BUILDING 15 PROJECT AREA

Size: px
Start display at page:

Download "BUILDING 15 PROJECT AREA"

Transcription

1 INDEX TO DRAWINGS MARK SHEET TITLE GENERAL G.0 TITLE SHEET AND INDEX TO DRAWINGS ARCHITECTURAL D.0 DEMOLITION PLAN A.0 LIFE SAFETY PLAN A. FLOOR PLAN A.2 REFLECTED CEILING PLAN A.3 CLEARANCES, MOUNTING HEIGHTS & WALL TYPES A6.0 HEDULES, ELEVATIONS & DETAILS STRUCTURAL L3 CRESTVIEW AEROSPACE S-0 S- S-2 GENERAL NOTES PLANS & DETAILS ELEVATIONS & DETAILS FIRE PROTECTION BUILDING 5 ENTRY FP.0 FIRE PROTECTION FLOOR PLAN FP2.0 FIRE PROTECTION DETAILS MECHANICAL RENOVATION M.0 M2.0 PLUMBING HVAC FLOOR PLAN HVAC NOTES, HEDULE, LEGEND & DETAILS OPE OF WORK THE RENOVATION TO BUILDING 5 ON THE L-3 CRESTVIEW AEROSPACE CAMPUS OF THE BUILDING ENTRY, RESTROOM AREAS, KITCHEN AND BREAK ROOM. APPROXIMATELY 3,000 SQUARE FOOTAGE OF FLOOR SPACE IS INCLUDED WITHIN THIS RENOVATION. EXISTING IT CLOSET SHALL REMAIN IN USE AND UNTOUCHED THROUGHOUT CONSTRUCTION. NEW 4' WIDE CONCRETE WALKWAY CONNECTING TURNSTILE TO COVERED ENTRY WITH INSTALLATION OF NEW CONCRETE DRAIN PIPE TO BE INCLUDED WITHIN OPE. CANOPY ENTRY MODIFICATIONS SHALL INCORPORATE A CANOPY SYSTEM THAT TIES INTO THE EXISTING ADMINISTRATION BUILDING. MODIFICATIONS TO EXISTING COVERED SEATING AREA STRUCTURE AT BUILDING 5 ENTRY SHALL BE INCORPORATED TO ACCEPT NEW CANOPY. EXISTING IRRIGATION SYSTEM SHALL ALSO BE MODIFIED TO INCORPORATE NEW CANOPY FOUNDATIONS. INSTALLATION OF A NEW STOREFRONT ENTRY DOOR. EXISTING EXTERIOR LIGHTING SHALL BE REUSED. TOILETS TEMPORARY RESTROOM SERVICE WILL BE SUPPLIED BY L-3 CRESTVIEW AEROSPACE DURING CONSTRUCTION. NEW TOILET ROOMS SHALL COMPLY WITH CURRENT ADA STANDARDS AND MEET FIXTURE COUNT REQUIREMENTS PER FLORIDA PLUMBING CODE 204. WALLS SURROUNDING TOILET ROOMS SHALL EXTEND TO UNDERSIDE OF ROOF DECK. ALL COMMODE FIXTURES SHALL BE WALL MOUNTED, AND TOILET PARTITIONS CEILING MOUNTED. WALL TILE SHALL EXTEND 6' A.F.F. WITH AN EPOXY FLOOR SYSTEM. KITCHEN / BREAK ROOM OPE OF WORK INCLUDES ENLARGING THE BREAK ROOM AREA TO ACCOMMODATE A LARGER NUMBER OF STAFF. FIXTURES AND CASEWORK IN KITCHEN SHALL BE NEW. EXISTING VENDING MACHINES SHALL BE REUSED AND SHOWN IN NEW LOCATIONS ON FLOOR PLAN. NEW REFRIGERATOR AND 4 MICROWAVES ARE TO BE PROVIDED WITHIN THIS OPE OF WORK. CONNECTOR SIDEWALK INSTALL 4' WIDE BY +/- 23'-4" CONCRETE WALKWAY (5000psi) WITH 2" DIAMETER DRAINAGE PIPE TO CONNECT SECURITY TURNSTILE GATE TO COVERED PORCH. OPE INCLUDES DEMOLITION OF EXISTING WOOD WALKWAY HANDRAILS. REMOVE EARTH RETAINING BOARDS AND REPLACE WITH DECORATIVE RETAINING BLOCKS. FIELD VERIFY ALL DIMENSIONS AND MATERIAL QUANTITIES PRIOR TO BID PROPOSAL. TOILET FACILITIES - ALTERNATE CONTRACTOR SHALL INCLUDE IN BIDS TEMPORARY TOILET SERVICE (ROYAL RESTROOM TRAILER OR EQUAL), SEPARATE FROM CONSTRUCTION TOILETS, TO ACCOMMODATE EMPLOYEES DURING CONSTRUCTION. PROVIDE MINIMUM 3 MALE AND 3 FEMALE TOILETS, INCLUDE HANDICAP STALL FOR EACH. SERVICE INCLUDES SETUP, CONNECTION TO EXISTING PLUMBING, IF REQUIRED, AND SERVICE DURING CONSTRUCTION. GENERAL NEW 2x4 ACT TILE CEILINGS SHALL BE RAISED UP TO CLEAR. EXISTING LIGHT FIXTURES SHALL BE REUSED AND RE-LAMPED AS NECESSARY TO BRING TO FM GLOBAL STANDARDS. MECHANICAL SYSTEMS SHALL BE REPLACED TO ACCOMMODATE NEWLY DESIGNED ASSEMBLY AREA AND TOILET ROOMS. GENERAL NOTES CONTRACTOR MUST HAVE ON SITE SUPERVISION AT ALL TIMES DURING CONSTRUCTION. NO EXCEPTIONS. 2 ALL VISITORS ARE REQUIRED TO PASS SECURITY BACKGROUND INVESTIGATIONS PRIOR TO ENTERING THE FACILITY. 3 A CONSTRUCTION HEDULE MUST BE SUBMITTED AND APPROVED BY THE PROJECT MANAGER PRIOR TO COMMENCING WORK. 4 ALL SUBMITTALS ARE TO BE SUBMITTED AND APPROVED THROUGH THE DESIGN TEAM. 5 WEEKLY PROGRESS MEETINGS ARE TO BE CONDUCTED BY THE GENERAL CONTRACTOR WITH THE OWNER DURING WHICH ITEMS HEDULED FOR COMPLETION IN THE COMING WEEK WILL BE COVERED, OUTSTANDING ITEMS WHICH DID NOT COMPLETE FROM THE PRIOR MEETING AND OF COURSE ANY OTHER ISSUES, QUESTIONS, ETC CAN BE ADDRESSED AS WELL. 6 JOB SITE CLEANLINESS IS REQUIRED THROUGHOUT THE PROJECT. A FINAL AND THOROUGH CLEANING IS REQUIRED AT THE COMPLETION OF THE PROJECT. 7. BIDDING CONTRACTORS SHALL PROVIDE FIXED PRICE FOR CONSTRUCTION OF PROJECT FAIRCHILD ROAD CRESTVIEW, FLORIDA BUILDING 5 FLOOR PLAN ALE: /32" = '-0" 6' 8' 0 6' 32' BUILDING 5 +/- 23'-4" PROJECT AREA 4'-0" EXISTING CONCRETE PORCH TO REMAIN NEW 2" DRAINAGE PIPE NEW 6" CONCRETE SIDEWALK (5000psi) NEW RETAINING BLOCKS EXSITING FENCE TO REMAIN EXSITING SIDEWALK TO REMAIN P.0 P2.0 ELECTRICAL E0.0 E.0 E2.0 E2.02 APPLICABLE CODES BUILDING CODE FLORIDA BUILDING CODE 204 FLORIDA BUILDING CODE EXISTING BUILDING PLUMBING CODE MECHANICAL CODE ELECTRICAL CODE ACCESSIBILITY BUILDING AREA GROSS SQUARE FOOTAGE B OCCUPANCY TOTAL:,900 SQUARE FEET RENOVATED SQUARE FOOTAGE: 3,000 SQUARE FEET CODE ANALYSIS FLORIDA BUILDING CODE B - BUSINESS OCCUPANCY - RENOVATED BREAK ROOM F- - FACTORY OCCUPANCY - EXISTING MANUFACTURING TABLE EXISTING FIRE BARRIER BETWEEN B & F- - EXISTING TABLE 76.5 EXISTING DOORS FROM B TO F- SHALL MEET DOOR REQUIRMENTS TABLE SPRINKLERED BUILDING EXIT ENCLOSURES & EXIT PASSAGEWAYS: CLASS B FINISH CORRIDORS: CLASS B FINISH ROOMS & ENCLOSED SPACES: CLASS C FINISH 903 EXISTING SPRINKLER SYSTEM PROVIDED 906 FIRE EXTINGUISHERS REQUIRED THROUGHOUT BUILDING CH. 0 OCCUPANT LOAD (ASSEMBLY): 00 SQ.FT/PERSON (GROSS) 20 OCCUPANTS TOTAL 005. EGRESS WIDTH: OTHER COMPONENTS= 0.2"/PERSON TABLE 006 EMERGENCY LIGHTING IS REQUIRED 008. REQUIRED EGRESS DOORS WILL COMPLY WITH ADA 0 EXIT SIGNS REQUIRED ALONG THE EGRESS PATH 04.3 COMMON PATH OF EGRESS TRAVEL: 00 FEET IN GROUP B TABLE 06. EXIT ACCESS TRAVEL DISTANCE: 300FT. MAX (SPRINKLERED) CH. ACCESSIBILITY: PARKING CLEAR FLOOR SPACE ACCESSIBLE PATH ACCESSORY MOUNTING TACTILE SURFACES HEIGHT THRESHOLD ELEVATION CLEAR WIDTH EMERGENCY LIGHTING CH. 2 ENVIRONMENT- REFER TO MEP CH. 3 WILL COMPLY WITH FLORIDA ENERGY EFFICIENCY CODE TABLE 505. ROOF ASSEMBLY MINIMUM OF CLASS C COMPONENTS COMPLY WITH WIND ZONE REQUIREMENTS CH. 8 FLORIDA BUILDING CODE EXISTING BUILDING CH. 3 PRERIPTIVE COMPLIANCE 504 LEVEL 2 ALTERATION CH. 8 LEVEL 2 ALTERATION SITE INFORMATION WIND LOAD: EXPOSURE: RISK CATEGORY: JURISDICTION: SYMBOLS LEGEND DRAWING NO. DRAWING TITLE A-400 PLUMBING FLOOR PLAN, HEDULE & NOTES PLUMBING RISERS & DETAILS ELECTRICAL LEGEND, NOTES & POWER RISER DIAGRAM ELECTRICAL DEMOLITION PLAN NEW WORK POWER & SIGNAL PLAN NEW WORK LIGHTING PLAN DRAWING ALE: /8" = '-0" DRAWING NO. SHEET NO. FLORIDA PLUMBING CODE 204 FLORIDA MECHANICAL CODE 204 NEC 20 FLORIDA ACCESSIBILITY CODE 204 DESIGN FOUNDATION TO WORK WITH RECORDED SOIL AND ALLOWABLE SOIL PRESSURE. STATE REQUIREMENTS ON CONSTRUCTION DOCUMENTS 89 COMPLY WITH REQUIRMENTS FOR HURRICANE ZONE 820 COMPLY WITH REQUIRMENTS FOR HURRICANE ZONE 40 MPH FASTEST MILE WIND LOAD EXPOSURE "B" II OKALOOSA COUNTY SECTION SYMBOL 234 ELEVATION SYMBOL SPOT ELEVATION WINDOW TYPE KEY NOTE DOOR NUMBER ROOM NUMBER 7 JAN 7 jdf Date: Drawn By: TITLE SHEET & CODE ANALYSIS Project Number: 627 L-3 Crestview Aerospace Revisions Building 5 Entry Renovation 5486 FAIRCHILD ROAD CRESTVIEW, FLORIDA FOR BID XX XXX 6 G.0

2 DEMOLITION LEGEND PORTION OF BUILDING TO BE REMOVED EXISTING WALLS TO REMAIN NOTES: ALL CEILING MATERIAL AND ALL FLOOR MATERIAL SHALL BE REMOVED THROUGHOUT OF BUILDING PROJECT OPE. DOOR & WALL TO BE REMOVED NOTES: ALL CEILING MATERIAL AND ALL FLOOR MATERIAL SHALL BE REMOVED THROUGHOUT OF BUILDING PROJECT OPE. REFERENCE MECHANICAL, PLUMBING AND ELECTRICAL FOR FURTHER DEMOLITION REQUIREMENTS. HVAC EQUIPMENT TO BE REMOVED EXISTING PLUMBING WALL TO REMAIN EXISTING WATER HEATER TO BE REMOVED PORTION OF EXISTING CONCRETE FLOOR TO BE DEMOLISHED TO INSTALL NEW SEWER LINES FOR REDEISGNED TOILET ROOMS; COORDINATE WITH PLUMBING PLANS FOR LOCATIONS DOOR TO BE REMOVED; OPENING TO BE REPAIRED WITH SURROUNDING MATERIALS REMOVE EXISTING CONCRETE WALKWAY REMOVE EXISTING CONDENSING UNITS AND CONCRETE PADS 3'-0" 4" EXISTING STEEL BEAM TO BE REMOVED; REF. STRUCTURAL EXISTING STEEL COLUMN TO REMAIN; REF. STRUCTURAL EXISTING STEEL CANOPY TO REMAIN EXISTING IRRIGATION SYSTEM TO BE RELOCATED PER IMPACT OF NEW CANOPY FOOTINGS 7 JAN 7 jdf Date: Drawn By: Project Number: 627 L-3 Crestview Aerospace Revisions Building 5 Entry Renovation 5486 FAIRCHILD ROAD CRESTVIEW, FLORIDA FOR BID XX XXX 6 DEMOLITION PLAN ALE: /4" = '-0" 2' ' 0 2' 4' DEMOLITION PLAN D.0

3 LIFE SAFETY PLAN SYMBOLS LEGEND PRIMARY PATH OF TRAVEL TO EGRESS LOCATION OF EXISTING 2 HOUR RATED FIRE BARRIER LOCATION OF EXIT SIGNS (COORDINATE W/ ELECTRICAL DRAWINGS) FE SEMI-RECESSED FIRE EXTINGUISHER CABINET (VERIFY LOCATIONS WITH LOCAL FIRE MARSHALL) 20 TOTAL OCCUPANT LOAD (TOTAL BUSINESS) F- OCCUPANCY B OCCUPANCY SNACK B OCCUPANCY B OCCUPANCY SNACK PEPSI CHANGE EXIST'G REF REF WOMEN 06 SECONDARY EXIT ACCESS PATH - 8'-0" ICE MACH MEN 07 BREAK ROOM OCUPANTS COMMON PATH OF TRAVEL - 74'-0" JAN 08 IW PRIMARY EXIT ACCESS PATH - 6'-0" LAN 09 STORAGE 02 MECHANICAL 03 PEPSI COKE HALLWAY TO PRODUCTION LOBBY JAN 7 jdf Date: Drawn By: Project Number: 627 L-3 Crestview Aerospace Revisions Building 5 Entry Renovation 5486 FAIRCHILD ROAD CRESTVIEW, FLORIDA FOR BID XX XXX 6 LIFE SAFETY PLAN ALE: /4" = '-0" 2' ' 0 2' 4' LIFE SAFETY PLAN A.0

4 ACCESSORIES BC BASE CABINETS; LAMINATE FINISH DF STANDARD DRINKING FOUNTAIN w/ BOTTLE FILLER (HI-LOW-ELKAY EZH20) GB36 36" STAINLESS STEEL GRAB BAR; BOBRICK B GB42 42" STAINLESS STEEL GRAB BAR; BOBRICK B HCDF ADA ACCESSIBLE DRINKING FOUNTAIN (HI-LOW - ELKAY) HCWC ADA ACCESSIBLE WATER CLOSET; WALL MOUNTED HCLAV ADA ACCESSIBLE LAVATORY HD ELECTRIC HAND DRYER; EXCEL XCELERATOR XL-W LAV LAVATORY UNIT MR FRAMED MIRROR (2'-4"wX3'h) MR2 ADA MIRROR MS MOP SINK PCT REF T SD2 SN SS2 TC TT2 UR WC NEW 2.0 cuft MICROWAVE LOCATIONS (4) GE SERIES JES205DNBB - BLACK PLASTIC LAMINATE COUNTER TOP NEW 24.9 cuft REFRIGERATOR GE SERIES GDE25EGKBB - BLACK SEAT COVER DISPENSER; BOBRICK B-22 SOLID SURFACE COUNTER TOP SOAP DISPENSER (WALL MOUNTED); BOBRICK B-2 SANITARY NAPKIN DISPOSAL UNIT; BOBRICK B-254 STAINLESS STEEL SINK (2 BOWL) TOILET PARTITION (CEILING MOUNTED) SOLID PHENOLIC TRASH CHUTE; BOBRICK B-529 DOUBLE TOILET TISSUE DISPENSER; BOBRICK B-274 STANDARD URINAL STANDARD WATER CLOSET; WALL MOUNTED SNACK SNACK PEPSI IW IW NO WORK IN THIS AREA CHANGE EXIST'G REF REF 6'-8" 06A WOMEN 06 8'-2" IW5 5'-0" '-8" ICE MACH IW3 IW IW2 IW4 IW3. LAV LAV MR 3'-6" MR TC SD2 HD MR TC SD2 T LAV HD 2'-6" 9 8'-5" A6.0 8 MIRR 3' " 3'-5" 3'-5" 7'-" WC TT2 TT2 WC 6'-0" WC TT2 SN SD2 MR2 HCWC SN TT2 SN SN HCLAV GB36 GB42 EW SS2 SD2 MR2 HCLAV GB36 GB42 A6.0 7 WC TT2 TT2 WC WC TT2 HCWC TT2 BC PCT ZURN Z204 ND-6 BACK TO BACK CARRIER HD 6'-6" DF HCDF 24" MIN. WALLS TO EXTEND TO UNDERSIDE OF DECK ABOVE IW3. 8 A6.0 9 SIM MEN 07 BREAK ROOM 05 07A IW4 T LAV TC LAV TC LAV MR SD 8'-4" MR SD MR MS IW3. HD 08A JAN 08 2'-0" 4'-9" IW4 UR UR UR UR 09A LAN 09 EXISTING SERVER TO REMAIN NEW WATER HEATER 03A STORAGE 02 MECHANICAL 03 IW PEPSI COKE 05A HALLWAY TO PRODUCTION LOBBY '-6" 3'-9" 7'-0" IW 4'-3" '-3" 02A IW 0A 4'-6 2 " 9'-" IW IW IW 4'-6 2 " 5'-6" 7'-4" 2'-4" HVAC UNIT; REF. MECHANICAL SEE SHEET A6.0FOR ARCHITECTURAL DETAILS; SEE STRUCTURAL DRAWING FOR FURTHER DETAILS 7 JAN 7 jdf Date: Drawn By: Project Number: 627 L-3 Crestview Aerospace Revisions Building 5 Entry Renovation 5486 FAIRCHILD ROAD CRESTVIEW, FLORIDA FOR BID XX XXX 6 FLOOR PLAN ALE: /4" = '-0" 2' ' 0 2' 4' FLOOR PLAN A.

5 CEILING FINISH LEGEND 2"x2"x/4" STEEL ANGLE 48" O.C. 3"x3"x/4" STEEL ANGLE SUSPENDED FROM STRUCTURE ABOVE CEILING MOUNTED TOILET PARTITION ACOUSTICAL CEILING TILE 24" x 48" ACOUSTICAL CEILING TILE; ARMSTRONG #535 CIRRUS, WHITE; PRELUDE ML 5/6 EXPOSED TEE, WHITE NOTE: COORDINATE LIGHTING WITH ELECTRICAL PLANS. COORDINATE MECHANICAL WITH MECHANICAL PLANS. 2 CEILING BLOCKING DETAIL ALE: " = '-0".5'.25' 0.5' ' NO WORK IN THIS AREA 3'-6" 3'-5" 3'-5" WOMEN 06 + A.F.F. 7'-0 2 " 6'-0 2 " 6'-0 2 " 7'-0 2 " 3'-5" 3'-5" 3'-6" BREAK ROOM 05 + A.F.F. + A.F.F. MEN 07 3x3x/4" STEEL ANGLE IN CEILING FRAMING FOR CEILING HUNG PARTITION SYSTEM SEE DETAIL 2/A.2 LAN JAN A.F.F. + A.F.F. + A.F.F. STORAGE 02 + A.F.F. MECHANICAL 03 HALLWAY TO PRODUCTION LOBBY 0 + A.F.F A.F.F. SECTION OF CEILING TO BE REPAIRED TO MATCH EXISTING FRAME & TILE PATTERN WITHIN STORAGE / SPACE 7 JAN 7 jdf Date: Drawn By: Project Number: 627 L-3 Crestview Aerospace Revisions Building 5 Entry Renovation 5486 FAIRCHILD ROAD CRESTVIEW, FLORIDA FOR BID XX XXX 6 REFLECTED CEILING PLAN ALE: /4" = '-0" 4' 2' 0 4' 8' REFLECTED CEILING PLAN A.2

6 STANDARD CLEARANCES and MOUNTING HEIGHTS WALL TYPE NOTES SEE FLOOR PLANS FOR WALL INSULATION LOCATIONS SEE PARTITION TYPES FOR REQUIRED WALL INSULATION. PROVIDE CEMENT BACKER BOARD FOR ALL WALL TILE INSTALLATION. LOCATE ALL FIRE EXTINGUISHERS PER CODE. 5. USE 5/8" GYP BOARD ON ALL WALLS PARTITIONS. 6. PROVIDE CONTINIOUS FIBERGLASS PAPER BACKED INSULATION & SEALANT FOR ALL BATHROOM AND PLUMBING WALLS AND ABOVE CEILINGS WHERE PLUMBING AND FANS OCCUR. (SEE FLOOR PLANS FOR LOCATIONS) 7. USE 5/8" TYPE "X" DENSGLASS GOLD AS SUBSTRATE AT EXTERIOR WALLS AS REQUIRED (TYP) 8. ALL WALLS TO RECEIVE BASE AS HEDULED. '-5" 2'-7" WALL TYPES EXTERIOR WALL TYPES H.C. TOILET LOCATION & CLEARANCE ANSI FIG & SIDE WALL GRAB BAR ANSI FIG. 604, & (A) & (B) REAR GRAB BAR ANSI H.C. URINAL PAPER/TRASH DISPOSAL EXTERIOR WALL TYPE EW METAL WALL PANEL MATCH EXISTING 3 5/8" METAL 6" O.C. BATT INSULATION LAYER 5/8" GYP. BOARD EXTERIOR WALL EW 3'-4" 2'-0" H.C. LAV & MIRROR 3'-0" H.C. WATER FOUNTAIN LAV MOUNTING HEIGHTS MANEUVERING CLEARANCE ANSI FIG (g) 4'-0" FIRE EXT. BRACKET MANEUVERING CLEARANCE ANSI FIG (f) 2'- 6 5 " 4'-0" FIRE EXT. CABINET MANEUVERING CLEARANCE ANSI FIG (b) 2 6" TYPICAL WALL DETAIL ALE: 3/4" = '-0" 2'-0" MAX. ACT CEILING METAL STUD WALL GYPBOARD FINISH 4" RUBBER BASE NEW 3000psi CONCRETE VAPOR BARRIER ATTACHED TO EXISTING COMPACTED FILL; TREAT SOIL FOR TERMITE NEW PLUMBING EXISTING SLAB EXISTING VAPOR BARRIER EXISTING FILL WALL TYPES IW IW2 IW3 IW3. IW4 WALL WALL WALL MOISTURE RESISTANT GYP BOARD IN LIEU OF GYP BOARD WALL WALL TYPE IW LAYER 5/8" GYP. BOARD 3 5/8" METAL 6" O.C. BATT INSULATION LAYER 5/8" GYP. BOARD WALL TYPE IW2 LAYER MOISTURE RESISTANT 5/8" GYP. BOARD AND/OR CEMENT BACKER WALL BOARD 3 5/8" METAL 6" O.C. BATT INSULATION LAYER 5/8" GYP. BOARD WALL TYPE IW3 LAYER MOISTURE RESISTANT 5/8" GYP. BOARD AND/OR CEMENT BACKER WALL BOARD w/ WALL TILE 3 5/8" METAL 6" O.C. BATT INSULATION LAYER 5/8" GYP. BOARD WALL TYPE IW4 LAYER MOISTURE RESISTANT 5/8" GYP. BOARD AND/OR CEMENT BACKER WALL BOARD w/ WALL TILE EXISTING METAL STUD WALL LAYER 5/8" GYP. BOARD WALL TYPE IW5 LAYER MOISTURE RESISTANT 5/8" GYP. BOARD AND/OR CEMENT BACKER WALL BOARD w/ WALL TILE 3 5/8" METAL 6" O.C. 7 JAN 7 jdf Date: Drawn By: Project Number: 627 L-3 Crestview Aerospace Revisions Building 5 Entry Renovation 5486 FAIRCHILD ROAD CRESTVIEW, FLORIDA FOR BID XX XXX 6 BATT INSULATION 3 5/8" METAL 6" O.C. MANEUVERING CLEARANCE ANSI FIG (e) MANEUVERING CLEARANCE ANSI FIG (c) MANEUVERING CLEARANCE ANSI FIG (d) MANEUVERING CLEARANCE ANSI FIG (a) SLAB REPAIR DETAIL ALE: /2" = '-0" IW5 IW6 WALL WALL LAYER MOISTURE RESISTANT 5/8" GYP. BOARD AND/OR CEMENT BACKER WALL BOARD w/ WALL TILE WALL TYPE IW6 LAYER MOISTURE RESISTANT 5/8" GYP. BOARD AND/OR CEMENT BACKER WALL BOARD w/ WALL TILE 3 5/8" METAL 6" O.C. BATT INSULATION 3 5/8" METAL 6" O.C. LAYER MOISTURE RESISTANT 5/8" GYP. BOARD CLEARANCES and MOUNTING HEIGHTS, WALL TYPES & DETAILS A.3

7 METAL 6" O.C. BATT INSULATION ABBREVIATIONS GENERAL EXP FD FE - EXPOSED - FLOOR DRAIN - FIRE EXTINGUISHER FINISH HEDULE NO. ROOM NAME 0 LOBBY 02 STORAGE FLOOR TILE VCT WALL MAT'L GB GB FINISH BASE RB RB CEILING FINISH ACT ACT HT REMARKS METAL STUD HEADER 5/8" GYP BOARD SHEATHING SEALANT METAL DOOR FRAME 2x WOOD BUCK DOOR AS HEDULED DOOR FRAME BEYOND PEEL N STICK OPENING EXISTING EXTERIOR METAL PANEL /2" SEALANT & BACKER ROD PRE-FIN. METAL HEAD FLASHING HOLLOW METAL FRAME AS HEDULED DOOR AS HEDULED MFR TH FLOORING EPOXY TILE VCT BASE RB WALLS CB FE GB TL2 - MANUFACTURER - THRESHOLD - EPOXY FLOOR COATING SYSTEM; SHERWIN WILLIAMS ARMORSEAL 800; STANDARD COLOR BY OWNER - COMMERCIAL GRADE PORCELAIN TILE (2x24); WOOD GRAIN - VINYL COMPOSITION TILE; COLOR BY OWNER - 4" RUBBER BASE; COLOR BY OWNER - CEMENT BACKER BOARD BEHIND WALL TILE - SEMI-RECESSED ALUMINUM FIRE EXTINGUISHER CABINET - 5 8" GYPSUM BOARD - LATEX PAINT - COMMERCIAL GRADE CERAMIC WALL TILE; INSTALL TILE WAINOTING UP TO 72" A.F.F., w/ BULLNOSE CAP HALL TO PRODUCTION A 03A MECHANICAL BREAK ROOM 06 WOMEN 08 MEN JANITOR DOOR HEDULE DOOR NO. SIZE 3'-0" x 7'-0" 3'-0" x 7'-0" TYPE MAT'L FRAME HDW MAT'L HEAD JAMB SILL 0A 6'-0" x 7'-0" A METAL HW-2 HM /A6.0 2/A6.0 3/A6.0 C VCT TILE VCT EPOXY EPOXY EPOXY C WOOD HW-3 HM 4/A6.0 5/A6.0 6/A6.0 WOOD HW-3 GB GB GB GB/TL2 GB/TL2 HM RB RB RB EPOXY EPOXY ACT ACT ACT ACT ACT 09 LAN ROOM VCT GB RB ACT GB EPOXY ACT 4/A6.0 5/A6.0 6/A6.0 FIRE RATING INTEGRATED 4" EPOXY WALL BASE INTEGRATED 4" EPOXY WALL BASE INTEGRATED 4" EPOXY WALL BASE REMARKS CEILINGS ACT GYP DOORS - LAY-IN ACOUSTICAL CEILING TILE 2'x4' - 5/8" GYP BOARD; PRIMED & PAINTED 05A 06A 6'-0" x 7'-0" 3'-0" x 7'-0" B C 07A 3'-0" x 7'-0" C 08A 3'-0" x 7'-0" C 09A 3'-0" x 7'-0" C WOOD WOOD WOOD WOOD WOOD HW- HW- HW- HW-3 HW-3 HM HM HM HM HM 4/A6.0 5/A6.0 6/A6.0 4/A6.0 5/A6.0 6/A6.0 4/A6.0 5/A6.0 6/A6.0 4/A6.0 5/A6.0 6/A6.0 4/A6.0 5/A6.0 6/A HEAD DETAIL ALE: 3" = '-0" METAL 6" O.C. BATT INSULATION METAL STUD JAMB 5/8" GYP BOARD SHEATHING SEALANT METAL DOOR FRAME 2x WOOD BUCK DOOR AS HEDULED DOOR FRAME BEYOND JAMB DETAIL ALE: 3" = '-0" PEEL N STICK OPENING EXISTING EXTERIOR METAL PANEL 2 HEAD DETAIL ALE: 3" = '-0" /2" SEALANT & BACKER ROD PRE-FIN. METAL JAMB FLASHING HOLLOW METAL FRAME AS HEDULED DOOR AS HEDULED JAMB DETAIL ALE: 3" = '-0" ALUM HM WOOD HW- HW-2 HW-3 - ALUMINUM STORE FRONT SYSTEM - HOLLOW METAL FRAME; PRIME & PAINT - SOLID CORE WOOD DOOR; PRE-FINISHED STAINED BIRCH HARDWARE HEDULE 3 HINGES, FLOOR STOP, PUSH/PULL BAR, CLOSER. 3 HINGES, FLOOR STOP, EXIT DEVICE, LATCH, CLOSER, WEATHER-STRIPPING, THRESHOLD. 3 HINGES, FLOOR STOP, STORAGE SET. FINISH HEDULE NOTES. SEE REFLECTED CEILING PLAN AND DETAILS FOR EXACT CEILING HEIGHT LOCATIONS. 2. ANTI-FRACTURE MAT SHALL BE INSTALLED UNDER ALL FLOOR TILE SURFACES. 3. CONCRETE BACKER BOARD SHALL BE INSTALLED BEHIND ALL WALL TILE. ELEVATIONS 7 8 ELEVATION ALE: /4" = '-0" HCDF DF MR2 ICE MACHINE PCT ELEVATION ALE: /4" = '-0" BC * REFERENCE FLOOR PLAN FOR ADDITIONAL NOTES SS2 DOOR TYPES TYPE A INSULATED HOLLOW METAL DOOR PRIME & PAINT VISION PANEL TEMPERED GLAZING 3'-0" 6'-0" 24" DEEP 3'-0" '-6" '-8" 6'-2" TYPE B SOLID CORE WOOD DOOR PRE-FIN. STAINED TEMPERED GLAZING TYPE C SOLID CORE WOOD DOOR PRE-FIN. STAINED EXTERIOR DETAILS EXTERIOR CANOPY SECTION ALE: /4" = '-0" * PRIME & PAINT ALL EXPOSED STEEL ALE: /4" = '-0" STANDING SEAM METAL ROOF METAL FLASHING EXISTING BULDING 5 METAL ROOF DECK STEEL TUBING; SEE STRUCTURAL STEEL COLUMN; SEE STRUCTURAL STEEL "C" BRACE; SEE STRUCTURAL; PRIME 7 JAN 7 jdf Date: Drawn By: Project Number: 627 L-3 Crestview Aerospace Revisions Building 5 Entry Renovation 5486 FAIRCHILD ROAD CRESTVIEW, FLORIDA FOR BID XX XXX 6 6 DOOR FRAME BEYOND DOOR AS HEDULED SILL DETAIL ALE: 3" = '-0" 3 DOOR FRAME BEYOND DOOR AS HEDULED ALUMINUM SILL SET IN BED OF SEALANT SILL DETAIL ALE: 3" = '-0" 9 PD MR MR MR ELEVATION ALE: /4" = '-0" PD 3'-0" 6'-0" WALL MOUNTED MIRROR P.T. 2x8 BLOCKING P.T. 2x0 VANITY FRAMING SOLID SURFACE VANITY DETAIL 0 ALE: /2" = '-0" 2'-0" STANDING SEAM METAL ROOF EXTERIOR CANOPY ELEVATION 2 ALE: /4" = '-0" METAL FLASHING STEEL TUBING; SEE STRUCTURAL STEEL COLUMN; SEE STRUCTURAL STEEL "C" BRACE; SEE STRUCTURAL * PRIME & PAINT ALL EXPOSED STEEL HEDULES, ELEVATIONS & DETAILS A6.0

8

9

10

11

12

13 OSV FDM RM 504 ELEC. RM MECH. Conf. BREAK ROOM SOUTH CUBICLE AREA MECH CONFERENCE ROOM WOMEN MEN MECH I.T. LOBBY WAREOUSE (H & S) MECH NORTH CUBICLE AREA YATES ENGINEERING SOLUTIONS ELECTRICAL LEGEND, NOTES & POWER RISER DIAGRAM E0.0

14 ELECTRICAL DEMOLITION PLAN ALE: /4" = '-0" DEMOLITION NOTES YATES ENGINEERING SOLUTIONS ELECTRICAL DEMOLITION PLAN E.0

15 SNACK SNACK PEPSI CHANGE PEPSI REF COKE REF BREAK ROOM 0 ICE MACH JANITOR 0 WOMEN 0 MEN 0 STORAGE 0 LOBBY 0 NEW WORK POWER & SIGNAL PLAN ALE: /4" = '-0" YATES ENGINEERING SOLUTIONS NEW WORK POWER & SIGNAL PLAN E2.0

16 SNACK SNACK PEPSI CHANGE PEPSI REF COKE REF BREAK ROOM 0 ICE MACH JANITOR 0 WOMEN 0 MEN 0 LOBBY 0 STORAGE 0 NEW WORK LIGHTING PLAN ALE: /4" = '-0" YATES ENGINEERING SOLUTIONS NEW WORK LIGHTING PLAN E2.02