I S GENERAL NOTES TITLE SCALE: 1/4" = 1'-0" ARCHITECTURAL SCOPE

Size: px
Start display at page:

Download "I S GENERAL NOTES TITLE SCALE: 1/4" = 1'-0" ARCHITECTURAL SCOPE"

Transcription

1

2 GENERAL NOTES 1. LAWS AND ORDINANCES: AS USED HEREIN SHALL MEAN ALL COUNTY, STATE AND NATIONAL CODES, ORDINANCES, STANDARDS, RULES AND REGULATIONS OF ANY NATURE WHICH ARE PERTINENT TO, OR REGULATORY OVER, THE WORK COVERED BY THE CONTRACT DOCUMENTS OF THIS PROJECT. ALL CONTRACTORS SHALL COMPLY FULLY WITH ALL APPLICABLE LAWS AND ORDINANCES. ALL CONSTRUCTION SHALL CONFORM TO THE CURRENT BUILDING CODE AND THE LATEST COUNTY OF KAUAI AMENDMENTS OR THE RESPECTIVE CITY AND/OR COUNTY AMENDMENTS BY EACH AGENCY HAVING JURISDICTION OF THE PROJECT. 2. CONFLICT: IN THE CASE OF ANY CONFLICT WHEREIN THE METHODS, OR STANDARDS OF INSTALLATION, OR THE SPECIFIED MATERIALS ARE NOT EQUAL TO, OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN. IN THE CASE OF A DISCREPANCY IN THE DRAWINGS OR SPECIFICATIONS, BUT NOT DIRECTLY RELATED TO THE PROVISIONS OR CODES, OR ORDINANCES, THE CONTRACTOR SHALL 1) PROVIDE THE BETTER QUALITY, OR GREATER QUANTITY OF WORK, OR 2) COMPLY WITH THE MORE STRINGENT REQUIREMENT IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. THE CONTRACTOR SHALL NOTIFY THE PRIME ENGINEER OF ALL CONFLICTS. 3. CONDITIONS OF THE WORK: THE INFORMATION INDICATED ON THE DRAWINGS ARE BASED ON LIMITED FIELD INVESTIGATIONS AND ON THE AVAILABLE RESOURCES AT THE TIME OF DOCUMENT PREPARATION. AS A RESULT, THE ACCURACY AND COMPLETENESS OF THE INFORMATION IS NOT GUARANTEED. THE CONTRACTOR SHALL, THEREFORE VERIFY THE DIMENSIONS SHOWN ON THE DRAWINGS WITH ACTUAL FIELD MEASUREMENTS, EXAMINE THE JOB SITE, VERIFY ALL FIELD CONDITIONS AND PROVIDE THE LABOR AND MATERIALS REQUIRED TO COMPLETE THE REQUIRED WORK. ALL WORK SHALL BE PERFORMED IN A PROFESSIONAL MANNER THAT IS OF ACCEPTABLE WORKMANSHIP OF THE RESPECTIVE TRADES. THE CONTRACTOR SHALL NOTIFY THE PRIME ENGINEER PRIOR TO THE COMMENCEMENT OF WORK, IF THERE ARE ANY DIMENSIONAL DISCREPANCIES, OR IF THERE ARE ANY CONDITIONS THAT EXIST WHICH MAY PREVENT THE CONTRACTOR'S PERFORMANCE OF WORK, AND/OR OF ANY AND ALL ADDITIONAL WORK THAT MAY BE REQUIRED AS A RESULT OF THE OBSERVED CONDITIONS. 4. OMISSIONS: OMISSIONS OF THE DRAWINGS, OR SPECIFICATIONS, OR THE OMISSIONS OF DETAILS OF WORK WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED, OR INCORRECTLY DESCRIBED DETAILS OF THE WORK, BUT SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. THE CONTRACTOR SHALL NOTIFY THE PRIME ENGINEER VERBALLY OF SUCH OMISSIONS AND PROVIDE A WRITTEN STATEMENT OF THE OMISSIONS WITHIN (5) WORKING DAYS OF VERBAL NOTIFICATION. 5. INTENT OF THE DRAWINGS: THE DRAWINGS ARE INTENDED TO DEFINE AND ESTABLISH THE PHYSICAL REQUIREMENTS OF THE PROJECT, I.E., THE DESIGN, LOCATIONS AND DIMENSIONS OF THE WORK, BASED ON RECOGNIZED STANDARDS, EVEN IF NOT ACTUALLY SHOWN, BUT REASONABLY INFERRED. ALL WORK SHOWN IS "NEW" UNLESS OTHERWISE NOTED AS "EXISTING." THE CONTRACTOR SHALL REVIEW AND VERIFY THE INFORMATION ON ALL DRAWINGS BEFORE PERFORMING THE WORK AND NOTIFY THE SCHOOL, OR PRIME ENGINEER, OF ANY DISCREPANCIES. THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL SUBCONTRACTORS/TRADES TO ACHIEVE THE DESIGN INTENT AND SPECIFIED REQUIREMENTS AND IS RESPONSIBLE TO COMPLETE ANY AND ALL WORK ASSOCIATED WITH SUCH COORDINATION. 6. COMPLETION OF THE WORK: THE CONTRACTOR SHALL, IN THE WORK OF ALL TRADES, PERFORM ANY AND ALL CUTTING, PATCHING, REPAIRING, RESTORING AND THE LIKE NECESSARY TO COMPLETE THE WORK AND RESTORE ANY DAMAGED OR AFFECTED SURFACES RESULTING FROM THE WORK OF THIS CONTRACT TO THEIR ORIGINAL CONDITION TO THE SATISFACTION OF THE ARCHITECT. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES OF CONSTRUCTION, INCLUDING, BUT NOT LIMITED TO SAFETY PRECAUTION. 7. CLEAN UP: THE CONTRACTOR SHALL CLEAN AND REMOVE ANY TRASH, DIRT, DEBRIS AND SPILLAGE ARISING FROM THE WORK DAILY TO THE SATISFACTION OF THE OWNER AND THE PRIME ENGINEER. 8. RECORD DRAWINGS: THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A FULL SIZE SET OF BOND "AS-BUILT" DRAWINGS OF WORK. 9. DIMENSIONS: UNLESS OTHERWISE NOTED IN THE CONSTRUCTION DOCUMENTS, ALL DIMENSIONS ARE TAKEN TO THE FACE OF EXISTING STRUCTURE, OR FACE OF CONSTRUCTION. WRITTEN DIMENSIONS PREVAIL, DO NOT SCALE DRAWINGS. SHOULD DIMENSIONAL DISCREPANCIES BE FOUND, CONTACT THE ARCHITECT FOR CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK. 10. PREVENT DAMAGE: THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO EXISTING AND COMPLETED STRUCTURES AND SHALL BE FULLY RESPONSIBLE FOR ANY DAMAGE TO EXISTING STRUCTURES CAUSED BY HIS OPERATIONS. 11. DO NOT BLOCK EXITS: THE CONTRACTOR SHALL NOT BLOCK OR OBSTRUCT ANY EXIT WAYS DURING THE EXECUTION OF WORK THROUGHOUT THIS PROJECT. 13. SUBCONTRACTORS: THE USE OF UNLICENSED CONTRACTORS IS STRICTLY PROHIBITED. THE CONTRACTOR IS RESPONSIBLE TO THE OWNER FOR ACTS AND OMISSIONS OF THE CONTRACTOR'S EMPLOYEES, SUBCONTRACTORS AND THEIR AGENTS AND EMPLOYEES, AND OTHER PERSONS PERFORMING PORTIONS OF WORK UNDER CONTRACT WITH THE CONTRACTOR. 14. PERMITS: THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS REQUIRED. 15. DISSIMILAR METAL PROTECTION: THE CONTRACTOR SHALL PROVIDE DISSIMILAR METAL PROTECTION. 16. MECHANICAL AND ELECTRICAL ITEMS: ALL NEW EXPOSED MECHANICAL AND ELECTRICAL PIPING, CONDUITS, DUCTWORK AND RELATED FITTINGS, AND FASTENERS ARE TO BE PAINTED THE SAME COLOR AS THE COLOR OF THE SURFACE IT IS ATTACHED TO UNLESS OTHERWISE NOTED. 17. SAFE OPERATIONS: THE CONTRACTOR SHALL ENSURE THAT ANY AND ALL CONSTRUCTION ACTIVITIES DO NOT IMPACT OR INTERFERE WITH NORMAL OR SAFE OPERATIONS AT THE PROJECT SITE. 18. DEMOLITION WORK: MATERIALS RESULTING FROM THE DEMOLITION WORK SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL LAWS, RULES AND REGULATIONS. 19. SOUND AND NOISE CONTROL: THE CONTRACTOR SHALL NOTIFY AND COORDINATE WITH THE USER ALL WORK THAT WILL GENERATE EXCESSIVE NOISE WHICH MAY DISRUPT HOSPITAL ACTIVITIES. 20. DEFINITIONS: "FURNISH" MEANS "FURNISH ONLY". MATERIALS OR ITEMS TO BE FURNISHED SHALL BE CONSIGNED TO THE CONTRACTOR AND DELIVERED TO THE SITE. "INSTALL" MEANS "INSTALL ONLY" FURNISHED MATERIALS OR ITEMS. SUCH MATERIALS OR ITEMS SHALL BE RECEIVED AT THE SITE, UNLOADED, STORED, PROTECTED, AND INSTALLED IN PLACE, INCLUDING FINAL CONNECTION, UNLESS SUCH WORK IS SPECIFICALLY EXCLUDED. "PROVIDE" MEANS "FURNISH AND INSTALL" COMPLETE, IN PLACE AND READY FOR USE, INCLUDING FINAL CONNECTIONS. WORDS "CONTRACTOR SHALL" ARE IMPLIED AND SHALL BE SO UNDERSTOOD WHEREVER A DIRECTION IS STATED IN IMPERATIVE MOOD AND DIRECTION "PROVIDE" IS USED. UNLESS SPECIFICALLY STATED AS "EXISTING", ALL MATERIALS SHALL BE NEW IN ALL CASES WHEN NOTES ARE ADDED TO DRAWINGS. ALSO, USES OF "FURNISH" AND "PROVIDE" AUTOMATICALLY MEANS "NEW" UNLESS SPECIFICALLY STATED AS "EXISTING". ABV ARCH ALUM BD BLDG CLG CLR CMU COL CONC COND CONT DBL DET DEMO DIA DN DS DWG EA EQ EXT EXIST FIN FLR FT GA GALV GEN GC GHP GYP HT IN INFO INT MANUF MAX MECH MIN MISC MRV ABOVE ARCHITECTURAL ALUMINUM BOARD BUILDING ABBREVIATIONS CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONDITION CONTINUOUS DOUBLE DETAIL DEMOLISH; DEMOLITION DIAMETER DOWN DOWNSPOUT DRAWING EACH EQUAL EXTERIOR EXISTING FINISH FLOOR FOOT; FEET GAUGE GALVANIZED GENERAL GENERAL CONTRACTOR GUTTER HIGH POINT GYPSUM HEIGHT INCH INFORMATION INTERIOR MANUFACTURER MAXIMUM MECHANICAL MINIMUM MISCELLANEOUS MOISTURE RELIEF VENT SCOTT RJ HARADA, AIA PRINCIPAL AR OC OD OPP PERIM PL PLYWD PREFAB PV PVC QTY REF REINF REQ RD SCHED SECT SF SHT SIM SL SPECS SST SYM TEMP THK THRU TYP UON VAR VTR VIF 4/13/2018 ON CENTER OVERFLOW DRAIN OPPOSITE PERIMETER PLATE; PROPERTY LINE PLYWOOD PREFABRICATED PHOTOVOLTAIC POLYVINYL CHLORIDE QUANTITY REFERENCE REINFORCED; REINFORCING REQUIRED ROOF DRAIN SCHEDULE SECTION SQUARE FEET SHEET SIMILAR SPECIFICATIONS STAINLESS STEEL SYMMETRICAL TEMPORARY; TEMPERED THICK THROUGH TYPICAL W WIDTH W/ WITH W/O WITHOUT WD WOOD WT WEIGHT UNLESS OTHERWISE NOTED VARIES VENT THROUGH ROOF VERIFY IN FIELD # NUMBER; POUND & AND CENTER LINE 1 A-XX 1 A-XX PLAN NORTH TRUE NORTH TITLE SCALE: 1/4" = 1'-0" SYMBOLS DETAIL SYMBOL DRAWING NUMBER SHEET NUMBER SECTION SYMBOL DRAWING NUMBER SHEET NUMBER NORTH ARROW DRAWING TITLE ARCHITECTURAL SCOPE PV PANEL POSTS WILL PENETRATE THE EXISTING CONCRETE ROOF W/ FLUID APPLIED ROOFING MEMBRANE AND WE PROVIDE DETAILS TO WATERPROOF ALL PV POST PENETRATIONS. THIS IS NOT A REROOFING PROJECT. ELECTRICAL WORK INVOLVES CONDUITS, SO THERE IS PATCH PAINT WORK IN VARIOUS LOCATIONS. ROOFING IS UNDER WARRANTY AND MUST USE GAF HYDROSTOP. NO SUBSTITUTIONS ARE ALLOWED IN ORDER TO MAINTAIN THE WARRANTY. THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATION. HAR R.J. ADA LICENSED PROFESSIONAL ARCHITECT SCOTT I S I N C. No A H SIGNATURE EXP. DATE: 04/30/20 U. S II, A W A GENERAL NOTES, ABBREVIATIONS,& SYMBOLS 12. EXISTING UTILITIES: THE CONTRACTOR SHALL COORDINATE AND VERIFY THE LOCATIONS OF ALL UNDERGROUND OR OVERHEAD UTILITY LINES TO AVOID CONFLICTS DURING ALL STAGES OF CONSTRUCTION. NIC NTS NOT IN CONTRACT NOT TO SCALE 2

3 EXISTING ROOF DRAINS TO REMAIN, TYP RIDGE EXISTING HYDROSTOP ROOF TO REMAIN, TYP GC TO VERIFY ALL VENT PIPE LOCATIONS AND ENSURE SPACE BETWEEN PV PANEL AND TOP OF VENT PIPE IS 6" MINIMUM THIS WORK WAS PREPARED BY ME OR UNDER MY SUPERVISION AND CONSTRUCTION OF THIS PROJECT WILL BE UNDER MY OBSERVATION. HAR R.J. ADA LICENSED PROFESSIONAL ARCHITECT SCOTT. No A H SIGNATURE EXP. DATE: 04/30/20 U. S II, A W A RIDGE I S I N C LEGEND EXIST EXHAUST FAN TO REMAIN EXIST GOOSENECK EXHAUST TO REMAIN EXIST VENT PIPE TO REMAIN NEW PV PANEL, SEE ELECTRICAL DWGS PLAN NORTH TRUE NORTH PARTIAL ROOF PLAN - NEW WORK SCALE 1/16" = 1'-0" GC TO VERIFY EXIST VENT PIPE LOCATIONS AND ENSURE SPACE BETWEEN PV PANEL AND TOP OF VENT PIPE IS 6" MINIMUM EXISTING PARAPET WALL, TO REMAIN, TYP 1 0 8' 16' 32' 48' SCALE: 1/16" = 1'-0" M-BOND ADHESIVE UNDER M-CURB AND AT SCARF JOINTS M-THANE 1-PART POURABLE SEALANT MINIMUM 1" BETWEEN PENETRATIONS AND M-CURB M-CURB BY GAF PLAN VIEW STANDARD PREMIUM COAT ROOF SYSTEM 12" X 12" REINFORCING FABRIC OVER PIPE WRAP REINFORCING FABRIC PIPE WRAP PV PANEL POST, SEE STRUCT DWGS BEAD OF M-BOND ADHESIVE AROUND PENETRATION M-THANE POURABLE SEALANT M-CURB BY GAF M-BOND ADHESIVE EXIST PRECAST, PRE-STRESSED CONCRETE DOUBLE TEES C L 1" SECTION DETAIL PV PANEL POST, SEE STRUCT DWGS FOUNDATION COAT, FABRIC, FOUNDATION COAT, AND FINISH COAT 6" MIN BASE PLATE, SEE STRUCT DWGS NOTES: 1. SEE STRUCTURAL DWGS FOR PV POST LOCATIONS 2. COAT PENETRATIONS WITH M-BOND ADHESIVE UP AT LEAST 1" ABOVE M-CURB 3. GAF HYDROSTOP AND M CURB WITH ASSOCIATED COMPONENTS MUST BE USED TO MAINTAIN THE EXISTING ROOF WARRANTY. 4. FOLLOW MANUFACTURER'S RECOMMENDATIONS. ROOFING NOTES 1. ROOF CURRENTLY UNDER MANUFACTURERS 20 YEAR WARRANTY BY GAF # HYDROSTOP FLUID APPLIED ROOFING MUST BE INSTALLED BY A GAF CERTIFIED INSTALLER. IN ORDER TO UPHOLD THE WARRANTY THE FOLLOWING MUST BE FOLLOWED: GC TO SUBMIT CHECKLIST, SOLAR ARRAY, AND DETAILS FOR GAF TO REVIEW BEFORE WORK BEGINS, PRE-SOLAR INSPECTION $600 FEE BY GAF REQUIRED 2.2. REPAIR ALL PUNCH LIST ITEMS NOTED DURING GAF PRE-SOLAR INSPECTION 2.3. INSTALL A SLIP SHEET OF LIKE MATERIAL ANYWHERE THE SOLAR COMES INTO CONTACT WITH THE GAF ROOFING SYSTEM AND/OR HAVE A GAF MASTER OR MASTER SELECT ROOFING CONTRACTOR FLASH ALL PENETRATIONS WITH AN APPROVED GAF DETAIL INSTALL THE SOLAR PANELS PER SOLAR MANUFACTURE'S SPECIFICATIONS POST-INSPECTION FEE $600 BY GAF REQUIRED 2.6. REPAIR ALL PUNCH LIST ITEMS NOTED DURING POST-INSPECTION 3. GC TO VERIFY EXISTING CONDITIONS AND LOCATIONS OF EXISTING ROOF PENETRATIONS BEFORE THE START OF ANY ROOF WORK. 4. ALL NEW EXPOSED CONDUITS TO BE PAINTED TO MATCH NEARBY SURFACE, UON. 5. ALL NEW CONDUIT PENETRATIONS THROUGH ANY EXISTING WALL WILL BE CONTINUOUSLY SEALED ON INTERIOR AND EXTERIOR SIDE, SEE SPECIFICATIONS 6. ANY ADDITIONAL PENETRATIONS THROUGH THE ROOF MUST BE REVIEWED/APPROVED BY THE ARCHITECT 2 WEEKS BEFORE THE START OF ANY ROOF WORK. 7. GC TAKES FULL RESPONSIBILITY TO ANY ROOF DAMAGE OR EXISTING ROOF EQUIPMENT DAMAGE THROUGHOUT THE DURATION OF THE PROJECT. DAMAGE TO BE REPORTED/EVALUATED BY THE DESIGN TEAM FOR APPROPRIATE ACTION. ROOF DAMAGE TO BE PATCHED WITH GAF HYDROSTOP, PER MANUFACTURER'S RECOMMENDATIONS. 8. GC SHALL PROTECT ANY TRASH AND DEBRIS FROM ENTERING THE EXISTING ROOF DRAINS AND ALSO ENSURE IT REMAINS FUNCTIONAL THROUGHOUT THE DURATION OF THE PROJECT. 9. THE CONTRACTOR SHALL ENSURE THAT THE ROOF SHALL REMAIN WATER-TIGHT THROUGHOUT THE DURATION OF THE PROJECT. PARTIAL ROOF PLAN AND PV POST DETAILS 2 TYPICAL PV POST DETAIL SCALE: 3" = 1'-0" 0 3" 6" 9" 1' SCALE: 3" = 1'-0" 3

4 TYPICAL PV ROOF CONNECTION DETAIL INSYNERGY I ENGINEERING NC M E C H A N I C A L E L E C T R I C A L F I R E P R O T E C T I O N 828 Fort Street Mall Suite 500, Honolulu, Hawaii Phone: (808) Fax: (808)

5

6

7

8

9

10

11

12

13

14

15