1 Installation Instructions/Operation and Maintenance Manual Models: All Models Contact Information Table of Contents: Safety Precautions... 2 Product Information... 2 Installation Instructions... 6 Deployment Instructions... 9 Parts List...10 Inspection and Maintenance...12 Warranty Registration Form...14 Warranty Certificate...15 Mail PS Flood Barriers 1150 South 48th Street Grand Forks, ND Local Phone Toll Free Phone Website psfloodbarriers.com 4psinfo@psindustries.com Hours of Operation 8 A.M. to 5 P.M. CT Monday Friday IMPORTANT! Read entire Instruction and Operations Manual to become familiar with the product. NOTICE This product is a flood protection product. The effectiveness of the product is directly related to the proper installation and operation of this product. Failure to properly maintain this product will affect performance. Publication Notice This manual has been compiled and published covering the latest product descriptions and specifications. The contents of this manual and the specifications of this product are subject to change without notice. PS Flood Barriers reserves the right to make changes without notice in the specifications and materials contained herein and shall not be responsible for any damages (including consequential) caused by reliance on the materials presented, including but not limited to typographical and other errors relating to the publication. PS Flood Barriers and/or its respective suppliers may make improvements and/or changes in the product(s)/ service(s) offered and/or the program(s) at any time without notice. Retain this manual for future reference. If you would like to download a copy of this manual, please go to psfloodbarriers.com Product registration is an essential step to protecting your product, register Online at psindustries.com/contact/register-your-product/ EzDam PS INDUSTRIES INCORPORATED All Rights Reserved. PN B 1

2 Safety Precautions The following icons are used throughout this Manual. DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderated injury. NOTICE Indicates manufacturer s statement of additional information. IMPORTANT! Indicates a required action. CRITICAL Indicates a vital component to product performance. Product Information NOTICE Unauthorized modification of or to the Product voids this Limited Warranty. Authorized modifications, received in writing from PS INDUSTRIES INCORPORATED, as long as the modification is accomplished in strict accordance with PS INDUSTRIES INCORPORATED s instructions, does not void warranty. To request product modifications contact PS INDUSTRIES INCORPORATED, 1150 S. 48th Street, Grand Forks, ND 58201, phone , 4psinfo@psindustries.com I. General Information A. This manual contains information regarding installation, operation, and maintenance of the PS Flood Barriers EzDam Floor Barrier assemblies. B. PS Flood Barriers recommends that the owner implement a regular maintenance program to inspect the EzDam Floor Barrier assemblies as necessary. C. Conduct Inspection and Maintenance activities as described in this Operation and Maintenance Manual, at a minimum, annually and seasonally if seasonal flood conditions exist, prior to the flood season. This may require the replacement of gaskets, sealants, anchors, and accounting for all of the latching devices. D. EzDam provides flood protection for well-maintained buildings that are watertight except for their doorways or a similar opening. This product is equipped with compressible seals, which are not dependent on inflation devices. E. EzDam is suitable for structures that are constructed of concrete, brick, sealed stone, and other watertight materials in good condition. F. EzDam can work in wooden structures if they are fully encircled by a watertight concrete foundation that rises above the height of your EzDam. 2 WARNING THIS IS A FLOOD PROTECTION BARRIER; NEVER UNLATCH OR DISASSEMBLE DURING ANY FLOOD CONDITIONS AS WATER LEAKAGE WILL OCCUR AND YOU MAY NOT BE ABLE TO RESEAL THE BARRIER. II. Operation Guidelines A. Operation in a manner other than intended could result in damage or less than acceptable performance at time of need, for which the manufacturer will not be held responsible. B. Protect all gaskets and hardware. Always consult original Approved for Construction drawings for all installation dimensions, details, hardware and specifications. C. Ensure PS Flood Barriers EzDam Floor Barrier is located near the required area for placement when needed, is deployed, and latched prior to flood waters reaching the opening. D. EzDam is not suitable for non-watertight structures such as wood framed houses with foundations lower than the height of your EzDam. E. If the walls of a structure are not watertight, EzDam will not provide adequate protection. F. For structures with basement windows or sunken/slanted outside cellar doorways contact PS Flood Barriers at or 4psinfo@psindustries.com. CRITICAL Always plan for potential leakage and condensation that can occur during flooding conditions. PS INDUSTRIES INCORPORATED All Rights Reserved. EzDam

3 Product Information III. Safety Precautions A. Ensure opening is clear of all obstructions or debris through entire travel of the door during operation. B. Do not force panels or components if they do not operate freely. C. Install only on surfaces capable of supporting all loading. D. If the water height exceeds the level of any panel penetrations or water protective design height, leakage will occur. IV. Storage Prior to Installation of Product A. Store materials in a dry, ventilated location. If outdoor storage is required, block materials and tarp in a tent-like arrangement, elevated above the product with open sides to allow airflow. V. Installation Site Preparation NOTICE Before starting site preparation and installation of the EzDam Floor Barrier, read the entire Operation and Maintenance Manual and review all installation instructions thoroughly. A. Clear work area of any debris. B. Ensure you have the necessary tools available. C. Obtained all required permits. DANGER All water pressure, impact, and operating loads are transfered to the building structure. Building structural design and capacity to accept loads from flood barriers, as well as, evaluation of loads to structure is the responsibility of the owner. VI. Operation A. The PS Flood Barriers EzDam is a specially designed Flood Barrier capable of providing flood protection. The EzDam is specially manufactured to meet the opening dimensions and Water Protective Height (WPH) of each customer s specific site requirements. B. Except as otherwise indicated, requirement for flood barriers, terminology, tolerances, standards or performance and workmanship are those specified as Type 2 Closures in Chapter 7, Section of the US Army Corps of Engineers, EP , 15 December C. These Type 2 Flood Closures/Barriers shall form essentially dry barriers of seals, allowing only slight seepage during the hydrostatic pressure conditions of flooding to the Regulatory Flood Datum (RFD) or the Design Flood Elevation (DFE). Seepage amounts will vary with conditions encountered. This issue should be addressed by the design professional and usage of sump or bilge type pumps should be used to off set potential water build up. D. DUE TO THE CUSTOM NATURE OF EACH EZDAM THEY DO NOT ALL LOOK NOR LATCH EXACTLY THE SAME. REFER TO THIS DOCUMENT AND APPROVED FOR CONSTRUCTION DRAWINGS FOR YOUR SPECIFIC INSTALLATION AND OPERATION. VII. Single EzDam Application A. The EzDam Flood Barrier is available in four sizes; Protective Opening Width: a. 36 Height b. 48 Height Protective Opening Width: a. 36 Height b. 48 Height B. Support mullions are not needed for the single EzDam application. VIII. Muti-Barrier EzDam Application A. In case where the width of an opening is larger than 52, multiple EzDam Flood Barriers may be installed end to end with a mullion system located where the EzDams meet. In these situations, please contact PS Flood Barriers at or ps4info@psindustries.com. EzDam PS INDUSTRIES INCORPORATED All Rights Reserved. 3

4 Product Information NOTE 1: Inventory carton to ensure all parts are present for assembly/installation. Refer to part list below. NOTE 2: This diagram is for all EzDam Models with 36" protection height. EzDam Part List (As shipped) Recommended Tools: 1. One (1) Electric Drill 2. One (1) Pencil 3. One (1) Level 4. One (1) Tape Measure DESCRIPTION QUANTITY EZD;JAMB ASSEMBLY KIT* 1 EZD;PANEL ASSEMBLY 1 SEALANT; POLYURETHANE, GRAY 1 EZD;INSTALLATION/O & M MANUAL 1 *Jamb Assembly Kit includes: 1. Two (2) Jambs 2. Eight (8) Anchors 3. One (1) Caulk smoothing tool 4. One (1) Masonry Drill Bit 4 PS INDUSTRIES INCORPORATED All Rights Reserved. EzDam

5 Product Information NOTE 1: Inventory carton to ensure all parts are present for assembly/installation. Refer to part list below. NOTE 2: This diagram is for all EzDam Models with 48" protection height. EzDam Part List (As shipped) Recommended Tools: 1. One (1) Electric Drill 2. One (1) Pencil 3. One (1) Level 4. One (1) Tape Measure DESCRIPTION QUANTITY EZD;JAMB ASSEMBLY KIT* 1 EZD;PANEL ASSEMBLY 1 SEALANT; POLYURETHANE, GRAY 1 EZD;INSTALLATION/O & M MANUAL 1 *Jamb Assembly Kit includes: 1. Two (2) Jambs 2. Two (2) Jamb Extensions 3. Eight (8) Anchors 4. Eight (8) Screws 5. One (1) Caulk smoothing tool 6. One (1) Masonry Drill Bit EzDam PS INDUSTRIES INCORPORATED All Rights Reserved. 5

6 Installation IX. EzDam Installation A. Following installations steps for 36" protective opening height, similar steps for 48" protective opening height. IMPORTANT! Follow included Anchor Manufacturer s technical data manual/installation instructions for installation requirements and proper installation procedures. STEP 1. Prepare your surface ensuring a flat, smooth, and free of cracks and defects to create a watertight seal with the wall and floor. IMPORTANT! Gasket contact area should be sound, flat/level and without blemish for best gasket performance. Floor cracks and expansion joints will cause extreme leakage. Permissible floor tolerance is +/- 1/ 16 per 10 foot length. STEP 2. Measure door/opening width. a. Determine the center point and mark onto existing floor surface. (See Install Reference) Step 2 Illustration EzDam Flood Barrier Install Reference OPENING WIDTH OPENING WIDTH 1/ 4 CENTERLINE JAMB LOCATION STEP 3. Determine distance between jamb location and centerline with tape measure. a. Mark jamb location onto existance floor surface. (See Illustration A) b. Using a level, transfer jamb location line onto wall surface. (See Illustration B) Step 3 Illustration A Step 3 Illustration B 1/ 4 Jamb location line Mark Jamb Location 1/ 4 6 PS INDUSTRIES INCORPORATED All Rights Reserved. EzDam

7 Installation STEP 4. Place jamb, with jamb cover facing up, on the marked location line. a. Mark anchor hole locations in jamb onto existing structure. Step 4 Illustration A Jamb Cover 1/ 4 Anchor Hole Locations 1 DETAIL A STEP 5. Set jamb aside and drill holes with supplied 1/ 4 masonry drill bit. Step 5 Illustration 4 STEP 6. Remove all dust and debris from anchor holes per Anchor Manufacturer's technical manual. EzDam PS INDUSTRIES INCORPORATED All Rights Reserved. 7

8 Installation STEP 7. Set jamb in place. a. Attach to existing structure using supplied anchors. Step 7 Illustration 2 1 STEP 8. After jamb is installed and anchored to wall. a. Apply urethane sealant to each side of jamb (full height) against existing structure to create a watertight joint. b. Place bead of urethane sealant around bottom of jamb, leaving outside edge of jamb open for drainage. c. Smooth to radius with supplied smoothing tool. d. Clean-up excess sealant that could interfere with the gasket. NOTICE Use care when applying sealants to keep work area clean. Step 8 Illustration A Step 8 Illustration B Urethane Sealant (Full Height) Urethane Sealant B No Urethane on this edge DETAIL B IMPORTANT! Leave outside edge of jamb base open for drainage. STEP 9. Installation of second jamb. a. Repeat Steps 2 through Steps 8 for opposite jamb. 8 PS INDUSTRIES INCORPORATED All Rights Reserved. EzDam

9 Deployment X. EzDam Deployment STEP 1. Set panel in place against jambs so that panel is centered on the opening. a. Apply forward pressure at bottom of panel with foot to ensure bottom of panel is seated properly, and that top and bottom latch hooks are engaged in jamb slots. *Vertical gaskets must contact jambs continuously from top to bottom before latches are tightened. Step 1 Illustration A Step 1 Illustration B TOP VIEW Continuous gasket contact STEP 2. Tighten latches securely and evenly using EZ Latching system (refer to Illustration). a. Visually inspect perimeter for continuous gasket contact. If necessary, loosen latches and adjust panel to correct any uneven or inconsistent gasket compression. Step 2 Illustration 15 Tighten knob to compress gaskets C Latch strap hooks into jamb slot DETAIL C EzDam PS INDUSTRIES INCORPORATED All Rights Reserved. 9

10 Replacement Parts List XI. Replacement Parts List for EzDam 36" Protection Height NOTE 1. The EzDam Flood Barrier Panel and Jambs are shipped fully assembled. Diagram is for part identification only. NOTE 2. This diagram is for all EzDam Models with 36" protection height. D E DETAIL E Hardware Variant for EZD ITEM # DESCRIPTION QTY PART # 5 EZD;PANEL STRUCTURE 44" EZD JAMB GASKET EZD BOTTOM SILL GASKET EZ DAM, TRAY EZ DAM, COVER Hardware Variant for EZD ITEM # DESCRIPTION QTY PART # 5 EZD;PANEL STRUCTURE 54" EZD JAMB GASKET EZD BOTTOM SILL GASKET EZ DAM, TRAY, LARGE EZ DAM, COVER, LARGE TO ORDER PARTS CONTACT PS FLOOD BARRIERS AT or 4psinfo@psindustries.com DETAIL D EzDam Parts List ITEM # DESCRIPTION QTY PART # 1 EZD;JAMB ASSEMBLY KIT EZD;EXTRUDED JAMB EZD;JAMB CAP SMALL RIVET;AL 1/8 X # ANCHOR;KWIKCON PFH 1/4X2-1/ STICK;WOOD 3/8"X1/16"X4-1/2" BIT;DRILL MASONRY 1/4X6" REFER TO HARDWARE VARIANT 6 EZD; LATCH PLATE REFER TO HARDWARE VARIANT 8 REFER TO HARDWARE VARIANT 9 EZD;LATCH STRAP SCREW;TRUSSPHMACH10-24X2-1/2SS SPACER;.5OD.192ID X SPACER;.3125OD.192ID X NUT;NYLOCK #10-24 SS WASHER;FLAT 1/4"SS KNOB;FOUR-ARM NYLON 1/4"-20" CAP;VINYL 1/4"-5/16" BLACK WASHER;NYLON, #10 SCREW REFER TO HARDWARE VARIANT 19 REFER TO HARDWARE VARIANT 20 SEALANT, POLYURETHANE, GRAY PS INDUSTRIES INCORPORATED All Rights Reserved. EzDam

11 Replacement Parts List XII. Replacement Parts List for EzDam 48" Protection Height NOTE 1. The EzDam Flood Barrier Panel and Jambs are shipped fully assembled. Diagram is for part identification only. NOTE 2. This diagram is for all EzDam Models with 48" protection height. F G DETAIL F EzDam DETAIL G Hardware Variant for EZD ITEM # DESCRIPTION QTY PART # 5 EZD;4FT PANEL ASSEMBLY 44" EZD JAMB GASKET EZD BOTTOM SILL GASKET EZ DAM, TRAY EZ DAM, COVER Hardware Variant for EZD ITEM # DESCRIPTION QTY PART # 5 EZD;4FT PANEL ASSEMBLY 54" EZD JAMB GASKET EZD BOTTOM SILL GASKET EZ DAM, TRAY, LARGE EZ DAM, COVER, LARGE TO ORDER PARTS CONTACT PS FLOOD BARRIERS AT or 4psinfo@psindustries.com PS INDUSTRIES INCORPORATED All Rights Reserved. EzDam Parts List ITEM # DESCRIPTION QTY PART # 1 EZD;JAMB ASSEMBLY KIT 4' EZD;EXTRUDED JAMB 4' EZD;EXTRUDED JAMB EXT. 4' EZD;JAMB CAP 4' RIVET;AL 1/8 X # SCREW;FLPHCUT1/4"20X1-1/4ZN ANCHOR;SCREW KH-EZ 1/4" X 3" STICK;WOOD 3/8"X1/16"X4-1/2" BIT;DRILL MASONRY 1/4X6" REFER TO HARDWARE VARIANT 6 EZD; LATCH PLATE REFER TO HARDWARE VARIANT 8 REFER TO HARDWARE VARIANT 9 EZD;4FT LATCH STRAP SCREW;TRUSSPHMACH10-24X2-1/2SS SPACER;.5OD.192ID X SPACER;.3125OD.192ID X NUT;NYLOCK #10-24 SS WASHER;FLAT 1/4"SS KNOB;FOUR-ARM NYLON 1/4"-20" CAP;VINYL 1/4"-5/16" BLACK WASHER;NYLON, #10 SCREW REFER TO HARDWARE VARIANT 19 REFER TO HARDWARE VARIANT 20 SEALANT, POLYURETHANE, GRAY

12 Inspection and Maintenance XIII. Inspection and Maintenance (Minimum Annually) IMPORTANT! Consult Approved for Construction Drawings and Anchor Manufacture Technical Manual before replacing fasteners, as most have specific design load requirements. A. Frame Assembly: 1. Inspect components for damage and misalignment. Adjust, repair, or replace as needed, to meet original design tolerance. B. Panel Assembly: 1. Inspect panel for corrosion or damage, repair or replace as necessary. 2. Inspect door panel alignment and free movement; clearance from ground/walking surface. Adjust panel as necessary. C. Embedded Items: 1. Inspect all embedded components for corrosion, damage, and misalignment. Adjust, repair, or replace as needed, to meet original design tolerances. 2. Check all connections, making sure they meet original design standards (refer to Approved for Construction Drawings and Anchor Specifications). D. Fasteners and mechanical connections: 1. All fasteners must be in place and adjusted to their original design standard, per included anchor manufacture technical manual. 2. Replace any damaged components (refer to Approved for Construction Drawings and Anchor Specifications). E. Sealants and Waterstops: 1. Inspect all sealants used on jambs and connections to ensure their effectiveness. 2. Replace any cracked, loose, and otherwise non-performing sealants. 3. Use only factory approved/supplied products (refer to Approved for Construction Drawings). a. Factory approved sealant/waterstops: Sika; Sikaflex-227. F. Gasket: 1. Inspect all gaskets and corner splice for damage, and for continuous adhesion to the attached surface. 2. Visually inspect all gaskets for proper positioning, compression, and continuous contact with door panel. 3. Replace or repair if damage or deterioration to gaskets has occurred. 4. Use only factory approved materials (refer to Approved for Construction Drawings). 5. Use only factory approved installation guidelines (refer to Gasket Replacement Instructions). G. Lock/Latch: 1. Operate all latching hardware to ensure smooth, uninhibited movement of all mechanical components. 2. Position flood barrier and check latches for proper engagement. If gaskets are not properly positioned and properly compressed, unlatch flood barrier panel and adjust latching accordingly. 3. Periodically lubricate hardware and other components according to manufacturer s instructions (refer to applicable hardware guides). I. Finishes: 1. Inspect all surfaces for signs of wear or corrosion and clean finishes periodically. 2. Touch up repair finishes, or refinish as necessary to protect the structural integrity. J. Housekeeping: 1. Clean sill and jambs of any debris and keep the area clean throughout the operating area of the door. 2. For all surfaces (Industrial Enamel, Epoxy, Powder Coat finishes, Stainless Steel): a. Make a mixture of warm water and a gentle dish soap, using a soft cloth/rag, scrub the door and frame. b. Rinse off with water and dry with paper towel. 3. Clean all gaskets and seals with a soft rag with warm water and dry off with paper towel. K. Labels and Placards: 1. Inspect all labels and placards. 2. Replace any labels and placards which are unreadable/missing. 12 PS INDUSTRIES INCORPORATED All Rights Reserved. EzDam

13 Inspection and Maintenance Log CRITICAL Periodic Inspection and Maintenance Required. Inspect at minimum annually. Date Purchased: Product: Model Number: Serial Number: Opening Identifier/ Number: Location: DATE INSPECTED INSPECTED BY (Print & Sign) INSPECTION ITEMS NOTED CORRECTIVE ACTION CORRECTED BY (Print & Sign) EzDam PS INDUSTRIES INCORPORATED All Rights Reserved. 13

14 PS FLOOD BARRIER WARRANTY REGISTRATION FORM PS Flood Barriers TM Product Warranty Registration: For PS Flood Barriers TM Products, the Limited Warranty will only be valid if the Owner completes, and returns, this PS Flood Barrier Warranty Registration Form within thirty (30) days of Product installation. To request additional copies of the Warranty Registration Form, contact PS Industries TM Incorporated, 1150 S. 48th Street, Grand Forks, ND 58201, phone , For a fillable form, download a copy from To register online: The following information is required: Owner Name: Company: Address: State/Provence: Product Name: Model: Serial Number: Date Installed: Zip/Postal Code: Country: Although testing of flood barriers is not required, PS Industries TM Incorporated recommends testing flood barriers after installation to verify the suitability of the installation and ensure proper adjustment of flood barrier for optimum performance. The following information and signatures are required to ensure warranty coverage of installed product. 1. Was the flood barrier field tested after installation? Yes No 2. If tested, which type(s) of testing was conducted? Hose Test per PS Flood Barriers testing procedure. Hydrostatic Test per PS Flood Barriers testing procedure. Other Testing Method (describe below): Owner or Installer Name (Please print.) Test Witness Name (Please print.) Signature Signature Date Date Return form to: PS Flood Barriers Fax: Attention: Warranty 4psinfo@psindustries.com 1150 S. 48th Street Grand Forks, ND (Make additional copies as necessary) Rev PS INDUSTRIES INCORPORATED All Rights Reserved. EzDam

15 PS INDUSTRIES INCORPORATED LIMITED WARRANTY Limited Warranty: Subject to the terms of this Limited Warranty, PS INDUSTRIES INCORPORATED warrants to the original user or consumer (the Owner ) of a PS INDUSTRIES INCORPORATED product (the Product ) that, for a period of one (1) year from date of shipment, the Product will be free from defects in material and workmanship under normal use and service, and provided the Product is installed, operated and maintained in accordance with instructions supplied by PS INDUSTRIES INCORPORATED. The terms and limitations of this Limited Warranty apply to all repaired or replacement Products for a term equal to the balance of the warranty remaining on the Product that was repaired or replaced as of the date of such repair or replacement. Register online at: PS Flood Barriers TM Product Warranty Registration: For PS Flood Barriers TM Products, this Limited Warranty will only be valid if the Owner completes the Warranty Registration Form provided within thirty (30) days of Product installation. To request a copy of the Warranty Registration Form, contact PS INDUSTRIES INCORPORATED, 1150 S. 48th Street, Grand Forks, ND 58201, phone , 4psinfo@psindustries.com. Register online at: Additional Warranty Registration Forms can be downloaded at Warranty Exclusions: Notwithstanding anything to the contrary, this Limited Warranty does not cover any of the following: 1. Normal wear and tear (including, but not limited to, normal wear and tear to gaskets and weather seals); damage or accidents resulting from freight damage, from failure to follow precautionary safety measures, or applied paint failure; abuse, misuse or unauthorized modification of the Product; misapplication; improper installation; or any defects, damage or other harm that is not the result of the acts or omissions of PS INDUSTRIES INCORPORATED. 2. Cost of field labor or other charges incurred by Owner in removing and/or re-affixing the Product or any part or component thereof. 3. Transportation costs. Unauthorized modification of or to the Product voids this Limited Warranty. Authorized modifications, received in writing from PS INDUSTRIES INCORPORATED, as long as the modification is accomplished in strict accordance with PS INDUSTRIES INCORPORATED s instructions, does not void warranty. To request product modifications contact PS INDUSTRIES INCORPORATED, 1150 S. 48th Street, Grand Forks, ND 58201, phone , 4psinfo@psindustries.com. Claim Procedure: To make a claim under this Limited Warranty, the claim must be received by PS INDUSTRIES INCORPORATED before the expiration of the above stated Limited Warranty period together with proof of purchase. Contact PS INDUSTRIES INCORPORATED at the address shown below. PS INDUSTRIES INCORPORATED Toll Free: Attention: Warranty Phone: S. 48th Street Fax: Grand Forks, ND psinfo@psindustries.com An authorized PS INDUSTRIES INCORPORATED representative must be given a reasonable opportunity to inspect and investigate the alleged Product defect prior to any work being done that affects the Product or its installation. PS INDUSTRIES INCORPORATED reserves the right to charge reasonable amounts for travel and labor associated with investigation of claims. PS INDUSTRIES INCORPORATED may also require photographs of the alleged Product defect or return of the Product or part to a designated PS INDUSTRIES INCORPORATED location, freight prepaid. A return goods authorization must be received prior to the return of the Product or part. Please contact PS INDUSTRIES INCORPORATED to determine the designated location for return and to obtain the return material authorization. Exclusive Remedy: In the event of a warranty claim that PS INDUSTRIES INCORPORATED determines to be covered by this Limited Warranty, PS INDUSTRIES INCORPORATED will replace or repair, at PS INDUSTRIES INCORPORATED s discretion, the Product or any part of the Product found to be defective. Disclaimers: The above warranty and remedy is the sole express warranty and remedy given by PS INDUSTRIES INCORPORATED on its Product. No warranties or representations at any time made by any representative from PS INDUSTRIES INCORPORATED shall vary or expand the provisions hereof. TO THE EXTENT PERMITTED BY LAW, ALL EXPRESS AND IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT) OTHER THAN THE EXPRESS LIMITED WARRANTY SET FORTH ABOVE ARE EXPRESSLY DISCLAIMED. UPON THE EXPIRATION OF THE ABOVE STATED LIMITED WARRANTY PERIOD, ANY AND ALL APPLICABLE IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON- INFRINGEMENT, ARE DISCLAIMED. SOME STATES DO NOT ALLOW LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO OWNER. LIABILITY LIMITATION: In no event will PS INDUSTRIES INCORPORATED s liability to Owner or any other person or entity exceed the price paid to PS INDUSTRIES INCORPORATED for the defective Product. IN NO EVENT SHALL PS INDUSTRIES INCORPORATED BE LIABLE TO OWNER OR ANY OTHER PERSON OR ENTITY FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT OR SPECIAL DAMAGES OF ANY DESCRIPTION, WHETHER ARISING OUT OF WARRANTY (INCLUDING ANY IMPLIED WARRANTIES) OR ANY OTHER CONTRACT, STRICT LIABILITY, NEGLIGENCE OR OTHER TORT, OR OTHERWISE, INCLUDING ARISING FROM INSPECTION OR REMEDY DELAYS. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION AND EXCLUSION MAY NOT APPLY TO OWNER. THIS WARRANTY GIVES OWNER SPECIFIC LEGAL RIGHTS AND OWNER MAY ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE. Rev EzDam PS INDUSTRIES INCORPORATED All Rights Reserved. 15

16 psfloodbarriers.com 1150 South 48th Street Grand Forks, ND Product Registration: psindustries.com/contact/register-your-product