A. FLORIDA FIRE PREVENTION CODE (2010) B. FLORIDA BUILDING CODE. MECHANICAL (2010) C. FLORIDA BUILDING CODE. PLUMBING (2010)

Size: px
Start display at page:

Download "A. FLORIDA FIRE PREVENTION CODE (2010) B. FLORIDA BUILDING CODE. MECHANICAL (2010) C. FLORIDA BUILDING CODE. PLUMBING (2010)"

Transcription

1

2 TYPICAL DRAWING NOTES TYPICAL DRAWING NOTES APPLICABLE BUILDING CODES GENERAL PROJECT SCOPE & REQUIREMENTS CONTRACT REQUIREMENTS AFFECTING ALL TRADES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND EACH OF HIS SUBCONTRACTORS TO REVIEW ALL DRAWINGS, PROJECT MANUAL, ADDENDA, ETC., TO ASSURE COORDINATION OF ALL WORK AFFECTING EACH TRADE. FAILURE TO REVIEW ALL CONTRACT DOCUMENTS FOR APPLICABLE ITEMS OF WORK SHALL NOT RELIEVE THE RESPONSIBLE PARTY FROM PERFORMING ALL WORK REQUIRED.. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE AND ALL APPLICABLE CODES AND ORDINANCES.. TERMINOLOGY, AS USED HEREIN, SHALL HAVE THE FOLLOWING MEANINGS: A. WORK: SHALL MEAN TO INCLUDE ALL MATERIALS, LABOR, AND EQUIPMENT REQUIRED FOR A COMPLETE INSTALLATION. B. OTHER TRADES: SHALL MEAN WORK IS TO BE DONE PERSONS OR PARTIES RESPONSIBLE FOR WORK AT THE PROJECT OTHER THAN THE PARTY OR PARTIES WHO HAVE BEEN DULY AWARDED A CONTRACT FOR WORK OF THIS DIVISION. C. DEMOLITION: SHALL MEAN THE REMOVAL OF ANY/ALL ITEMS NECESSARY TO PERMIT SUBSEQUENT WORK; REMOVAL OF DEBRIS LEAVING AREA AND SUBSTRATE CLEAN, DRY AND UNIFORM, AND IN A CONDITION SUITABLE FOR SUBSEQUENT WORK; REMOVAL OF EXISTING MATERIAL, STRUCTURES, CONSTRUCTION, EQUIPMENT, PIPING, DUCTS, ETC. AND THE CAPPING OR PLUGGING OF ANY EXISTING SERVICES. D. FURNISH: SHALL MEAN SUPPLY AND DELIVER TO PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR SUBSEQUENT REQUIREMENTS. E. INSTALL: SHALL MEAN UNLOAD AND UNPACK AT DESIGNATED DELIVERY POINT ON SITE; STORE IN A SAFE PROTECTED LOCATION AT SITE; PERFORM EVERY OPERATION NECESSARY TO ASSEMBLE, ERECT, PLACE, ANCHOR, AND APPLY ALL SPECIFIED MATERIALS/PRODUCTS, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING AND SIMILAR REQUIREMENTS. F. PROVIDE: PROVIDE AND VARIANTS THEREOF, AS USED HEREIN SHALL MEAN FURNISHING AND INSTALLATION OF ALL LABOR, MATERIALS, EQUIPMENT, TRANSPORTATION, AND SERVICES RENDERED READY FOR INTENDED USE. G. CONCEALED: SHALL MEAN EMBEDDED IN MASONRY OR OTHER CONSTRUCTION, INSTALLED BEHIND WALL FURRING AND WITHIN PARTITIONS, HUNG CEILINGS, CRAWL SPACES OR SHAFTS. H. EXPOSED: SHALL MEAN NOT CONCEALED.. CONTRACTOR TO VISIT THE SITE AND ALLOW FOR ALL EXISTING CONDITIONS IN HIS BID. THE CONTRACTOR SHALL HAVE A THOROUGH EXAMINATION OF THE SITE AND THE CONTRACT DOCUMENTS, PRIOR TO BID. NO CLAIM FOR EXTRA COMPENSATION WILL BE RECOGNIZED IF DIFFICULTIES ARE ENCOUNTERED WHICH AN EXAMINATION OF SITE CONDITIONS AND CONTRACT DOCUMENTS PRIOR TO EXECUTING CONTRACT WOULD HAVE REVEALED.. THE OWNER WILL NOT BE HELD LIABLE FOR FIELD CHANGES THAT ARISE FROM CONTRACTOR ERROR, OMISSION OF MATERIALS, AND/OR WORKMANSHIP IN TRADE PERFORMANCE.. SHOULD SHOP DRAWINGS BE APPROVED THAT AFFECT THE WORK OF OTHER TRADES, THE COST OF THE ADDITIONAL WORK SHALL BE BORNE THE CONTRACTOR WHOSE SHOP DRAWINGS HAVE BEEN APPROVED FOR THE CHANGE.. THE DRAWINGS ARE INTENDED TO SHOW THE GENERAL ARRANGEMENTS, DESIGN AND EXTENT OF THE WORK AND ARE PARTLY DIAGRAMMATIC. THEY ARE NOT INTENDED TO BE SCALED FOR ROUGHING-IN MEASUREMENTS OR TO SERVE AS SHOP DRAWINGS.. THE BUILDING DATA ON THE DRAWINGS IS REPRODUCED AS RECEIVED FROM THE RESPONSIBLE PROFESSIONAL AND/OR AS RECORDED FROM OBSERVATIONS IN THE FIELD. BECAUSE THE DRAWINGS MAY NOT REPRESENT THE EXISTING CONDITIONS EXACTLY, THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND SUBMIT NEW SHOP DRAWINGS OF ALL CONFLICTING CONDITIONS OR QUESTIONS OF INTERPRETATION. CBG&A, INC. ASSUMES NO RESPONSIBILITY FOR ITS ACCURACY OR MIS-INTERPRETATION OF THAT INFORMATION. 0. MAINTENANCE EXCLUSION: THESE DRAWINGS WERE PREPARED FOR CONSTRUCTION PURPOSES ONLY. THESE DRAWINGS ARE NOT TO BE USED FOR MAINTENANCE PURPOSES AS ACTUAL CONDITIONS MAY VARY FROM THAT SHOWN ON DRAWINGS DUE TO CHANGE ORDER, ALTERATIONS OTHERS, FIELD ADJUSTMENTS, ETC.. TYPES OF JOINT SEALANTS MAY NOT BE INDICATED AT ALL LOCATIONS.. ALL WORK SHALL BE AT THE CONVENIENCE OF THE OWNER AND SHALL BE EXECUTED TO AVOID DISRUPTION TO OCCUPANTS OF BUILDING, STAFF OR GENERAL PUBLIC. DEMOLITION AND RENOVATION ACTIVITIES AND PLANNED DISRUPTIONS TO BUILDING SYSTEMS TO BE COORDINATED IN ADVANCE. THE MIGRATION OF FUMES, DUSTS AND DEBRIS TO OCCUPIED PORTIONS OF THE BUILDING SHALL BE STRICTLY LIMITED.. FINAL CLEANING AT COMPLETION SHALL INCLUDE DUSTING OF ALL FINISHED SURFACES, VACUUMING, REMOVAL OF SPOTS, STAINS, LABELS, FINGERPRINTS, SPILLS, AND CLEANING OF ALL INTERIOR GLASS. PRODUCT APPROVAL PRODUCT APPROVAL: ALL EXTERIOR PRODUCTS SHALL BE TESTED AND APPROVED THE STATE OF FLORIDA AND HAVE A REGISTERED PRODUCT APPROVAL CODE. THE CONTRACTOR SHALL SUBMIT ALL PROPER FLORIDA APPROVAL DOCUMENTATION WITH THE SHOP DRAWINGS / SUBMITTALS FOR REVIEW AND COMMENT. ABBREVIATIONS. THE 00 FLORIDA BUILDING CODE WITH 00, ST SUPPLEMENT (EFFECTIVE 0-0-0) AND 00, ND SUPPLEMENT (EFFECTIVE 0-0-0).. REFERENCED CODES, ALL OR PORTIONS OF THE FOLLOWING CODES ARE HERE INCORPORATED IN AND MADE A PART OF THE FBC. IN THE CASE OF CONFLICTING REQUIREMENTS WHERE THE FBC IS MUTE. THE MORE. OR MOST. STRINGENT SHALL APPLY. A. FLORIDA FIRE PREVENTION CODE (00) B. FLORIDA BUILDING CODE. MECHANICAL (00) C. FLORIDA BUILDING CODE. PLUMBING (00) D. FLORIDA BUILDING CODE. FUEL GAS (00) E. NATIONAL ELECTRIC CODE (00) F. FEMA. FEDERAL EMERGENCY MANAGEMENT AGENCY. RULES AND REGULATIONS CFR. PARTS AND 0. G. FLORIDA STATUTES AND STATE RULES, INCLUDING, BUT NOT LIMITED TO, CHAPTERS 0,,,,,,,,, AND SECTION.0 F.S., AND VARIOUS STATE RULES AS APPLICABLE TO SPECIFIC PROJECTS. H. ANSI Z., AMERICA NATIONAL STANDARD SAFETY COLOR CODE FOR MARKING PHYSICAL HAZARDS, USED IN SHOPS WHERE MACHINERY REQUIRES MARKING AND SAFETY ZONES. I. ASCE -0 AMERICAN SOCIETY OF CIVIL ENGINEERS. MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES.. OTHER REGULATORY AGENCIES. BOARDS SHALL COORDINATE THE PLANNING OF PROJECTS WITH THE FOLLOWING REGULATORY AND PERMITTING AGENCIES AS APPLICABLE. FOR BOTH LOCAL AND REGIONAL ISSUES FOR PLAN APPROVAL. INSTALLATION PERMITS, FINAL INSPECTIONS, AND ANNUAL INSPECTIONS. A. OF LABOR AND EMPLOYMENT SECURITY (DLES). INSPECTIONS FOR WORK PLACE SAFETY. ARCHITECT STATEMENT OF COMPLIANCE: TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND THE PROJECT MANUAL ARE COMPLETE AND COMPLY WITH THE FLORIDA BUILDING CODE. THE TYPES OF WORK INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING BRIEF OUTLINE:. LANDSCAPING: A. PHOTOGRAPHICALLY DOCUMENT ALL LANDSCAPING AROUND PERIMETER OF BUILDING; B. PRUNING AND/OR TRIMMING OF EXISTING TREES/SHRUBS (WHERE REQUIRED) SHALL BE CONTRACTOR, SO AS NOT TO DELAY THE PROJECT. VERIFY WITH OWNER BEFORE ANY/ALL PRUNING WORK IS PERFORMED; C. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF THE EXISTING IRRIGATION SYSTEMS. D. CONTRACTOR SHALL PRETEST ALL IRRIGATION SYSTEMS BEFORE AND AFTER COMPLETION OF WORK AND PROVIDE A WRITTEN REPORT OF ANY NON-FUNCTIONING ELEMENTS. CONTRACTOR SHALL REPLACE ALL DAMAGED COMPONENTS AS REQUIRED TO BRING SYSTEM BACK TO ORIGINAL CONDITION AFTER COMPLETION OF THE WORK. E. INSTALL NEW SOD TO REPLACE THAT WHICH WAS DESTROYED DURING THE WORK.. FLASHING, SHEET METAL AND ACCESSORIES - REFER TO SECTION : A. PROVIDE NEW METAL FLASHINGS AND COUNTER FLASHINGS PER TYPICAL DETAILS. FIELD TEMPLATE AND SHOP FABRICATE METAL FLASHINGS AS MUCH AS POSSIBLE. B. PROVIDE NEW DRIP FLASHING OVER HEAD OF WINDOWS AND DOORS, PER TYPICAL DETAIL; C. PROVIDE NEW METAL HOODS OVER ALL EXTERIOR WALL LOUVERS, PER TYPICAL DETAILS; D. PROVIDE NEW SPECIFIED NON-CORROSIVE FASTENERS, WHERE REMOVED OR REPLACED. UNLESS OTHERWISE INDICATED, PROVIDED ONLY STAINLESS STEEL FASTENERS. GALVANIZED ANCHORS AND/OR FASTENERS ARE NOT ACCEPTABLE.. SEALANTS - REFER TO SECTION 0 00: A. REMOVE ALL EXISTING EXPOSED SEALANT, WHERE EXISTING. PREPARE SURFACES, PRIME AND APPLY NEW SPECIFIED SEALANT, PER SEALANT SCHEDULE AND WHERE NOTED ON DRAWINGS. B. APPLY NEW SPECIFIED SEALANT AT ALL OPEN JOINTS. C. APPLY NEW SPECIFIED SEALANT AROUND ALL SURFACE- MOUNTED AND THRU-WALL FIXTURES, D. APPLY NEW SPECIFIED SEALANT AT ALL CRACKS IN WALLS.. PAINTING - REFER TO SECTIONS 0 00 AND SECTION 0 : A. PREPARE SURFACES AND APPLY NEW SPECIFIED PAINT COATINGS TO ALL EXTERIOR SURFACES, PER DRAWINGS AND PAINT SCHEDULE. B. BUILDING G: REMOVE ALL EXISTING COATINGS DOWN TO BARE CONCRETE BLOCK. C. BUILDING F: IT IS NOT THE INTENT OF THIS SPECIFICATION TO REMOVE ALL THE EXISTING PAINT PRIOR TO RECOATING THE SURFACES AT BUILDING F, BUT ADEQUATE SURFACE PREPARATION IS A REQUIREMENT OF THESE SPECIFICATIONS. IF ADDITIONAL PREPARATION WORK IS NEEDED AFTER THE SURFACES HAVE BEEN PRESSURE WASHED, CONTRACTOR SHALL NOTIFY ARCHITECT AND COATINGS MANUFACTURER TO REVIEW THE SURFACE CONDITIONS AND TO DISCUSS ALTERNATE METHODS AND/OR TECHNIQUES FOR REMOVING THE EXISTING PAINT AND/OR SMOOTHING OUT THE EXISTING SURFACES. ALTERNATE PREPARATION METHODS NECESSARY TO PROVIDE AN ACCEPTABLE SUBSTRATE FOR COATINGS SHALL BE AT NO ADDITIONAL COST TO OWNER. D. PAINT NEW FLASHING AND SHEET METAL WORK, WHERE INDICATED ON DETAILS. E. PAINT ALL METAL DOORS AND FRAMES, INSIDE AND OUTSIDE SURFACES. PROTECT ALL EXISTING DOOR HARDWARE AND ACCESSORIES. F. PREPARE SURFACES AND PAINT ALL EXTERIOR (PREVIOUSLY PAINTED) METAL RAILINGS. PREPARE SURFACES AND TREAT ALL RUSTED STEEL. FEATHER WORK FOR NEW PAINT COATINGS. G. PREPARE SURFACES AND PAINT ALL PREVIOUSLY COATED SURFACE-MOUNTED, EXTERIOR CONDUIT, PIPING, ETC. H. EXTERIOR AND EXTERIOR FINISHES: PROVIDE SATIN FINISH FOR ALL STUCCO, CONCRETE AND MASONRY SURFACES. PROVIDE GLOSS FINISH FOR ALL COATED METALS. I. COLORS: ALL PAINT COLORS ARE TO BE SELECTED AND APPROVED OWNER. J. CONTRACTOR TO PROVIDE ADEQUATE PROTECTION TO PREVENT LOOSE PAINT CHIPS FROM BEING WASHED INTO DRAINS. K. CONTRACTOR S WARRANTY: YEARS. L. MANUFACTURER S WARRANTY (WATERPROOF COATING SYSTEM): 0 YEARS.. IF AND TO THE EXTENT THAT ANY PART OF THE CONTRACT DOCUMENTS CONFLICT, THE DOCUMENTS SHALL BE INTERPRETED THE ARCHITECT WHO SHALL ASSIGN PRIORITY BASED ON THE INTENT OF THE CONTRACT DOCUMENTS. 0. IT IS RECOGNIZED THAT LOCATIONS OF THE WORK INDICATED ON THE DRAWINGS ARE DIAGRAMMATIC, EXCEPT FOR FIGURES AND DIMENSIONS, AND THAT FIELD CONDITIONS MAY ARISE THAT WILL PREVENT THEIR BEING INSTALLED, WITHIN THE LIMITS ESTABLISHED. THEREFORE, IT SHALL BE THE DUTY OF THE CONTRACTOR AND EACH SUBCONTRACTOR TO CONSULT WITH EACH OTHER, VERIFYING EXISTING CONDITIONS AND/OR LOCATIONS OF WORK, AND TO SUBMIT A WORKABLE SOLUTION TO ARCHITECT FOR PRIOR APPROVAL BEFORE INSTALLING ANY WORK WHICH IS QUESTIONABLE.. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY CONDITION HE FINDS, IN HIS JUDGEMENT, WHERE IT WOULD BE DESIRABLE TO MODIFY THE REQUIREMENT TO PRODUCE A BETTER RESULT. IF CONTRACTOR FAILS TO SO NOTIFY ARCHITECT, OR IF HIS RECOMMENDATIONS FOR MODIFICATIONS ARE ACCEPTED, CONTRACTOR ASSUMES SOLE RESPONSIBILITY FOR SATISFACTORY RESULTS.. WHERE A TYPICAL OR REPRESENTATIVE DETAIL IS SHOWN (WHETHER INDICATED TYPICAL OR NOT) THIS DETAIL SHALL CONSTITUTE THE STANDARD IN WORKMANSHIP AND MATERIALS THROUGHOUT CORRESPONDING PARTS OF THE WORK. ADAPTATION, HOWEVER, SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT. SOME DETAILS ON THE PLANS MAY NOT BE INDICATED AT EACH LOCATION THAT CONDITION OCCURS. CONTRACTOR SHALL PERFORM WORK AS IF THE DETAILS WERE INDICATED ON THE PLAN(S) OR, WHERE SIMILAR DETAILS OCCUR. WHERE NECESSARY, THE CONTRACTOR SHALL ADOPT SUCH DETAIL FOR USE IN SUCH CORRESPONDING PORTIONS OF THE WORK IN A MANNER THAT IS SATISFACTORY TO THE ARCHITECT. DETAILS AND/OR DUCT TRANSITIONS THAT ARE NOT SHOWN SHALL BE REQUIRED AS IF THEY WERE INDICATED ON THE PLANS. CONTRACTOR SHALL SUBMIT NEW SHOP DRAWINGS TO THE ARCHITECT FOR REVIEW AND APPROVAL.. IF DIRECTED THE ARCHITECT, THE CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE REASONABLE MODIFICATIONS IN THE LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF OTHER TRADES OR FOR PROPER EXECUTION OF THE WORK.. THE USE OF A WORD IN THE SINGULAR SHALL NOT BE CONSIDERED AS LIMITING WHERE OTHER INDICATIONS DENOTE THAT MORE THAN ONE ITEM IS REFERRED TO. THE DETERMINING OF CORRECT QUANTITIES SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.. APPARENT SILENCE OF SPECIFICATIONS AS TO ANY DETAIL OR APPARENT OMISSION FROM ITEM OF DETAILED DESCRIPTION CONCERNING ANY WORK TO BE DONE AND MATERIALS TO BE FURNISHED SHALL BE REGARDED AS MEANING THAT ONLY BEST GENERAL PRACTICE IS TO PREVAIL AND THAT ONLY MATERIAL AND WORKMANSHIP OF FIRST QUALITY IS TO BE USED IN THIS CONNECTION, AND ALL INTERPRETATIONS OF THESE SPECIFICATIONS SHALL BE MADE UPON THIS BASIS.. CONTRACTOR SHALL PROTECT ALL EXISTING CONSTRUCTION INTENDED TO REMAIN. DO NOT REMOVE MORE MATERIAL THAN CAN BE PROTECTED IN THE EVENT OF SUDDEN WIND, RAIN OR INCLEMENT WEATHER. PROTECT FLOORS WITH SUITABLE COVERINGS WHEN NECESSARY. RESTORE ALL DAMAGE TO ORIGINAL CONDITION AT NO COST TO THE OWNER. PROTECT AGAINST FUMES, DUST AND DEBRIS FROM ENTERING AIR INTAKE DUCTS AND OPENINGS. DO NOT OBSTRUCT STREETS, WALKS OR PREMISES WITHOUT PRIOR AUTHORIZATION.. THE CONTRACTOR SHALL BE FULLY AND SOLELY RESPONSIBLE FOR ALL MATTERS OF SAFETY OF PERSON AND PROPERTY ARISING FROM THIS CONTRACT, INCLUDING THE LIABILITIES AND RESPONSIBILITIES OF ALL SUBCONTRACTORS. NEITHER THE ARCHITECT NOR THE OWNER OR ANY OF THEIR REPRESENTATIVES OR EMPLOYEES ARE TO BE ASSUMED TO HAVE ANY ROLE OF RESPONSIBILITY OF MATTERS OF SAFETY EXCEPT THEY (INCLUDING THE ARCHITECT) SHALL HAVE THE AUTHORITY TO ORDER STOPPING OF A PORTION OF THE WORK WHICH THEY NOTICE MAY ENDANGER OCCUPANTS, EMPLOYEES OF THE OWNER, OR THE PUBLIC, OR EMPLOYEES OF THE CONTRACTOR OR SUBCONTRACTORS.. CONSTRUCT ALL NECESSARY CHUTES, PLATFORMS OR EDGE DEVICES TO PROTECT PROPERTY AND EQUIPMENT FROM DAMAGE. PROVIDE SPECIAL PROTECTION FOR ALL EXISTING WORK NOT BEING REMOVED. ALL NECESSARY PRECAUTIONS SHALL BE TAKEN TO PREVENT ANY OBJECT FROM FALLING OFF THE ROOF OR SIDE OF BUILDING. CONTRACTOR SHALL VERIFY THAT ALL BUILDING DRAINS AND DRAIN LEADERS OF ANY TYPE ARE IN GOOD WORKING ORDER AND REPORT ALL NON-FUNCTIONAL DRAINS TO ARCHITECT PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR SHALL PROTECT ALL DRAINS DURING CONSTRUCTION AND REPAIR TO WORKING CONDITION IF DAMAGED OR OBSTRUCTED.. THE CONTRACTOR SHALL KEEP THE PREMISES AND SURROUNDING AREA FREE OF ACCUMULATION OF WASTE MATERIALS OR RUBBISH CAUSED THIS WORK. THE CONTRACTOR SHALL COMPLETELY REMOVE THE WASTE MATERIAL AND RUBBISH IN A LEGAL MANNER NO LESS FREQUENTLY THAN ONCE A WEEK. THE COST OF ADDITIONAL CLEANING REQUIRED THE OWNER FOR WHICH THE CONTRACTOR FAILS TO DO, SHALL BE BACK-CHARGED THE OWNER TO THE CONTRACTOR WHETHER DONE THE OWNER'S OWN FORCES OR SEPARATE CONTRACT WITH OTHERS. AB ABBREV APPR A/C AFF ALUM BD BLDG BLK BM BOB BOT C/C CH CJ CLG CLO CLR CMU COL CONC CONN CONT CORR CSK DET DIA DIAG DIM DIR DBL DN DR DS DWG EA ELEC EL EQ EQUIP EXIST EJ EXT FIN FLR FO FOUND FS FT GA GEJ GL GALV GR GWB HDWD HORIZ HM ANCHOR BOLTS ABBREVIATION(S) APPROVED AIR CONDITIONING AFTER FINISHED FLOOR ALUMINUM BOARD BUILDING BLOCK BEAM BOTTOM OF BEAM BOTTOM CENTER TO CENTER CEILING HEIGHT CONSTRUCTION JOINT CEILING CLOSET CLEAR CONC MASONRY UNIT COLUMN CONCRETE CONNECTION CONTINUOUS CORRIDOR COUNTER SINK DETAIL DIAMETER DIAGONAL DIMENSION DIRECTION DOUBLE DOWN DOOR DOWNSPOUT DRAWING EACH ELECTRICAL ELEVATION EQUAL EQUIPMENT EXISTING EXPANSION JOINT EXTERIOR FINISH FLOOR FINISHED OPENING FOUNDATION FULL SIZE FEET GAUGE GUTTER EXPANSION JOINT GLASS GALVANIZED GRADE GYPSUM WALL BOARD HARDWOOD HORIZONTAL HOLLOW METAL ID INSUL INT LEV LTG LTWT MAINT MAT'L MAX MECH MET MFR MISC MO MIN N N.I.C. NO NTS NR OC OD OPN'G PL PLAS PLYWD PR PREP RAD RD REF REINF REQ'D RM RO SECT SF SIM SPECS SS STD STL STRUCT SYM T&G TEMP THK TYP UNO VER VERT INSIDE DIAMETER INSULATION INTERIOR LEVEL LIGHTING LIGHT WEIGHT MAINTENANCE MATERIAL MAXIMUM MECHANICAL METAL MANUFACTURER MISCELLANEOUS MASONRY OPENINGS MINIMUM NEW NOT IN CONTRACT NUMBER NOT TO SCALE NON RATED OFF CENTER OUTSIDE DIAMETER OPENING PLATE PLASTER PLYWOOD PAIR PREPARATION RADIUS ROOF DRAIN REFERENCE REINFORCE REQUIRED ROOM ROUGH OPENING SECTION SQUARE FEET SIMILAR SPECIFICATIONS STAINLESS STEEL STANDARD STEEL STRUCTURAL SYMETRICAL TONGUE & GROOVE TEMPERED THICK TYPICAL UNLESS NOTED OTHERWISE VERIFY VERTICAL W WIDE W/ WITH WD WOOD. MISCELLANEOUS A. REPAIR ALL EXISTING SIDEWALKS DAMAGED DURING COURSE OF WORK. THE BURDEN SHALL BE ON THE CONTRACTOR TO DEMONSTRATE IF THE SIDEWALKS WERE DAMAGED PRIOR TO START OF WORK. B. REMOVE ALL EXTERIOR WALL-MOUNTED SIGNAGE AND REINSTALL AFTER PAINT APPLICATION.. PROVIDE APPROPRIATE PLATFORMS AND ACCESS TO PERFORM THE WORK PER OSHA REQUIREMENTS.. PROTECT PUBLIC AND PRIVATE PROPERTY FROM CONSEQUENTIAL DAMAGE FROM THE WORK OF THIS CONTRACT.. CLEAN UP. THESE DRAWINGS AND THEIR CONTENTS ARE THE SOLE PROPERTY OF C. B. GOLDSMITH AND ASSOCIATES, INC. USE OR COPY OF ALL OR ANY PORTIONS IS AUTHORIZED CONTRACT ONLY. COPYRIGHT 0, C. B. GOLDSMITH & ASSOCIATES, ALL RIGHTS RESERVED. R E V I S I O N S APPROVED : : NOT TO SCALE DRAWING NO GENERAL NOTES G-00

3 '- '-0 '- 0'-0. METAL DOORS AND FRAMES, INTERIOR AND EXTERIOR SURFACES.. PREVIOUSLY PAINTED EXTERIOR MOUNTED PIPES, ELECTRICAL BOXES AND CONDUITS.. ALL EXTERIOR STUCCO, CONCRETE AND CONCRETE MASONRY SURFACES AT ALL EXTERIOR WALLS.. UNLESS NOTED OTHERWISE, PRE-FINISHED METALS NOT PREVIOUSLY PAINTED ARE N.I.C.. REMOVE ALL EXISTING EXPOSED SEALANT, WHERE EXISTING. PREPARE SURFACES, PRIME AND APPLY NEW SPECIFIED SEALANT.. APPLY NEW SPECIFIED SEALANT AT ALL OPEN JOINTS.. APPLY NEW SPECIFIED SEALANT AROUND ALL SURFACE- MOUNTED AND THRU-WALL FIXTURES, EQUIPMENT, AWNINGS, BOXES, ETC. DO NOT SEAL BOTTOM OF SURFACED-MOUNTED FIXTURES.. APPLY NEW SPECIFIED SEALANT AT ALL CRACKS IN WALLS. NOTE: THE BUILDING DATA ON THE DRAWINGS IS REPRODUCED AS RECORDED FROM OBSERVATIONS IN THE FIELD. BECAUSE THE DRAWINGS MAY NOT REPRESENT THE EXISTING CONDITIONS EXACTLY, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND SUBMIT NEW SHOP DRAWINGS OF ALL CONFLICTING CONDITIONS OR QUESTIONS OF INTERPRETATION. 0' ' ' ' ' ' N A A-0 OVERALL FLOOR PLAN / = '-0 R E V I S I O N S APPROVED : : A-0 DRAWING NO FLOOR PLANS

4 . METAL DOORS AND FRAMES, INTERIOR AND EXTERIOR SURFACES.. PREVIOUSLY PAINTED EXTERIOR MOUNTED PIPES, ELECTRICAL BOXES AND CONDUITS.. ALL EXTERIOR STUCCO, CONCRETE AND CONCRETE MASONRY SURFACES AT ALL EXTERIOR WALLS.. UNLESS NOTED OTHERWISE, PRE-FINISHED METALS NOT PREVIOUSLY PAINTED ARE N.I.C..... REMOVE ALL EXISTING EXPOSED SEALANT, WHERE EXISTING. PREPARE SURFACES, PRIME AND APPLY NEW SPECIFIED SEALANT. APPLY NEW SPECIFIED SEALANT AT ALL OPEN JOINTS. APPLY NEW SPECIFIED SEALANT AROUND ALL SURFACE- MOUNTED AND THRU-WALL FIXTURES, APPLY NEW SPECIFIED SEALANT AT ALL CRACKS IN WALLS. ELEVATION KEY NOTES (TYPICAL): CONTRACTOR SHALL PERFORM WORK AS IF THE FOLLOWING ITEMS ARE INDICATED THROUGHOUT OR WHERE SIMILAR DETAILS/ CONDITIONS OCCUR: PREPARE, PRIME, AND PAINT EXISTING COPING FRONT FACE ONLY (TOP AND BACK FACES OF COPING ARE N.I.C.). TEMPORARILY REMOVE EXISTING DOWNSPOUT AND COLLECTOR BOX AND APPLY NEW WATER-PROOF COATING SYSTEM. REINSTALL EXISTING DOWNSPOUT AND COLLECTOR BOX WITH NEW S.S. FASTENERS. EXISTING FENCE. (DO NOT PAINT) NEW CONTINUOUS SURFACE-MOUNTED COUNTER FLASHING. REFER TO DETAIL D0. LAP OVER JOINT -/ (TYPICAL). NEW DRIP FLASHING OVER ALL EXTERIOR WINDOWS. REFER TO DETAIL D0. PREPARE PRIME AND PAINT EXISTING GUARDRAIL SYSTEM, SEE SPECIFICATIONS. NEW ALUMINUM EXHAUST LOUVER HOOD. REFER TO DETAIL D0. PREPARE SURFACES, PRIME AND PAINT EXISTING STEEL DOORS. MASK OFF EXISTING HARDWARE. REMOVE ALL EXISTING COATINGS DOWN TO BARE CONCRETE MASONRY WALL (BUILDING G), PRIME AND APPLY NEW SPECIFIED HIGH-BUILD WATERPROOF COATING AND COVER COAT. TOC FIN. FL. 0 NORTH ELEVATION SOUTH ELEVATION REMOVE EXISTING THRU-WALL EXHAUST HOOD AND WOOD BLOCKING AND REPLACE WITH NEW ALUMINUM EXHAUST HOOD. RECONNECT TO EXISTING DUCT. PREPARE SURFACES AND PAINT EXISTING (PREVIOUSLY PAINTED) METAL CONDUITS, JUNCTION, BOXES, SUPPORTS, ETC. PREPARE SURFACES, PRIME AND APPLY NEW SPECIFIED HIGH-BUILD WATERPROOF COATING AND COVER COAT (BUILDING F). EAST ELEVATION WEST ELEVATION BLDG. G BLDG. F REVISIONS KEY PLAN APPROVED : : DRAWING NO EXTERIOR ELEVATIONS A-0

5 0. METAL DOORS AND FRAMES, INTERIOR AND EXTERIOR SURFACES.. PREVIOUSLY PAINTED EXTERIOR MOUNTED PIPES, ELECTRICAL BOXES AND CONDUITS.. ALL EXTERIOR STUCCO, CONCRETE AND CONCRETE MASONRY SURFACES AT ALL EXTERIOR WALLS.. UNLESS NOTED OTHERWISE, PRE-FINISHED METALS NOT PREVIOUSLY PAINTED ARE N.I.C REMOVE ALL EXISTING EXPOSED SEALANT, WHERE EXISTING. PREPARE SURFACES, PRIME AND APPLY NEW SPECIFIED SEALANT. APPLY NEW SPECIFIED SEALANT AT ALL OPEN JOINTS. APPLY NEW SPECIFIED SEALANT AROUND ALL SURFACE- MOUNTED AND THRU-WALL FIXTURES, APPLY NEW SPECIFIED SEALANT AT ALL CRACKS IN WALLS. ELEVATION KEY NOTES (TYPICAL): CONTRACTOR SHALL PERFORM WORK AS IF THE FOLLOWING ITEMS ARE INDICATED THROUGHOUT OR WHERE SIMILAR DETAILS/ CONDITIONS OCCUR: 0 PREPARE, PRIME, AND PAINT EXISTING COPING FRONT FACE ONLY (TOP AND BACK FACES OF COPING ARE N.I.C.). TEMPORARILY REMOVE EXISTING DOWNSPOUT AND COLLECTOR BOX AND APPLY NEW WATER-PROOF COATING SYSTEM. REINSTALL EXISTING DOWNSPOUT AND COLLECTOR BOX WITH NEW S.S. FASTENERS. EXISTING FENCE. (DO NOT PAINT) NEW CONTINUOUS SURFACE-MOUNTED COUNTER FLASHING. REFER TO DETAIL D0. LAP OVER JOINT -/ (TYPICAL). NEW DRIP FLASHING OVER ALL EXTERIOR WINDOWS. REFER TO DETAIL D0. PREPARE PRIME AND PAINT EXISTING GUARDRAIL SYSTEM, SEE SPECIFICATIONS. NEW ALUMINUM EXHAUST LOUVER HOOD. REFER TO DETAIL D0. PREPARE SURFACES, PRIME AND PAINT EXISTING STEEL DOORS. MASK OFF EXISTING HARDWARE. REMOVE ALL EXISTING COATINGS DOWN TO BARE CONCRETE MASONRY WALL (BUILDING G), PRIME AND APPLY NEW SPECIFIED HIGH-BUILD WATERPROOF COATING AND COVER COAT. 0 NORTH ELEVATION PREPARE SURFACES, PRIME AND APPLY NEW SPECIFIED HIGH-BUILD WATERPROOF COATING AND COVER COAT (BUILDING F). REMOVE EXISTING THRU-WALL EXHAUST HOOD AND WOOD BLOCKING AND REPLACE WITH NEW ALUMINUM EXHAUST HOOD. RECONNECT TO EXISTING DUCT. 0 PREPARE SURFACES AND PAINT EXISTING (PREVIOUSLY PAINTED) METAL CONDUITS, JUNCTION, BOXES, SUPPORTS, ETC. SOUTH ELEVATION BLDG. F BLDG. G REVISIONS KEY PLAN APPROVED : : DRAWING NO EXTERIOR ELEVATIONS A-0

6 0. METAL DOORS AND FRAMES, INTERIOR AND EXTERIOR SURFACES.. PREVIOUSLY PAINTED EXTERIOR MOUNTED PIPES, ELECTRICAL BOXES AND CONDUITS.. ALL EXTERIOR STUCCO, CONCRETE AND CONCRETE MASONRY SURFACES AT ALL EXTERIOR WALLS.. UNLESS NOTED OTHERWISE, PRE-FINISHED METALS NOT PREVIOUSLY PAINTED ARE N.I.C REMOVE ALL EXISTING EXPOSED SEALANT, WHERE EXISTING. PREPARE SURFACES, PRIME AND APPLY NEW SPECIFIED SEALANT. APPLY NEW SPECIFIED SEALANT AT ALL OPEN JOINTS. APPLY NEW SPECIFIED SEALANT AROUND ALL SURFACE- MOUNTED AND THRU-WALL FIXTURES, APPLY NEW SPECIFIED SEALANT AT ALL CRACKS IN WALLS. ELEVATION KEY NOTES (TYPICAL): CONTRACTOR SHALL PERFORM WORK AS IF THE FOLLOWING ITEMS ARE INDICATED THROUGHOUT OR WHERE SIMILAR DETAILS/ CONDITIONS OCCUR: 0 0 TOC FIN. FL. WEST ELEVATION PREPARE, PRIME, AND PAINT EXISTING COPING FRONT FACE ONLY (TOP AND BACK FACES OF COPING ARE N.I.C.). TEMPORARILY REMOVE EXISTING DOWNSPOUT AND COLLECTOR BOX AND APPLY NEW WATER-PROOF COATING SYSTEM. REINSTALL EXISTING DOWNSPOUT AND COLLECTOR BOX WITH NEW S.S. FASTENERS. EXISTING FENCE. (DO NOT PAINT) NEW CONTINUOUS SURFACE-MOUNTED COUNTER FLASHING. REFER TO DETAIL D0. LAP OVER JOINT -/ (TYPICAL). NEW DRIP FLASHING OVER ALL EXTERIOR WINDOWS. REFER TO DETAIL D0. PREPARE PRIME AND PAINT EXISTING GUARDRAIL SYSTEM, SEE SPECIFICATIONS. NEW ALUMINUM EXHAUST LOUVER HOOD. REFER TO DETAIL D0. PREPARE SURFACES, PRIME AND PAINT EXISTING STEEL DOORS. MASK OFF EXISTING HARDWARE. REMOVE ALL EXISTING COATINGS DOWN TO BARE CONCRETE MASONRY WALL (BUILDING G), PRIME AND APPLY NEW SPECIFIED HIGH-BUILD WATERPROOF COATING AND COVER COAT. 0 EAST ELEVATION PREPARE SURFACES, PRIME AND APPLY NEW SPECIFIED HIGH-BUILD WATERPROOF COATING AND COVER COAT (BUILDING F). REMOVE EXISTING THRU-WALL EXHAUST HOOD AND WOOD BLOCKING AND REPLACE WITH NEW ALUMINUM EXHAUST HOOD. RECONNECT TO EXISTING DUCT. / SEALANT TRAY PREPARE SURFACES AND PAINT EXISTING (PREVIOUSLY PAINTED) METAL CONDUITS, JUNCTION, BOXES, SUPPORTS, ETC. 0 SECURE O.C. WITH SPECIFIED FASTENERS. (EQUALLY SPACED) (MIN) / LAP JOINT (MIN) / HELIARC ALL JOINTS SOLID. TYPICAL CORNER TRANSITION / / WALL OPENING (VERIFY WIDTH) -/ (APPROX.) / LAP /. NEW SPECIFIED FOAM BACKER TAPE. APPLY IN CONT'S LENGTHS TO BACK OF FLASHING. NOTES:. ANCHOR FLASHING SECURELY WITH SPECIFIED FASTENERS AT -IN. O.C. NEW SURFACE-MOUNTED DRIP FLASHING. SHOP FABRICATE TO CONFIGURATION SHOWN. HEM ALL EDGES. PRE-DRILL ALL HOLES. PAINT FLASHING TO MATCH SURROUNDING SURFACES, OR AS SELECTED OWNER. SECURE WITH SPECIFIED FASTENERS AT -IN. O.C.. LAP ALL JOINTS -IN. (MINIMUM). INSTALL TWO CONT'S BEADS OF SPECIFIED SEALANT BETWEEN METAL AT LAPS.. NEW SPECIFIED FOAM BACKER TAPE. APPLY IN CONTINUOUS LENGTHS TO BACK OF FLASHING... LAP ALL JOINTS -IN. (MINIMUM). INSTALL TWO CONTINUOUS BEADS OF SPECIFIED SEALANT BETWEEN METAL AT LAPS. APPLY CONT'S BEAD OF SPECIFIED SEALANT (STP-0) AT TOP FLARE. TOOL AS NECESSARY TO PROVIDE UNIFORM, SLOPING, FULLY ADHERED SEALANT BEAD (TYPICAL). PROVIDE NEW SURFACE-MOUNTED DRIP FLASHING ABOVE ALL WINDOW NOT PROTECTED AN OVERHANG GREATER THAN -INCHES. / SCOPE OF WORK: NEW SURFACE MOUNTED COUNTER FLASHING. SHOP FABRICATE TO CONFIGURATION SHOWN. PROVIDE -IN. END PLATES AT ALL END CONDITIONS. POP RIVET SECTIONS TO CONFORM TO FIELD CONDITIONS AND SOLDER SOLID. HEM ALL EDGES. PRE-DRILL ALL HOLES. NOT PAINTED. (APPROX.). APPROX. STRETCH-OUT = -INCHES / PROFILE SECTION -/ ELEVATION DETAIL NOTES:. D0 ALUMINUM EXHAUST LOUVER HOOD D0 APPLY CONTINUOUS BEAD OF SPECIFIED SEALANT AT TOP FLARE. TOOL AS NECESSARY TO PROVIDE UNIFORM, SLOPING, FULLY ADHERED SEALANT BEAD (TYPICAL). D0 DRIP FLASHING REVISIONS /. /. PROFILE SECTION CORNER SECTIONS AND BENDS SHALL BE PREFABRICATED AT -IN. OUTSIDE OF CORNERS AND SOLDERED SOLID. DO NOT FIELD SPLICE CORNERS. SURFACE-MOUNTED COUNTER FLASHING BLDG. G KEY PLAN APPROVED : BLDG. F : DRAWING NO EXTERIOR ELEVATIONS A-0