B-1 DIRECT WATERPROOFING APPLICATION TO LAGGING FOLD OVER ARMORCLAY 1000 FOR GRADE LINE TERMINATION VERTICAL GEO-MAT C DRAIN 110 OR 150 FASTENERS

Size: px
Start display at page:

Download "B-1 DIRECT WATERPROOFING APPLICATION TO LAGGING FOLD OVER ARMORCLAY 1000 FOR GRADE LINE TERMINATION VERTICAL GEO-MAT C DRAIN 110 OR 150 FASTENERS"

Transcription

1 FOLD OVER FOR GRADE LINE TERMINATION C DRAIN 110 OR 150 FASTENERS HORIZONTAL TIEBACK COVER AND MASTIC B-1 DIRECT APPLICATION TO LAGGING

2 C DRAIN 110 OR 150 FASTENERS MEMBRANE BONDED WITH INSIDE AND OVER SEAMS HORIZONTAL TIEBACK COVER AND MASTIC B-2 DIRECT DIRECT APPLICATION TO LAGGING APPLICATION TO LAGGING

3 VERTICAL GEO-MAT C DRAIN 110 OR 150 TIEBACK COVER AND MASTIC FOLD OVER FOLD AS SHOWN FOR TEMP. GRADE LINE TERMINATION OR FUTURE TIE-INS AND TEMPORARILY NAIL EVERY 18" TO 36" O.C. USING WASHERS WITH HDPE SIDE AGAINST WOOD LAGGING FASTENERS HORIZONTAL B-3 DIRECT APPLICATION TO LAGGING

4 TERMINATION BAR GRANULAR PACK CANT (TYPICAL) (BENTONITE AGAINST EARTH FILL) POLY (TYPICAL) (BENTONITE FACING CONCRETE) C DRAIN 110 OR 150 DOUBLE LAYER OVER COLD JOINTS (TYP) (BENTONITE FACING CONCRETE) WATERSTOP W/ DETAIL 1 (BENTONITE AGAINST CONCRETE) DETAIL 2 COLLAR MASTIC (BENTONITE UP OPTIONAL) EXPANDABLE TAPE W/ PRIMER MEMBRANE POLY (TYPICAL) OPTION 1 GRANULAR PACK CANT (TYPICAL) GRANULAR PACK CANT (TYPICAL) OPTION 2 MASTIC B-4 AROUND EXTERIOR PILECAPS AROUND EXTERIOR PILECAPS

5 GROUT FILL C DRAIN 110 OR 150 (2) LAYERS B-5 INSTALLATION COVERING OBTUSE ANGLED CORNER INSTALLATION COVERING OBTUSE ANGLED CORNER

6 C DRAIN 110 OR 150 (ALLOW ENOUGH MEMBRANE TO TIE-IN TO FLOOR/DECK) MEMBRANE (BENTONITE FACING DOWN ON CONCRETE) MEMBRANE (BENTONITE FACING CONCRETE) (ALLOW ENOUGH MEMBRANE TO TIE-IN TO FLOOR/DECK) WATERSTOP WATERSTOP STEP #1 STEP #2 FOLD MEMBRANE (BENTONITE FACING DOWN ON CONCRETE) FOR PROPER TIE-IN DETAIL GRAVEL FILL DRAIN TILE BITUMEN TAPE (BENTONITE FACING CONCRETE) WATERSTOP BITUMEN TAPE (BENTONITE FACING CONCRETE) WATERSTOP C DRAIN 110 OR 150 C DRAIN 110 OR 150 (NAILED OR STAPLED TO WOOD LAGGING) (BENTONITE FACING CONCRETE) STEP #3 STEP #4 B-6 WALL TO DECK TIE-IN DETAIL

7 600, OR 1500 WITH SEAM TAPE OR BITUMEN TAPE DRAIN TILE C DRAIN 150 (OPTIONAL) WATERSTOP GRANULAR PACK (2" CANT) C DRAIN TILE (OPTIONAL) B-7 TYPICAL UNDERGROUND WALL SECTION TYPICAL UNDERGROUND WALL SECTION

8 GEO-MAT C DRAIN 150 OR 400 (OPTIONAL) 600, OR 1500 WITH SEAM TAPE OR BITUMEN TAPE WATERSTOP SEAM TAPE OR BITUMEN TAPE WATERSTOP GRANULAR PACK (2" CANT) B-8 CUT AND COVER SUBWAY OR TUNNEL CUT AND COVER SUBWAY OR TUNNEL

9 DRAIN TILE GEO-MAT C DRAIN 150 (OPTIONAL) 600, OR 1500 WITH B-9 ROOF/WALL TRANSITION DETAIL SHOWING OPTIONAL SURFACE DRAIN ROOF/WALL TRANSITION DETAIL SHOWING OPTIONAL SURFACE DRAIN

10 GEO-MAT C DRAIN 400 (OPTIONAL) SLIP PLATE 600, OR 1500 STRIP 600, OR 1500 WITH B-10 ON PRE-STRESSED PLANK ON PRESTRESSED PLANK

11 600, OR 1500 STRIP GEO-MAT C DRAIN 400 (OPTIONAL) PAVERS 600, OR 1500 WITH EARTH AGGREGATE SLIP PLATE B-11 THERMAL BREAK (EXPANSION OR ISOLATION JOINT)

12 FLASHING AND SEALANT SHOCKWAVE OR VERTICAL GEO-MAT C DRAIN 110 OR 150 OPTION #1 SEE OPTIONS #1, #2, #3 TERMINATION BAR PROTECTION BOARD ( C DRAIN 110 OR 150 (TYPICAL / OPTIONAL) OPTION #2 600, OR 1500 (BENTONITE FACING CONCRETE) BITUMEN TAPE WITH OPTION #3 B-12 GRADE LINE TERMINATION GRADE LINE TERMINATION

13 EARTH GEO-MAT C DRAIN 400 (OPTIONAL) 600, OR 1500 WITH PAVERS FLASHING AROUND DRAIN ROOF/DECK DRAIN AGGREGATE / SAND B-13 TYPICAL DRAIN DETAIL

14 600, OR 1500 WITH GEO-MAT C DRAIN 400 AGGREGATE, EARTH FILL TERMINATION BAR (BENTONITE UP) AGGREGATE, EARTH FILL MASTIC ADHESIVE TERMINATION BAR, SEAM TAPE OR BITUMEN TAPE GRANULAR PACK (2" CANT) 600 TERMINATION BAR, SEAM TAPE OR BITUMEN TAPE MUD SLAB 600 GRANULAR PACK (2" CANT) TERMINATION BAR 1500 GRANULAR PACK (2" CANT) WATERSTOP AGGREGATE, EARTH FILL 1500 GRANULAR PACK (2" CANT) B-14 FLOOR TO WALL TRANSITION WITH BELOW FLOOR DRAINAGE

15 (BENTONITE DOWN) C DRAIN 110 OR 150 (OPTIONAL) (BENTONITE UP) C DRAIN 110 OR 150 (OPTIONAL), 600 WITH MASTIC ADHESIVE OR 1500 SYSTEM 600 C DRAIN 110 OR 150 (OPTIONAL) WATERSTOP 600 MUD SLAB 1500 C DRAIN 110 OR 150 (OPTIONAL), 1500 OR B-15 ELEVATOR PIT CROSS SECTION DETAIL ALL SEAMS ADHERABLE WITH

16 600 3" OVERLAP TYPICAL OVERLAP 600 WITH 6 MIL POLYETHYLENE SEAM TAPE OR BITUMEN TAPE MUD SLAB 600 WITH 6 MIL POLYETHYLENE 3" OVERLAP TYPICAL OVERLAP 1500 GEO-MAT C DRAIN 110 OR 150 (TYPICAL) BITUMEN TAPE 1500 GEO-MAT C DRAIN 110 OR 150 (TYPICAL) " OVERLAP TYPICAL OVERLAP MUD SLAB TYPICAL UNDER FLOOR WITHOUT MUD SLAB (BENTONITE UP) 600 WITH 6 MIL POLYETHYLENE WITH MUD SLAB WITHOUT MUD SLAB / PROTECTION SHEET 1500 GEO-MAT C DRAIN 110 OR 150 (TYPICAL) AND BASE SHEET AGGREGATE 6 MIL POLYETHYLENE (TYPICAL) WITH MUD SLAB WITHOUT MUD SLAB B-16 UNDER FLOOR CROSS SECTION

17 TERMINATION BAR, SEAM TAPE OR BITUMEN TAPE (BENTONITE UP) EXPANDABLE TAPE 6 MIL POLYETHYLENE, 600 OR 1500 SYSTEM GRANULAR PACK (2" CANT) TERMINATION BAR, SEAM TAPE OR BITUMEN TAPE SEAM TAPE, BITUMEN TAPE OR TERMINATION BAR BITUMEN TAPE 6 MIL POLYETHYLENE 600 WITH TERMINATION BAR 600 MUD SLAB 6 MIL POLYETHYLENE MIL POLYETHYLENE 6 MIL POLYETHYLENE -, 1500 OR B-17 FOOTING TO FLOOR TRANSITION CROSS SECTION

18 TERMINATION BAR OR WOOD LATH GRANULAR PACK (2" CANT) (BENTONITE AGAINST EARTH FILL) 6 MIL POLYETHYLENE (BENTONITE FACING CONCRETE) C DRAIN 110 OR 150 DOUBLE LAYER OVER COLD JOINTS (BENTONITE FACING CONCRETE) WATERSTOP WATERSTOP DETAIL 1 (BENTONITE AGAINST CONCRETE) DETAIL 2 COLLAR MASTIC (BENTONITE UP OPTIONAL) EXPANDABLE TAPE WITH 6 MIL POLYETHYLENE OPTION 1 GRANULAR PACK (2" CANT) GRANULAR PACK (2" CANT) OPTION 2 MASTIC B-18 AROUND EXTERIOR PILECAPS NOTE: 600 AND 1500 ALTERNATIVE DRAWINGS ALSO AVAILABLE

19 STEP 2: INSTALL (BENTONITE AGAINST CONCRETE FLOOR) STEP 3: FOLD BACK MEMBRANE AND STAPLE 8" O.C. C DRAIN 110 OR 150 TEMPORARILY FASTEN MEMBRANE STEP 1: FOLD MEMBRANE OVER TO ALLOW PROPER TIE-IN TO FLOOR AND WALL TRANSITION STEP 2: INSTALL 600 WITH IN AND OVER SEAMS (BENTONITE AGAINST CONCRETE FLOOR) STEP 3: FOLD BACK MEMBRANE SEAM WITH C DRAIN 110 OR STEP 2: INSTALL 1500 MEMBRANE STEP 3: FOLD BACK MEMBRANE AND STAPLE 8" O.C. C DRAIN 110 OR B-19 BENTONITE UP / MEMBRANE DOWN INTERIOR FOOTING

20 STEP 2: INSTALL (BENTONITE AGAINST FILL) STEP 3: FOLD BACK MEMBRANE AND STAPLE 8" O.C. C DRAIN 110 OR 150 TEMPORARILY FASTEN MEMBRANE STEP 1: FOLD MEMBRANE OVER TO ALLOW PROPER TIE-IN TO FLOOR AND WALL TRANSITION STEP 2: INSTALL 600 WITH (BENTONITE AGAINST FILL) STEP 3: FOLD BACK MEMBRANE AND USE C DRAIN 110 OR STEP 2: INSTALL 1500 STEP 3: FOLD BACK MEMBRANE AND STAPLE 8" O.C. C DRAIN 110 OR B-20 BENTONITE DOWN / MEMBRANE UP PILECAP BELOW FOOTING

21 MASTIC 6 MIL POLYETHYLENE C DRAIN 110 OR 150 CLAMP OR SEAM TAPE, 1500 OR 600 COLLAR 6 MIL POLYETHYLENE C DRAIN 110 OR 150 STEP ONE CLAMP OR SEAM TAPE, 1500 OR 600 COVER STEP TWO 600, 1500 OR SYSTEM STEP THREE B-21 UNDER SLAB PIPE PENETRATION (TYPICAL)

22 (BENTONITE UP) MUD SLAB MUD SLAB 600 WITH MASTIC ADHESIVE MUD SLAB , 1500 OR 600 WITH MASTIC ADHESIVE 1500 MUD SLAB B-22 TYPICAL DRAIN DETAIL