THIS TO CERTIFY THAT. Firetek Panel. Structure - Structural Reliability

Size: px
Start display at page:

Download "THIS TO CERTIFY THAT. Firetek Panel. Structure - Structural Reliability"

Transcription

1 Certification Body: ABN: JAS-ANZ Accreditation No. Z AK PO Box 7144, Sippy Downs Qld (07) Certificate Holder: Building Solutions Pty Ltd ABN: Action Street Noosaville Qld 4566 Ph: Type and/or use of product: Pre-fabricated insulated roof panel. Performance Requirement(s) Deemed-to-Satisfy Provision(s): State or territory variation(s): Volume One BP1.1(a)(b) (i)(ii)(iii) CP2 CP4 G5 J C1.10(a) (ii)(ix) THIS TO CERTIFY THAT Firetek Panel Certificate number: CM40211 Description of product: A pre-fabricated Structural Insulated Panel (SIP) with a Fire Resistant Polyisocyanurate (PIR) core tested up to but not exceeding Bushfire Attack Level 40. The Firetek Panel is pre-finished in Colorbond Steel sheeting bonded to both sides of a profiled Fire Resistant Polyisocyanurate (PIR) core. Available panel thickness: 85mm, 105mm, 125mm and 150mm Spans up to 9 metres and Cantilevers up to 3 metres COMPLIES WITH THE FOLLOWING BCA PROVISIONS AND STATE OR TERRITORY VARIATION(S) BCA 2016 Structure - Structural Reliability Fire Resistance - Spread of Fire Fire Resistance - Materials and Assemblies Construction in Bushfire prone areas-contributes to compliance subject to Condition and Limitation 2 Energy efficiency contributes to compliance subject to Condition and Limitation 3 Volume Two P2.1.1(a)(b) (i)(ii)(iii) Structure - Structural Stability and Resistance P2.3.4 Bushfire Areas (BAL 40) Fire Hazard properties Bushfire Areas- Contributes to compliance subject to Condition and Limitation 2 Not applicable to this product Energy efficiency contributes to compliance subject to Condition and Limitation 3 NSW, Qld, SA, TAS VIC John Thorpe - CMI Don Grehan Unrestricted Building Certifier Date of issue: 22/11/2017 Date of expiry: 22/11/2020 Certificate number: CM40211 This certificate is only valid when reproduced in its entirety. Page 1 of 7

2 SUBJECT TO THE FOLLOWING LIMITATIONS AND CONDITIONS AND THE PRODUCT TECHNICAL DATA IN APPENDIX A AND EVALUATION STATEMENTS IN APPENDIX B Limitations and conditions: 1. All design and fixing specifications and installations must be completed in accordance with Firetek Panel Design and Detailing Manual Version and AS1562.1:1992 (Amendment 3) Design and Installation of Sheet Roofing. 2. Suitable for use in bushfire construction for BAL not exceeding BAL This Certificate is issued based on the evidence of compliance as detailed herein. Any deviation from the specifications contained in this Certificate is outside of the document's scope and the installation of the certified product/system will not be covered by the CodeMark Certification. This may result in the product being classified as a non-conforming building product/system. Building classification/s: Class 1,2,3,4,5,6,7,8,9 & 10 Scope of certification: The CodeMark Scheme is a building product certification scheme. The rules of the Scheme are available at the ABCB website This Certificate of Conformity is to confirm that the relevant requirements of the Building Code of Australia (BCA) as claimed against have been met. The responsibility for the product performance and its fitness for the intended use remain with the certificate holder. The certification is not transferrable to a manufacturer not listed on Appendix A of this certificate. Disclaimer: The Scheme Owner, Scheme Administrator and Scheme Accreditation Body do not make any representations, warranties or guarantees, and accept no legal liability whatsoever arising from or connected to, the accuracy, reliability, currency or completeness of any material contained within this certificate; and the Scheme Owner, Scheme Administrator and Scheme Accreditation Body disclaim to the extent permitted by law, all liability (including negligence) for claims of losses, expenses, damages and costs arising as a result of the use of the product(s) referred to in this certificate. Certificate number: CM40211 This certificate is only valid when reproduced in its entirety. Page 2 of 7

3 APPENDIX A PRODUCT TECHNICAL DATA A1 Type and intended use of product As per page one A2 Description of product Firetek CORRUGATED Panel Profile Tested and Certified for BAL40 Bushfire Attach Level. PIR insulation core. Suitable for roof pitches down to 5 o. Panel thickness range from 85mm to 150mm. Corrugated profile roof & ceiling sheet. Available in a range of Colorbond colours. Can be customised to suit specific requirements. Firetek TRIMDEK Panel Profile Tested and Certified for BAL40 Bushfire Attach Level. PIR insulation core. Suitable for roof pitches down to 2 o. Panel thickness range from 105mm to 150mm. Trimdek profile roof sheet & corrugated ceiling sheet. Available in a range of Colorbond colours. Can be customised to suit specific requirements. Source: Certificate Holder Certificate number: CM40211 This certificate is only valid when reproduced in its entirety. Page 3 of 7

4 A3 Product specification EARLY FIRE HAZARD AS/NZS :1999 INDEX RESULT Ignitability 0 Spread of Flame 0 Heat Evolved 0 Smoke Developed 5 BUSHFIRE ATTACK LEVEL ASSESSMENT AS 3959:2009 INDEX RESULT (AS Construction in Bushfire Prone Areas) BAL Rating Up to 40 FIXING OPTIONS Main Fixing Screws Hex Seal Class 4 + Cyclonic Washer: 14G Metal Tek or T17 Stitching Screws Hex Seal Class 4: T x 25 Rivets 73AS54 or 73AS43 Firetek CORRUGATED Panel Specifications PANEL THICKNESS IS MEASURED FROM THE TOP RIB TO THE BOTTOM RIB Cover Width Insulation Core Material Length Thermal Conductivity 762mm Fire Retardant, Ordered to Size 0.022W/mK Polyisocyanurate Foam Up to 24m (PIR) Top Sheet Finish Bottom Sheet Finish Sheet Material Typical Panel Weight 0.42BMT G550 Steel 85mm = 11.2kg/m2 105mm = 12kg/m2 125mm = 12.7kg/m2 150mm = 13.7kg/m2 Thermal PERFORMANCE PROPERTIES CORRUGATED TOP SHEET PROFILE 85mm Panel 105mm Panel 125mm Panel 150mm Panel R 3.4 R 4.4 R 5.4 R 6.6 Certificate number: CM40211 This certificate is only valid when reproduced in its entirety. Page 4 of 7

5 Ritek Firetek TRIMDEK Panel Specifications PANEL THICKNESS IS MEASURED FROM THE TOP RIB TO THE BOTTOM RIB Cover Width Insulation Core Material Length Thermal Conductivity 762mm Fire Retardant, Ordered to Size 0.022W/mK Polyisocyanurate Foam Up to 24m (PIR) A4 Manufacturer and manufacturing plant(s) Top Sheet Finish Bottom Sheet Finish Sheet Material Typical Panel Weight 0.42BMT G550 Steel Thermal PERFORMANCE PROPERTIES TRIMDEK TOP SHEET PROFILE 105mm Panel 125mm Panel 150mm Panel R 3.5 R 4.4 R 5.6 This field is voluntary. For more information, please contact Certificate Holder. A5 Installation requirements All design and fixing specifications and installations must be completed in accordance with Ritek Design & Detailing Manual and Ritek Firetek Roof Panel Version Roofs are designed in accordance with: i. AS1170:2002 Part 1 (Amendment 2) and AS1170:2011 Part 2 Wind Loading Code; ii. AS1562.1:1992 (Amendment 3) Design and Installation of Sheet Roofing; iii. AS4055:2012 Wind Loads for Housing; iv. AS4040:1992.2/3 Low-High-Low Cyclic Strength Testing. 105mm = 11.5kg/m2 125mm = 12.3kg/m2 150mm = 13.3kg/m2 The Firetek Panel Design and Detailing Manual Version provides details of compliant installation against this Certificate in its entirety. This includes the products Weatherproofing, Fire Hazard Properties, Bushfire Prone Areas and Thermal Performance Certificate number: CM40211 This certificate is only valid when reproduced in its entirety. Page 5 of 7

6 A6 Other relevant technical data ACOUSTIC PERFORMANCE CORRUGATED TOP SHEET PROFILE 85mm Panel 105mm Panel 125mm Panel 150mm Panel R w R w + C tr R w R w + C tr R w R w + C tr R w R w + C tr 23dB 15dB 23dB 15dB 23dB 18dB 23dB 18dB ACOUSTIC PERFORMANCE TRIMDEK TOP SHEET PROFILE 105mm Panel 125mm Panel 150mm Panel R w R w + C tr R w R w + C tr R w R w + C tr 23dB 15dB 23dB 18dB 23dB 18dB Certificate number: CM40211 This certificate is only valid when reproduced in its entirety. Page 6 of 7

7 APPENDIX B EVALUATION STATEMENTS B1 Evaluation methods 1. Structural Provision A2.2 (a) (i) & (iii) and (b); and (a) (i) & (iii). Reports from NATA accredited test laboratories and certificates from Professional Engineers. 2. Thermal Provision A2.2 (a) (i) & (iii) and (b); and (a) (i) & (iii). Reports from accredited test laboratories and certificates from Professional Engineers 3. Fire Safety Provision A2.2 (a) (i) & (iii) and (a) (i) & (iii). Reports from NATA accredited test laboratories and certificates from Professional Engineer. B2 Reports 1. BRANZ Assessment Report FAR 3781, Assessment of construction methods. BCA Volumes 1 and 2 Class 1a, 2, 3 and 9 up to two stories type b construction and Class 5,6,7 & 8 up to 3 storeys Type B & C. 2. Construction Relates to the Firetek Panel. Testing to confirm the performance of the roof panels to BCA Volumes 1 and 2 for Class 2, 3 & 9 buildings up to 2 stories Type B Construction. 3. Class 5,6,7 & 8 up to 3 storeys Type B & C Construction. 4. BRANZ fire test certificate 473 AS ISO 9705 Group number 1 Smoke growth rate index (SMOGRA rc) < 100. Compliance to Fire resistance. 5. BRANZ Fire Assessment Report FAR 4421 dated 21/04/2017 Assessment of Ritek roof systems for compliance with the NCC Compliance to Fire resistance. 6. AWTA NATA Accreditation No Test Report No CQ Dated 05/03/2012 In accordance with AS Compliance to Fire resistance. 7. Exova Warrington Fire Test Report SFC 26709A-01 NATA accreditation number 3277, testing to AS BAL 40. Compliance to Fire resistance. 8. James M Fricker Test Report 128d testing to AS/NZS :2002. Demonstrate compliance to Thermal resistance. The Certificate Holder has chosen not to make the above evidence of compliance publicly available, due to the documents being considered commercial in confidence. Certificate number: CM40211 This certificate is only valid when reproduced in its entirety. Page 7 of 7