-17.24) RSI 2.97 (R-16.86) RSI 3.08 (R-17.49) Drafting & Design Tom Masters UPPER FLOOR A4 PLAN Kelowna, BC (250) kelowna635@gmail.com

8

9

10

11 'Rose Avenue Project' Drafting & Design Tom Masters ROOF PLAN A5 Kelowna, BC (250)

12 'Rose Avenue Project' Drafting & Design Tom Masters SECTIONS A8 Kelowna, BC (250)

13 'Rose Avenue Project' Drafting & Design Tom Masters SECTIONS A9 Kelowna, BC (250)

14 'Rose Avenue Project' Drafting & Design Tom Masters LANDSCAPE L1 PLAN Kelowna, BC (250)