1 Compact Video Complete Walkthrough Pre-Installation guide Prepare for your TopBrewer. A comprehensive step-by-step installation guide is available through your dealer, authorized installer or our website, TopBrewer.com Scanomat Download Center Scanomat Connection Diagram Scanomat Architect Pack (2D/3D Files) For all TopBrewer Compact 2014 forward Version:

2 CONTENTS Installation Requirements 3 Space requirements 4 CARPENTER 5 Cutout overview 6 Examples of other configuration 7 Cut out sheet 8 VENTILATION 9 Ventilation requirements 10 ELECTRICAL 11 Electrical Requirements 12 PLUMBING 13 Plumbing option 1 14 Plumbing option

3 Installation Requirements Video Installation Walkthrough TB A1 A2 A3 B1 Machine Fridges Water coolers * OPTIONALLY WITH CO 2 UNIT DETAILS TB A1 A2 A3 TopBrewer Compact ICE-Bank* Pro-fridge Pro-fridge Tall Cooler 45* B1 Installation Dimensions (WxDxH) 183 x 510 x 670 mm 236 x 569 x mm 231 x 600 x 430 mm 231 x 438 x 600 mm 255 x 486 x 404 mm Packing Dimensions (WxDxH) 300 x 630 x 780 mm 246 x 579 x mm 300 x 615 x 490 mm 241 x 443 x 660 mm 265 x 483 x 464 mm Weight, gross. 41 kg 25 kg 20 kg 20 kg 22 kg Weight, net. 39 kg 22 kg 17 kg 17 kg 19 kg Bean/Carton Capacity 1.5 kg Up to 4 l. Up to 8 l. Up to 8 l. - Throughput/hour 120 cups 25 L L Approvals CE, ETL/UL, CB, NSF CE CE, ETL/UL CE, ETL/UL CE, ETL/UL, NSF REQUIREMENTS TopBrewer Compact TB ICE-Bank A1 Pro-fridge A2 Pro-fridge Tall A3 Cooler 45 B1 Power V AC, 10/20 Amp 1 phase, 2,3 / 4,6 kw, 50/60hz V, 13 Amp 3-pin plug point for each unit. For Canada & US: 115V, 60 Hz, 10 Amp, plug point for each unit. EU: Local 230V US: 6-20R / 6-20P Water Direct Water Connection, 3/4 type shutoff valve Water pressure: 200kPa (2 Bar) kpa (6 Bar) - - Direct Water Connection, 3/4 type shutoff valve Water pressure: 200kPa (2 Bar) kpa (6 Bar) Filtration TopBrewer water filters fitted in a location adjacent to the TopBrewer. (pages 7 + 8) Dedicated steam filter required (Pure 50, 0% bypass) TopBrewer ActiveCoal , optional, purifies the water with active coal technology and can be fitted to remove unwanted odors, impurities etc - - TopBrewer ActiveCoal , optional, purifies the water with active coal technology and can be fitted to remove unwanted odors, impurities etc Drainage Waste U-pipe, ø40mm. Manifold/drain plug (included, see pages ) is inserted and components are connected here. Ventilation Machine and fridge produces heat, which needs to be able to exit as per installation instructions. See carpenter requirements (pages 7 + 8) and ventilation specs (page 11) 3

4 STRONG YES NO MILD CLEAN STOP ON/OFF COFFEE ESPRESSO CAPPUCCINO COLD MILK HOT WATER WATER COLD WATER SPARKLING WATER SPACE REQUIREMENTS 519 (20 7 / 16 ") Total width Clearance height needed for installation of swan neck min 500 mm 253 (9 15 / 16 ") ipad AMERICANO MACCHIATO LATTE WARM MILK STEAMING 670 (26 3 / 8 ") Ideal 690 (27 3 / 16 ") Water inlet TB A1 430 (16 15 / 16 ") Electricity 40(1 9/16 ) 60 (2 3/8 ) min. 90 mm Depth dependent on A1 : 569 mm A2: 600 mm A3: 534 mm A4; 560 mm See page 4 fridge Always allow min. 40 mm clearance Always allow min. 60 mm clearance 4

5 CARPENTER Video Carpenter Walkthrough 5

6 CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER 71 mm Cutout overview 1 UNITS: TB + A1 ** 1,5 M HOSE LENGTH minimum requirements 220 mm 30 mm OR ipad 110 mm 110 mm 30 mm Air exhaust for heat from fridge See page 9 for details Cutout dependent on fridge selection See next page for more examples. Cutout here 176 mm 283 mm 39 mm Min. 530 TB A1 TB A1 472 mm Side Front Top View 7-0,25 + 4,00 Divide Panel ( Mandatory ) (Needs a tight fit) ** NOTE: CONTACT A SALES REPRESENTATIVE FOR ALTERNATIVE PLACEMENTS OF THE FAUCET. 6 CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER

7 CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER Examples of other configurations All cabinets are based on standard 60 cm cabinets 2 UNITS: TB + A3 3 UNITS: TB + A3 + B1* Air exhaust for heat from Fridge/Cooler See page 11 for details Cutout dependent on Fridge/Cooler selection Cutout here 146 mm 146 mm 134 mm 332,5 mm TB 49,5 mm 332,5 mm 40 mm 49,5 mm 43,5 mm A3 TB A3 B1* Min mm Min mm 26 mm Min. 460 Divide Panel ( Mandatory ) (Needs a tight fit) 4 UNITS: TB + A1 150 mm Divide Panel ( Mandatory ) (Needs a tight fit) 318,5 mm 35,5 mm 16 mm TB A2 Min. 579 Divide Panel ( Mandatory ) (Needs a tight fit) CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER 7

8 CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER Cut out sheet - Swan neck + Driptray NOTE that this driptray is best used for water resistent tabletops such as Granite, Marble or Corian. If wood, make sure poures are completely sealed. Flush mounted - Countersunk - Driptray A Top mounted - With Lip - Driptray _A B In standard configuration (See page 4) * Optional recessed ipad holder 8 CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER CARPENTER

9 VENTILATION Video Ventilation Walkthrough 9

10 VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION Ventilation requirements The sensor should be placed as high as possible, though no higher than 10 cm from the underside of the tabletop. The sensor can be placed on the backing or sidepanel. A dividing panel is inserted, seperating the toekick in two equal sized spaces Place the hood ontop of the ventilation outlet made in the cabinet. This lets the hot air exit directly through the toekick. Note: The hood is fitted to the back of the fridge/cooler from factory Overall Requirements: The ventilation assembly can be mounted on a custom ventilation grate or on the aluminum grate which is a part of the kit. Maximum 35 o C / 95 o F operating temperature, measured at the top of the cabinet Allow both TopBrewer and fridge clearance to ensure airflow. The clearances are included in the specified measurements on page 5. (Needs a tight fit) Divide Panel ( Cold air inlet Hot air outlet Mandatory) Ventilation kit: no VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION

11 VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION 2. Ventilation Console (ICE-bank only) The console is easier to mount as it requires less custom work on the cabinet. It also add s the sliding function for easier maintenance. Watch the video Overall Requirements: Maximum 35 o C / 95 o F operating temperature, measured in the top of the cabinet Allow both TopBrewer and fridge clearance to ensure airflow. The clearances are included in the specified measurements on page 7 505,5 mm Cold air inlet Front overhang of the bottom of cabinet is removed to allow in/out flow of air 560 mm 264 mm Hot air outlet Console Ventilation kit: no VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION VENTILATION

12 ELECTRICAL Video Electrical Walkthrough 12

13 ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL STRONG YES NO MILD CLEAN STOP ON/OFF COFFEE ESPRESSO CAPPUCCINO COLD MILK HOT WATER WATER COLD WATER SPARKLING WATER Electrical Requirements Electrical installation area ipad AMERICANO MACCHIATO LATTE WARM MILK STEAMING Plug point for fridge, ventilation & ipad All electrical must be kept within boundary 3 X Single phase 230V, 10 amp US & Canada: Single phase 115V, 60 Hz, 10 Amp Safety switch for machine main power S Single phase 230V, 10/20 amp 1600 mm cable length ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL 13

14 PLUMBING Video Plumbing Walkthrough 14

15 PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING Plumbing option 1 Drainline from driptray Fridge waste water 1 m 5 cm Filter overview Main Water w/ shutoff valve Filters Filters are chosen based on the projected usage pattern of the machine. Distance of installation relative to the machine are unlimited. An example of the capacity is listed below. Capacity: Example: 30% bypass, o dh. 15 C150: 1390 l. C l. C500: 2926 l. Drainline Ø18mm ipad C500 C300 C150 Drain plug provided Pipe size Ø mm 464 mm 417 mm 144 mm 125 mm 119 mm CO2 Optional Co 2 bottle placement. (if applicaple). Must be standing upright, max pressure setting 3 bar. PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING 15

16 PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING STRONG YES NO MILD CLEAN STOP ON/OFF COFFEE ESPRESSO CAPPUCCINO COLD MILK HOT WATER WATER COLD WATER SPARKLING WATER Plumbing option 2 Drainline from driptray Fridge waste water Main Water w/ shutoff valve Drainpump from machine Drainline Ø18mm 1 m 5 cm ipad Filter overview Filters Filters are chosen based on the projected usage pattern of the machine. Distance of installation relative to the machine are unlimited. An example of the capacity is listed below. Capacity: Example: 30% bypass, o dh. 15 AMERICANO MACCHIATO LATTE WARM MILK STEAMING C150: 1390 l. C l. C500: 2926 l. Drain plug provided Pipe size Ø40 C500 C300 C150 Maximum height 100mm Maximum height 100mm CO2 557 mm 464 mm 417 mm 144 mm 125 mm 119 mm * Optional Co 2 bottle placement. (if applicaple). Must be standing upright, max pressure setting 3 bar. Plumber & Carpenter may need to arrange placement of the divider PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING PLUMBING 16